{"product_id":"thermopompe-murale-senville-aura-r454b-9000-btu-montreal-rive-sud-nord","title":"SENVILLE AURA R454B Wall-Mounted Heat Pump | 9000 BTU | Montréal, South Shore \u0026 North Shore","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA 9,000 BTU heat pump designed for spaces where sizing, quiet operation, and performance truly matter\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE AURA R454B 9,000 BTU\u003c\/strong\u003e falls into a particularly interesting category for homeowners looking to cool and heat a room, a compact floor, or a clearly defined area without installing an unnecessarily oversized wall-mounted heat pump. For a bedroom, home office, small condo, studio, addition, or certain rooms that are difficult to balance with the main heating system, its capacity may correspond much more accurately to the building's actual load.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, when we assess a \u003cstrong\u003ewall-mounted heat pump installation in Montreal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/strong\u003e, we never choose a capacity based solely on square footage. Insulation, sun exposure, the number of windows, ceiling height, floor level, room location, and heat loss in winter all have a direct effect on sizing.\u003c\/p\u003e\n\u003cp\u003eFor the SENVILLE AURA, the manufacturer recommends the 9,000 BTU model for spaces of approximately \u003cstrong\u003e100 to 450 sq. ft.\u003c\/strong\u003e The brochure also specifies that it is a ductless heat pump certified by ENERGY STAR and designed to operate in heating mode down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis floor-area range is therefore a starting point, not an absolute rule. A 400 sq. ft. room with extensive glazing in Montreal does not necessarily have the same thermal load as a newer, well-insulated 400 sq. ft. room in Boucherville.\u003c\/p\u003e\n\u003ch3\u003eA modulating capacity that matters more than a simple “9,000 BTU”\u003c\/h3\u003e\n\u003cp\u003eThe figure of \u003cstrong\u003e9,000 BTU\u003c\/strong\u003e corresponds to the nominal cooling capacity. However, the heat pump does not operate continuously at this output.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's technical table, on page 4 of the brochure, indicates a cooling range of \u003cstrong\u003e3,000 to 10,500 BTU\/h\u003c\/strong\u003e and a nominal heating capacity of \u003cstrong\u003e9,800 BTU\/h\u003c\/strong\u003e, with modulation of approximately \u003cstrong\u003e3,100 to 11,000 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis modulation is important in a small room.\u003c\/p\u003e\n\u003cp\u003eA traditional heat pump that is too large for the space could quickly reach the desired temperature, shut off, restart, and then repeat the cycle. A properly sized inverter system can instead gradually reduce its output as the load decreases. This promotes a more consistent temperature and more stable operation.\u003c\/p\u003e\n\u003cp\u003eFor a condo owner in \u003cstrong\u003eMontreal\u003c\/strong\u003e, for example, a properly selected 9,000 BTU heat pump may be a better choice than a 12,000 or 18,000 BTU model selected simply with an excessively large safety margin.\u003c\/p\u003e\n\u003ch3\u003eSEER2 of 27.4: particularly impressive cooling efficiency\u003c\/h3\u003e\n\u003cp\u003eEfficiency is one of the strongest points of this SENVILLE AURA.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's technical data indicate:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSENVILLE AURA SENA-09HF\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated cooling capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,000 to 10,500 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated heating capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9,800 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,100 to 11,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27,4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14,5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2-4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13,9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2-5\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9,8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP indicated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,55\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR-454B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum outdoor temperature in heating mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese SEER2, EER2, and HSPF2 values appear directly in the technical table on page 4 of Senville's documentation. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2 of 27.4\u003c\/strong\u003e is particularly relevant for a wall-mounted heat pump used regularly during the summer. It measures seasonal cooling efficiency: the higher the value, the less electricity the unit should normally consume to produce a given amount of cooling, all other things being equal.