{"product_id":"thermopompe-murale-zephyr-cb22-r32-18000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 18000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"118\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"118\"\u003eZephyr ZE-18CB22 Wall-Mounted Heat Pump — 18,000 BTU, R32, winter comfort down to -25 °C, and Energy Star efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"120\" data-end=\"593\"\u003eThe \u003cstrong data-start=\"123\" data-end=\"162\"\u003eZephyr ZE-18CB22 Wall-Mounted Heat Pump\u003c\/strong\u003e is an HVAC solution designed for homeowners seeking a reliable, efficient wall unit well suited to Quebec’s climate conditions. With a capacity of \u003cstrong data-start=\"341\" data-end=\"372\"\u003e18,000 BTU for cooling\u003c\/strong\u003e and \u003cstrong data-start=\"379\" data-end=\"415\"\u003e18,000 BTU for heating at 8.3 °C\u003c\/strong\u003e, this model targets spaces that require more than a small standard wall unit, without necessarily moving to a very high-capacity machine like a 24,000 BTU.\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"1128\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the customer wants to cool and heat a large living area, an open living room, a spacious condo, an office, a finished basement, or a residential area where temperature stability is important. The \u003cstrong data-start=\"883\" data-end=\"903\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e positions itself as a balanced device: powerful enough to provide a good comfort reserve, yet still suitable for many residential configurations in Montreal, Laval, Longueuil, on the South Shore, and the North Shore.\u003c\/p\u003e\n\u003cp data-start=\"1130\" data-end=\"1799\"\u003eThis model is part of the \u003cstrong data-start=\"1164\" data-end=\"1183\"\u003eZephyr CB22 R32\u003c\/strong\u003e series, a range of wall-mounted heat pumps designed to offer \u003cstrong data-start=\"1241\" data-end=\"1272\"\u003eaffordable winter comfort\u003c\/strong\u003e, with heating operation down to \u003cstrong data-start=\"1318\" data-end=\"1328\"\u003e-25 °C\u003c\/strong\u003e and air conditioning mode down to \u003cstrong data-start=\"1362\" data-end=\"1372\"\u003e-15 °C\u003c\/strong\u003e. The brochure also highlights several practical features such as \u003cstrong data-start=\"1448\" data-end=\"1461\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1466\" data-end=\"1482\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1487\" data-end=\"1501\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1506\" data-end=\"1526\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"1531\" data-end=\"1552\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"1557\" data-end=\"1585\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"1590\" data-end=\"1632\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e, \u003cstrong data-start=\"1637\" data-end=\"1659\"\u003etwo-sided drain\u003c\/strong\u003e, \u003cstrong data-start=\"1664\" data-end=\"1682\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"1687\" data-end=\"1698\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"1703\" data-end=\"1728\"\u003eautomatic cleaning\u003c\/strong\u003e, and \u003cstrong data-start=\"1735\" data-end=\"1760\"\u003eautomatic defrosting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"1801\" data-end=\"1884\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1804\" data-end=\"1884\"\u003eAn 18,000 BTU wall-mounted heat pump designed for adequately sized spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1886\" data-end=\"2281\"\u003eThe \u003cstrong data-start=\"1889\" data-end=\"1909\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e offers a cooling capacity of \u003cstrong data-start=\"1951\" data-end=\"1967\"\u003e18,000 BTU\/h\u003c\/strong\u003e at 35 °C. This power allows it to handle spaces larger than a simple bedroom or small office. It can be suitable for an open area, a partially open ground floor, a living room with dining area, a larger condo, or a living zone where heat accumulates quickly in summer.