{"product_id":"thermopompe-murale-york-serie-p-18-seer-24000-btu","title":"YORK P Series Wall-Mounted Heat Pump 18 SEER | 24000 BTU","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA 24,000 BTU wall-mounted heat pump that deserves to be assessed beyond the number on the label\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eWhen a homeowner is looking for a \u003cstrong\u003e24,000 BTU wall-mounted heat pump in Montreal, Laval, Longueuil, on the North Shore or South Shore\u003c\/strong\u003e, the stated capacity is often the first criterion considered. However, to determine whether a unit is truly suitable for a large open-concept area, an entire floor, a commercial space or a difficult-to-cool dwelling, we need to look much further: capacity modulation, airflow, sound level, minimum heating temperature, piping, electrical supply and the location of both units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK P Series\u003c\/strong\u003e, in the configuration of interest here, pairs the \u003cstrong\u003eDHP24NWB21S\u003c\/strong\u003e indoor unit with the \u003cstrong\u003eDHP24CSB21S\u003c\/strong\u003e outdoor unit. YORK officially classifies this combination in its \u003cstrong\u003e24K BTU\/h, 208\/230 V\u003c\/strong\u003e family, among the P Series single-zone wall-mounted heat pump systems. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an \u003cstrong\u003eInverter\u003c\/strong\u003e-technology heat pump using \u003cstrong\u003eR-410A\u003c\/strong\u003e, designed to provide cooling and heating down to an advertised outdoor temperature of \u003cstrong\u003e-20 °C\u003c\/strong\u003e. It is therefore not simply a wall-mounted air conditioner with a heating function added: it is a reversible system capable of modulating its operation according to the building’s actual load.\u003c\/p\u003e\n\u003ch3\u003eYORK P Series 24K: model numbers to verify before any installation\u003c\/h3\u003e\n\u003cp\u003eFor this heat pump, the correct combination is:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: DHP24NWB21S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: DHP24CSB21S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommercial class: 24,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-410A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI listed on the AirGreen product sheet: 8578549\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWi-Fi: optional\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis distinction between the indoor and outdoor units is important. On a \u003cstrong\u003ewall-mounted heat pump replacement\u003c\/strong\u003e project, we never validate an installation solely based on the YORK logo or the appearance of the wall-mounted unit. Both model numbers must be confirmed, particularly when an existing appliance is being partially reused or when verifying an older installation.\u003c\/p\u003e\n\u003ch3\u003e“18 SEER” does not mean that every P Series capacity achieves exactly 18 SEER\u003c\/h3\u003e\n\u003cp\u003eHere is a particularly important nuance for this product listing.\u003c\/p\u003e\n\u003cp\u003eYORK presents this range as the \u003cstrong\u003eP Series up to 18 SEER\u003c\/strong\u003e. However, in the official technical table of the 2020 catalog, the \u003cstrong\u003eDHP24NWB21S \/ DHP24CSB21S\u003c\/strong\u003e combination is listed with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSEER: 16\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER: 9.75\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF: 9\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRated cooling capacity: \u003cstrong\u003e22,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003enominal heating capacity: \u003cstrong\u003e23,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe table also indicates a cooling modulation range of \u003cstrong\u003e8,630 to 23,200 BTU\/h\u003c\/strong\u003e, and a heating range of \u003cstrong\u003e8,650 to 26,000 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThat is why we always distinguish between a \u003cstrong\u003e24,000 BTU commercial category\u003c\/strong\u003e and the nominal capacity measured under standardized conditions. A unit sold as “24K” is not necessarily rated at exactly 24,000 BTU\/h under all certification conditions.\u003c\/p\u003e\n\u003cp\u003eIt is also important to avoid mixing different generations of standards. This 2020 YORK catalogue provides \u003cstrong\u003eSEER, EER and HSPF\u003c\/strong\u003e ratings, not the newer \u003cstrong\u003eSEER2, EER2 and HSPF2\u003c\/strong\u003e ratings. These values should not be automatically converted or renamed. To compare this YORK with a recent heat pump using a SEER2 rating, we therefore recommend comparing the technical specifications according to the same standard rather than placing the figures side by side without context.