{"product_id":"thermopompe-murale-sharp-filtersweep-12000-btu-r32","title":"SHARP FilterSweep Wall-Mounted Heat Pump | 12000 BTU | -30°C R32","description":"\u003ch2 data-start=\"120\" data-end=\"214\"\u003e A wall-mounted heat pump designed for Quebec's climate and the realities of homes in Montreal\u003c\/h2\u003e\n\n \u003cp data-start=\"216\" data-end=\"716\"\u003eThe \u003cstrong data-start=\"219\" data-end=\"283\"\u003eSHARP FilterSweep Wall-Mounted Heat Pump | 12000 BTU | -30°C R32\u003c\/strong\u003e represents a significant advancement in residential \u003cstrong data-start=\"338\" data-end=\"362\"\u003ewall-mounted heat pumps\u003c\/strong\u003e . At \u003cstrong data-start=\"384\" data-end=\"396\"\u003eAirGreen\u003c\/strong\u003e , we have been installing \u003cstrong data-start=\"427\" data-end=\"435\"\u003eHVAC\u003c\/strong\u003e systems in \u003cstrong data-start=\"438\" data-end=\"450\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"452\" data-end=\"461\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"463\" data-end=\"476\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"485\" data-end=\"498\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"505\" data-end=\"517\"\u003eSouth Shores\u003c\/strong\u003e for years, and this model directly addresses the challenges we observe in the field: neglected filter maintenance, loss of energy efficiency, and inadequate winter performance.\u003c\/p\u003e\n\n \u003cp data-start=\"718\" data-end=\"1024\"\u003eWith a heating capacity down to \u003cstrong data-start=\"757\" data-end=\"766\"\u003e-30°C\u003c\/strong\u003e , \u003cstrong data-start=\"783\" data-end=\"791\"\u003eR-32\u003c\/strong\u003e refrigerant, \u003cstrong data-start=\"810\" data-end=\"839\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e certification, and an exclusive \u003cstrong data-start=\"864\" data-end=\"895\"\u003eAuto Filter Sweeping System\u003c\/strong\u003e , this unit is designed for Quebec winters and for owners who are looking for long-term reliability and stability.\u003c\/p\u003e\n\n\u003chr data-start=\"1026\" data-end=\"1029\"\u003e\n\n\u003ch2 data-start=\"1031\" data-end=\"1112\"\u003e The Auto Filter Sweeping system: a concrete solution to a common problem\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1114\" data-end=\"1170\"\u003e Why filter maintenance is often neglected\u003c\/h3\u003e\n\n\u003cp data-start=\"1172\" data-end=\"1331\"\u003e During our service calls in \u003cstrong data-start=\"1201\" data-end=\"1213\"\u003eMontreal\u003c\/strong\u003e and the \u003cstrong data-start=\"1220\" data-end=\"1234\"\u003eMontérégie region\u003c\/strong\u003e , we frequently find that the filters in mini-split air conditioners are clogged. A clogged filter: \u003c\/p\u003e\n\n\u003cul data-start=\"1333\" data-end=\"1477\"\u003e\n\n\u003cli data-start=\"1333\" data-end=\"1356\"\u003e\n\n\u003cp data-start=\"1335\" data-end=\"1356\"\u003e Reduces airflow \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1357\" data-end=\"1402\"\u003e\n\n\u003cp data-start=\"1359\" data-end=\"1402\"\u003e It forces the compressor to work harder \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1403\" data-end=\"1440\"\u003e\n\n\u003cp data-start=\"1405\" data-end=\"1440\"\u003e Increases electricity consumption\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1441\" data-end=\"1477\"\u003e\n\n \u003cp data-start=\"1443\" data-end=\"1477\"\u003eReduces the lifespan of the system\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1479\" data-end=\"1619\"\u003e In a duplex in \u003cstrong data-start=\"1496\" data-end=\"1509\"\u003eLongueuil\u003c\/strong\u003e , we recently measured a performance loss of nearly 18% simply due to a lack of maintenance.\u003c\/p\u003e\n\n\u003ch3 data-start=\"1621\" data-end=\"1658\"\u003e How does FilterSweep work?