{"product_id":"thermopompe-murale-zephyr-cb22-r32-12000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 12000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"59\" class=\"PDq2pG_selectionAnchorContainer\"\u003eZephyr CB22 R32 12,000 BTU Wall-Mounted Heat Pump — ZE-12CB22\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"61\" data-end=\"155\"\u003eA simple, efficient 12,000 BTU wall-mounted heat pump well suited to residential needs\u003c\/h2\u003e\n\u003cp data-start=\"157\" data-end=\"512\"\u003eThe \u003cstrong data-start=\"160\" data-end=\"209\"\u003eZephyr CB22 R32 12,000 BTU wall-mounted heat pump\u003c\/strong\u003e, model \u003cstrong data-start=\"218\" data-end=\"231\"\u003eZE-12CB22\u003c\/strong\u003e, is aimed at homeowners looking for a reliable HVAC solution to cool and heat a living room, condo, master bedroom, office, small business, or residential area where comfort must remain stable without installing a full central system.\u003c\/p\u003e\n\u003cp data-start=\"514\" data-end=\"934\"\u003eAt AirGreen, we recommend this type of unit when the customer wants an affordable, compact, discreet wall-mounted heat pump capable of meeting the essential needs of the Quebec climate. The \u003cstrong data-start=\"717\" data-end=\"730\"\u003eZE-12CB22\u003c\/strong\u003e is not designed for very large open spaces like an 18,000 or 24,000 BTU unit, but it can be an excellent choice when properly sized for the room to be treated.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1319\"\u003eThis model stands out for several important features: its \u003cstrong data-start=\"1010\" data-end=\"1041\"\u003e12,000 BTU cooling capacity\u003c\/strong\u003e, operation with \u003cstrong data-start=\"1065\" data-end=\"1084\"\u003eR32 refrigerant\u003c\/strong\u003e, power supply of \u003cstrong data-start=\"1106\" data-end=\"1121\"\u003e208V \/ 230V\u003c\/strong\u003e, \u003cstrong data-start=\"1127\" data-end=\"1155\"\u003eheating down to -25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1161\" data-end=\"1177\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1183\" data-end=\"1196\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1202\" data-end=\"1216\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1222\" data-end=\"1249\"\u003eautomatic oscillation\u003c\/strong\u003e, \u003cstrong data-start=\"1255\" data-end=\"1266\"\u003e4D mode\u003c\/strong\u003e, and a basic warranty of \u003cstrong data-start=\"1293\" data-end=\"1318\"\u003e10 years on parts\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1321\" data-end=\"1716\"\u003eThe Zephyr CB22 R32 heat pump deserves serious analysis before installation. You need to consider the actual room size, ceiling height, insulation, window orientation, sun exposure, air circulation, indoor unit location, distance from the outdoor unit, drainage, outdoor clearances, and electrical panel capacity.\u003c\/p\u003e\n\u003cp data-start=\"1718\" data-end=\"2107\"\u003eAt AirGreen, we have installed enough wall-mounted heat pumps in Montreal, Laval, Longueuil, on the South Shore and the North Shore to know that a \u003cstrong data-start=\"1873\" data-end=\"1887\"\u003e12,000 BTU\u003c\/strong\u003e unit can provide excellent comfort when installed in the right place. Conversely, even an efficient device can disappoint if it is poorly placed, improperly sized, or installed without considering the building’s realities.\u003c\/p\u003e\n\u003ch2 data-start=\"2109\" data-end=\"2167\"\u003eImportant technical characteristics to know\u003c\/h2\u003e\n\u003cp data-start=\"2169\" data-end=\"2331\"\u003eFor model \u003cstrong data-start=\"2184\" data-end=\"2197\"\u003eZE-12CB22\u003c\/strong\u003e, the Zephyr CB22 brochure datasheet provides the following key information:\u003c\/p\u003e\n\u003cp data-start=\"2333\" data-end=\"3953\"\u003e• \u003cstrong data-start=\"2335\" data-end=\"2354\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2354\" data-end=\"2357\"\u003e• \u003cstrong data-start=\"2359\" data-end=\"2375\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2375\" data-end=\"2378\"\u003e• \u003cstrong data-start=\"2380\" data-end=\"2402\"\u003eModel: ZE-12CB22\u003c\/strong\u003e\u003cbr data-start=\"2402\" data-end=\"2405\"\u003e• \u003cstrong data-start=\"2407\" data-end=\"2436\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2436\" data-end=\"2439\"\u003e• \u003cstrong data-start=\"2441\" data-end=\"2462\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2462\" data-end=\"2465\"\u003e• \u003cstrong data-start=\"2467\" data-end=\"2521\"\u003eCooling capacity at 35 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2521\" data-end=\"2524\"\u003e• \u003cstrong data-start=\"2526\" data-end=\"2575\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2575\" data-end=\"2578\"\u003e• \u003cstrong data-start=\"2580\" data-end=\"2594\"\u003eSEER2: 20\u003c\/strong\u003e\u003cbr data-start=\"2594\" data-end=\"2597\"\u003e• \u003cstrong data-start=\"2599\" data-end=\"2615\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2615\" data-end=\"2618\"\u003e• \u003cstrong data-start=\"2620\" data-end=\"2641\"\u003eEER2: 10.5 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2641\" data-end=\"2644\"\u003e• \u003cstrong