{"product_id":"thermopompe-murale-senville-aura-r454b-33000-btu-montreal-rive-sud-nord","title":"SENVILLE AURA R454B Wall-Mounted Heat Pump | 33000 BTU | Montréal, South Shore \u0026 North Shore","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA 33,000 BTU wall-mounted heat pump for large spaces where a smaller unit is no longer enough\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE AURA R454B 33,000 BTU\u003c\/strong\u003e immediately stands out from the 9,000, 12,000, or 18,000 BTU wall-mounted heat pumps found in many condos and homes throughout Greater Montréal. Here, we are dealing with a high-capacity single-zone unit designed to handle much larger air volumes and meet the needs of a large open-concept area, a spacious basement, a commercial space, a workshop, or certain residential layouts where a single wall-mounted head must cover a substantial area.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, when we assess a \u003cstrong\u003ewall-mounted heat pump in Montréal, Laval, Longueuil, on the North Shore or South Shore\u003c\/strong\u003e, we never stop at the 33,000 BTU figure. A high capacity may be exactly what is needed in a large open space, but it can also be excessive in a highly compartmentalized home. The real challenge is matching the unit's capacity to the building's heating and cooling load and, above all, to how air can actually circulate between areas.\u003c\/p\u003e\n\u003cp\u003eSenville documentation presents the SENA-33HF as a \u003cstrong\u003e33,000 BTU\u003c\/strong\u003e ductless heat pump, ENERGY STAR certified, capable of heating down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, with smart app and Alexa control. The manufacturer recommends it for spaces of approximately \u003cstrong\u003e1,500 to 1,750 sq. ft.\u003c\/strong\u003e, particularly large rooms and open-concept areas. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, this area is only a general guideline. A very open 1,600 sq. ft. home in Boucherville will not respond at all like a Montréal duplex of the same size divided into several bedrooms and hallways.\u003c\/p\u003e\n\u003ch3\u003eSENA-33HF-OG and SENA-33HF-IGG: the models to be correctly identified\u003c\/h3\u003e\n\u003cp\u003eThe combination presented by AirGreen includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: SENA-33HF-OG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: SENA-33HF-IGG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI number: 215735299\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR ID: 3630046\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal cooling capacity: 33,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWi-Fi: included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR certification: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR cold climate: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer's brochure identifies the technical family as \u003cstrong\u003eSENA-33HF\u003c\/strong\u003e and confirms that it is a ductless wall-mounted heat pump operating on a \u003cstrong\u003e208\/230 V single-phase, 60 Hz\u003c\/strong\u003e power supply. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor us, accurately identifying the indoor and outdoor units is essential during an installation, warranty claim, diagnosis, or rebate verification. Two devices bearing the same brand and similar capacity may have different AHRI data, winter performance, or electrical requirements.\u003c\/p\u003e\n\u003ch3\u003eA nominal 33,000 BTU does not mean 33,000 BTU continuously\u003c\/h3\u003e\n\u003cp\u003eOne of the main advantages of a modern inverter heat pump is its ability to modulate.\u003c\/p\u003e\n\u003cp\u003eThe SENVILLE SENA-33HF offers a cooling range of approximately \u003cstrong\u003e12,000 to 36,000 BTU\/h\u003c\/strong\u003e. In heating mode, the manufacturer's stated nominal capacity is \u003cstrong\u003e34,500 BTU\/h\u003c\/strong\u003e, with a modulation range of approximately \u003cstrong\u003e13,000 to 38,000 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis modulation is particularly important for a high-capacity wall-mounted heat pump. On a hot day in July, cooling demand may be high in the afternoon and then decrease considerably in the evening. The unit can then reduce its output instead of operating continuously at maximum capacity.\u003c\/p\u003e\n\u003cp\u003eIt should nevertheless be understood that a minimum of approximately 12,000 BTU in cooling mode remains high for a small room. That is why we avoid installing a \u003cstrong\u003e33,000 BTU heat pump\u003c\/strong\u003e in a space that is too small simply to obtain “more power.”