{"product_id":"thermopompe-murale-senville-aura-r454b-15000-btu-montreal-rive-sud-nord","title":"SENVILLE AURA R454B Wall-Mounted Heat Pump | 15000 BTU | Montréal, South Shore \u0026 North Shore","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA 15,000 BTU wall-mounted heat pump that fits between the 12,000 and 18,000 BTU sizes\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e15,000 BTU SENVILLE AURA R454B\u003c\/strong\u003e occupies a particularly interesting position in the wall-mounted heat pump lineup. It is intended for homeowners who need more capacity than a 12,000 BTU unit without necessarily moving up to an 18,000 BTU unit that could be oversized for the room.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, this is exactly the kind of situation we encounter in Greater Montreal: a living room open to the dining room, a relatively open condo floor, a medium-sized commercial space, or a family area where the thermal load slightly exceeds what a small wall-mounted system can comfortably handle.\u003c\/p\u003e\n\u003cp\u003eFor this new-generation AURA, Senville combines a nominal capacity of \u003cstrong\u003e15,000 BTU\u003c\/strong\u003e, \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant, variable-speed technology, \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certification, Alexa compatibility, and a stated heating operating range down to \u003cstrong\u003e-25 °C\u003c\/strong\u003e. The supplied documentation also presents the unit as a cold-climate heat pump and recommends professional installation to preserve warranty coverage. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe certified combination consists of the \u003cstrong\u003eSENA-15HF-OG\u003c\/strong\u003e outdoor unit and the \u003cstrong\u003eSENA-15HF-IGG\u003c\/strong\u003e indoor unit, with AHRI reference number \u003cstrong\u003e217603532\u003c\/strong\u003e. The active AHRI certification confirms, among other things, a cooling capacity of 15,000 BTU\/h, a \u003cstrong\u003eSEER2 of 23.5\u003c\/strong\u003e, an \u003cstrong\u003eEER2 of 11.7\u003c\/strong\u003e, and an \u003cstrong\u003eHSPF2 Region IV of 9.9\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eThe technical specifications that really matter\u003c\/h3\u003e\n\u003cp\u003eHere are the main technical specifications of the SENVILLE AURA 15,000 BTU:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSENVILLE AURA 15,000 BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSENA-15HF-OG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSENA-15HF-IGG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI reference\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e217603532\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal cooling capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8,000 to 15,200 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heating capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,600 to 16,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23,5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11,7\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Region IV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9,9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Region V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7,5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStated nominal COP\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR454B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum protection\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStated minimum heating temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-25 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor airflow\u003c\/td\u003e\n\u003ctd\u003eup to \u003cstrong\u003e450.3 CFM\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.7 L\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e57 dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart control\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApp \/ Alexa\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer’s stated warranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-year compressor \/ 5-year parts\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese values are particularly important because they make it possible to assess the unit based on more than just the “15,000 BTU” printed on the box. Senville’s documentation confirms, in particular, modulation ranges of \u003cstrong\u003e8,000 to 15,200 BTU\/h in cooling\u003c\/strong\u003e and \u003cstrong\u003e3,600 to 16,000 BTU\/h in heating\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhy modulation is important in a condo, plex, or house\u003c\/h3\u003e\n\u003cp\u003eA variable-speed heat pump is not designed to operate continuously at maximum capacity. It adjusts its operation according to demand.\u003c\/p\u003e\n\u003cp\u003eIn an open-concept area that requires substantial cooling at 4 p.m. on a hot July day, the SENVILLE AURA can increase its output. Later, when the indoor temperature stabilizes, it can reduce its operating rate.\u003c\/p\u003e\n\u003cp\u003eThis modulation helps limit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003erepeated starts and stops;\u003c\/li\u003e\n\u003cli\u003esignificant temperature fluctuations;\u003c\/li\u003e\n\u003cli\u003eunnecessary noise;\u003c\/li\u003e\n\u003cli\u003econsumption peaks;\u003c\/li\u003e\n\u003cli\u003ethe comfort problems associated with a significantly oversized unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat is one reason why, at \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we do not automatically choose an 18,000 or 24,000 BTU heat pump simply because higher capacity seems reassuring on paper.