{"product_id":"thermopompe-murale-york-serie-p-18-seer-12000-btu-115v","title":"YORK P Series Wall-Mounted Heat Pump 18 SEER | 12000 BTU 115V","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA compact 115 V wall-mounted heat pump for projects where the electrical supply matters as much as comfort\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK P Series 12,000 BTU 115 V wall-mounted heat pump\u003c\/strong\u003e holds a distinctive place among ductless systems. Its rated capacity of \u003cstrong\u003e12,000 BTU\/h in cooling\u003c\/strong\u003e, operation on \u003cstrong\u003e115 V\u003c\/strong\u003e, Inverter technology compressor, and heating capacity down to \u003cstrong\u003e-20 °C\u003c\/strong\u003e make it an option worth considering for certain apartments, condominiums, older homes, offices, or additions where a 208\/230 V installation is not necessarily the most practical solution.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, when we assess a wall-mounted heat pump installation in \u003cstrong\u003eMontreal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/strong\u003e, we never look only at the number of BTUs. The available voltage, electrical panel capacity, room layout, refrigerant line length, possible outdoor unit location, and the homeowner’s expectations for winter heating directly influence the choice.\u003c\/p\u003e\n\u003cp\u003eThe pair that interests us here is very specific:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: DHP12CSB11S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: DHP12NWB11S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated cooling capacity: 12,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated heating capacity: 13,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 115 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-410A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant piping: 1\/4 in. liquid and 3\/8 in. gas\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating operation: down to -20 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWi-Fi: available with adapter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI listed on our product sheet: 8578533\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe YORK brochure confirms a modulating capacity for this combination of \u003cstrong\u003e3,753 to 12,500 BTU\/h in cooling\u003c\/strong\u003e and \u003cstrong\u003e3,412 to 15,013 BTU\/h in heating\u003c\/strong\u003e, with an EER of 10.55, a SEER of 16, and an HSPF of 9. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAn important clarification about the name “P Series 18 SEER”\u003c\/h3\u003e\n\u003cp\u003eThe commercial name of this product line can easily cause confusion. YORK presents the family as the \u003cstrong\u003eP Series up to 18 SEER\u003c\/strong\u003e, but the 2020 technical documentation indicates that the \u003cstrong\u003eDHP12NWB11S \/ DHP12CSB11S 12,000 BTU, 115 V pair has a SEER of 16\u003c\/strong\u003e, not 18.\u003c\/p\u003e\n\u003cp\u003eThis is a distinction we consider important at AirGreen. The maximum efficiency advertised for an entire series is not always the efficiency of each of its capacities and electrical configurations.\u003c\/p\u003e\n\u003cp\u003eIt is also important to avoid directly comparing this \u003cstrong\u003eSEER\u003c\/strong\u003e with the \u003cstrong\u003eSEER2\u003c\/strong\u003e of newer heat pumps. The YORK brochure used for this P Series applies the older SEER, EER, and HSPF metrics. When a property owner compares this unit with a current-generation R-32 or R-454B heat pump, we compare the technical specifications according to their respective evaluation methods rather than simply placing two figures side by side.\u003c\/p\u003e\n\u003ch3\u003eWhy 115 V can be beneficial in a renovation project\u003c\/h3\u003e\n\u003cp\u003eOne of the main distinguishing features of the \u003cstrong\u003eDHP12CSB11S\u003c\/strong\u003e model is its \u003cstrong\u003e115 V\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\u003cp\u003eIn many older Montreal buildings, duplexes, triplexes, certain condos, or commercial spaces developed in stages, electrical constraints can play a significant role. A 115 V unit can sometimes simplify the electrical design compared with a heat pump requiring a 208\/230 V power supply.