\u003c\/p\u003e\n\u003ch3\u003eSEER2 of 19.5: how to interpret the performance of this large unit\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's technical documentation indicates a \u003cstrong\u003eSEER2 of 19.5\u003c\/strong\u003e and an \u003cstrong\u003eEER2 of 11.5\u003c\/strong\u003e. In heating mode, it lists an \u003cstrong\u003eHSPF2-4 of 10.5\u003c\/strong\u003e, an \u003cstrong\u003eHSPF2-5 of 8.5\u003c\/strong\u003e, and a nominal COP of \u003cstrong\u003e3.3\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a unit of this capacity, a SEER2 of 19.5 represents an interesting efficiency level, particularly when comparing the use of an inverter heat pump with older air-conditioning solutions that operate with much more pronounced on-off cycles.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer also claims potential annual energy savings of up to 50%. However, we prefer to present this figure with caution: actual consumption always depends on the equipment being replaced, insulation, setpoint temperatures, climate, operating hours, and building configuration. The brochure confirms the \u003cstrong\u003eSEER2 of 19.5\u003c\/strong\u003e, ENERGY STAR certification, and this manufacturer estimate. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eGenuine heating capacity for the Quebec climate\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet indicates heating operation down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, which is also confirmed by Senville documentation. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe information becomes much more useful when we look at the available capacity in cold temperatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e32,000 BTU\/h at -8 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e35,000 BTU\/h at -15 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eup to \u003cstrong\u003e20,700 BTU\/h at -30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese figures show why a heat pump should never be summarized solely by the claim “operates down to -30 °C.”\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e, the stated capacity remains very high. At \u003cstrong\u003e-30 °C\u003c\/strong\u003e, it drops to approximately 20,700 BTU\/h. At the same time, the building's heat loss increases as the outdoor temperature decreases.\u003c\/p\u003e\n\u003cp\u003eFor a homeowner in \u003cstrong\u003eLaval\u003c\/strong\u003e, Terrebonne, Longueuil, or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the essential question is therefore not just whether the machine continues to operate at -30 °C. We must determine whether the BTUs available at that temperature are still sufficient to meet the building's heating load.\u003c\/p\u003e\n\u003cp\u003eThis is exactly why we analyze heating needs before using a heat pump as the primary heat source.\u003c\/p\u003e\n\u003ch3\u003eAn indoor unit that moves a lot of air\u003c\/h3\u003e\n\u003cp\u003eAt this capacity, air circulation becomes a central factor in comfort.\u003c\/p\u003e\n\u003cp\u003eThe brochure indicates four indoor airflow rates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e890 CFM in Turbo mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e720 CFM at high speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e540 CFM at medium speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e410 CFM at low speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe indoor sound level ranges from \u003cstrong\u003e30 dB(A)\u003c\/strong\u003e at low speed to \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e in Turbo mode. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis high airflow explains why this unit can be effective in a large open space. It also explains why its location must be chosen intelligently.\u003c\/p\u003e\n\u003cp\u003eInstalling a 33,000 BTU indoor unit directly above a sofa, work table, or bed can create an unpleasant draft. Instead, we seek to use the length of the room and the geometry of the space to allow the airflow to develop.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications also indicate \u003cstrong\u003eautomatic control of the vertical and horizontal louvers\u003c\/strong\u003e, which improves air distribution in large rooms.\u003c\/p\u003e\n\u003ch3\u003eDimensions must be planned before installation\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures approximately \u003cstrong\u003e48.8 in wide × 11.2 in deep × 14.6 in high\u003c\/strong\u003e and weighs approximately \u003cstrong\u003e44.1 lb\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit is even larger—approximately \u003cstrong\u003e38.6 × 16.1 × 33.1 in\u003c\/strong\u003e, with a weight of approximately \u003cstrong\u003e140 lb\u003c\/strong\u003e. The stated outdoor sound level is \u003cstrong\u003e63 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore do not treat this model like a standard small wall-mounted heat pump.\u003c\/p\u003e\n\u003cp\u003eBefore a \u003cstrong\u003eheat pump installation in Montreal or Greater Montreal\u003c\/strong\u003e, we must check:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe actual width available for the indoor unit;\u003c\/li\u003e\n\u003cli\u003erequired clearances;\u003c\/li\u003e\n\u003cli\u003ethe strength of the mounting surface;\u003c\/li\u003e\n\u003cli\u003ethe route of the refrigerant lines;\u003c\/li\u003e\n\u003cli\u003ethe location of the outdoor unit;\u003c\/li\u003e\n\u003cli\u003epossible snow accumulation;\u003c\/li\u003e\n\u003cli\u003edrainage of water from defrost cycles;\u003c\/li\u003e\n\u003cli\u003efuture accessibility for maintenance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA 140-pound outdoor heat pump unit also requires a support suitable for the actual installation, whether it is a wall bracket, a base, or another approved solution.