{"product_id":"thermopompe-murale-senville-aura-r454b-6000-btu-montreal-rive-sud-nord","title":"SENVILLE AURA R454B Wall-Mounted Heat Pump | 6000 BTU | Montréal, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 6,000 BTU heat pump designed for small rooms, with no compromise on performance in Quebec's climate\u003c\/h2\u003e\n\u003cp\u003eA \u003cstrong\u003e6,000 BTU\u003c\/strong\u003e wall-mounted heat pump meets a very specific need: efficiently heating and cooling a small area without installing an unnecessarily oversized unit. The \u003cstrong\u003eSENVILLE AURA R454B 6,000 BTU\u003c\/strong\u003e stands out precisely for its ability to modulate well below and above its rated capacity, operate down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, provide high seasonal efficiency, offer WiFi connectivity, and run on a 208\/230 V power supply.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we place great importance on this category of heat pumps. In \u003cstrong\u003eMontréal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e, many bedrooms, enclosed offices, small apartments, extensions, and targeted spaces do not need a 12,000 BTU heat pump. In these situations, a properly sized unit can provide better temperature control, more stable operation, and superior acoustic comfort.\u003c\/p\u003e\n\u003cp\u003eSenville's documentation identifies this unit as belonging to the \u003cstrong\u003eAURA SENA-06HF\u003c\/strong\u003e series, with a rated cooling capacity of 6,000 BTU. The manufacturer recommends it for rooms of approximately \u003cstrong\u003e100 to 250 sq. ft.\u003c\/strong\u003e and specifies that professional installation is required. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eThe essential features of the 6,000 BTU SENVILLE AURA\u003c\/h3\u003e\n\u003cp\u003eOn our AirGreen page, the combination is identified as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: SENA-06HF-OG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: SENA-06HF-IGG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI: 215735294\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated cooling capacity: 6,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR®: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR® Cold Climate: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heating temperature: -30 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWiFi: included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant piping: 1\/4 in – 3\/8 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 220 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 12 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum overcurrent protection: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVertical louvers: automatic\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHorizontal louvers: automatic\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor sound level: 22 to 44 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor sound level: 53 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer's technical documentation specifically confirms a \u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e power supply, a voltage range of 187 to 253 V, a \u003cstrong\u003eSEER2 of 25.5\u003c\/strong\u003e, an \u003cstrong\u003eEER2 of 18\u003c\/strong\u003e, a modulating cooling capacity of \u003cstrong\u003e2,300 to 12,600 BTU\/h\u003c\/strong\u003e, and a rated heating capacity of 7,000 BTU\/h with modulation from \u003cstrong\u003e3,000 to 11,000 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis modulation range deserves particular attention. An inverter heat pump is not a unit that constantly operates at exactly 6,000 BTU. It adjusts its output according to demand. In a small bedroom that is gradually approaching the set temperature, the compressor can reduce its speed rather than simply stopping and restarting constantly.\u003c\/p\u003e\n\u003ch3\u003eSEER2 25.5: particularly impressive efficiency for a small wall-mounted heat pump\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE AURA 6,000 BTU\u003c\/strong\u003e has a \u003cstrong\u003eSEER2 of 25.5\u003c\/strong\u003e and an \u003cstrong\u003eEER2 of 18\u003c\/strong\u003e, according to the manufacturer's documentation. The same document indicates an \u003cstrong\u003eHSPF2-4 of 14.8\u003c\/strong\u003e, an \u003cstrong\u003eHSPF2-5 of 11.5\u003c\/strong\u003e, and a stated nominal COP of 4.2. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor homeowners, these figures are mainly useful for comparing units with similar capacities. SEER2 represents seasonal cooling efficiency, while HSPF2 concerns heating. The value of a heat pump like the AURA therefore lies not only in its ability to produce heat at low temperatures, but also in its ability to operate efficiently during the many hours when the outdoor temperature is much milder.