data-start=\"2646\" data-end=\"2678\"\u003eHeating COP at 8.3 °C: 3.5\u003c\/strong\u003e\u003cbr data-start=\"2678\" data-end=\"2681\"\u003e• \u003cstrong data-start=\"2683\" data-end=\"2714\"\u003eCOP2 heating: 12.0 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2714\" data-end=\"2717\"\u003e• \u003cstrong data-start=\"2719\" data-end=\"2777\"\u003eNominal heating capacity at -8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003e• \u003cstrong data-start=\"2782\" data-end=\"2839\"\u003eMaximum heating capacity at -15 °C: 7,500 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2839\" data-end=\"2842\"\u003e• \u003cstrong data-start=\"2844\" data-end=\"2866\"\u003eCOP at -15 °C: 2.0\u003c\/strong\u003e\u003cbr data-start=\"2866\" data-end=\"2869\"\u003e• \u003cstrong data-start=\"2871\" data-end=\"2928\"\u003eMaximum heating capacity at -20 °C: 6,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2928\" data-end=\"2931\"\u003e• \u003cstrong data-start=\"2933\" data-end=\"2959\"\u003eEnergy Star V6.1: no\u003c\/strong\u003e\u003cbr data-start=\"2959\" data-end=\"2962\"\u003e• \u003cstrong data-start=\"2964\" data-end=\"3005\"\u003eIndoor airflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"3005\" data-end=\"3008\"\u003e• \u003cstrong data-start=\"3010\" data-end=\"3056\"\u003eRefrigerant charge volume: 21.87 oz\u003c\/strong\u003e\u003cbr data-start=\"3056\" data-end=\"3059\"\u003e• \u003cstrong data-start=\"3061\" data-end=\"3128\"\u003eIndoor sound pressure: 46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3128\" data-end=\"3131\"\u003e• \u003cstrong data-start=\"3133\" data-end=\"3178\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3178\" data-end=\"3181\"\u003e• \u003cstrong data-start=\"3183\" data-end=\"3224\"\u003eVoltage: 208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3224\" data-end=\"3227\"\u003e• \u003cstrong data-start=\"3229\" data-end=\"3273\"\u003eNominal cooling current: 5.2 A\u003c\/strong\u003e\u003cbr data-start=\"3273\" data-end=\"3276\"\u003e• \u003cstrong data-start=\"3278\" data-end=\"3318\"\u003eNominal heating current: 4.8 A\u003c\/strong\u003e\u003cbr data-start=\"3318\" data-end=\"3321\"\u003e• \u003cstrong data-start=\"3323\" data-end=\"3338\"\u003eMCA: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"3338\" data-end=\"3341\"\u003e• \u003cstrong data-start=\"3343\" data-end=\"3357\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"3357\" data-end=\"3360\"\u003e• \u003cstrong data-start=\"3362\" data-end=\"3428\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"3428\" data-end=\"3431\"\u003e• \u003cstrong data-start=\"3433\" data-end=\"3464\"\u003eLiquid piping: 1\/4 inch\u003c\/strong\u003e\u003cbr data-start=\"3464\" data-end=\"3467\"\u003e• \u003cstrong data-start=\"3469\" data-end=\"3496\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3496\" data-end=\"3499\"\u003e• \u003cstrong data-start=\"3501\" data-end=\"3551\"\u003ePiping length min-max: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3551\" data-end=\"3554\"\u003e• \u003cstrong data-start=\"3556\" data-end=\"3593\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3593\" data-end=\"3596\"\u003e• \u003cstrong data-start=\"3598\" data-end=\"3634\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3634\" data-end=\"3637\"\u003e• \u003cstrong data-start=\"3639\" data-end=\"3707\"\u003eIndoor unit dimensions: 33 7\/16 × 11 9\/16 × 8 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"3707\" data-end=\"3710\"\u003e• \u003cstrong data-start=\"3712\" data-end=\"3777\"\u003eOutdoor unit dimensions: 28 1\/8 × 21 1\/4 × 9 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"3777\" data-end=\"3780\"\u003e• \u003cstrong data-start=\"3782\" data-end=\"3843\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"3843\" data-end=\"3846\"\u003e• \u003cstrong data-start=\"3848\" data-end=\"3905\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"3905\" data-end=\"3908\"\u003e• \u003cstrong data-start=\"3910\" data-end=\"3953\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3955\" data-end=\"4381\"\u003eThese figures are not just technical data. They directly influence the feasibility of the project, the choice of circuit breaker, the routing of piping, the actual performance of the device, and the installation cost. For example, the model \u003cstrong data-start=\"4208\" data-end=\"4247\"\u003eZE-12CB22 operates at 208V \/ 230V\u003c\/strong\u003e, with a \u003cstrong data-start=\"4257\" data-end=\"4272\"\u003eMOP of 15 A\u003c\/strong\u003e and a \u003cstrong data-start=\"4279\" data-end=\"4295\"\u003eMCA of 9.5 A\u003c\/strong\u003e. This means the electrical supply must be checked before installation.\u003c\/p\u003e\n\u003ch2 data-start=\"4383\" data-end=\"4434\"\u003eA capacity of 12,000 BTU: for which spaces?\u003c\/h2\u003e\n\u003cp data-start=\"4436\" data-end=\"4734\"\u003eA wall-mounted heat pump of \u003cstrong data-start=\"4462\" data-end=\"4476\"\u003e12,000 BTU\u003c\/strong\u003e is often chosen for medium-sized spaces. It can suit a main room, a bedroom, an office, a condo, a family room, or a semi-open area, but the BTU number alone is never enough to confirm the right choice.