\u003c\/p\u003e\n\u003ch2\u003eWhat we check at AirGreen before installing a 33,000-BTU SENVILLE AURA\u003c\/h2\u003e\n\u003ch3\u003eA large area does not automatically mean a large heat pump\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer recommends this unit for approximately \u003cstrong\u003e1,500 to 1,750 square feet\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe use this information as a reference point, never as the sole sizing method.\u003c\/p\u003e\n\u003cp\u003eLet us consider two very different scenarios.\u003c\/p\u003e\n\u003cp\u003eIn a 1,500-square-foot open-plan area with a living room, kitchen, and dining room that are practically without partitions, a high-capacity ductless heat pump can benefit from good air distribution.\u003c\/p\u003e\n\u003cp\u003eIn a 1,500-square-foot home consisting of four bedrooms, two hallways, and several doors, installing a single 33,000-BTU head in the living room absolutely does not guarantee that every bedroom will reach the desired temperature.\u003c\/p\u003e\n\u003cp\u003eThe cooling capacity may be sufficient on paper, while the real problem is \u003cstrong\u003eair distribution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is a situation we regularly encounter in the \u003cstrong\u003eHVAC industry in Montreal and the North and South Shore suburbs\u003c\/strong\u003e: increasing BTUs does not replace a good air-distribution strategy.\u003c\/p\u003e\n\u003ch3\u003eA particularly interesting application for large open spaces\u003c\/h3\u003e\n\u003cp\u003eThis SENVILLE AURA may be suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea large open main floor;\u003c\/li\u003e\n\u003cli\u003ea large basement;\u003c\/li\u003e\n\u003cli\u003ea loft;\u003c\/li\u003e\n\u003cli\u003ea workshop;\u003c\/li\u003e\n\u003cli\u003ecertain commercial rooms;\u003c\/li\u003e\n\u003cli\u003ean open-plan office;\u003c\/li\u003e\n\u003cli\u003ea large multipurpose room;\u003c\/li\u003e\n\u003cli\u003ecertain homes where the staircase and openings naturally promote air movement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe recommend it much more cautiously in a home with many separate rooms.\u003c\/p\u003e\n\u003cp\u003eIn some cases, two smaller, well-placed units can provide better comfort than a single very large heat pump, even when their total capacity is similar.\u003c\/p\u003e\n\u003ch3\u003e3\/8-inch–3\/4-inch piping: a larger-diameter installation\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specifications sheet lists 3\/8-inch–3\/4-inch refrigerant piping.\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-inch diameter on the gas side is significantly larger than that used on many small-capacity ductless heat pumps. It affects route planning, bends, wall penetrations, and the cost of an installation involving long piping runs.\u003c\/p\u003e\n\u003cp\u003eThe brochure also specifies that the system uses \u003cstrong\u003eR-454B\u003c\/strong\u003e, with a listed charge of \u003cstrong\u003e68.4 oz\u003c\/strong\u003e, and that it is precharged for a line length of up to \u003cstrong\u003e25 feet\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSenville specifies that an installation with a 50-foot line set requires additional refrigerant to be added on-site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eR-454B is an A2L refrigerant. The installation must therefore comply with the methods, equipment, and procedures applicable to this new generation of refrigerants.\u003c\/p\u003e\n\u003ch3\u003eWhy proper evacuation remains essential\u003c\/h3\u003e\n\u003cp\u003eA heat pump may operate after a poor installation without necessarily showing an obvious fault immediately.\u003c\/p\u003e\n\u003cp\u003eThis is precisely what makes certain errors costly.\u003c\/p\u003e\n\u003cp\u003eAn improperly prepared refrigerant line may contain moisture or contaminants. Improper evacuation, a leak at a connection, or an incorrect charge can affect performance, power consumption, and potentially compressor longevity.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, \u003cstrong\u003eHVAC commissioning\u003c\/strong\u003e is therefore an integral part of installation quality, on an equal footing with the physical securing of the units.\u003c\/p\u003e\n\u003ch3\u003eDrainage: 3.5 liters per hour must not be ignored\u003c\/h3\u003e\n\u003cp\u003eThe technical data sheet indicates a dehumidification capacity of approximately \u003cstrong\u003e3.5 L\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDuring Montreal's hot and humid season, a heat pump of this capacity can therefore produce a significant amount of condensate.