\u003c\/p\u003e\n\u003ch3\u003eUseful modulation in large spaces\u003c\/h3\u003e\n\u003cp\u003eVariable capacity is one of the practical advantages of Inverter technology.\u003c\/p\u003e\n\u003cp\u003eIn cooling mode, the YORK can go down to around \u003cstrong\u003e8,630 BTU\/h\u003c\/strong\u003e instead of constantly operating at full capacity. In heating mode, it can modulate from approximately \u003cstrong\u003e8,650 to 26,000 BTU\/h\u003c\/strong\u003e under the conditions specified in YORK’s documentation. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a homeowner, this may mean longer, more consistent cycles, particularly when the outdoor temperature is moderate and the building does not require the unit’s full capacity.\u003c\/p\u003e\n\u003cp\u003eOn our \u003cstrong\u003eductless mini-split heat pump projects in Greater Montreal\u003c\/strong\u003e, this is precisely the behavior we look for when the unit serves an open-concept area: a dining room connected to the living room, an open kitchen, a large basement, or a business where the heat load changes throughout the day.\u003c\/p\u003e\n\u003cp\u003eHowever, achieving the right result depends on proper sizing. Automatically installing a 24,000 BTU unit simply because the room “seems large” is a mistake. The floor area, insulation, windows, solar exposure, ceiling height, and airflow between rooms must all be considered.\u003c\/p\u003e\n\u003ch3\u003eHeating down to -20 °C: what this figure really means\u003c\/h3\u003e\n\u003cp\u003eYORK gives the \u003cstrong\u003eDHP24CSB21S\u003c\/strong\u003e a heating operating range of \u003cstrong\u003e-4 °F to 75 °F\u003c\/strong\u003e, or approximately \u003cstrong\u003e-20 °C to 24 °C\u003c\/strong\u003e. In cooling mode, its published range is \u003cstrong\u003e-18 °C to 46 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e-20 °C\u003c\/strong\u003e must be interpreted correctly.\u003c\/p\u003e\n\u003cp\u003eThis represents a published operating limit, not a promise that the unit will always produce exactly its rated capacity of 23,000 BTU\/h at -20 °C. As with any heat pump, capacity and efficiency vary with the outdoor temperature.\u003c\/p\u003e\n\u003cp\u003eIn the climate of \u003cstrong\u003eMontreal, Laval, Longueuil, Boucherville, and Montérégie\u003c\/strong\u003e, this distinction is particularly important. For a home that relies primarily on the heat pump during the winter, we always check the building's heating load and the presence of an appropriate backup heating system.\u003c\/p\u003e\n\u003ch3\u003eHigh airflow to distribute the available capacity\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit \u003cstrong\u003eDHP24NWB21S\u003c\/strong\u003e has four published airflow rates:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e706 \/ 647 \/ 588 \/ 530 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts corresponding sound pressure levels are listed as:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e48 \/ 44 \/ 40 \/ 36 dB(A)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts dimensions are \u003cstrong\u003e42 × 13 × 10 in\u003c\/strong\u003e, or approximately \u003cstrong\u003e1,078 × 325 × 246 mm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum airflow of \u003cstrong\u003e706 CFM\u003c\/strong\u003e is particularly relevant for a heat pump of this capacity. A 24K unit installed in an overly enclosed area may have plenty of available capacity without being able to distribute it effectively.\u003c\/p\u003e\n\u003cp\u003eThis is a situation we avoid when preparing our estimates: installing a large heat pump in a narrow corridor in the hope of heating four bedrooms whose doors remain closed rarely produces the expected result.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eindoor unit's position\u003c\/strong\u003e matters almost as much as the number of BTUs.\u003c\/p\u003e\n\u003ch3\u003eAutomatic vertical and horizontal louvers: yes, the P Series has them\u003c\/h3\u003e\n\u003cp\u003eYORK documentation is particularly interesting on this point. The P Series function table confirms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eautomatic 3D vertical and horizontal swing\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eup\/down movement;\u003c\/li\u003e\n\u003cli\u003eleft\/right movement;\u003c\/li\u003e\n\u003cli\u003efixed-angle louver positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn other words, for this series, the \u003cstrong\u003evertical and horizontal louvers can be controlled automatically\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis detail is much more important than it may seem for a high-capacity unit. In an open area, we can direct the airflow toward a distant zone rather than concentrating all the air conditioning directly beneath the unit.