\u003c\/p\u003e\n\u003ch3\u003e15,000 BTU: what area does it cover?\u003c\/h3\u003e\n\u003cp\u003eSenville indicates a reference area of approximately \u003cstrong\u003e600 to 800 sq. ft.\u003c\/strong\u003e for this unit. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis value is a good starting point, but we never recommend sizing a \u003cstrong\u003ewall-mounted heat pump in Montreal, Laval, Longueuil, on the North Shore, or on the South Shore\u003c\/strong\u003e based solely on the number of square feet.\u003c\/p\u003e\n\u003cp\u003eTwo 700 sq. ft. spaces can have completely different needs.\u003c\/p\u003e\n\u003cp\u003eA newer condo in Boucherville with good insulation, few sun-exposed windows, and a standard ceiling may require much less capacity than the top floor of a Montreal plex with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003elarge southwest-facing windows;\u003c\/li\u003e\n\u003cli\u003ea roof directly above the dwelling;\u003c\/li\u003e\n\u003cli\u003eolder insulation;\u003c\/li\u003e\n\u003cli\u003ea high ceiling;\u003c\/li\u003e\n\u003cli\u003ean open-concept kitchen;\u003c\/li\u003e\n\u003cli\u003eseveral occupants;\u003c\/li\u003e\n\u003cli\u003esignificant solar gains in the afternoon.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e15,000 BTU\u003c\/strong\u003e becomes particularly appealing when the analysis genuinely falls between the usual 12,000 and 18,000 BTU categories.\u003c\/p\u003e\n\u003ch3\u003eA typical scenario we encounter at AirGreen\u003c\/h3\u003e\n\u003cp\u003eLet’s take a common configuration in Greater Montreal: approximately 650 to 750 sq. ft. of relatively open space comprising the living room, kitchen, and dining room, with a hallway leading to the bedrooms.\u003c\/p\u003e\n\u003cp\u003eSimply installing a larger unit does not guarantee that air will reach the bedrooms more effectively. In this type of project, the \u003cstrong\u003epositioning of the indoor unit\u003c\/strong\u003e can be just as important as its capacity.\u003c\/p\u003e\n\u003cp\u003eWe are particularly looking to achieve:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eadequate clearance in front of the heat pump;\u003c\/li\u003e\n\u003cli\u003ean air stream that travels through as much of the space as possible;\u003c\/li\u003e\n\u003cli\u003eas few obstacles as possible in front of the unit;\u003c\/li\u003e\n\u003cli\u003ereliable condensate drainage;\u003c\/li\u003e\n\u003cli\u003ea logical piping route;\u003c\/li\u003e\n\u003cli\u003ean outdoor location that facilitates maintenance;\u003c\/li\u003e\n\u003cli\u003esufficient space around the outdoor unit to preserve its heat exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA well-positioned 15,000 BTU SENVILLE can be much more suitable than an 18,000 BTU unit installed where air circulation is poor.\u003c\/p\u003e\n\u003ch3\u003eWinter performance: look at the available BTUs as the temperature drops\u003c\/h3\u003e\n\u003cp\u003eA statement such as “heating down to -25 °C” indicates an operating limit, but it does not necessarily mean that the heat pump delivers its \u003cstrong\u003e15,000 nominal BTU at -25 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is an important distinction for Quebec’s climate.\u003c\/p\u003e\n\u003cp\u003eThe certification data available for the \u003cstrong\u003eSENA-15HF-OG \/ SENA-15HF-IGG\u003c\/strong\u003e combination indicates approximately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e15,000 BTU\/h at 47 °F\u003c\/strong\u003e, or approximately 8 °C;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12,000 BTU\/h at 17 °F\u003c\/strong\u003e, or approximately -8 °C;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11,500 BTU\/h at 5 °F\u003c\/strong\u003e, or approximately -15 °C;\u003c\/li\u003e\n\u003cli\u003ea \u003cstrong\u003eCOP of 1.80 at 5 °F (-15 °C)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe system is classified as an \u003cstrong\u003eENERGY STAR model for cold climates\u003c\/strong\u003e in the corresponding certification data. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis provides a much more useful understanding of the appliance. At approximately \u003cstrong\u003e-15 °C\u003c\/strong\u003e, the heat pump still retains significant heating capacity, but this capacity is no longer identical to its nominal value of 15,000 BTU.\u003c\/p\u003e\n\u003cp\u003eIn a residence in Montreal or Laval, we must therefore consider the existing heating system, the building’s heat losses, and the outdoor design temperature before deciding what proportion of the heating can be entrusted to the heat pump.\u003c\/p\u003e\n\u003ch3\u003eSEER2 23.5: highly appealing cooling efficiency\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2 of 23.5\u003c\/strong\u003e places this 15,000 BTU AURA in an efficient category for a wall-mounted heat pump.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2\u003c\/strong\u003e represents seasonal cooling efficiency. The higher this figure, the less electricity the appliance generally needs to consume to provide a given amount of cooling under the test conditions specified by the standard.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eEER2 of 11.7\u003c\/strong\u003e complements this figure by indicating efficiency under a specific operating condition.