\u003c\/p\u003e\n\u003cp\u003eThe drain must be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eproperly sized;\u003c\/li\u003e\n\u003cli\u003einstalled with a sufficient slope when gravity drainage is used;\u003c\/li\u003e\n\u003cli\u003eprotected against backflow;\u003c\/li\u003e\n\u003cli\u003epositioned so as not to cause damage to the facade or around the foundation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA fully functional heat pump can become a source of water damage if drainage has been neglected.\u003c\/p\u003e\n\u003ch3\u003eElectrical requirements: 34 A MCA and maximum protection of 35 A\u003c\/h3\u003e\n\u003cp\u003eThis unit is much more electrically demanding than a small wall-mounted heat pump.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's documentation states:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epower supply \u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003evoltage range \u003cstrong\u003e187 to 253 V\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMCA: 34 A\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003emaximum protection: \u003cstrong\u003e35 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values must be taken into account from the quotation stage.\u003c\/p\u003e\n\u003cp\u003eIn some older homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e, especially when the electrical panel is already heavily loaded by electric heating, the water heater, the stove, and other equipment, we must verify whether the electrical installation can accommodate the addition of the heat pump under suitable conditions.\u003c\/p\u003e\n\u003cp\u003eThe connection wiring between the units is indicated in \u003cstrong\u003e14 × 4 AWG\u003c\/strong\u003e in the brochure. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis communication\/interconnection cable must not be confused with the complete sizing of the electrical power circuit. The latter must be carried out according to the nameplate data and the requirements applicable to the installation.\u003c\/p\u003e\n\u003ch3\u003eWiFi and Alexa: especially useful when the space has variable schedules\u003c\/h3\u003e\n\u003cp\u003eThe SENVILLE AURA is compatible with smart control via an app and Alexa.\u003c\/p\u003e\n\u003cp\u003eAccording to the brochure, it is possible to adjust the settings remotely and schedule operating times. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a commercial space, workshop, or office, this feature can be particularly practical. The setpoint can be lowered after business hours and a comfortable level restored before occupants arrive.\u003c\/p\u003e\n\u003cp\u003eThe brochure also indicates the presence of \u003cstrong\u003eself-diagnostic and leak-detection functions\u003c\/strong\u003e, intended to facilitate the identification of certain operating problems. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese features obviously do not replace a diagnosis by a refrigeration technician when the unit no longer heats properly, makes noise, frosts abnormally, or displays an error code.\u003c\/p\u003e\n\u003ch3\u003eWarranty: information to be confirmed at the time of purchase\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen sheet provided for this combination indicates a warranty of:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10 years compressor – 10 years parts – 0 years labor.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe attached Senville brochure nevertheless provides different information: \u003cstrong\u003e10 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis difference must be clarified before purchase.\u003c\/p\u003e\n\u003cp\u003eWarranty programs may depend on the seller, equipment registration, distribution channel, or specific conditions. We prefer to confirm the exact coverage applicable to the equipment sold by AirGreen rather than assume that a generic manufacturer’s warranty automatically applies.\u003c\/p\u003e\n\u003ch3\u003eDisplayed LogisVert subsidy: $3,840\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet provided with this model lists a \u003cstrong\u003e$3,840 LogisVert provincial subsidy\u003c\/strong\u003e, with an update dated \u003cstrong\u003eNovember 26, 2025\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis information is particularly relevant for a 33,000 BTU unit, since the financial assistance can have a major impact on the project’s net cost.\u003c\/p\u003e\n\u003cp\u003eHowever, a subsidy is never determined solely by the brand or nominal capacity. Eligibility may depend on the exact combination of equipment, the AHRI number, the building, and the program rules in effect at the time of installation.\u003c\/p\u003e\n\u003cp\u003eWe therefore always recommend confirming the applicable amount before making a final decision.\u003c\/p\u003e\n\u003ch3\u003eThe mistake we want to avoid: choosing 33,000 BTU solely to “be sure”\u003c\/h3\u003e\n\u003cp\u003eIn the field, oversizing a heat pump can sometimes seem reassuring.