\u003c\/h3\u003e\n\n\u003cp data-start=\"1660\" data-end=\"1765\"\u003e The \u003cstrong data-start=\"1663\" data-end=\"1694\"\u003eSHARP FilterSweep 12000 BTU\u003c\/strong\u003e incorporates an automatic filter sweeping system. Specifically: \u003c\/p\u003e\n\n\u003cul data-start=\"1767\" data-end=\"2009\"\u003e\n\n\u003cli data-start=\"1767\" data-end=\"1864\"\u003e\n\n\u003cp data-start=\"1769\" data-end=\"1864\"\u003e An internal mechanism automatically sweeps the filters every 24 hours of operation. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1865\" data-end=\"1914\"\u003e\n\n\u003cp data-start=\"1867\" data-end=\"1914\"\u003e The dust is collected in an integrated bin. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1915\" data-end=\"1955\"\u003e\n\n\u003cp data-start=\"1917\" data-end=\"1955\"\u003e The filter stays clean longer. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1956\" data-end=\"2009\"\u003e\n\n\u003cp data-start=\"1958\" data-end=\"2009\"\u003e The unit maintains its optimal seasonal performance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"2011\" data-end=\"2155\"\u003e According to the manufacturer's data, the system can accumulate dust equivalent to approximately one year of normal use before emptying the bin.\u003c\/p\u003e\n\n \u003cp data-start=\"2157\" data-end=\"2333\"\u003eFor condo owners in \u003cstrong data-start=\"2192\" data-end=\"2201\"\u003eLaval\u003c\/strong\u003e or rental unit owners on the \u003cstrong data-start=\"2231\" data-end=\"2243\"\u003eSouth Shore\u003c\/strong\u003e , this means less manual maintenance, fewer oversights, and more consistent efficiency.\u003c\/p\u003e\n\n\u003chr data-start=\"2335\" data-end=\"2338\"\u003e\n\n\u003ch2 data-start=\"2340\" data-end=\"2397\"\u003e Actual winter performance: heating down to -30°C\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2399\" data-end=\"2424\"\u003e Capacity and power\u003c\/h3\u003e\n\n\u003cp data-start=\"2426\" data-end=\"2443\"\u003e This model offers: \u003c\/p\u003e\n\n\u003cul data-start=\"2445\" data-end=\"2627\"\u003e\n\n\u003cli data-start=\"2445\" data-end=\"2491\"\u003e\n\n\u003cp data-start=\"2447\" data-end=\"2491\"\u003e \u003cstrong data-start=\"2447\" data-end=\"2491\"\u003eCooling capacity: 12,000 BTU\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2492\" data-end=\"2548\"\u003e\n\n\u003cp data-start=\"2494\" data-end=\"2548\"\u003e \u003cstrong data-start=\"2494\" data-end=\"2548\"\u003eMaximum heating capacity at -8°C: 19,000 BTU\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2549\" data-end=\"2584\"\u003e\n\n\u003cp data-start=\"2551\" data-end=\"2584\"\u003e \u003cstrong data-start=\"2551\" data-end=\"2584\"\u003eCapacity at -15°C: 15,500 BTU\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2585\" data-end=\"2627\"\u003e\n\n\u003cp data-start=\"2587\" data-end=\"2627\"\u003e Guaranteed operation down to \u003cstrong data-start=\"2618\" data-end=\"2627\"\u003e-30°C\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"2629\" data-end=\"2864\"\u003eIn a bungalow in \u003cstrong data-start=\"2648\" data-end=\"2674\"\u003eRepentigny (North Shore)\u003c\/strong\u003e , we replaced an old R-410A system with this R-32 unit. Result: a noticeable reduction in defrost cycles and improved thermal stability in the 550 sq ft main living room.\u003c\/p\u003e\n\n\u003ch3 data-start=\"2866\" data-end=\"2890\"\u003e Hot Gas Pipe System\u003c\/h3\u003e\n\n\u003cp data-start=\"2892\" data-end=\"3138\"\u003e The outdoor unit is equipped with a patented thermal management system that uses residual heat to prevent the compressor from freezing. Unlike standard systems that rely solely on electrical resistance, this approach: \u003c\/p\u003e\n\n\u003cul data-start=\"3140\" data-end=\"3258\"\u003e\n\n\u003cli data-start=\"3140\" data-end=\"3176\"\u003e\n\n\u003cp data-start=\"3142\" data-end=\"3176\"\u003e Reduces energy consumption \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3177\" data-end=\"3208\"\u003e\n\n\u003cp