\u003c\/p\u003e\n\u003cp data-start=\"2283\" data-end=\"2670\"\u003eHowever, at AirGreen, we always remind that a heat pump should never be chosen solely based on the number of BTUs. An \u003cstrong data-start=\"2429\" data-end=\"2443\"\u003e18,000 BTU\u003c\/strong\u003e unit can deliver excellent results in a well-configured space, but it can also be poorly suited if the room is too closed off, if air circulation is poor, or if the indoor unit’s location does not allow good distribution.\u003c\/p\u003e\n\u003cp data-start=\"2672\" data-end=\"3095\"\u003eBefore confirming the installation of a wall-mounted heat pump like the \u003cstrong data-start=\"2740\" data-end=\"2753\"\u003eZE-18CB22\u003c\/strong\u003e, we assess several factors: \u003cstrong data-start=\"2790\" data-end=\"3094\"\u003ethe actual area to be treated, insulation, ceiling height, window orientation, solar load, openings between rooms, positioning of the indoor unit, location of the outdoor unit, piping route, drainage, and available electrical capacity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3097\" data-end=\"3411\"\u003eA device that performs well on paper can deliver average results if it is poorly sized or installed. Conversely, a well-selected, well-positioned, and well-configured heat pump can transform the comfort of a space that was previously too hot in summer, too cold in winter, or difficult to balance.\u003c\/p\u003e\n\u003ch2 data-start=\"3413\" data-end=\"3486\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3416\" data-end=\"3486\"\u003eKey technical features of the Zephyr ZE-18CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3488\" data-end=\"3568\"\u003eFor this \u003cstrong data-start=\"3503\" data-end=\"3517\"\u003e18,000 BTU\u003c\/strong\u003e model, the main information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"3570\" data-end=\"5415\"\u003e• \u003cstrong data-start=\"3572\" data-end=\"3591\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3591\" data-end=\"3594\"\u003e• \u003cstrong data-start=\"3596\" data-end=\"3612\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"3612\" data-end=\"3615\"\u003e• \u003cstrong data-start=\"3617\" data-end=\"3639\"\u003eModel: ZE-18CB22\u003c\/strong\u003e\u003cbr data-start=\"3639\" data-end=\"3642\"\u003e• \u003cstrong data-start=\"3644\" data-end=\"3673\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"3673\" data-end=\"3676\"\u003e• \u003cstrong data-start=\"3678\" data-end=\"3699\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"3699\" data-end=\"3702\"\u003e• \u003cstrong data-start=\"3704\" data-end=\"3758\"\u003eCooling capacity at 35 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3758\" data-end=\"3761\"\u003e• \u003cstrong data-start=\"3763\" data-end=\"3812\"\u003eHeating capacity at 8.3 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3812\" data-end=\"3815\"\u003e• \u003cstrong data-start=\"3817\" data-end=\"3831\"\u003eSEER2: 20\u003c\/strong\u003e\u003cbr data-start=\"3831\" data-end=\"3834\"\u003e• \u003cstrong data-start=\"3836\" data-end=\"3851\"\u003eHSPF2: 9.8\u003c\/strong\u003e\u003cbr data-start=\"3851\" data-end=\"3854\"\u003e• \u003cstrong data-start=\"3856\" data-end=\"3878\"\u003eEER2: 11.95 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"3878\" data-end=\"3881\"\u003e• \u003cstrong data-start=\"3883\" data-end=\"3918\"\u003eHeating COP at 8.3 °C: 3.9\u003c\/strong\u003e\u003cbr data-start=\"3918\" data-end=\"3921\"\u003e• \u003cstrong data-start=\"3923\" data-end=\"3957\"\u003eHeating COP2: 13.3 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"3957\" data-end=\"3960\"\u003e• \u003cstrong data-start=\"3962\" data-end=\"4021\"\u003eNominal heating capacity at -8.3 °C: 14,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4021\" data-end=\"4024\"\u003e• \u003cstrong data-start=\"4026\" data-end=\"4084\"\u003eMaximum heating capacity at -15 °C: 13,400 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4084\" data-end=\"4087\"\u003e• \u003cstrong data-start=\"4089\" data-end=\"4111\"\u003eCOP at -15 °C: 2.4\u003c\/strong\u003e\u003cbr data-start=\"4111\" data-end=\"4114\"\u003e• \u003cstrong data-start=\"4116\" data-end=\"4174\"\u003eMaximum heating capacity at -20 °C: 10,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4174\" data-end=\"4177\"\u003e• \u003cstrong data-start=\"4179\" data-end=\"4205\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"4205\" data-end=\"4208\"\u003e• \u003cstrong