\u003c\/p\u003e\n\u003cp data-start=\"4736\" data-end=\"4779\"\u003eWe always evaluate several elements:\u003c\/p\u003e\n\u003cp data-start=\"4781\" data-end=\"5213\"\u003e• \u003cstrong data-start=\"4783\" data-end=\"4832\"\u003ethe actual area to be cooled or heated\u003c\/strong\u003e;\u003cbr data-start=\"4833\" data-end=\"4836\"\u003e• \u003cstrong data-start=\"4838\" data-end=\"4865\"\u003ethe ceiling height\u003c\/strong\u003e;\u003cbr data-start=\"4866\" data-end=\"4869\"\u003e• \u003cstrong data-start=\"4871\" data-end=\"4898\"\u003ethe building insulation\u003c\/strong\u003e;\u003cbr data-start=\"4899\" data-end=\"4902\"\u003e• \u003cstrong data-start=\"4904\" data-end=\"4934\"\u003ethe orientation of the windows\u003c\/strong\u003e;\u003cbr data-start=\"4935\" data-end=\"4938\"\u003e• \u003cstrong data-start=\"4940\" data-end=\"4975\"\u003ethe solar load in the afternoon\u003c\/strong\u003e;\u003cbr data-start=\"4976\" data-end=\"4979\"\u003e• \u003cstrong data-start=\"4981\" data-end=\"5023\"\u003ethe level of openness between rooms\u003c\/strong\u003e;\u003cbr data-start=\"5024\" data-end=\"5027\"\u003e• \u003cstrong data-start=\"5029\" data-end=\"5054\"\u003ethe number of occupants\u003c\/strong\u003e;\u003cbr data-start=\"5055\" data-end=\"5058\"\u003e• \u003cstrong data-start=\"5060\" data-end=\"5089\"\u003ethe use of the room\u003c\/strong\u003e;\u003cbr data-start=\"5090\" data-end=\"5093\"\u003e• \u003cstrong data-start=\"5095\" data-end=\"5135\"\u003ethe presence of a supplementary heater\u003c\/strong\u003e;\u003cbr data-start=\"5136\" data-end=\"5139\"\u003e• \u003cstrong data-start=\"5141\" data-end=\"5212\"\u003ethe possible distance between the indoor unit and the outdoor unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5215\" data-end=\"5624\"\u003eIn a Montreal condo, the \u003cstrong data-start=\"5244\" data-end=\"5257\"\u003eZE-12CB22\u003c\/strong\u003e can be very interesting for a well-configured main area. In a house in Laval, it can be ideal for a master bedroom, a closed living room, or a home office. In Longueuil, on the South Shore or the North Shore, it can also suit a renovated space where you want to improve comfort without changing the entire existing heating system.\u003c\/p\u003e\n\u003cp data-start=\"5626\" data-end=\"6097\"\u003eA common mistake is choosing a heat pump simply because it seems “strong enough.” An overly powerful unit can reach the temperature too quickly in cooling mode, reduce dehumidification time, and create less stable comfort. Conversely, an underpowered unit will run for a long time without maintaining the desired temperature on very hot or very cold days. \u003cstrong data-start=\"6049\" data-end=\"6097\"\u003eProper sizing remains essential.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"6099\" data-end=\"6174\"\u003eR32 refrigerant: a modern technology for HVAC installations\u003c\/h2\u003e\n\u003cp data-start=\"6176\" data-end=\"6438\"\u003eThe Zephyr CB22 series uses \u003cstrong data-start=\"6208\" data-end=\"6227\"\u003eR32 refrigerant\u003c\/strong\u003e. This refrigerant is increasingly common in modern wall-mounted heat pumps because it allows manufacturers to design efficient, compact units suited to the new HVAC market requirements.\u003c\/p\u003e\n\u003cp data-start=\"6440\" data-end=\"6838\"\u003eFor the customer, the type of refrigerant may seem secondary, but it impacts the design of the unit, installation methods, tools used, and best practices to follow. An R32 installation must be done cleanly, with particular attention to connection quality, leak testing, vacuuming, and adherence to piping lengths.\u003c\/p\u003e\n\u003cp data-start=\"6840\" data-end=\"7183\"\u003eAt AirGreen, we always emphasize these steps. A modern heat pump should not be installed hastily. \u003cstrong data-start=\"6957\" data-end=\"7048\"\u003eProper flare, clean piping, thorough vacuuming, and a complete startup\u003c\/strong\u003e make all the difference between a durable installation and one that may cause problems after a few seasons.\u003c\/p\u003e\n\u003ch2 data-start=\"7185\" data-end=\"7239\"\u003eHeating down to -25 °C: what you need to understand\u003c\/h2\u003e\n\u003cp data-start=\"7241\" data-end=\"7569\"\u003eThe brochure presents the Zephyr CB22 as a heat pump capable of providing heating down to an outdoor temperature of \u003cstrong data-start=\"7369\" data-end=\"7379\"\u003e-25 °C\u003c\/strong\u003e. This is a very interesting point for Quebec, especially for customers who want to reduce the use of electric baseboards or improve the comfort of a specific area of the home.