\u003c\/p\u003e\n\u003cp\u003eFor the homeowner, actual savings will obviously depend on many factors: temperature setting, insulation, sun exposure, length of use, climate, the old appliance being replaced, and occupancy habits.\u003c\/p\u003e\n\u003ch3\u003eAn indoor unit capable of operating very quietly\u003c\/h3\u003e\n\u003cp\u003eFor an installation in a living room, office, or near a bedroom, the noise level deserves as much attention as the SEER2.\u003c\/p\u003e\n\u003cp\u003eAccording to the technical specifications, the indoor unit has advertised levels of:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e58.5 \/ 36.5 \/ 32.5 \/ 21 \/ 18 dB(A)\u003c\/strong\u003e according to the different fan speeds.\u003c\/p\u003e\n\u003cp\u003eThe stated minimum level reaches \u003cstrong\u003e18 dB(A)\u003c\/strong\u003e. The outdoor unit is rated at \u003cstrong\u003e57 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn practice, the location of the outdoor compressor remains important. On a balcony, near a bedroom, between two buildings, or near the neighboring property, we consider clearances, vibrations, and sound reflection before choosing the installation point.\u003c\/p\u003e\n\u003ch3\u003eDimensions to plan for before installation\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures approximately \u003cstrong\u003e33.39 in wide × 9.17 in deep × 11.81 in high\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit measures approximately \u003cstrong\u003e30.12 × 11.93 × 21.85 in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThese dimensions are useful when a homeowner wants to place the outdoor unit under a window, on a porch, or in a narrow side passage. They also make it possible to determine in advance whether a wall-mounted installation, a support bracket, or a ground base is the best solution.\u003c\/p\u003e\n\u003cp\u003eHowever, the appliance dimensions alone should not be used for planning: service clearances and airflow requirements must also be respected.\u003c\/p\u003e\n\u003ch3\u003eR454B and comes precharged with refrigerant\u003c\/h3\u003e\n\u003cp\u003eThis version of the SENVILLE AURA uses \u003cstrong\u003eR454B\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe documentation indicates a charge of \u003cstrong\u003e35.27 oz\u003c\/strong\u003e and a factory charge corresponding to approximately \u003cstrong\u003e24.6 ft or 7.5 m of piping\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSenville also specifies that an installation using a \u003cstrong\u003e50 ft\u003c\/strong\u003e kit requires an on-site adjustment to the refrigerant charge. Professional installation is required to achieve the expected operation and maintain the warranty. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, the length of the refrigerant line set is therefore not an administrative detail. We verify it before installation, especially when the indoor unit and outdoor unit need to be installed on different façades or several floors apart.\u003c\/p\u003e\n\u003ch3\u003eElectrical supply: 208\/230 V and a 15 A circuit according to the data sheet\u003c\/h3\u003e\n\u003cp\u003eThe SENA-15HF operates on a \u003cstrong\u003e208\/230 V single-phase, 60 Hz\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\u003cp\u003eThe Senville data sheet states:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage range: \u003cstrong\u003e187 to 253 V\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eMinimum circuit ampacity: \u003cstrong\u003e15 A\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eMaximum protection: \u003cstrong\u003e15 A\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eSpecified connection wiring: \u003cstrong\u003e14# × 4\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDuring an installation, we still need to inspect the existing electrical panel, the circuit routing, and the regulatory requirements applicable to the project. A value listed on a technical data sheet does not replace an actual inspection of the electrical installation.\u003c\/p\u003e\n\u003ch3\u003eApp and Alexa control\u003c\/h3\u003e\n\u003cp\u003eThe SENVILLE AURA 15,000 BTU documentation indicates \u003cstrong\u003eAlexa\u003c\/strong\u003e compatibility and includes an \u003cstrong\u003eAlexa USB module\u003c\/strong\u003e, in addition to the wireless remote control. The app-based control allows, among other things, settings to be changed remotely and schedules to be programmed. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a primary residence, this makes daily scheduling easier. For a cottage, office, or intermittently used dwelling, remote control can be even more relevant.\u003c\/p\u003e\n\u003ch3\u003eDiagnostics and leak detection\u003c\/h3\u003e\n\u003cp\u003eThe AURA series also features an \u003cstrong\u003eintegrated diagnostic and leak detection system\u003c\/strong\u003e. The goal is to allow the system to report certain anomalies and facilitate intervention when the unit is no longer operating normally. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis function obviously does not replace maintenance. A clogged filter, a blocked outdoor coil, a poorly maintained drain, or a unit exposed to poor installation conditions can still reduce performance.\u003c\/p\u003e\n\u003ch2\u003eAirGreen installation: the difference between buying a heat pump and obtaining a coherent HVAC system\u003c\/h2\u003e\n\u003ch3\u003eThe location is chosen before drilling\u003c\/h3\u003e\n\u003cp\u003eFor us, installing a \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e starts with the building, not the drill.