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications also provide particularly useful data for our climate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e8,700 BTU\/h at -8 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7,700 BTU\/h at -15 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3,200 BTU\/h maximum at -30 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese figures help illustrate an important reality. The statement “heating down to -30 °C” does not mean that the unit maintains its full rated heating capacity at -30 °C. As with virtually any heat pump, its available capacity decreases as the cold becomes extreme.\u003c\/p\u003e\n\u003cp\u003eThat is precisely why, at AirGreen, we never recommend a heat pump based solely on the minimum temperature listed on the specification sheet. \u003cstrong\u003eRoom sizing and heat loss remain essential.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eA 6,000 BTU capacity that must be used in the right place\u003c\/h3\u003e\n\u003cp\u003eAccording to Senville, this unit is suitable for spaces of approximately \u003cstrong\u003e100 to 250 sq. ft.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e However, square footage is only a starting point.\u003c\/p\u003e\n\u003cp\u003eFor an installation in \u003cstrong\u003eMontréal, Laval, Longueuil, Boucherville, Terrebonne, Repentigny, or elsewhere on the South Shore and North Shore\u003c\/strong\u003e, we must also consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eceiling height;\u003c\/li\u003e\n\u003cli\u003ethe number and area of the windows;\u003c\/li\u003e\n\u003cli\u003etheir orientation;\u003c\/li\u003e\n\u003cli\u003einsulation quality;\u003c\/li\u003e\n\u003cli\u003ethe floor where the room is located;\u003c\/li\u003e\n\u003cli\u003eexterior-facing walls;\u003c\/li\u003e\n\u003cli\u003eair infiltration;\u003c\/li\u003e\n\u003cli\u003eair circulation toward adjacent rooms;\u003c\/li\u003e\n\u003cli\u003eactual space usage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA well-insulated 180 sq. ft. bedroom in a recent construction does not necessarily have the same needs as a room of the same size located on the top floor of an older building with a large south-facing window.\u003c\/p\u003e\n\u003cp\u003eIt is also a mistake to consider a \u003cstrong\u003e6,000 BTU\u003c\/strong\u003e heat pump an automatic solution for an open-plan space simply because its maximum cooling capacity can temporarily rise far above 6,000 BTU.\u003c\/p\u003e\n\u003ch3\u003eAn inverter heat pump that modulates between 2,300 and 12,600 BTU in cooling mode\u003c\/h3\u003e\n\u003cp\u003eThe official cooling range is \u003cstrong\u003e2,300 to 12,600 BTU\/h\u003c\/strong\u003e, while the heating range is \u003cstrong\u003e3,000 to 11,000 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an important advantage in a small room.\u003c\/p\u003e\n\u003cp\u003eConsider a typical example: a closed office quickly reaches 23 °C after the air conditioner starts. An improperly sized unit might stop its compressor, allow the temperature to rise, and then restart a few minutes later.\u003c\/p\u003e\n\u003cp\u003eAn inverter system capable of greatly reducing its output can instead operate at low capacity to maintain a more consistent temperature.\u003c\/p\u003e\n\u003cp\u003eFor the occupant, this may mean:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003efewer temperature fluctuations;\u003c\/li\u003e\n\u003cli\u003efewer abrupt starts;\u003c\/li\u003e\n\u003cli\u003egreater comfort stability;\u003c\/li\u003e\n\u003cli\u003ereduced noise at low speed;\u003c\/li\u003e\n\u003cli\u003emore gradual humidity management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOnly 22 dB(A) at low indoor speed\u003c\/h3\u003e\n\u003cp\u003eFor a bedroom or office, indoor unit noise often becomes just as important as its capacity.\u003c\/p\u003e\n\u003cp\u003eThe documentation indicates four airflow levels:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eIndoor airflow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbo\u003c\/td\u003e\n\u003ctd\u003e382.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh\u003c\/td\u003e\n\u003ctd\u003e323.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003e229.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003e176.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe corresponding sound pressure levels are \u003cstrong\u003e44.0 \/ 36.5 \/ 32.5 \/ 22.0 dB(A)\u003c\/strong\u003e. The outdoor unit is rated at \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e22 dB(A)\u003c\/strong\u003e level at low speed is particularly appealing when a wall-mounted unit needs to operate overnight.