\u003c\/p\u003e\n\u003cp\u003eSenville states in its documentation that savings of up to 58% on energy costs are possible. However, this type of data should be interpreted as a marketing comparison that depends heavily on the system being replaced, the building, the requested temperature, and usage habits. We prefer to focus on certified ratings such as \u003cstrong\u003eSEER2, EER2, and HSPF2\u003c\/strong\u003e, which allow for a much more useful comparison between equipment.\u003c\/p\u003e\n\u003ch3\u003eHeating at -30 °C: you need to look at the available capacity, not just the minimum temperature\u003c\/h3\u003e\n\u003cp\u003eA common mistake when shopping for a \u003cstrong\u003ecold-climate heat pump in Quebec\u003c\/strong\u003e is to consider only the minimum operating temperature.\u003c\/p\u003e\n\u003cp\u003eThe SENVILLE AURA SENA-09HF can operate in heating mode down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, which is also confirmed by the table on page 5 of the brochure. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, this does not mean that it provides 9,800 or 11,000 BTU\/h at -30 °C.\u003c\/p\u003e\n\u003cp\u003eThe technical data currently displayed on the AirGreen product page notably indicate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e12,000 BTU\/h at -8 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e11,500 BTU\/h at -15 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eup to \u003cstrong\u003e5,100 BTU\/h at -30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvertised COP of \u003cstrong\u003e2.494 at -8 °C\u003c\/strong\u003e, \u003cstrong\u003e1.84 at -15 °C\u003c\/strong\u003e, and \u003cstrong\u003e1.114 at -30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is precisely the type of information we analyze when a customer wants to use a heat pump as a significant source of heating in winter.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e, the available capacity remains significantly higher than at -30 °C. During extremely cold temperatures, the building's heating load increases while the heat pump's available capacity decreases. In many buildings in Greater Montreal, an additional heating source therefore remains relevant.\u003c\/p\u003e\n\u003cp\u003eThe right goal is not simply to buy a heat pump labeled “-30 °C.” You must check whether its \u003cstrong\u003eactual capacity at winter temperatures\u003c\/strong\u003e meets the needs of the room.\u003c\/p\u003e\n\u003ch3\u003eVery quiet at low speed: a real advantage for a bedroom or office\u003c\/h3\u003e\n\u003cp\u003eThe SENA-09HF has four indicated airflow levels of \u003cstrong\u003e425, 340, 260, and 200 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe indoor unit's sound pressure ranges from \u003cstrong\u003e23 dB(A)\u003c\/strong\u003e at low speed to \u003cstrong\u003e45 dB(A)\u003c\/strong\u003e in Turbo mode. The outdoor unit's stated sound level is \u003cstrong\u003e56 dB(A)\u003c\/strong\u003e. These values and the dimensions of both units are specified in the table on page 5 of the brochure. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum level of \u003cstrong\u003e23 dB(A)\u003c\/strong\u003e explains why this capacity may be particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea bedroom;\u003c\/li\u003e\n\u003cli\u003ea home office;\u003c\/li\u003e\n\u003cli\u003ea small living room;\u003c\/li\u003e\n\u003cli\u003ea rental unit;\u003c\/li\u003e\n\u003cli\u003ea condo;\u003c\/li\u003e\n\u003cli\u003ea finished basement;\u003c\/li\u003e\n\u003cli\u003ean area where you want to limit variations in fan noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AirGreen product page also indicates \u003cstrong\u003eautomatic vertical and horizontal louver control\u003c\/strong\u003e. In a small room, this detail is more important than it may seem: the direction of the airflow directly affects the feeling of comfort and the ability to distribute air without creating an overly cold area in front of the unit.\u003c\/p\u003e\n\u003ch3\u003eDimensions: a relatively compact indoor unit\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures approximately \u003cstrong\u003e33.40 in wide × 9.18 in deep × 11.76 in high\u003c\/strong\u003e and weighs approximately 22 lb.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit measures approximately \u003cstrong\u003e28.74 × 11.02 × 19.49 in\u003c\/strong\u003e and weighs approximately 66 lb.\u003c\/p\u003e\n\u003cp\u003eThese dimensions often make it possible to find a suitable location in installations where wall space is limited. However, we must still maintain the necessary clearances around the unit, account for the panel opening required for servicing, and avoid positioning the air outlet directly toward a bed, workstation, or area where the airflow could become uncomfortable.