data-start=\"3179\" data-end=\"3208\"\u003e Reduces defrosting time \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3209\" data-end=\"3258\"\u003e\n\n\u003cp data-start=\"3211\" data-end=\"3258\"\u003e Maintains performance in extreme conditions \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"3260\" data-end=\"3263\"\u003e\n\n\u003ch2 data-start=\"3265\" data-end=\"3310\"\u003e Energy efficiency and R-32 refrigerant\u003c\/h2\u003e\n\n\u003cp data-start=\"3312\" data-end=\"3394\"\u003e The transition to \u003cstrong data-start=\"3334\" data-end=\"3342\"\u003eR-32\u003c\/strong\u003e is a significant environmental benefit. This gas: \u003c\/p\u003e\n\n\u003cul data-start=\"3396\" data-end=\"3560\"\u003e\n\n\u003cli data-start=\"3396\" data-end=\"3463\"\u003e\n\n\u003cp data-start=\"3398\" data-end=\"3463\"\u003e It has a lower global warming potential than R-410A. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3464\" data-end=\"3503\"\u003e\n\n\u003cp data-start=\"3466\" data-end=\"3503\"\u003e Improves thermodynamic efficiency\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3504\" data-end=\"3560\"\u003e\n\n \u003cp data-start=\"3506\" data-end=\"3560\"\u003eEnables superior performance at partial load\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3562\" data-end=\"3741\"\u003e With its high seasonal indices (SEER2, HSPF2), this heat pump is eligible for provincial subsidy programs such as \u003cstrong data-start=\"3694\" data-end=\"3707\"\u003eLogisVert\u003c\/strong\u003e (subject to updated criteria).\u003c\/p\u003e\n\n\u003cp data-start=\"3743\" data-end=\"3945\"\u003e At \u003cstrong data-start=\"3748\" data-end=\"3760\"\u003eAirGreen\u003c\/strong\u003e , we always analyze eligibility for subsidies before installation in order to optimize the return on investment for our clients in \u003cstrong data-start=\"3904\" data-end=\"3916\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"3918\" data-end=\"3927\"\u003eLaval\u003c\/strong\u003e and \u003cstrong data-start=\"3931\" data-end=\"3944\"\u003eLongueuil\u003c\/strong\u003e .\u003c\/p\u003e\n\n\u003chr data-start=\"3947\" data-end=\"3950\"\u003e\n\n\u003ch2 data-start=\"3952\" data-end=\"4016\"\u003e Smart comfort: Coanda Airflow, Multi Space and Spot Air\u003c\/h2\u003e\n\n\u003ch3 data-start=\"4018\" data-end=\"4061\"\u003e Coanda Airflow: Controlled Distribution\u003c\/h3\u003e\n\n \u003cp data-start=\"4063\" data-end=\"4287\"\u003e\u003cstrong data-start=\"4078\" data-end=\"4096\"\u003eCoanda Airflow\u003c\/strong\u003e technology allows air to be projected up to approximately 50 feet. In cooling mode, the air is directed towards the ceiling to avoid direct drafts. In heating mode, the air is directed towards the floor.\u003c\/p\u003e\n\n\u003cp data-start=\"4289\" data-end=\"4442\"\u003e In a triplex in \u003cstrong data-start=\"4307\" data-end=\"4319\"\u003eAhuntsic\u003c\/strong\u003e , this feature allowed for better thermal uniformity in an open area combining living room and dining room.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4444\" data-end=\"4459\"\u003e Multi Space\u003c\/h3\u003e\n\n\u003cp data-start=\"4461\" data-end=\"4574\"\u003e A single unit can distribute air to adjacent spaces when the layout allows. Ideal for: \u003c\/p\u003e\n\n\u003cul data-start=\"4576\" data-end=\"4634\"\u003e\n\n\u003cli data-start=\"4576\" data-end=\"4592\"\u003e\n\n\u003cp data-start=\"4578\" data-end=\"4592\"\u003e Open areas \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4593\" data-end=\"4600\"\u003e\n\n\u003cp data-start=\"4595\" data-end=\"4600\"\u003e Lofts \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4601\" data-end=\"4634\"\u003e\n\n\u003cp data-start=\"4603\" data-end=\"4634\"\u003e Houses with connected hallways\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-start=\"4636\" data-end=\"4648\"\u003e Spot Air\u003c\/h3\u003e\n\n\u003cp data-start=\"4650\" data-end=\"4815\"\u003e This feature allows you to target a specific area in the room via the remote control or mobile app. Ideal for a home office or reading nook.