\u003c\/p\u003e\n\u003cp\u003eA homeowner may think that a larger unit will heat faster and will therefore necessarily be better. In reality, the goal of an efficient installation is to have the \u003cstrong\u003eright capacity\u003c\/strong\u003e, not simply the highest one.\u003c\/p\u003e\n\u003cp\u003eAn oversized heat pump can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eshorten cycle times;\u003c\/li\u003e\n\u003cli\u003ereduce dehumidification quality under certain conditions;\u003c\/li\u003e\n\u003cli\u003ecreate stronger drafts;\u003c\/li\u003e\n\u003cli\u003ecost more to install;\u003c\/li\u003e\n\u003cli\u003erequire a higher power supply;\u003c\/li\u003e\n\u003cli\u003eprovide poor temperature distribution when the problem is architectural rather than related to BTUs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE AURA 33,000 BTU\u003c\/strong\u003e is therefore an excellent candidate when there is a genuinely significant heat load and enough space to use its airflow properly.\u003c\/p\u003e\n\u003ch3\u003eWhy entrust this installation to AirGreen\u003c\/h3\u003e\n\u003cp\u003eA 33,000 BTU heat pump requires more preparation than a small bedroom unit.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we analyze the project as a whole:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecapacity actually required;\u003c\/li\u003e\n\u003cli\u003eindoor unit location;\u003c\/li\u003e\n\u003cli\u003eairflow reach;\u003c\/li\u003e\n\u003cli\u003eelectrical supply;\u003c\/li\u003e\n\u003cli\u003erefrigerant line lengths;\u003c\/li\u003e\n\u003cli\u003edrainage;\u003c\/li\u003e\n\u003cli\u003eclearances;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit support;\u003c\/li\u003e\n\u003cli\u003efuture access for maintenance;\u003c\/li\u003e\n\u003cli\u003ewinter performance;\u003c\/li\u003e\n\u003cli\u003epotential eligibility for rebates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe perform \u003cstrong\u003eheat pump installations in Montreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e, using an approach focused equally on actual performance and the visual quality of the installation.\u003c\/p\u003e\n\u003cp\u003eIn a large open-concept area, a well-positioned unit can make a major difference. Conversely, an excellent heat pump installed in the wrong location can leave part of the building uncomfortable despite having more than sufficient rated capacity.\u003c\/p\u003e\n\u003ch3\u003eOur verdict on the SENVILLE AURA R454B 33,000 BTU\u003c\/h3\u003e\n\u003cp\u003eThis SENVILLE occupies a distinctive position in the wall-mounted heat pump range.\u003c\/p\u003e\n\u003cp\u003eIts appeal comes from the combination of several elements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e33,000 BTU in cooling\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003erated heating capacity of \u003cstrong\u003e34,500 BTU\u003c\/strong\u003e according to the brochure;\u003c\/li\u003e\n\u003cli\u003ecapacity modulation up to \u003cstrong\u003e36,000 BTU in cooling\u003c\/strong\u003e and \u003cstrong\u003e38,000 BTU in heating\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 of 19.5\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eheating down to -30 °C\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR Cold Climate\u003c\/strong\u003e certification;\u003c\/li\u003e\n\u003cli\u003eWiFi and Alexa;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant;\u003c\/li\u003e\n\u003cli\u003eindoor airflow of up to \u003cstrong\u003e890 CFM\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eimpressive winter performance down to very low temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHowever, it must be selected for the right reasons. The fact that a unit can technically cover a large area does not mean that it can distribute its air effectively throughout several closed rooms.\u003c\/p\u003e\n\u003cp\u003eFor a properly configured large open-concept area, this \u003cstrong\u003e33,000 BTU wall-mounted heat pump\u003c\/strong\u003e can be a highly suitable solution. For a more complex property, we can also determine whether a different capacity or configuration would provide greater comfort.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre you considering the SENVILLE AURA R454B 33,000 BTU for your home, business, basement, or large open-concept area? Contact AirGreen for a quote and a complete assessment of your project. We serve Montreal, Laval, Longueuil, the North Shore, and the South Shore for the sale, installation, maintenance, and servicing of wall-mounted heat pumps.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119541891364,"sku":"SENA-33HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_AURA_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_74c7c79d-5e10-49c1-a5b0-a1e30932ece2.png?v=1789049533","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-senville-aura-r454b-33000-btu-montreal-rive-sud-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}