\u003c\/p\u003e\n\u003cp\u003eHowever, this does not mean that the unit should be connected to a standard residential outlet.\u003c\/p\u003e\n\u003cp\u003eFor the 12,000 BTU model, YORK specifies:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRated cooling current: 12.4 A\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eRated heating current: 13.5 A\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eMCA: 20 A\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eMOCP: 30 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe electrical installation must therefore be planned correctly. At AirGreen, we check the panel configuration, electrical routing, and equipment requirements before considering whether a 115 V system actually represents an advantage for the building.\u003c\/p\u003e\n\u003ch3\u003eA more useful modulating capacity than a simple 12,000 BTU figure\u003c\/h3\u003e\n\u003cp\u003eAn Inverter heat pump does not operate continuously at its maximum capacity. It adjusts the compressor output to the room’s actual demand.\u003c\/p\u003e\n\u003cp\u003eFor this YORK P Series, the stated cooling range is \u003cstrong\u003e3,753 to 12,500 BTU\/h\u003c\/strong\u003e. In heating mode, modulation ranges from \u003cstrong\u003e3,412 to 15,013 BTU\/h\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis range is important in a primary bedroom, living room, open-concept apartment, or office whose needs vary significantly depending on the time of day. As the temperature approaches the setpoint, the unit can reduce its capacity rather than operate only in on-off cycles.\u003c\/p\u003e\n\u003cp\u003eIn the field, this is precisely what we look for when properly sizing a system: a machine capable of operating for long periods at partial load instead of an oversized unit that reaches the target temperature quickly, shuts off, and then restarts frequently.\u003c\/p\u003e\n\u003cp\u003eAn oversized heat pump is not automatically more comfortable. It can lead to shorter cycles, less consistent humidity management, and more noticeable temperature fluctuations.\u003c\/p\u003e\n\u003ch3\u003eHeating down to -20°C: useful, but it is important to understand what this means\u003c\/h3\u003e\n\u003cp\u003eThe 12,000 BTU P Series is specified to operate in heating mode between \u003cstrong\u003e-20 °C and 24 °C outdoors\u003c\/strong\u003e. Its outdoor cooling range extends from \u003cstrong\u003e-18 °C to 46 °C\u003c\/strong\u003e. YORK also confirms the use of \u003cstrong\u003eR-410A\u003c\/strong\u003e for this generation of equipment. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, operation permitted down to -20 °C does not necessarily mean that the unit delivers its full rated capacity of 13,000 BTU at -20 °C.\u003c\/p\u003e\n\u003cp\u003eThe brochure provides a rated capacity and an operating range, but this table does not give the exact heating capacity at -8 °C, -15 °C, and -20 °C for this pair. We therefore avoid making up these values.\u003c\/p\u003e\n\u003cp\u003eFor a Greater Montreal homeowner who wants to use a heat pump as the primary heating source, this point is essential. Winter temperatures in \u003cstrong\u003eMontreal, Laval, Longueuil, the North Shore, and the South Shore\u003c\/strong\u003e can fall below -20 °C. A serious analysis must then take into account the existing backup heating system and the home's actual heating load.\u003c\/p\u003e\n\u003ch3\u003eIndoor sound level: 29 dB(A) at the lowest setting\u003c\/h3\u003e\n\u003cp\u003eAcoustic comfort is particularly important when an indoor unit is installed in a bedroom, office, or small condo.\u003c\/p\u003e\n\u003cp\u003eFor the \u003cstrong\u003eDHP12NWB11S\u003c\/strong\u003e, YORK lists four sound pressure levels corresponding to the different fan speeds:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e43 \/ 39 \/ 35 \/ 29 dB(A).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe airflow rate varies accordingly between:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e400 \/ 318 \/ 241 \/ 194 CFM.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese four levels give the unit some flexibility. At low demand, an airflow rate of 194 CFM and a stated sound level of 29 dB(A) are much better suited to a bedroom than continuous operation at maximum speed.