\u003c\/p\u003e\n\u003cp\u003eHowever, location remains decisive. Installing an indoor unit directly above the head of the bed or directing its main airflow toward a workstation can cause discomfort even with a quiet appliance. When planning an installation at AirGreen, we therefore seek, whenever possible, a location that allows good air distribution throughout the room.\u003c\/p\u003e\n\u003ch3\u003eCompact dimensions for the indoor and outdoor units\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures approximately:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e33.40 in. wide × 9.18 in. deep × 11.76 in. high\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eand weighs approximately \u003cstrong\u003e22.93 lb\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit measures:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e30.12 in × 11.93 in × 21.85 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003efor a weight of approximately \u003cstrong\u003e62.17 lb\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese dimensions make it easier to integrate the system into several projects where available space is limited, particularly in condos, small duplexes, bedrooms, or offices.\u003c\/p\u003e\n\u003cp\u003eNevertheless, we must maintain the required technical clearances around the outdoor unit. A heat pump must not be enclosed in an overly confined space solely to make it less visible.\u003c\/p\u003e\n\u003ch3\u003eR-454B: the new generation of refrigerant used by this AURA\u003c\/h3\u003e\n\u003cp\u003eThis version uses \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e. The manufacturer indicates a charge of \u003cstrong\u003e32.45 oz\u003c\/strong\u003e and a factory charge intended for piping up to \u003cstrong\u003e25 feet\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications indicate 1\/4 in – 3\/8 in piping.\u003c\/p\u003e\n\u003cp\u003eThis is essential information when replacing an existing heat pump. We never assume that old piping can automatically be reused because it “looks like” the new one. Its diameter, condition, routing, and compatibility must be verified.\u003c\/p\u003e\n\u003cp\u003eSenville's documentation also specifies that a 50-foot configuration requires an additional amount of refrigerant to be added on site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eA relatively light electrical supply: MCA 12 A and maximum protection of 15 A\u003c\/h3\u003e\n\u003cp\u003eFor this unit, the technical documentation provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e208\/230 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003esingle-phase\u003c\/li\u003e\n\u003cli\u003e60 Hz\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 12 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003emaximum fuse or circuit breaker: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003especified connection wiring: \u003cstrong\u003e14\/4 AWG\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe relatively small capacity of this heat pump can therefore simplify certain electrical projects compared with much higher-capacity units.\u003c\/p\u003e\n\u003cp\u003eHowever, this does not eliminate the need to verify the existing electrical installation. At AirGreen, we want the protection, wiring, disconnect switch, and power supply to be suitable for the model actually installed.\u003c\/p\u003e\n\u003ch2\u003eInstallation, WiFi, and everyday use: what we check at AirGreen\u003c\/h2\u003e\n\u003ch3\u003eBuilt-in WiFi and Alexa compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE AURA 6,000 BTU\u003c\/strong\u003e has built-in WiFi and can be controlled from an iOS or Android device. The documentation also confirms its compatibility with \u003cstrong\u003eAmazon Alexa\u003c\/strong\u003e, particularly for adjusting the temperature remotely and creating certain routines. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis becomes particularly useful for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea secondary residence;\u003c\/li\u003e\n\u003cli\u003ean office used only on certain days;\u003c\/li\u003e\n\u003cli\u003ea guest bedroom;\u003c\/li\u003e\n\u003cli\u003ea dwelling where you want to adjust the temperature before arrival;\u003c\/li\u003e\n\u003cli\u003ea room located on another floor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe remote control also has the \u003cstrong\u003eFollow Me\u003c\/strong\u003e function, which uses the sensor built into the remote control as the temperature reference point. The manufacturer also mentions a dehumidification function, a silver-ion filter, and a refrigerant leak detection system. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eDehumidification, self-cleaning, and diagnostics\u003c\/h3\u003e\n\u003cp\u003eIn cooling mode, comfort depends not only on temperature. In Montreal and the greater metropolitan area, hot periods can also be very humid.\u003c\/p\u003e\n\u003cp\u003eThe technical specifications indicate a moisture-removal capacity of \u003cstrong\u003e0.3 L\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AURA series also includes several functions intended for operation and maintenance:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eself-cleaning mode;\u003c\/li\u003e\n\u003cli\u003eleak detection;\u003c\/li\u003e\n\u003cli\u003eself-diagnostic system;\u003c\/li\u003e\n\u003cli\u003ediagnostic display;\u003c\/li\u003e\n\u003cli\u003edehumidification function;\u003c\/li\u003e\n\u003cli\u003esilver-ion filter;\u003c\/li\u003e\n\u003cli\u003ePTC heating element for the outdoor area;\u003c\/li\u003e\n\u003cli\u003eoperation in low-temperature cooling mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese functions are described in Senville’s documentation as tools for more quickly identifying certain operating problems and facilitating system maintenance. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, they do not replace physical maintenance of the unit. The filters must be cleaned, the evaporator must remain clean, the drain must properly remove condensate, and the outdoor unit must maintain adequate airflow.\u003c\/p\u003e\n\u003ch3\u003eThree mistakes we want to avoid with a 6,000 BTU heat pump\u003c\/h3\u003e\n\u003ch4\u003e1. Choosing 6,000 BTU for a room that is far too large\u003c\/h4\u003e\n\u003cp\u003eThe small capacity is an advantage when it genuinely matches the needs. It becomes a problem when attempting to cool a large open area, several rooms, or an entire floor with a single unit designed for a limited area.\u003c\/p\u003e\n\u003cp\u003eIn this case, the unit may operate continuously at high capacity without evenly reaching the desired temperature.\u003c\/p\u003e\n\u003ch4\u003e2. Installing the unit in the wrong location\u003c\/h4\u003e\n\u003cp\u003eA maximum airflow of \u003cstrong\u003e382.6 CFM\u003c\/strong\u003e can be very comfortable when the air is distributed properly, but much less pleasant when it blows directly onto the bed, sofa, or desk.\u003c\/p\u003e\n\u003cp\u003eWe therefore consider the room’s layout, not just where it is physically easiest to run the piping.\u003c\/p\u003e\n\u003ch4\u003e3. Neglecting drainage\u003c\/h4\u003e\n\u003cp\u003eIn cooling and dehumidification mode, the indoor unit produces condensate. The drain must be installed with an appropriate slope when gravity drainage is used.\u003c\/p\u003e\n\u003cp\u003eAn installation that works perfectly on the day it is commissioned can become problematic if the drainage was poorly planned.\u003c\/p\u003e\n\u003ch3\u003eAn example of a configuration in which this SENVILLE AURA truly makes sense\u003c\/h3\u003e\n\u003cp\u003eA common scenario in Greater Montreal is a bedroom or enclosed office of approximately 150 to 220 sq. ft. that becomes noticeably warmer in summer than the rest of the property.\u003c\/p\u003e\n\u003cp\u003eAutomatically installing a 12,000 BTU heat pump in this type of room may be excessive. The SENVILLE AURA 6,000 BTU, on the other hand, offers a particularly useful modulation range for maintaining a small area at a stable temperature.\u003c\/p\u003e\n\u003cp\u003eIn a bedroom, the minimum sound level of \u003cstrong\u003e22 dB(A)\u003c\/strong\u003e is also a practical advantage.\u003c\/p\u003e\n\u003cp\u003eIn an office, Wi-Fi, inverter modulation, and independent temperature control tend to become the priorities.\u003c\/p\u003e\n\u003cp\u003eThis type of analysis allows us at AirGreen to recommend capacity based on the room's actual use rather than relying solely on a BTU figure.\u003c\/p\u003e\n\u003ch3\u003eDown to -30 °C, but with capacity decreasing in extreme cold\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's documentation confirms a minimum heating temperature of \u003cstrong\u003e-22 °F \/ -30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOn our AirGreen product sheet, the capacity at very low temperatures is specified in greater detail:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e8,700 BTU\/h at -8 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7,700 BTU\/h at -15 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3,200 BTU\/h maximum at -30 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is an essential distinction for a Quebec homeowner.\u003c\/p\u003e\n\u003cp\u003eA heat pump capable of operating at -30 °C may continue to produce heat, but that does not necessarily mean it will be able to cover 100% of a room's heat loss when the outdoor temperature reaches that level.