\u003c\/p\u003e\n\u003cp\u003eHowever, poor placement can negate this advantage. Installing the wall-mounted unit behind a large cabinet, too close to a beam, or facing a wall only a few meters away inevitably limits the air-throw range.\u003c\/p\u003e\n\u003ch3\u003eWi-Fi available, but via adapter\u003c\/h3\u003e\n\u003cp\u003eThe P Series does not include Wi-Fi in the same way as some newer heat pumps. YORK lists the \u003cstrong\u003eEWPE Smart\u003c\/strong\u003e app, available for the P, X, and Z Series, but specifies that a \u003cstrong\u003eCS532AH adapter is required for the P and X Series\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore accurately describe this feature as \u003cstrong\u003eoptional Wi-Fi\u003c\/strong\u003e, not built-in Wi-Fi as standard.\u003c\/p\u003e\n\u003cp\u003eThe wireless \u003cstrong\u003eDRCPX\u003c\/strong\u003e remote control is supplied as the standard controller with the P Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eInstallation in Montreal, Laval, Longueuil, the North Shore, and the South Shore: the details that determine the result\u003c\/h2\u003e\n\u003cp\u003eA \u003cstrong\u003eYORK DHP24CSB21S\u003c\/strong\u003e heat pump is relatively easy to understand on paper. On an actual job site, the quality of the result depends on dozens of details that do not appear in the product title.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we assess, among other things, the indoor unit's location, the length of the refrigerant run, the height difference between the units, condensate drainage, the electrical supply, potential vibration from the outdoor unit, and future access for maintenance.\u003c\/p\u003e\n\u003ch3\u003ePiping: 1\/4 in. liquid and 5\/8 in. gas\u003c\/h3\u003e\n\u003cp\u003eFor the 24K system, YORK specifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid line: \u003cstrong\u003e1\/4 po\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas line: \u003cstrong\u003e5\/8 po\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDrain: \u003cstrong\u003e5\/8 po\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum total piping length: \u003cstrong\u003e82 ft \/ 25 m\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePublished maximum height difference: \u003cstrong\u003e33 ft \/ 10 m\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis is something to check carefully during a replacement.\u003c\/p\u003e\n\u003cp\u003eWe regularly encounter properties where an old heat pump already has refrigerant lines installed in the walls. The fact that these lines are physically present does not guarantee that they are suitable for the new system. \u003cstrong\u003eThe diameter, condition, cleanliness, and compatibility must be verified before deciding to keep them.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the DHP24CSB21S, the \u003cstrong\u003e1\/4 – 5\/8 in.\u003c\/strong\u003e combination must therefore be taken seriously.\u003c\/p\u003e\n\u003ch3\u003eA 208\/230 V power supply and suitable electrical protection\u003c\/h3\u003e\n\u003cp\u003eThe YORK 24K heat pump combination is powered by \u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e. For the DHP24 heat pump model, the manufacturer specifies an \u003cstrong\u003eMCA of 16 A\u003c\/strong\u003e and an \u003cstrong\u003eMOCP of 25 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn practice, this data is used to correctly determine the circuit and electrical protection according to the manufacturer's requirements and applicable standards.\u003c\/p\u003e\n\u003cp\u003eWe never recommend simply choosing a circuit breaker based on estimated average consumption. The \u003cstrong\u003eMCA\u003c\/strong\u003e and \u003cstrong\u003emaximum overcurrent protection\u003c\/strong\u003e are among the data that must be verified before work begins.\u003c\/p\u003e\n\u003ch3\u003eOutdoor dimensions and clearances\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDHP24CSB21S\u003c\/strong\u003e outdoor module measures approximately:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e38 × 28 × 16 in\u003c\/strong\u003e\u003cbr\u003eor \u003cstrong\u003e955 × 700 × 396 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts published outdoor sound level is \u003cstrong\u003e59 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor an installation on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, or in the denser areas of \u003cstrong\u003eLaval and Longueuil\u003c\/strong\u003e, we must consider not only the physical space occupied by the unit, but also:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eaccess for servicing;\u003c\/li\u003e\n\u003cli\u003ethe clearances required around the heat exchanger;\u003c\/li\u003e\n\u003cli\u003esnow;\u003c\/li\u003e\n\u003cli\u003ewater discharge from defrosting;\u003c\/li\u003e\n\u003cli\u003eproximity to windows;\u003c\/li\u003e\n\u003cli\u003evibrations transmitted to the structure;\u003c\/li\u003e\n\u003cli\u003emunicipal requirements applicable to the location of a heat pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA properly selected but poorly positioned unit can become unnecessarily noisy or difficult to maintain.