\u003c\/p\u003e\n\u003ch3\u003eWiFi, app, and Alexa compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiFi is included\u003c\/strong\u003e in the configuration shown on the AirGreen product page. Senville documentation also mentions Alexa integration, allowing you to control the heat pump remotely, adjust the settings, and schedule operating times. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe kit contents indicated in the brochure include, among other things, the wireless remote control and an Alexa USB module. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a heat pump installed in an office, a rental unit, or an intermittently occupied residence, remote control can become much more than a simple accessory. In particular, it allows the setpoint to be lowered or restored before occupants arrive and prevents the room from being unnecessarily left at too low or too high a temperature.\u003c\/p\u003e\n\u003ch3\u003eThe switch to R-454B\u003c\/h3\u003e\n\u003cp\u003eThis new generation of SENVILLE AURA uses \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies a charge of \u003cstrong\u003e37.15 oz\u003c\/strong\u003e and a factory charge corresponding to a maximum piping length of \u003cstrong\u003e25 feet\u003c\/strong\u003e. For an installation with a 50-foot line, the brochure explicitly states that refrigerant must be added on site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOn the AirGreen product sheet, the specified piping diameter for this combination is \u003cstrong\u003e1\/4 in – 3\/8 in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eR-454B belongs to the new generation of refrigerants with reduced global warming potential compared with R-410A. Since it is an A2L-class refrigerant, its installation requires appropriate work methods, tools, and procedures. This is an additional reason to entrust commissioning to HVAC professionals rather than treating the unit as a do-it-yourself product.\u003c\/p\u003e\n\u003ch2\u003eWhat we check at AirGreen before installing a SENVILLE AURA 9,000 BTU\u003c\/h2\u003e\n\u003cp\u003eA good heat pump can deliver disappointing results when it is improperly sized or poorly positioned. At AirGreen, much of our work therefore involves looking at what surrounds the equipment, not just the figures listed on its technical specifications sheet.\u003c\/p\u003e\n\u003ch3\u003eA typical scenario: a small room with a significant heat load\u003c\/h3\u003e\n\u003cp\u003eWe regularly encounter rooms in \u003cstrong\u003eGreater Montreal\u003c\/strong\u003e whose size seems to immediately indicate a 9,000 BTU heat pump, when the reality is more complex.\u003c\/p\u003e\n\u003cp\u003eConsider a 350 sq. ft. office on the top floor of a plex in Montreal. If it has large west-facing windows, a poorly insulated ceiling, and receives several hours of sunlight, its cooling load may be very different from that of a basement of the same size in \u003cstrong\u003eLongueuil\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eConversely, automatically installing a 12,000 or 18,000 BTU unit “just to be sure” is not necessarily better.\u003c\/p\u003e\n\u003cp\u003eThat is why we examine factors such as the building envelope, windows, solar exposure, room layout, existing heating system, and natural air circulation before recommending the capacity.\u003c\/p\u003e\n\u003ch3\u003eRefrigeration installation: the details that determine the quality of the result\u003c\/h3\u003e\n\u003cp\u003eSenville’s documentation specifies that \u003cstrong\u003eprofessional installation is required to maintain warranty coverage\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor us, this means properly carrying out the piping run, drainage, wall-penetration sealing, refrigerant-circuit evacuation, leak-tightness tests, and commissioning.\u003c\/p\u003e\n\u003cp\u003eThe drain route is particularly important. An indoor unit can cool a room perfectly while causing problems if the condensate does not drain properly. Insufficient slope, an improperly positioned drain, or an installation that unnecessarily requires adding a condensate pump can increase noise and future maintenance.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit’s location also matters. On the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, in Laval, or in Montreal, we must plan for snow accumulation, drainage during defrost cycles, and future access for servicing.