\u003c\/p\u003e\n\u003cp data-start=\"7571\" data-end=\"7960\"\u003eFor the model \u003cstrong data-start=\"7586\" data-end=\"7599\"\u003eZE-12CB22\u003c\/strong\u003e, the datasheet indicates a heating capacity of \u003cstrong data-start=\"7647\" data-end=\"7672\"\u003e12,000 BTU\/h at 8.3 °C\u003c\/strong\u003e, a nominal capacity of \u003cstrong data-start=\"7699\" data-end=\"7724\"\u003e9,000 BTU\/h at -8.3 °C\u003c\/strong\u003e, a maximum capacity of \u003cstrong data-start=\"7751\" data-end=\"7775\"\u003e7,500 BTU\/h at -15 °C\u003c\/strong\u003e, and a maximum capacity of \u003cstrong data-start=\"7804\" data-end=\"7828\"\u003e6,000 BTU\/h at -20 °C\u003c\/strong\u003e. These figures are very important because they show that the available power decreases as the outdoor temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"7962\" data-end=\"8338\"\u003eThis does not mean the device is not useful in winter. On the contrary, a well-chosen wall-mounted heat pump can provide a large part of the heating in a well-insulated area. However, it is important to remain realistic: \u003cstrong data-start=\"8183\" data-end=\"8258\"\u003eat very low temperatures, supplementary heating may still be necessary\u003c\/strong\u003e, especially in older, poorly insulated, or very windy homes.\u003c\/p\u003e\n\u003cp data-start=\"8340\" data-end=\"8657\"\u003eAt AirGreen, we always explain this reality before installation. The goal is not to sell an exaggerated promise but to offer an HVAC solution well suited to the building. The \u003cstrong data-start=\"8530\" data-end=\"8543\"\u003eZE-12CB22\u003c\/strong\u003e can be an excellent choice to improve winter comfort, provided its real capabilities are understood.\u003c\/p\u003e\n\u003ch2 data-start=\"8659\" data-end=\"8722\"\u003eAir conditioning down to -15 °C: useful in certain contexts\u003c\/h2\u003e\n\u003cp data-start=\"8724\" data-end=\"8990\"\u003eThe brochure also states that the air conditioning mode can cool down to an outdoor temperature of \u003cstrong data-start=\"8838\" data-end=\"8848\"\u003e-15 °C\u003c\/strong\u003e. For a residential owner, this information may seem less important, but it can be useful in certain specific contexts.\u003c\/p\u003e\n\u003cp data-start=\"8992\" data-end=\"9402\"\u003eSome spaces require cooling even when the outdoor temperature is cool: rooms with many electronic devices, small shops, offices, light server rooms, highly glazed areas, or spaces that accumulate heat due to sun exposure. In these cases, the ability to operate cooling at low outdoor temperatures can be an advantage.\u003c\/p\u003e\n\u003cp data-start=\"9404\" data-end=\"9592\"\u003eFor typical residential use, this feature is not always decisive, but it shows that the device was designed to offer good operational flexibility.\u003c\/p\u003e\n\u003ch2 data-start=\"9594\" data-end=\"9652\"\u003eEnergy efficiency: interpreting the numbers correctly\u003c\/h2\u003e\n\u003cp data-start=\"9654\" data-end=\"9853\"\u003eThe model \u003cstrong data-start=\"9664\" data-end=\"9677\"\u003eZE-12CB22\u003c\/strong\u003e features a \u003cstrong data-start=\"9689\" data-end=\"9704\"\u003eSEER2 of 20\u003c\/strong\u003e and a \u003cstrong data-start=\"9711\" data-end=\"9728\"\u003eHSPF2 IV of 9\u003c\/strong\u003e. These figures are used to assess the energy efficiency of the device, but they must be understood in context.\u003c\/p\u003e\n\u003cp data-start=\"9855\" data-end=\"10313\"\u003eThe \u003cstrong data-start=\"9858\" data-end=\"9867\"\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. The higher this number, the more efficient the device is over a cooling season. The \u003cstrong data-start=\"10012\" data-end=\"10021\"\u003eHSPF2\u003c\/strong\u003e relates to heating efficiency over a season. The \u003cstrong data-start=\"10076\" data-end=\"10084\"\u003eEER2\u003c\/strong\u003e, indicated at \u003cstrong data-start=\"10096\" data-end=\"10110\"\u003e10.5 BTU\/W\u003c\/strong\u003e, provides a measure of cooling efficiency under specific conditions. The \u003cstrong data-start=\"10192\" data-end=\"10199\"\u003eCOP\u003c\/strong\u003e, indicated at \u003cstrong data-start=\"10211\" data-end=\"10227\"\u003e3.5 to 8.3 °C\u003c\/strong\u003e, represents the ratio between thermal energy produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"10315\" data-end=\"10605\"\u003eFor a customer, the goal is not to memorize every indicator but to understand that these data influence electricity consumption. A well-used heat pump can help reduce energy costs, especially when it replaces part of direct electric heating.\u003c\/p\u003e\n\u003cp data-start=\"10607\" data-end=\"11110\"\u003eIt is also important to note: \u003cstrong data-start=\"10648\" data-end=\"10726\"\u003ethe technical sheet indicates Energy Star V6.1: no for the ZE-12CB22 model\u003c\/strong\u003e. This does not mean the device is ineffective, but it means it should not be presented as an Energy Star model according to the technical line specified for this capacity. At AirGreen, we always prefer to clarify this type of information before purchase to avoid any confusion regarding subsidies, certifications, or eligibility for certain programs.