\u003c\/p\u003e\n\u003ch3\u003eMistakes we seek to avoid with a 24,000 BTU heat pump\u003c\/h3\u003e\n\u003cp\u003eA durable installation involves more than mounting two units and connecting them with a pair of pipes.\u003c\/p\u003e\n\u003cp\u003eAmong the issues we systematically seek to eliminate in our \u003cstrong\u003eHVAC installations in Montreal, Laval, Longueuil, the North Shore, and the South Shore\u003c\/strong\u003e are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ean indoor unit that is much too large for the room;\u003c\/li\u003e\n\u003cli\u003ean airflow directed straight at a bed, sofa, or work table;\u003c\/li\u003e\n\u003cli\u003ean insufficient drain slope;\u003c\/li\u003e\n\u003cli\u003eexisting piping with the wrong diameter;\u003c\/li\u003e\n\u003cli\u003ean outdoor support that amplifies vibrations;\u003c\/li\u003e\n\u003cli\u003ean outdoor unit positioned too close to an obstruction;\u003c\/li\u003e\n\u003cli\u003ea power supply selected without consulting the MCA and MOCP;\u003c\/li\u003e\n\u003cli\u003ea much longer refrigerant line set than expected;\u003c\/li\u003e\n\u003cli\u003ea poor understanding of the available capacity in extremely cold weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA \u003cstrong\u003e24,000 BTU\u003c\/strong\u003e unit is particularly sensitive to its location because of its high airflow. In a large open-concept area, this is an advantage. In a small enclosed room, however, it can create discomfort.\u003c\/p\u003e\n\u003ch3\u003eMaintaining a YORK P Series: preserving airflow before the problem becomes noticeable\u003c\/h3\u003e\n\u003cp\u003eThe airflow from a wall-mounted unit depends directly on the cleanliness of the filters, evaporator, and blower wheel.\u003c\/p\u003e\n\u003cp\u003eA unit capable of moving up to \u003cstrong\u003e706 CFM\u003c\/strong\u003e will not deliver the same results if the blower wheel is covered in dust or if the heat exchanger is clogged. The homeowner may sometimes feel that “the heat pump no longer cools like it used to,” when the problem is primarily related to airflow.\u003c\/p\u003e\n\u003cp\u003eWe therefore recommend periodically inspecting the filters and carrying out a \u003cstrong\u003ethorough cleaning of the wall-mounted heat pump\u003c\/strong\u003e when internal buildup warrants it. This is particularly relevant in homes with pets, open kitchens, dusty environments, and installations that operate almost continuously.\u003c\/p\u003e\n\u003ch3\u003eWarranty: clearly distinguish the YORK warranty from labour coverage\u003c\/h3\u003e\n\u003cp\u003eThe YORK catalog indicates a standard warranty of \u003cstrong\u003e7 years on the compressor and 5 years on parts\u003c\/strong\u003e, with the option to extend it to \u003cstrong\u003e10 years on the compressor and 10 years on parts\u003c\/strong\u003e after eligible registration. The document also mentions a 10-year labour protection option subject to additional conditions. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product sheet, for its part, shows \u003cstrong\u003e10-10-0 years\u003c\/strong\u003e of coverage and indicates that an \u003cstrong\u003eadditional warranty may be available\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTo avoid any confusion, the warranty applicable to a given installation should always be confirmed at the time of purchase, particularly for a model from an older product generation.\u003c\/p\u003e\n\u003ch3\u003eIs this YORK eligible for a LogisVert rebate?\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet provided for this model states:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eENERGY STAR: No\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eENERGY STAR Cold Climate: No\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eand no provincial rebate amount is currently listed.\u003c\/p\u003e\n\u003cp\u003eWe therefore do not recommend choosing this heat pump on the assumption that financial assistance will automatically be available. When a \u003cstrong\u003eheat pump rebate in Quebec\u003c\/strong\u003e is part of a project's financial calculation, we verify the specific model's eligibility before signing.\u003c\/p\u003e\n\u003cp\u003eThis is particularly important when a homeowner compares this YORK with a newer cold-climate heat pump whose initial price is higher but which may qualify for a different incentive program.\u003c\/p\u003e\n\u003ch3\u003eWho is this YORK 24K wall-mounted heat pump suitable for?