\u003c\/p\u003e\n\u003cp\u003eWe check in particular:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe area and layout of the zone;\u003c\/li\u003e\n\u003cli\u003eair circulation between rooms;\u003c\/li\u003e\n\u003cli\u003esun exposure;\u003c\/li\u003e\n\u003cli\u003ethe possible placement of the indoor unit;\u003c\/li\u003e\n\u003cli\u003econdensate drainage;\u003c\/li\u003e\n\u003cli\u003ethe refrigerant line route;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit location;\u003c\/li\u003e\n\u003cli\u003ethe electrical supply;\u003c\/li\u003e\n\u003cli\u003efuture access for cleaning and servicing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis preparation reduces the risk of ending up with a technically functional heat pump that is poorly positioned or difficult to service.\u003c\/p\u003e\n\u003ch3\u003e12,000, 15,000, or 18,000 BTU: it should not be chosen at random\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e15,000 BTU\u003c\/strong\u003e size allows for more precise selection.\u003c\/p\u003e\n\u003cp\u003eA 12,000 BTU heat pump may be sufficient in a well-insulated space, whereas a slightly more demanding space may justify upgrading to 15,000 BTU. Conversely, choosing 18,000 BTU solely to have “some extra capacity” is not always desirable.\u003c\/p\u003e\n\u003cp\u003eAn oversized unit can reach its setpoint very quickly and reduce its periods of stable operation. In cooling mode, this can also affect dehumidification and comfort distribution.\u003c\/p\u003e\n\u003cp\u003eWe therefore prefer to select the capacity that matches the building rather than the highest capacity available.\u003c\/p\u003e\n\u003ch3\u003eWarranty: verify the exact terms of the installed version\u003c\/h3\u003e\n\u003cp\u003eThe Senville documentation provided for this \u003cstrong\u003eSENA-15HF\u003c\/strong\u003e indicates a warranty of \u003cstrong\u003e10 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSince warranty programs, registration requirements, and additional protections may vary, we confirm the applicable conditions when preparing the quote and supplying the equipment.\u003c\/p\u003e\n\u003ch3\u003eENERGY STAR, cold climate, and LogisVert\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENA-15HF-OG \/ SENA-15HF-IGG\u003c\/strong\u003e combination is ENERGY STAR certified and appears in the certification data as a cold-climate heat pump. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a \u003cstrong\u003eHydro-Québec LogisVert grant\u003c\/strong\u003e, however, you must always check the rules and current list at the time of installation. Hydro-Québec specifies that eligible models and financial assistance amounts may change and that, for installations completed since November 26, 2025, a heat pump must, among other requirements, be ENERGY STAR certified to qualify. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we therefore prefer to confirm the actual eligibility of the AHRI number and exact combination rather than display an amount that may no longer correspond to the conditions applicable on the installation date.\u003c\/p\u003e\n\u003ch3\u003eWho would find this SENVILLE AURA 15,000 BTU particularly appealing?\u003c\/h3\u003e\n\u003cp\u003eWe consider this capacity when a project involves, among other things:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea medium-sized open-concept area;\u003c\/li\u003e\n\u003cli\u003ea need slightly greater than what a 12,000 BTU unit can comfortably cover;\u003c\/li\u003e\n\u003cli\u003ea goal of \u003cstrong\u003eheating and cooling with the same appliance\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea need for operation in low outdoor temperatures;\u003c\/li\u003e\n\u003cli\u003ea preference for a high-efficiency heat pump;\u003c\/li\u003e\n\u003cli\u003ean interest in remote control;\u003c\/li\u003e\n\u003cli\u003ea location where a low indoor noise level is important.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt may be suitable for various residential and light commercial projects in \u003cstrong\u003eMontréal, Laval, Longueuil, Boucherville, the South Shore, the North Shore, and the Montérégie\u003c\/strong\u003e, provided that its capacity truly matches the building’s heating and cooling loads.\u003c\/p\u003e\n\u003ch3\u003eHave the SENVILLE AURA 15,000 BTU installed by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen Climatisation \u0026amp; Chauffage\u003c\/strong\u003e, we can help you determine whether the \u003cstrong\u003eSENVILLE AURA R454B 15,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is suitable for your space, determine the best locations for the units, plan the piping and drainage, and prepare a complete HVAC installation.\u003c\/p\u003e\n\u003cp\u003eTo obtain a price, check eligibility for available programs, or compare this unit with the 12,000 and 18,000 BTU models, contact us at \u003cstrong\u003e514-316-2973\u003c\/strong\u003e or \u003cstrong\u003e\u003ca class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003esales@airgreen.ca\u003c\/a\u003e\u003c\/strong\u003e. We serve \u003cstrong\u003eMontréal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119541760292,"sku":"SENA-15HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_AURA_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_595d2dfa-ff0e-43b8-86a9-e8f6d4047609.png?v=1789049523","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-senville-aura-r454b-15000-btu-montreal-rive-sud-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}