\u003c\/p\u003e\n\u003ch2 data-start=\"11112\" data-end=\"11172\"\u003eIndoor comfort: silent mode, night mode, and iFeel mode\u003c\/h2\u003e\n\u003cp data-start=\"11174\" data-end=\"11533\"\u003eThe brochure highlights several features focused on daily comfort. The \u003cstrong data-start=\"11259\" data-end=\"11272\"\u003eZE-12CB22\u003c\/strong\u003e notably offers \u003cstrong data-start=\"11294\" data-end=\"11310\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"11315\" data-end=\"11328\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"11333\" data-end=\"11347\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"11352\" data-end=\"11372\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"11377\" data-end=\"11394\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"11399\" data-end=\"11423\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"11428\" data-end=\"11456\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"11461\" data-end=\"11483\"\u003etwo-sided drain\u003c\/strong\u003e, and \u003cstrong data-start=\"11490\" data-end=\"11532\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11535\" data-end=\"12041\"\u003eThe \u003cstrong data-start=\"11538\" data-end=\"11554\"\u003esilent mode\u003c\/strong\u003e is particularly interesting for a bedroom, office, or room where noise must remain discreet. The sheet indicates an indoor sound pressure level that can drop to \u003cstrong data-start=\"11740\" data-end=\"11752\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, with levels of \u003cstrong data-start=\"11790\" data-end=\"11824\"\u003e46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on speeds. For a wall-mounted heat pump, this is an important point, as comfort is not limited to temperature. Noise, airflow direction, and operational stability also play a role.\u003c\/p\u003e\n\u003cp data-start=\"12043\" data-end=\"12396\"\u003eThe \u003cstrong data-start=\"12046\" data-end=\"12059\"\u003enight mode\u003c\/strong\u003e allows the device’s operation to be adapted during sleeping hours, while \u003cstrong data-start=\"12154\" data-end=\"12168\"\u003eiFeel mode\u003c\/strong\u003e helps better adjust the temperature according to the area where the remote control is located. This feature can be useful when the temperature near the wall unit is not exactly the same as that felt in the occupied area.\u003c\/p\u003e\n\u003ch2 data-start=\"12398\" data-end=\"12473\"\u003eAutomatic oscillation and 4D mode: better air distribution\u003c\/h2\u003e\n\u003cp data-start=\"12475\" data-end=\"12701\"\u003eThe brochure also presents \u003cstrong data-start=\"12504\" data-end=\"12531\"\u003eautomatic oscillation\u003c\/strong\u003e and \u003cstrong data-start=\"12538\" data-end=\"12549\"\u003e4D mode\u003c\/strong\u003e, designed to better distribute air in the room. The goal is to achieve a more balanced temperature and reduce cold or hot spots.\u003c\/p\u003e\n\u003cp data-start=\"12703\" data-end=\"13069\"\u003eIn practice, this feature is very important. A wall-mounted heat pump heats or cools not only by its power but also by its ability to move air properly. If the unit is poorly placed, the air may remain concentrated in one area. If it is well installed and well oriented, it can improve comfort throughout the room.\u003c\/p\u003e\n\u003cp data-start=\"13071\" data-end=\"13441\"\u003eThe brochure also mentions that variable frequency technology allows the heat pump to adjust its power in real time. This technology helps reduce temperature fluctuations and limit energy consumption. \u003cstrong data-start=\"13308\" data-end=\"13441\"\u003eInstead of constantly operating at full power, the device can modulate its output according to the actual needs of the room.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"13443\" data-end=\"13508\"\u003eIndoor unit installation: location changes everything\u003c\/h2\u003e\n\u003cp data-start=\"13510\" data-end=\"13770\"\u003eFor a wall-mounted heat pump like the \u003cstrong data-start=\"13547\" data-end=\"13560\"\u003eZE-12CB22\u003c\/strong\u003e, the location of the indoor unit is a determining factor. The device must be installed to distribute air efficiently, without blowing directly on occupants for long periods.\u003c\/p\u003e\n\u003cp data-start=\"13772\" data-end=\"14347\"\u003eWe pay special attention to available walls, windows, stairs, low ceilings, tall furniture, corridors, doors, and passage areas. In many Montreal homes, brick walls, plaster ceilings, or narrow divisions can complicate location choice. In houses in Laval, Longueuil, the South Shore, or the North Shore, the layout is often different, but the same principles apply: \u003cstrong data-start=\"14258\" data-end=\"14347\"\u003ethe unit must be placed for comfort, not just to facilitate piping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"14349\" data-end=\"14661\"\u003eThe indoor unit dimensions are \u003cstrong data-start=\"14394\" data-end=\"14427\"\u003e33 7\/16 × 11 9\/16 × 8 1\/16 inches\u003c\/strong\u003e. This relatively compact size allows integration into several rooms, but necessary clearances must still be planned for maintenance, panel opening, filter cleaning, and air circulation.\u003c\/p\u003e\n\u003ch2 data-start=\"14663\" data-end=\"14739\"\u003eOutdoor unit installation: clearance, noise, and Quebec winter\u003c\/h2\u003e\n\u003cp data-start=\"14741\" data-end=\"14989\"\u003eThe outdoor unit of the \u003cstrong data-start=\"14766\" data-end=\"14779\"\u003eZE-12CB22\u003c\/strong\u003e measures \u003cstrong data-start=\"14787\" data-end=\"14817\"\u003e28 1\/8 × 21 1\/4 × 9 1\/2 inches\u003c\/strong\u003e. It is relatively compact, which can facilitate installation in tight spaces. However, compact does not mean it can be installed just anywhere.