data-start=\"4210\" data-end=\"4241\"\u003eAirflow: 466 to 647 CFM\u003c\/strong\u003e\u003cbr data-start=\"4241\" data-end=\"4244\"\u003e• \u003cstrong data-start=\"4246\" data-end=\"4282\"\u003eRefrigerant charge: 45.86 oz\u003c\/strong\u003e\u003cbr data-start=\"4282\" data-end=\"4285\"\u003e• \u003cstrong data-start=\"4287\" data-end=\"4352\"\u003eIndoor sound pressure: 49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4352\" data-end=\"4355\"\u003e• \u003cstrong data-start=\"4357\" data-end=\"4402\"\u003eOutdoor sound pressure: 56 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4402\" data-end=\"4405\"\u003e• \u003cstrong data-start=\"4407\" data-end=\"4446\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"4446\" data-end=\"4449\"\u003e• \u003cstrong data-start=\"4451\" data-end=\"4495\"\u003eNominal cooling current: 6.4 A\u003c\/strong\u003e\u003cbr data-start=\"4495\" data-end=\"4498\"\u003e• \u003cstrong data-start=\"4500\" data-end=\"4540\"\u003eNominal heating current: 8.1 A\u003c\/strong\u003e\u003cbr data-start=\"4540\" data-end=\"4543\"\u003e• \u003cstrong data-start=\"4545\" data-end=\"4561\"\u003eMCA: 14.5 A\u003c\/strong\u003e\u003cbr data-start=\"4561\" data-end=\"4564\"\u003e• \u003cstrong data-start=\"4566\" data-end=\"4580\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"4580\" data-end=\"4583\"\u003e• \u003cstrong data-start=\"4585\" data-end=\"4649\"\u003eCommunication wire required: 4\/14 copper multi-strand 600 V\u003c\/strong\u003e\u003cbr data-start=\"4649\" data-end=\"4652\"\u003e• \u003cstrong data-start=\"4654\" data-end=\"4687\"\u003eCompressor type: rotary\u003c\/strong\u003e\u003cbr data-start=\"4687\" data-end=\"4690\"\u003e• \u003cstrong data-start=\"4692\" data-end=\"4727\"\u003eCompressor manufacturer: GMCC\u003c\/strong\u003e\u003cbr data-start=\"4727\" data-end=\"4730\"\u003e• \u003cstrong data-start=\"4732\" data-end=\"4775\"\u003eExpansion device: capillary tube\u003c\/strong\u003e\u003cbr data-start=\"4775\" data-end=\"4778\"\u003e• \u003cstrong data-start=\"4780\" data-end=\"4809\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4809\" data-end=\"4812\"\u003e• \u003cstrong data-start=\"4814\" data-end=\"4843\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4843\" data-end=\"4846\"\u003e• \u003cstrong data-start=\"4848\" data-end=\"4874\"\u003eLiquid pipe: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"4874\" data-end=\"4877\"\u003e• \u003cstrong data-start=\"4879\" data-end=\"4901\"\u003eGas pipe: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"4901\" data-end=\"4904\"\u003e• \u003cstrong data-start=\"4906\" data-end=\"4956\"\u003eMinimum-maximum piping length: 10 to 98 feet\u003c\/strong\u003e\u003cbr data-start=\"4956\" data-end=\"4959\"\u003e• \u003cstrong data-start=\"4961\" data-end=\"4998\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"4998\" data-end=\"5001\"\u003e• \u003cstrong data-start=\"5003\" data-end=\"5039\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"5039\" data-end=\"5042\"\u003e• \u003cstrong data-start=\"5044\" data-end=\"5111\"\u003eIndoor unit dimensions: 42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"5111\" data-end=\"5114\"\u003e• \u003cstrong data-start=\"5116\" data-end=\"5174\"\u003eOutdoor unit dimensions: 31 7\/8 × 23 × 11 in\u003c\/strong\u003e\u003cbr data-start=\"5174\" data-end=\"5177\"\u003e• \u003cstrong data-start=\"5179\" data-end=\"5240\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"5240\" data-end=\"5243\"\u003e• \u003cstrong data-start=\"5245\" data-end=\"5302\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"5302\" data-end=\"5305\"\u003e• \u003cstrong data-start=\"5307\" data-end=\"5343\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"5343\" data-end=\"5346\"\u003e• \u003cstrong data-start=\"5348\" data-end=\"5415\"\u003eLabor warranty: available depending on the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5417\" data-end=\"5840\"\u003eThis data is essential because it directly influences the choice of device, installation feasibility, and the system’s actual performance. For example, an \u003cstrong data-start=\"5612\" data-end=\"5626\"\u003e18,000 BTU\u003c\/strong\u003e heat pump with a \u003cstrong data-start=\"5652\" data-end=\"5665\"\u003e208\/230 V\u003c\/strong\u003e power supply, a \u003cstrong data-start=\"5670\" data-end=\"5685\"\u003e20 A MOP\u003c\/strong\u003e, and a \u003cstrong data-start=\"5692\" data-end=\"5709\"\u003e14.5 A MCA\u003c\/strong\u003e must be electrically validated before installation. This is not the same type of project as a small 115 V wall unit.