\u003c\/p\u003e\n\u003ch3\u003eElectrical supply: 208\/230 V, MCA 10 A, and maximum protection of 15 A\u003c\/h3\u003e\n\u003cp\u003eThe brochure specifies a \u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e power supply, a minimum circuit ampacity of \u003cstrong\u003e10 A\u003c\/strong\u003e, and a maximum fuse of \u003cstrong\u003e15 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt also specifies connection wiring \u003cstrong\u003e14\/4 AWG\u003c\/strong\u003e between the components. This indication should not automatically be confused with the complete sizing of the electrical circuit supplying the equipment. The final wiring, circuit breaker, disconnect switch, and electrical compliance must always be determined according to the actual installation and applicable requirements.\u003c\/p\u003e\n\u003cp\u003eFor homeowners, the practical advantage of a wall-mounted heat pump with this capacity is that its electrical demand remains relatively modest compared with many higher-capacity systems.\u003c\/p\u003e\n\u003ch3\u003eA heat pump particularly suited to which applications?\u003c\/h3\u003e\n\u003cp\u003eThe SENVILLE AURA 9,000 BTU is particularly appealing when the area to be treated is relatively small and well defined.\u003c\/p\u003e\n\u003cp\u003eWe would consider it especially for a primary bedroom, office, small living area, studio, compact condo, or a room that remains too hot or too cold despite the main system.\u003c\/p\u003e\n\u003cp\u003eWe would be more cautious when a homeowner wants to heat several separate rooms with a single 9,000 BTU indoor unit. Even when a heat pump has sufficient theoretical capacity, air must be able to circulate physically from one room to another. A closed door or a long corridor can completely change the outcome.\u003c\/p\u003e\n\u003ch3\u003eWarranty: a difference to be confirmed between the AirGreen product page and the Senville brochure\u003c\/h3\u003e\n\u003cp\u003eThere is currently a significant difference between the two sources provided.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product page states a warranty of \u003cstrong\u003e10 years on the compressor, 10 years on parts, and 0 years on labor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Senville brochure provided states \u003cstrong\u003e10 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis difference must be confirmed when requesting a quote or making the purchase, because warranty conditions may depend on the applicable program, the distribution channel, product registration, or the commercial terms in effect. We prefer to clarify this information before installation rather than leave a homeowner to assume that coverage applies automatically.\u003c\/p\u003e\n\u003ch3\u003eWhat about the LogisVert subsidy?\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen page provided with this product currently lists a \u003cstrong\u003e$0 provincial subsidy\u003c\/strong\u003e, with an update dated November 26, 2025.\u003c\/p\u003e\n\u003cp\u003eBecause financial assistance programs may change, we always recommend verifying eligibility when preparing the quote. A heat pump certified as ENERGY STAR or suitable for cold climates is not automatically eligible for all subsidies available in Quebec.\u003c\/p\u003e\n\u003ch3\u003eWhy have this SENVILLE AURA installed by AirGreen?\u003c\/h3\u003e\n\u003cp\u003eOur role is not limited to mounting two units on the wall and connecting the refrigerant lines.\u003c\/p\u003e\n\u003cp\u003eFor an \u003cstrong\u003eHVAC installation in Montreal, Laval, Longueuil, on the North Shore, or on the South Shore\u003c\/strong\u003e, we want the capacity to truly match the room, the indoor unit to be installed in a logical location, the outdoor unit to remain accessible, and the drainage to function properly throughout the cooling season.\u003c\/p\u003e\n\u003cp\u003eWith a model like the \u003cstrong\u003eSENVILLE AURA R454B 9,000 BTU\u003c\/strong\u003e, the technical specifications are already impressive: \u003cstrong\u003e27.4 SEER2\u003c\/strong\u003e, heating operation down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, low indoor noise levels, WiFi, inverter modulation, and R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eThe difference between a satisfactory installation and a truly successful one ultimately comes down to sizing, configuration, and the execution of the work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre you thinking of installing a SENVILLE AURA 9,000 BTU in your home, condo, office, or apartment? Contact AirGreen for a quote and to verify whether this capacity is truly suitable for your space. We serve Montreal, Laval, Longueuil, the South Shore, and the North Shore for the sale, installation, and service of wall-mounted heat pumps.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119541661988,"sku":"SENA-09HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_AURA_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_cf54df66-8012-4f24-97a2-77d706feab9d.png?v=1789049511","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-senville-aura-r454b-9000-btu-montreal-rive-sud-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}