\u003c\/p\u003e\n\u003cp data-start=\"14991\" data-end=\"15291\"\u003eThe outdoor unit must have enough clearance to breathe properly. It should be installed on a stable base, protected as much as possible against excessive snow accumulation, ice falls, roof water, and obstacles that could block air exchange.\u003c\/p\u003e\n\u003cp data-start=\"15293\" data-end=\"15693\"\u003eThe indicated outdoor sound pressure level is \u003cstrong data-start=\"15343\" data-end=\"15355\"\u003e53 dB(A)\u003c\/strong\u003e. This is a reasonable level, but location remains important, especially in dense areas of Montreal, Longueuil, or Laval, where neighbors can be close. On the South Shore and North Shore, we also see installations where wind, snow, or natural terrain drainage can affect winter performance.\u003c\/p\u003e\n\u003cp data-start=\"15695\" data-end=\"15905\"\u003eA good installation must therefore take the cold season into account from the start. \u003cstrong data-start=\"15776\" data-end=\"15905\"\u003eA poorly positioned outdoor unit can lose efficiency, accumulate ice, or become harder to maintain.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"15907\" data-end=\"15955\"\u003e1\/4 - 3\/8 inch piping: an essential detail\u003c\/h2\u003e\n\u003cp data-start=\"15957\" data-end=\"16147\"\u003eThe \u003cstrong data-start=\"15967\" data-end=\"15980\"\u003eZE-12CB22\u003c\/strong\u003e model uses \u003cstrong data-start=\"16004\" data-end=\"16030\"\u003e1\/4 inch liquid piping\u003c\/strong\u003e and \u003cstrong data-start=\"16034\" data-end=\"16056\"\u003e3\/8 inch gas piping\u003c\/strong\u003e. This information is essential, especially when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"16149\" data-end=\"16533\"\u003eYou should never assume that old refrigerant lines are compatible. Incorrect pipe sizing can harm performance, reliability, and warranty. During a replacement, we check the diameter, line condition, total length, type of refrigerant previously used, accessibility, and the possibility of properly replacing the route.\u003c\/p\u003e\n\u003cp data-start=\"16535\" data-end=\"16832\"\u003eThe sheet indicates a piping length of \u003cstrong data-start=\"16582\" data-end=\"16599\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"16631\" data-end=\"16643\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"16676\" data-end=\"16688\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected. An installation that is too long, poorly calculated, or poorly prepared can affect the actual performance of the device.\u003c\/p\u003e\n\u003cp data-start=\"16834\" data-end=\"17051\"\u003eAt AirGreen, we prefer to recommend line replacements when it is the best technical option. This may sometimes add a bit of work, but it protects the client’s investment in the long term.\u003c\/p\u003e\n\u003ch2 data-start=\"17053\" data-end=\"17125\"\u003e208V \/ 230V electrical supply: to be verified before installation\u003c\/h2\u003e\n\u003cp data-start=\"17127\" data-end=\"17334\"\u003eThe \u003cstrong data-start=\"17130\" data-end=\"17143\"\u003eZE-12CB22\u003c\/strong\u003e operates at \u003cstrong data-start=\"17158\" data-end=\"17189\"\u003e208V \/ 230V, 60 Hz, single phase\u003c\/strong\u003e. The technical sheet indicates a \u003cstrong data-start=\"17221\" data-end=\"17266\"\u003enominal current of 5.2 A in cooling\u003c\/strong\u003e, \u003cstrong data-start=\"17268\" data-end=\"17290\"\u003e4.8 A in heating\u003c\/strong\u003e, a \u003cstrong data-start=\"17295\" data-end=\"17311\"\u003eMCA of 9.5 A\u003c\/strong\u003e, and a \u003cstrong data-start=\"17318\" data-end=\"17333\"\u003eMOP of 15 A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17336\" data-end=\"17608\"\u003eThese values are important for the electrician and the HVAC installer. Before confirming the installation, the electrical panel, available space, breaker type, wire gauge, wiring route, and installation compliance must be checked.\u003c\/p\u003e\n\u003cp data-start=\"17610\" data-end=\"17880\"\u003eIn some older homes, especially in Montreal or Longueuil, the panel may already be fully loaded. In other cases, panel access is easy and the electrical installation poses no particular problems. Each project must be evaluated on site.\u003c\/p\u003e\n\u003cp data-start=\"17882\" data-end=\"18102\"\u003e\u003cstrong data-start=\"17882\" data-end=\"17950\"\u003eA high-performance device must always be properly powered.\u003c\/strong\u003e Poor electrical supply can cause operational issues, protection trips, or non-compliant installation.\u003c\/p\u003e\n\u003ch2 data-start=\"18104\" data-end=\"18139\"\u003ePractical daily functions\u003c\/h2\u003e\n\u003cp data-start=\"18141\" data-end=\"18244\"\u003eThe brochure mentions several features that make using the \u003cstrong data-start=\"18215\" data-end=\"18228\"\u003eZE-12CB22\u003c\/strong\u003e more enjoyable:\u003c\/p\u003e\n\u003cp data-start=\"18246\" data-end=\"18598\"\u003e• \u003cstrong data-start=\"18248\" data-end=\"18277\"\u003eLED wireless remote control\u003c\/strong\u003e;\u003cbr data-start=\"18278\" data-end=\"18281\"\u003e• \u003cstrong data-start=\"18283\" data-end=\"18302\"\u003eLED dimmer\u003c\/strong\u003e;\u003cbr data-start=\"18303\" data-end=\"18306\"\u003e• \u003cstrong data-start=\"18308\" data-end=\"18348\"\u003e5 indoor fan