\u003c\/p\u003e\n\u003ch2 data-start=\"5842\" data-end=\"5908\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5845\" data-end=\"5908\"\u003eWhy R32 is relevant for this wall-mounted heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5910\" data-end=\"6239\"\u003eThe \u003cstrong data-start=\"5913\" data-end=\"5933\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"5945\" data-end=\"5964\"\u003eR32 refrigerant\u003c\/strong\u003e, a gas widely used in new generations of wall-mounted heat pumps. For the customer, the refrigerant name may seem technical, but it is important because it is part of the overall device design and influences proper installation practices.\u003c\/p\u003e\n\u003cp data-start=\"6241\" data-end=\"6612\"\u003eThe \u003cstrong data-start=\"6244\" data-end=\"6251\"\u003eR32\u003c\/strong\u003e is paired with modern, efficient equipment well suited to current residential needs. That said, an R32 heat pump must be installed with precision. Connections must be clean, piping lengths must be respected, the leak test must be properly performed, and the vacuum pull must be done thoroughly.\u003c\/p\u003e\n\u003cp data-start=\"6614\" data-end=\"6937\"\u003eAt AirGreen, we emphasize this point: \u003cstrong data-start=\"6659\" data-end=\"6729\"\u003ea modern device does not tolerate a sloppy installation\u003c\/strong\u003e. Even a high-performance heat pump can lose efficiency, become noisy, or develop premature issues if the piping, electrical work, drainage, or clearances are not properly planned.\u003c\/p\u003e\n\u003ch2 data-start=\"6939\" data-end=\"7021\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6942\" data-end=\"7021\"\u003eBalanced energy efficiency for heating and cooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7023\" data-end=\"7264\"\u003eThe technical sheet for the \u003cstrong data-start=\"7048\" data-end=\"7068\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e indicates a \u003cstrong data-start=\"7080\" data-end=\"7095\"\u003eSEER2 of 20\u003c\/strong\u003e for cooling and an \u003cstrong data-start=\"7121\" data-end=\"7137\"\u003eHSPF2 of 9.8\u003c\/strong\u003e for heating. These two figures are important for evaluating the unit’s energy performance over a full season.\u003c\/p\u003e\n\u003cp data-start=\"7266\" data-end=\"7550\"\u003eThe \u003cstrong data-start=\"7269\" data-end=\"7278\"\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. The higher it is, the more the unit is designed to cool efficiently using less energy. In the case of the ZE-18CB22, the \u003cstrong data-start=\"7465\" data-end=\"7480\"\u003eSEER2 of 20\u003c\/strong\u003e represents good performance for a wall-mounted unit of this capacity.\u003c\/p\u003e\n\u003cp data-start=\"7552\" data-end=\"7936\"\u003eThe \u003cstrong data-start=\"7555\" data-end=\"7571\"\u003eHSPF2 of 9.8\u003c\/strong\u003e provides an indication of heating efficiency. In Quebec, this figure is especially important because a heat pump is not used just a few weeks a year. It can contribute to comfort during fall, winter, and spring by reducing the use of traditional electric heating when conditions allow.\u003c\/p\u003e\n\u003cp data-start=\"7938\" data-end=\"8268\"\u003eThe \u003cstrong data-start=\"7941\" data-end=\"7964\"\u003eCOP of 3.9 at 8.3 °C\u003c\/strong\u003e means the unit can produce multiple units of heat for each unit of electricity consumed under favorable conditions. Even at \u003cstrong data-start=\"8112\" data-end=\"8122\"\u003e-15 °C\u003c\/strong\u003e, the sheet indicates a \u003cstrong data-start=\"8144\" data-end=\"8158\"\u003eCOP of 2.4\u003c\/strong\u003e, showing that the unit maintains good efficiency as the outdoor temperature drops.