\u003c\/p\u003e\n\u003cp\u003eThe official dimensions of the 12,000 BTU indoor unit are \u003cstrong\u003e33 in wide × 11 in deep × 8 in high\u003c\/strong\u003e, or approximately \u003cstrong\u003e845 × 289 × 209 mm\u003c\/strong\u003e. The documentation indicates a net weight of approximately 22 lb. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis detail deserves emphasis because some older online listings may show a width of 31 in. For the \u003cstrong\u003eDHP12NWB11S\u003c\/strong\u003e, the YORK technical table provided in the brochure clearly indicates \u003cstrong\u003e33 × 11 × 8 in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eVertical and horizontal louvers: true control over air distribution\u003c\/h3\u003e\n\u003cp\u003eThe air distribution of a wall-mounted heat pump directly affects the feeling of comfort. A unit can reach the right temperature while still creating an uncomfortable area if its airflow blows directly onto a sofa, bed, or desk.\u003c\/p\u003e\n\u003cp\u003eThe P Series feature table notably mentions:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3D Auto Swing, including vertical and horizontal oscillation\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eUp and Down Swing\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eLeft and Right Swing\u003c\/strong\u003e,\u003cbr\u003eas well as \u003cstrong\u003eFixed-Angle Swing\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis helps distribute the air over a wider area and better adapt the airflow to the room’s geometry.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, the positioning of the unit is nevertheless more important than the sophistication of the louvers. Installing a wall-mounted unit simply because a wall is available can produce a mediocre result. Instead, we look for a position that promotes natural airflow throughout the room while avoiding blowing directly on the occupants.\u003c\/p\u003e\n\u003ch3\u003eStandard Remote and Optional Wi-Fi\u003c\/h3\u003e\n\u003cp\u003eThe P Series comes with a \u003cstrong\u003eDRCPX wireless remote control\u003c\/strong\u003e. Wi-Fi is not built in directly: the documentation indicates that a \u003cstrong\u003eCS532AH adapter\u003c\/strong\u003e is required. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe mobile app can then allow certain settings to be changed from a phone or tablet. YORK documentation also mentions the EWPE Smart app for the P and X Series when the necessary adapter is installed. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a cottage, a dwelling used occasionally, or a room whose temperature must be adjusted before the occupants arrive, this option can be practical. For a homeowner who never uses remote controls, keeping the standard remote is just as reasonable.\u003c\/p\u003e\n\u003ch2\u003eInstallation in Montreal, Laval, Longueuil, on the North Shore and South Shore: the details that determine the result\u003c\/h2\u003e\n\u003ch3\u003e1\/4 in. - 3\/8 in. piping and a maximum length of 65 feet\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDHP12CSB11S\u003c\/strong\u003e uses a \u003cstrong\u003e1\/4 in.\u003c\/strong\u003e liquid line and a \u003cstrong\u003e3\/8 in.\u003c\/strong\u003e gas line.\u003c\/p\u003e\n\u003cp\u003eFor the 12,000 BTU 115 V model, YORK also indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003emaximum total piping length: 65 ft (20 m);\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003emaximum height difference: 33 ft (10 m);\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003edrain diameter: 5\/8 in.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese limits can become critical in a high-floor condo, a home where the outdoor unit must be placed far from the wall-mounted indoor unit, or a project requiring several architectural elements to be bypassed.\u003c\/p\u003e\n\u003cp\u003eIn a relatively simple installation, we always try to keep the refrigerant route as direct as possible. Each additional detour affects the amount of piping, drainage, the appearance of the line-hide covers, and sometimes the project cost.\u003c\/p\u003e\n\u003ch3\u003eDrainage deserves just as much attention as the refrigerant lines\u003c\/h3\u003e\n\u003cp\u003eNot all wall-mounted heat pump problems originate in the refrigeration circuit. An improper drain slope can cause water accumulation, overflow, or recurring maintenance issues.