speeds\u003c\/strong\u003e;\u003cbr data-start=\"18349\" data-end=\"18352\"\u003e• \u003cstrong data-start=\"18354\" data-end=\"18372\"\u003eTurbo function\u003c\/strong\u003e;\u003cbr data-start=\"18373\" data-end=\"18376\"\u003e• \u003cstrong data-start=\"18378\" data-end=\"18403\"\u003eautomatic defrost\u003c\/strong\u003e;\u003cbr data-start=\"18404\" data-end=\"18407\"\u003e• \u003cstrong data-start=\"18409\" data-end=\"18434\"\u003eautomatic cleaning\u003c\/strong\u003e;\u003cbr data-start=\"18435\" data-end=\"18438\"\u003e• \u003cstrong data-start=\"18440\" data-end=\"18476\"\u003ediffuser position memory\u003c\/strong\u003e;\u003cbr data-start=\"18477\" data-end=\"18480\"\u003e• \u003cstrong data-start=\"18482\" data-end=\"18512\"\u003e8 °C automatic heating\u003c\/strong\u003e;\u003cbr data-start=\"18513\" data-end=\"18516\"\u003e• \u003cstrong data-start=\"18518\" data-end=\"18546\"\u003ereversible drain pipe\u003c\/strong\u003e;\u003cbr data-start=\"18547\" data-end=\"18550\"\u003e• \u003cstrong data-start=\"18552\" data-end=\"18597\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18600\" data-end=\"19026\"\u003eThe \u003cstrong data-start=\"18603\" data-end=\"18621\"\u003eTurbo function\u003c\/strong\u003e can help reach the desired temperature faster. The \u003cstrong data-start=\"18690\" data-end=\"18715\"\u003eautomatic defrost\u003c\/strong\u003e is essential for winter operation. The \u003cstrong data-start=\"18766\" data-end=\"18791\"\u003eautomatic cleaning\u003c\/strong\u003e helps keep the indoor unit cleaner, although it does not replace regular maintenance. The \u003cstrong data-start=\"18897\" data-end=\"18927\"\u003e8 °C automatic heating\u003c\/strong\u003e can be useful in some rarely used spaces where you want to avoid too low a temperature.\u003c\/p\u003e\n\u003cp data-start=\"19028\" data-end=\"19318\"\u003eThe \u003cstrong data-start=\"19031\" data-end=\"19059\"\u003ereversible drain pipe\u003c\/strong\u003e and the \u003cstrong data-start=\"19066\" data-end=\"19088\"\u003etwo-sided drain\u003c\/strong\u003e also facilitate installation in different configurations. This type of detail may seem minor, but on a real job site, it can make a big difference in achieving a clean, discreet, and durable installation.\u003c\/p\u003e\n\u003ch2 data-start=\"19320\" data-end=\"19382\"\u003eHVAC Maintenance: preserving performance year after year\u003c\/h2\u003e\n\u003cp data-start=\"19384\" data-end=\"19592\"\u003eA well-installed wall-mounted heat pump must also be well maintained. To preserve performance, airflow, noise level, and operational quality, we recommend regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"19594\" data-end=\"19978\"\u003eThe owner should frequently clean the filters, monitor for unusual noises, check that the indoor unit is blowing properly, and ensure the outdoor unit remains clear. In winter, snow, ice, or debris must not block the device. In summer, leaves, dust, and outdoor residues can also affect performance.\u003c\/p\u003e\n\u003cp data-start=\"19980\" data-end=\"20280\"\u003eProfessional maintenance may be necessary when the device loses performance, emits an odor, leaks, makes more noise than before, or seems to run longer than usual. \u003cstrong data-start=\"20174\" data-end=\"20280\"\u003eProper maintenance extends the system’s lifespan and helps maintain more stable consumption.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"20282\" data-end=\"20525\"\u003eEven if the brochure mentions \u003cstrong data-start=\"20315\" data-end=\"20340\"\u003eautomatic cleaning\u003c\/strong\u003e, this function does not replace a thorough cleaning when the unit is dirty. It helps daily, but it should not be seen as a permanent solution without maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"20527\" data-end=\"20589\"\u003eMistakes to avoid before buying a 12,000 BTU heat pump\u003c\/h2\u003e\n\u003cp data-start=\"20591\" data-end=\"20753\"\u003eIn our experience, the most common mistakes do not always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"20755\" data-end=\"20783\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"20785\" data-end=\"21429\"\u003e• \u003cstrong data-start=\"20787\" data-end=\"20848\"\u003echoosing a 12,000 BTU unit without analyzing the actual area\u003c\/strong\u003e;\u003cbr data-start=\"20849\" data-end=\"20852\"\u003e• \u003cstrong data-start=\"20854\" data-end=\"20904\"\u003eneglecting insulation and sun exposure\u003c\/strong\u003e;\u003cbr data-start=\"20905\" data-end=\"20908\"\u003e• \u003cstrong data-start=\"20910\" data-end=\"20983\"\u003einstalling the indoor unit in a convenient but ineffective location\u003c\/strong\u003e;\u003cbr data-start=\"20984\" data-end=\"20987\"\u003e• \u003cstrong data-start=\"20989\" data-end=\"21038\"\u003eforgetting to check the electrical supply\u003c\/strong\u003e;\u003cbr data-start=\"21039\" data-end=\"21042\"\u003e• \u003cstrong data-start=\"21044\" data-end=\"21112\"\u003eassuming that old refrigerant lines are compatible\u003c\/strong\u003e;\u003cbr data-start=\"21113\" data-end=\"21116\"\u003e• \u003cstrong data-start=\"21118\" data-end=\"21183\"\u003eplacing the outdoor unit too close to a wall or fence\u003c\/strong\u003e;\u003cbr