\u003c\/p\u003e\n\n\u003chr data-start=\"4817\" data-end=\"4820\"\u003e\n\n\u003ch2 data-start=\"4822\" data-end=\"4854\"\u003e Detailed technical data \u003c\/h2\u003e\n\n\u003cul data-start=\"4856\" data-end=\"5174\"\u003e\n\n\u003cli data-start=\"4856\" data-end=\"4891\"\u003e\n\n\u003cp data-start=\"4858\" data-end=\"4891\"\u003e \u003cstrong data-start=\"4858\" data-end=\"4891\"\u003eInterior model: AY-XP12DWU\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4892\" data-end=\"4926\"\u003e\n\n \u003cp data-start=\"4894\" data-end=\"4926\"\u003e\u003cstrong data-start=\"4894\" data-end=\"4926\"\u003eExterior model: AE-X12DWU\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4927\" data-end=\"4943\"\u003e\n\n\u003cp data-start=\"4929\" data-end=\"4943\"\u003e Voltage: 220V \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4944\" data-end=\"4971\"\u003e\n\n\u003cp data-start=\"4946\" data-end=\"4971\"\u003e Piping: 1\/4 – 3\/8 in \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4972\" data-end=\"5013\"\u003e\n\n\u003cp data-start=\"4974\" data-end=\"5013\"\u003e Indoor noise level: 23 to 44 dB(A) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5014\" data-end=\"5050\"\u003e\n\n\u003cp data-start=\"5016\" data-end=\"5050\"\u003e Outdoor noise level: 50 dB(A) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5051\" data-end=\"5101\"\u003e\n\n\u003cp data-start=\"5053\" data-end=\"5101\"\u003e Interior dimensions: 31.41 x 11.84 x 9.81 in \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5102\" data-end=\"5174\"\u003e\n\n\u003cp data-start=\"5104\" data-end=\"5174\"\u003e Warranty: 10 years compressor, 10 years parts, labor optional\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5176\" data-end=\"5344\"\u003e These features make it an excellent choice for condominiums in \u003cstrong data-start=\"5248\" data-end=\"5260\"\u003eMontreal\u003c\/strong\u003e , single-family homes in \u003cstrong data-start=\"5290\" data-end=\"5299\"\u003eLaval\u003c\/strong\u003e , or rental properties in \u003cstrong data-start=\"5329\" data-end=\"5343\"\u003eMontérégie\u003c\/strong\u003e .\u003c\/p\u003e\n\n\u003chr data-start=\"5346\" data-end=\"5349\"\u003e\n\n\u003ch2 data-start=\"5351\" data-end=\"5412\"\u003e Professional HVAC installation: a determining factor\u003c\/h2\u003e\n\n\u003cp data-start=\"5414\" data-end=\"5540\"\u003e Even the best \u003cstrong data-start=\"5432\" data-end=\"5454\"\u003ewall-mounted heat pump\u003c\/strong\u003e can lose efficiency if the installation is inadequate. At \u003cstrong data-start=\"5520\" data-end=\"5532\"\u003eAirGreen\u003c\/strong\u003e , we: \u003c\/p\u003e\n\n\u003cul data-start=\"5542\" data-end=\"5752\"\u003e\n\n\u003cli data-start=\"5542\" data-end=\"5590\"\u003e\n\n\u003cp data-start=\"5544\" data-end=\"5590\"\u003e Let's size according to the actual thermal load \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5591\" data-end=\"5623\"\u003e\n\n\u003cp data-start=\"5593\" data-end=\"5623\"\u003e Let's check the amperage (MOP 25A)\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5624\" data-end=\"5662\"\u003e\n\n \u003cp data-start=\"5626\" data-end=\"5662\"\u003eLet's optimize the pipe length \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5663\" data-end=\"5712\"\u003e\n\n\u003cp data-start=\"5665\" data-end=\"5712\"\u003e Let's ensure proper condensate drainage \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5713\" data-end=\"5752\"\u003e\n\n\u003cp data-start=\"5715\" data-end=\"5752\"\u003e We strictly adhere to RBQ standards\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5754\" data-end=\"6018\"\u003e We recently corrected an installation in \u003cstrong data-start=\"5844\" data-end=\"5860\"\u003eBoucherville\u003c\/strong\u003e that was carried out without a thermal load calculation: oversizing, short cycles, and discomfort. After recalibration and replacement with the FilterSweep 12000 BTU model, thermal stability was restored.