\u003c\/p\u003e\n\u003cp\u003eBefore installation, we therefore determine:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe exact position of the indoor unit;\u003c\/li\u003e\n\u003cli\u003ethe piping route;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain outlet;\u003c\/li\u003e\n\u003cli\u003ethe available slope;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit’s position;\u003c\/li\u003e\n\u003cli\u003ethe required electrical supply.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWhen gravity drainage is not possible, a condensate pump may be necessary. However, we prefer natural drainage whenever the building configuration allows it, since this reduces the number of mechanical components requiring maintenance.\u003c\/p\u003e\n\u003ch3\u003eCompact outdoor unit: 33 × 21 × 12.5 in\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit \u003cstrong\u003eDHP12CSB11S\u003c\/strong\u003e measures approximately \u003cstrong\u003e33 in × 21 in × 12.5 in\u003c\/strong\u003e, or 848 × 540 × 320 mm. Its stated sound pressure level is \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e. YORK also indicates a factory refrigerant charge of 31.74 oz, or approximately 0.9 kg. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese dimensions make it easier to integrate the unit on certain balconies, wall brackets, or side locations, but installation compliance always depends on the manufacturer’s clearances and the rules applicable to the building.\u003c\/p\u003e\n\u003cp\u003eIn Greater Montreal, the constraints are not the same for a bungalow on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, a Montreal duplex, a \u003cstrong\u003eLaval\u003c\/strong\u003e condo, or a townhouse in \u003cstrong\u003eLongueuil\u003c\/strong\u003e. The best location depends as much on service accessibility as on aesthetics and the surrounding area.\u003c\/p\u003e\n\u003ch3\u003eAn example of a situation where this 115 V YORK unit may be suitable\u003c\/h3\u003e\n\u003cp\u003eA scenario we regularly encounter during our estimates involves a homeowner who wants to cool and heat a main living area of approximately one zone, but does not want to unnecessarily modify the electrical installation.\u003c\/p\u003e\n\u003cp\u003eFor this type of project, a 12,000 BTU 115 V heat pump may be a good option if the calculated heat load actually matches this capacity.\u003c\/p\u003e\n\u003cp\u003eWe then check several factors before recommending the model:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003einsulation and sun exposure\u003c\/strong\u003e, the room’s area and volume, the number of windows, airflow to adjacent rooms, existing heating, electrical panel capacity, and the outdoor unit’s location.\u003c\/p\u003e\n\u003cp\u003eThis approach avoids a common mistake: automatically choosing 12,000 BTU solely because the area seems to match a chart found online.\u003c\/p\u003e\n\u003cp\u003eTwo homes of the same size can have very different heating loads.\u003c\/p\u003e\n\u003ch3\u003eWhen we would instead direct the customer toward another heat pump\u003c\/h3\u003e\n\u003cp\u003eThe YORK P Series 12,000 BTU 115 V is not intended for every project.\u003c\/p\u003e\n\u003cp\u003eWe would consider a different solution when a customer is primarily looking for:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ean ENERGY STAR Cold Climate-certified heat pump\u003c\/strong\u003e, documented performance at -25 °C or -30 °C, eligibility for a current subsidy based on a list of qualified equipment, a next-generation refrigerant, or significantly higher seasonal efficiency.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product sheet for this model currently indicates \u003cstrong\u003eENERGY STAR: No\u003c\/strong\u003e, \u003cstrong\u003eENERGY STAR Cold Climate: No\u003c\/strong\u003e, and no provincial LogisVert subsidy associated with the product.\u003c\/p\u003e\n\u003cp\u003eThis YORK should therefore be considered for what it is: a 115 V Inverter wall-mounted heat pump from an earlier generation, offering an interesting solution for certain targeted projects, but it should not be presented as equivalent to a latest-generation ultra-low-temperature heat pump.