data-start=\"21184\" data-end=\"21187\"\u003e• \u003cstrong data-start=\"21189\" data-end=\"21229\"\u003eneglecting the impact of outdoor noise\u003c\/strong\u003e;\u003cbr data-start=\"21230\" data-end=\"21233\"\u003e• \u003cstrong data-start=\"21235\" data-end=\"21264\"\u003eignoring future maintenance\u003c\/strong\u003e;\u003cbr data-start=\"21265\" data-end=\"21268\"\u003e• \u003cstrong data-start=\"21270\" data-end=\"21343\"\u003emisunderstanding the actual low-temperature heating capacities\u003c\/strong\u003e;\u003cbr data-start=\"21344\" data-end=\"21347\"\u003e• \u003cstrong data-start=\"21349\" data-end=\"21428\"\u003ebuying solely based on price without checking installation quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"21431\" data-end=\"21660\"\u003eAt AirGreen, our role is to prevent these mistakes before the work begins. We want the client to understand why a model is recommended, how it will be installed, and what it can actually offer in their building.\u003c\/p\u003e\n\u003ch2 data-start=\"21662\" data-end=\"21725\"\u003eWhy choose AirGreen to install the Zephyr ZE-12CB22\u003c\/h2\u003e\n\u003cp data-start=\"21727\" data-end=\"21984\"\u003eAirGreen is a company specializing in \u003cstrong data-start=\"21770\" data-end=\"21778\"\u003eHVAC\u003c\/strong\u003e, active in Montreal, Laval, Longueuil, on the South Shore and the North Shore. We install, replace, maintain, and repair wall-mounted, central, and multi-zone heat pumps in a wide variety of settings.\u003c\/p\u003e\n\u003cp data-start=\"21986\" data-end=\"22231\"\u003eFor a model like the \u003cstrong data-start=\"22010\" data-end=\"22039\"\u003eZephyr CB22 R32 ZE-12CB22\u003c\/strong\u003e, our approach is simple: we first verify if the unit truly meets the need. Then, we plan the installation so the result is clean, efficient, and durable.\u003c\/p\u003e\n\u003cp data-start=\"22233\" data-end=\"22283\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"22285\" data-end=\"22778\"\u003e• \u003cstrong data-start=\"22287\" data-end=\"22332\"\u003ea clear evaluation before work begins\u003c\/strong\u003e;\u003cbr data-start=\"22333\" data-end=\"22336\"\u003e• \u003cstrong data-start=\"22338\" data-end=\"22386\"\u003ea recommendation tailored to their building\u003c\/strong\u003e;\u003cbr data-start=\"22387\" data-end=\"22390\"\u003e• \u003cstrong data-start=\"22392\" data-end=\"22449\"\u003ean installation compliant with HVAC best practices\u003c\/strong\u003e;\u003cbr data-start=\"22450\" data-end=\"22453\"\u003e• \u003cstrong data-start=\"22455\" data-end=\"22523\"\u003ea thorough check of electrical and piping systems\u003c\/strong\u003e;\u003cbr data-start=\"22524\" data-end=\"22527\"\u003e• \u003cstrong data-start=\"22529\" data-end=\"22584\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"22585\" data-end=\"22588\"\u003e• \u003cstrong data-start=\"22590\" data-end=\"22628\"\u003ea structured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"22629\" data-end=\"22632\"\u003e• \u003cstrong data-start=\"22634\" data-end=\"22690\"\u003ea team familiar with the realities of Greater Montreal\u003c\/strong\u003e;\u003cbr data-start=\"22691\" data-end=\"22694\"\u003e• \u003cstrong data-start=\"22696\" data-end=\"22777\"\u003esupport to understand warranties, options, and maintenance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"22780\" data-end=\"23250\"\u003eThe \u003cstrong data-start=\"22783\" data-end=\"22822\"\u003eZephyr ZE-12CB22 wall-mounted heat pump\u003c\/strong\u003e is an interesting option for homeowners seeking an efficient, compact comfort solution well suited to a specific area. With its \u003cstrong data-start=\"22985\" data-end=\"23004\"\u003eR32 refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"23010\" data-end=\"23025\"\u003eSEER2 of 20\u003c\/strong\u003e, \u003cstrong data-start=\"23031\" data-end=\"23045\"\u003eHSPF2 of 9\u003c\/strong\u003e, heating operation down to \u003cstrong data-start=\"23087\" data-end=\"23097\"\u003e-25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"23103\" data-end=\"23119\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"23125\" data-end=\"23136\"\u003e4D mode\u003c\/strong\u003e, and a \u003cstrong data-start=\"23155\" data-end=\"23172\"\u003e10-year parts warranty\u003c\/strong\u003e, it can meet many residential and light commercial needs.\u003c\/p\u003e\n\u003cp data-start=\"23252\" data-end=\"23484\"\u003eHowever, it requires careful installation. The right location, proper piping, correct electrical supply, adherence to clearances, and full startup are essential to achieve a reliable result.\u003c\/p\u003e\n\u003cp data-start=\"23486\" data-end=\"23817\"\u003eTo get a clear quote, compare the \u003cstrong data-start=\"23534\" data-end=\"23547\"\u003eZE-12CB22\u003c\/strong\u003e with other Zephyr models, or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the HVAC solution best suited to your space, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925620004,"sku":"ZE-12CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_c7c2d7ee-15cc-42a8-99fc-a7d0666cbde9.png?v=1783356997","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-cb22-r32-12000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}