\u003c\/p\u003e\n\n\u003chr data-start=\"6020\" data-end=\"6023\"\u003e\n\n\u003ch2 data-start=\"6025\" data-end=\"6063\"\u003e Who is this heat pump intended for? \u003c\/h2\u003e\n\n\u003cul data-start=\"6065\" data-end=\"6268\"\u003e\n\n\u003cli data-start=\"6065\" data-end=\"6107\"\u003e\n\n\u003cp data-start=\"6067\" data-end=\"6107\"\u003e Owners of condos ranging from 400 to 700 sq ft \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6108\" data-end=\"6152\"\u003e\n\n\u003cp data-start=\"6110\" data-end=\"6152\"\u003e Main living rooms of single-family homes \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6153\" data-end=\"6215\"\u003e\n\n\u003cp data-start=\"6155\" data-end=\"6215\"\u003e Rental properties seeking reliability and low maintenance \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6216\" data-end=\"6268\"\u003e\n\n\u003cp data-start=\"6218\" data-end=\"6268\"\u003e Energy-conscious homeowners\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6270\" data-end=\"6424\"\u003e It is particularly suited to the climate of \u003cstrong data-start=\"6317\" data-end=\"6335\"\u003eGreater Montreal\u003c\/strong\u003e , including the \u003cstrong data-start=\"6349\" data-end=\"6362\"\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"6369\" data-end=\"6381\"\u003eSouth Shore\u003c\/strong\u003e , thanks to its extreme heating capacity.\u003c\/p\u003e\n\n\u003chr data-start=\"6426\" data-end=\"6429\"\u003e\n\n \u003ch2 data-start=\"6431\" data-end=\"6490\"\u003eWhy choose AirGreen for your SHARP heat pump? \u003c\/h2\u003e\n\n\u003cul data-start=\"6492\" data-end=\"6683\"\u003e\n\n\u003cli data-start=\"6492\" data-end=\"6526\"\u003e\n\n\u003cp data-start=\"6494\" data-end=\"6526\"\u003e Experienced refrigeration technicians \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6527\" data-end=\"6572\"\u003e\n\n\u003cp data-start=\"6529\" data-end=\"6572\"\u003e $5,000,000 liability insurance \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6573\" data-end=\"6613\"\u003e\n\n\u003cp data-start=\"6575\" data-end=\"6613\"\u003e Final clear submission before work begins \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6614\" data-end=\"6651\"\u003e\n\n\u003cp data-start=\"6616\" data-end=\"6651\"\u003e Analysis of available subsidies \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6652\" data-end=\"6683\"\u003e\n\n\u003cp data-start=\"6654\" data-end=\"6683\"\u003e Structured after-sales service\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6685\" data-end=\"6774\"\u003e We don't just install: we ensure long-term performance.\u003c\/p\u003e\n\n\u003chr data-start=\"6776\" data-end=\"6779\"\u003e\n\n\u003ch2 data-start=\"6781\" data-end=\"6833\"\u003e Upgrade to a sustainable and efficient HVAC solution\u003c\/h2\u003e\n\n\u003cp data-start=\"6835\" data-end=\"7171\"\u003e The \u003cstrong data-start=\"6838\" data-end=\"6902\"\u003eSHARP FilterSweep Wall-Mounted Heat Pump | 12,000 BTU | -30°C R32\u003c\/strong\u003e combines winter performance, automatic filter management, and advanced energy efficiency. For \u003cstrong data-start=\"7010\" data-end=\"7083\"\u003eHVAC installation in Montreal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/strong\u003e , contact \u003cstrong data-start=\"7095\" data-end=\"7107\"\u003eAirGreen\u003c\/strong\u003e today for a detailed and personalized quote.\u003c\/p\u003e","brand":"Sharp","offers":[{"title":"Default Title","offer_id":52036261675300,"sku":"AE-X12DWU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERPOMPESHARPFILTERSWEEP12000BTU.png?v=1772452960","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-sharp-filtersweep-12000-btu-r32","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}