\u003c\/p\u003e\n\u003cp\u003eThis transparency helps a homeowner make a good decision far more than a comparison based solely on price or the number of BTUs.\u003c\/p\u003e\n\u003ch3\u003eWarranty: check the registration terms\u003c\/h3\u003e\n\u003cp\u003eOur AirGreen product sheet lists a warranty of \u003cstrong\u003e10 years on the compressor, 10 years on parts, and no manufacturer labor warranty indicated in this format\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 2020 YORK brochure does, however, provide an important clarification: it presented a standard warranty of \u003cstrong\u003e7 years on the compressor and 5 years on parts\u003c\/strong\u003e, extended to \u003cstrong\u003e10 years on the compressor and 10 years on parts after online registration for eligible residential installations\u003c\/strong\u003e. Labor coverage was presented separately as a paid option. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor this reason, we always recommend confirming the terms applicable to the serial number of the product actually sold and completing the required registration after installation. The conditions in a brochure published several years ago should not automatically be assumed to be identical to those of the product sold today.\u003c\/p\u003e\n\u003ch3\u003eThree errors we seek to avoid with this type of installation\u003c\/h3\u003e\n\u003cp\u003eThe first is to consider the \u003cstrong\u003e115 V\u003c\/strong\u003e as permission to connect the heat pump to any existing circuit. With an MCA of 20 A and an MOCP of 30 A, the electrical design must be done correctly.\u003c\/p\u003e\n\u003cp\u003eThe second is installing the indoor unit without considering the airflow direction. Even with vertical and horizontal swing, a head aimed directly at a bed or work table can become uncomfortable.\u003c\/p\u003e\n\u003cp\u003eThe third is choosing capacity based solely on floor area. A proper \u003cstrong\u003ewall-mounted heat pump installation\u003c\/strong\u003e considers the building as a whole: insulation, windows, orientation, ceiling height, open rooms, and winter heating needs.\u003c\/p\u003e\n\u003ch3\u003eYORK P Series Maintenance\u003c\/h3\u003e\n\u003cp\u003eLike any wall-mounted heat pump, this YORK unit must maintain a clean heat exchanger and sufficient airflow.\u003c\/p\u003e\n\u003cp\u003eThe homeowner can periodically clean the accessible filters of the indoor unit. When the blower wheel, evaporator, or drain pan accumulates dust or deposits, \u003cstrong\u003edeep cleaning of a wall-mounted heat pump\u003c\/strong\u003e becomes advisable.\u003c\/p\u003e\n\u003cp\u003eReduced airflow, a persistent odor, water flowing indoors, or a significant change in performance are signs that warrant an inspection.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit must also have sufficient clearance around its heat exchanger. In winter, snow or ice buildup around the outdoor unit can restrict airflow and compromise operation.\u003c\/p\u003e\n\u003ch3\u003eIs the YORK P Series 12,000 BTU 115 V still a suitable choice?\u003c\/h3\u003e\n\u003cp\u003eIt can be when the building’s characteristics precisely match its strengths.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e115 V\u003c\/strong\u003e power supply, relatively common \u003cstrong\u003e1\/4 in - 3\/8 in\u003c\/strong\u003e piping, compact format, Inverter modulation, heating operation down to -20 °C, and motorized louvers on both axes make it a practical solution for certain residential or light commercial projects.\u003c\/p\u003e\n\u003cp\u003eHowever, homeowners who prioritize heating in extreme cold or available rebates should compare this unit with newer generations before making a decision.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, our job is precisely to make this comparison before installation, not afterward.\u003c\/p\u003e\n\u003ch3\u003eWhy have AirGreen assess the project\u003c\/h3\u003e\n\u003cp\u003eWe install and maintain HVAC systems throughout \u003cstrong\u003eGreater Montreal\u003c\/strong\u003e, including \u003cstrong\u003eMontreal, Laval, Longueuil, Boucherville, the South Shore, and the North Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDuring an assessment, we can verify the capacity actually required, the electrical configuration, the piping route, drainage, the outdoor unit’s location, and whether investing in this model rather than a newer heat pump makes sense.