\u003c\/p\u003e\n\u003cp\u003eFor this reason, we always evaluate the heat pump based on the building, rather than solely on its minimum operating temperature.\u003c\/p\u003e\n\u003ch3\u003eWarranty: a discrepancy to verify between the AirGreen product sheet and Senville documentation\u003c\/h3\u003e\n\u003cp\u003eThe product sheet currently published by AirGreen indicates a warranty of \u003cstrong\u003e10 years on the compressor – 10 years on parts – 0 years on labor\u003c\/strong\u003e, with the possibility of additional coverage.\u003c\/p\u003e\n\u003cp\u003eThe Senville documentation supplied with the product, for its part, states \u003cstrong\u003e10 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBecause conditions may vary depending on the applicable program, registration, distribution channel, or commercial terms in effect, we recommend confirming the exact warranty that will appear on your AirGreen quote at the time of purchase.\u003c\/p\u003e\n\u003cp\u003eThis verification prevents comparing two heat pumps based on a warranty that would not actually apply to the project in question.\u003c\/p\u003e\n\u003ch3\u003eWho do we primarily recommend the SENVILLE AURA 6,000 BTU to?\u003c\/h3\u003e\n\u003cp\u003eThis heat pump deserves particular consideration for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea \u003cstrong\u003esmall bedroom\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea \u003cstrong\u003eclosed office\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea small room in a condo;\u003c\/li\u003e\n\u003cli\u003ea space of approximately \u003cstrong\u003e100 to 250 sq. ft.\u003c\/strong\u003e, subject to an actual load calculation;\u003c\/li\u003e\n\u003cli\u003ea room where quiet operation is a priority;\u003c\/li\u003e\n\u003cli\u003ea project where an \u003cstrong\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e heat pump is desired;\u003c\/li\u003e\n\u003cli\u003ea homeowner wanting \u003cstrong\u003ebuilt-in WiFi\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea project requiring a small unit on a 208\/230 V power supply;\u003c\/li\u003e\n\u003cli\u003ean area where a 9,000 or 12,000 BTU heat pump would be unnecessarily large.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConversely, if you want to condition a large open-concept area, several connected bedrooms, or an entire floor, we will compare this 6,000 BTU unit with higher-capacity AURA models before finalizing the selection.\u003c\/p\u003e\n\u003ch3\u003eWhy entrust the installation of your SENVILLE AURA to AirGreen?\u003c\/h3\u003e\n\u003cp\u003eA heat pump with a \u003cstrong\u003eSEER2 of 25.5\u003c\/strong\u003e will deliver the expected results only if the installation meets the system's requirements.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e, we can handle your project throughout \u003cstrong\u003eGreater Montréal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e, from capacity assessment through installation and commissioning.\u003c\/p\u003e\n\u003cp\u003eWe specifically check:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe actual room size;\u003c\/li\u003e\n\u003cli\u003eindoor unit location;\u003c\/li\u003e\n\u003cli\u003eair circulation;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit placement;\u003c\/li\u003e\n\u003cli\u003ethe \u003cstrong\u003e1\/4 in – 3\/8 in\u003c\/strong\u003e piping route;\u003c\/li\u003e\n\u003cli\u003econdensate drainage;\u003c\/li\u003e\n\u003cli\u003epiping length;\u003c\/li\u003e\n\u003cli\u003eelectrical requirements;\u003c\/li\u003e\n\u003cli\u003ethe required clearances;\u003c\/li\u003e\n\u003cli\u003efuture access for HVAC maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis step is particularly important with a small-capacity heat pump. The goal is not to sell more BTUs, but to install the capacity that truly matches the building.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre you considering the SENVILLE AURA R454B 6,000 BTU? Contact AirGreen for a quote and to confirm whether this capacity is truly suitable for your bedroom, office, or space in Montréal, Laval, Longueuil, the South Shore, or the North Shore. We can also compare it with the 9,000, 12,000, 15,000, 18,000, or 24,000 BTU versions according to your property's needs.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119541629220,"sku":"SENA-06HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_AURA_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1789049505","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-senville-aura-r454b-6000-btu-montreal-rive-sud-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}