\u003c\/h3\u003e\n\u003cp\u003eThis configuration may be suitable for a homeowner seeking a \u003cstrong\u003ehigh-capacity single-zone wall-mounted heat pump\u003c\/strong\u003e, particularly for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea large open area;\u003c\/li\u003e\n\u003cli\u003ean open-concept floor;\u003c\/li\u003e\n\u003cli\u003ea large basement;\u003c\/li\u003e\n\u003cli\u003ea commercial space;\u003c\/li\u003e\n\u003cli\u003ea room with a significant cooling load;\u003c\/li\u003e\n\u003cli\u003ea replacement where the existing mechanical and electrical specifications match the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is less attractive if the project primarily requires \u003cstrong\u003eENERGY STAR Cold Climate\u003c\/strong\u003e certification, documented performance at very low temperatures below -20°C, or newer refrigerant technology.\u003c\/p\u003e\n\u003cp\u003eThe choice must therefore be based on the complete project, not solely on the \u003cstrong\u003eYORK\u003c\/strong\u003e name, the \u003cstrong\u003e18 SEER\u003c\/strong\u003e rating, or the \u003cstrong\u003e24,000 BTU\u003c\/strong\u003e capacity.\u003c\/p\u003e\n\u003ch3\u003eWhy an on-site estimate remains important for a 24K heat pump\u003c\/h3\u003e\n\u003cp\u003eTwo homes with exactly the same floor area may require two different HVAC solutions.\u003c\/p\u003e\n\u003cp\u003eIn \u003cstrong\u003eMontréal\u003c\/strong\u003e, a century-old home with poorly insulated walls and large windows does not have the same thermal profile as a recently built condo of comparable size in \u003cstrong\u003eBoucherville\u003c\/strong\u003e. In \u003cstrong\u003eLaval\u003c\/strong\u003e, a bungalow with an open basement does not distribute air in the same way as a multistory cottage. In \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the available location for the outdoor unit can also completely change the piping route.\u003c\/p\u003e\n\u003cp\u003eThat is why, at \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we use the estimate to determine:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe capacity actually required;\u003c\/li\u003e\n\u003cli\u003ethe best indoor location;\u003c\/li\u003e\n\u003cli\u003ethe best outdoor location;\u003c\/li\u003e\n\u003cli\u003ethe route of the lines;\u003c\/li\u003e\n\u003cli\u003eelectrical requirements;\u003c\/li\u003e\n\u003cli\u003eaccess constraints;\u003c\/li\u003e\n\u003cli\u003edrainage;\u003c\/li\u003e\n\u003cli\u003esupplementary heating options;\u003c\/li\u003e\n\u003cli\u003eand the model’s value compared with the heat pumps currently available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOur review of the YORK P Series DHP24: a technical data sheet more interesting than its simple title\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK P Series 18 SEER | 24000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is a good example of the importance of reading technical data in detail.\u003c\/p\u003e\n\u003cp\u003eIt is indeed a unit from the \u003cstrong\u003e24K P Series family\u003c\/strong\u003e, but the YORK table gives this specific combination a rated cooling capacity of \u003cstrong\u003e22,000 BTU\/h\u003c\/strong\u003e, a heating capacity of \u003cstrong\u003e23,000 BTU\/h\u003c\/strong\u003e, a \u003cstrong\u003eSEER of 16\u003c\/strong\u003e, an \u003cstrong\u003eHSPF of 9\u003c\/strong\u003e, heating operation down to \u003cstrong\u003e-20 °C\u003c\/strong\u003e, airflow of up to \u003cstrong\u003e706 CFM\u003c\/strong\u003e, \u003cstrong\u003e1\/4–5\/8 in.\u003c\/strong\u003e piping, and a \u003cstrong\u003e208\/230 V\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\u003cp\u003eIt also offers a real distribution advantage with \u003cstrong\u003eautomatic vertical and horizontal swing\u003c\/strong\u003e, while Wi-Fi control remains available with the appropriate adapter.\u003c\/p\u003e\n\u003cp\u003eThese are the details that determine whether it is truly suitable for a property, rather than relying on three figures in a title.\u003c\/p\u003e\n\u003ch3\u003eRequest an AirGreen estimate for your YORK heat pump\u003c\/h3\u003e\n\u003cp\u003eAre you considering installing or replacing a \u003cstrong\u003eYORK wall-mounted heat pump in Montréal, Laval, Longueuil, the North Shore, the South Shore, or Montérégie\u003c\/strong\u003e? Contact \u003cstrong\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e. We can assess the required capacity, location, piping, electrical requirements, and currently available options to propose an HVAC solution suited to your building.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56120363942180,"sku":"DHP24CSB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_YORK_SERIE_P_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_bd2da4c6-0e63-4bce-ac05-620c85ad7020.png?v=1789426116","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-york-serie-p-18-seer-24000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}