\u003c\/p\u003e\n\u003cp\u003eThe goal is not to automatically sell the equipment with the most impressive specifications. We seek an installation that is appropriate for the building, budget, and intended use.\u003c\/p\u003e\n\u003ch3\u003eFAQ – YORK P Series 12,000 BTU 115 V\u003c\/h3\u003e\n\u003ch4\u003eWhat is the outdoor model number?\u003c\/h4\u003e\n\u003cp\u003eThe outdoor unit is the \u003cstrong\u003eYORK DHP12CSB11S\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat is the indoor model number?\u003c\/h4\u003e\n\u003cp\u003eThe indoor wall-mounted unit is the \u003cstrong\u003eDHP12NWB11S\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat is the cooling capacity?\u003c\/h4\u003e\n\u003cp\u003eThe rated capacity is \u003cstrong\u003e12,000 BTU\/h\u003c\/strong\u003e, with an advertised modulating range of \u003cstrong\u003e3,753 to 12,500 BTU\/h\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat is the heating capacity?\u003c\/h4\u003e\n\u003cp\u003eThe rated capacity is \u003cstrong\u003e13,000 BTU\/h\u003c\/strong\u003e, with a range of \u003cstrong\u003e3,412 to 15,013 BTU\/h\u003c\/strong\u003e under the conditions specified by YORK.\u003c\/p\u003e\n\u003ch4\u003eDown to what outdoor temperature can it provide heating?\u003c\/h4\u003e\n\u003cp\u003eThe published heating operating range extends down to \u003cstrong\u003e-20 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eDoes it operate at 115 V?\u003c\/h4\u003e\n\u003cp\u003eYes. It operates at \u003cstrong\u003e115 V, single-phase, 60 Hz\u003c\/strong\u003e. This does not eliminate the need to provide an electrical circuit that complies with the unit’s requirements.\u003c\/p\u003e\n\u003ch4\u003eWhat piping does it use?\u003c\/h4\u003e\n\u003cp\u003eThe refrigerant piping is \u003cstrong\u003e1\/4 in. for liquid and 3\/8 in. for gas\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat piping length can be installed?\u003c\/h4\u003e\n\u003cp\u003eThe documentation indicates up to \u003cstrong\u003e65 ft of total length\u003c\/strong\u003e, with a maximum height difference of \u003cstrong\u003e33 ft\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eIs Wi-Fi included?\u003c\/h4\u003e\n\u003cp\u003eWi-Fi is \u003cstrong\u003eoptional\u003c\/strong\u003e and requires the \u003cstrong\u003eCS532AH\u003c\/strong\u003e adapter.\u003c\/p\u003e\n\u003ch4\u003eDo the louvers move automatically horizontally and vertically?\u003c\/h4\u003e\n\u003cp\u003eYes. YORK’s P Series function table lists automatic vertical and horizontal swing, as well as up\/down and left\/right movement functions.\u003c\/p\u003e\n\u003ch4\u003eIs it ENERGY STAR Cold Climate?\u003c\/h4\u003e\n\u003cp\u003eThe AirGreen product page indicates \u003cstrong\u003eNo\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eIs it eligible for LogisVert?\u003c\/h4\u003e\n\u003cp\u003eThe AirGreen product page currently lists \u003cstrong\u003eno LogisVert rebate\u003c\/strong\u003e for this configuration. If the rebate is important for your project, we recommend comparing it with eligible heat pumps available at the time of purchase.\u003c\/p\u003e\n\u003ch3\u003eRequest an AirGreen estimate\u003c\/h3\u003e\n\u003cp\u003eAre you considering the \u003cstrong\u003eYORK P Series 12,000 BTU 115 V\u003c\/strong\u003e, or would you like to know whether a newer heat pump would be better suited to your property? \u003cstrong\u003eContact AirGreen for an estimate and an analysis of your HVAC system\u003c\/strong\u003e in Montréal, Laval, Longueuil, the North Shore, or the South Shore. We can check the capacity, electrical supply, positioning, and available options before you commit to the work.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56120363581732,"sku":"DHP12CSB11S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_YORK_SERIE_P_12000_BTU_115V_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_8feb076e-bcc8-431d-a22c-4793fa5cd1fc.png?v=1789426074","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-york-serie-p-18-seer-12000-btu-115v","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}