\u003c\/p\u003e\n\u003ch2 data-start=\"8270\" data-end=\"8335\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8273\" data-end=\"8335\"\u003eHeating down to -25 °C: what this really means\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8337\" data-end=\"8655\"\u003eThe Zephyr CB22 brochure states that this series can operate in heating mode down to \u003cstrong data-start=\"8423\" data-end=\"8433\"\u003e-25 °C\u003c\/strong\u003e. For homeowners in Montreal, Laval, Longueuil, the South Shore, and the North Shore, this is an important point, as Quebec winters require a unit capable of functioning well below mild temperatures.\u003c\/p\u003e\n\u003cp data-start=\"8657\" data-end=\"9005\"\u003eIt is important to understand that the heating capacity of a heat pump naturally decreases as the outdoor temperature drops. For the \u003cstrong data-start=\"8805\" data-end=\"8818\"\u003eZE-18CB22\u003c\/strong\u003e, the technical sheet indicates a nominal capacity of \u003cstrong data-start=\"8872\" data-end=\"8898\"\u003e14,800 BTU\/h at -8.3 °C\u003c\/strong\u003e, a maximum capacity of \u003cstrong data-start=\"8925\" data-end=\"8950\"\u003e13,400 BTU\/h at -15 °C\u003c\/strong\u003e, and a maximum capacity of \u003cstrong data-start=\"8979\" data-end=\"9004\"\u003e10,000 BTU\/h at -20 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"9007\" data-end=\"9391\"\u003eThese figures are very useful for evaluating real winter performance. In a well-insulated house, this capacity can cover a large part of the heating needs of the served area. In an older house, with many windows, exposed to wind, or with significant heat loss, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"9393\" data-end=\"9730\"\u003eAt AirGreen, we prefer to explain this reality from the start. A high-performance wall-mounted heat pump can significantly reduce traditional heating consumption, but it must be intelligently integrated into the building. \u003cstrong data-start=\"9620\" data-end=\"9730\"\u003eThe right result always comes from the right choice of device, the right location, and proper installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"9732\" data-end=\"9826\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9735\" data-end=\"9826\"\u003eIndoor comfort: 4D mode, automatic oscillation, and better air distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9828\" data-end=\"10066\"\u003eThe \u003cstrong data-start=\"9831\" data-end=\"9851\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e focuses on air distribution. The brochure presents \u003cstrong data-start=\"9919\" data-end=\"9930\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9936\" data-end=\"9963\"\u003eautomatic oscillation\u003c\/strong\u003e, two features designed to better distribute air in the room and reduce cold or hot spots.\u003c\/p\u003e\n\u003cp data-start=\"10068\" data-end=\"10454\"\u003eIn an open area, air distribution is a key factor. A heat pump may have good capacity, but if the air is blown in the wrong direction or blocked by a beam, wall, tall furniture, or interior partition, comfort can be uneven. The \u003cstrong data-start=\"10352\" data-end=\"10363\"\u003e4D mode\u003c\/strong\u003e helps improve diffusion, but it does not replace a proper location analysis.\u003c\/p\u003e\n\u003cp data-start=\"10456\" data-end=\"10876\"\u003eAt AirGreen, we pay special attention to the positioning of the indoor unit. We avoid placing the device so that it blows directly on occupants for long periods whenever possible. Instead, we look for a location that allows good air circulation in the main area while respecting the building’s aesthetics and the feasibility of piping installation.\u003c\/p\u003e\n\u003ch2 data-start=\"10878\" data-end=\"10960\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10881\" data-end=\"10960\"\u003eiFeel mode, silent mode, and night mode: more precise comfort every day\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10962\" data-end=\"11312\"\u003eThe \u003cstrong data-start=\"10965\" data-end=\"10978\"\u003eZE-18CB22\u003c\/strong\u003e offers several comfort features that make daily use more enjoyable. The \u003cstrong data-start=\"11072\" data-end=\"11086\"\u003eiFeel mode\u003c\/strong\u003e allows adjustment based on the temperature sensed near the remote control, which can be useful when the temperature near the indoor unit is not exactly the same as in the occupied area.\u003c\/p\u003e\n\u003cp data-start=\"11314\" data-end=\"11716\"\u003eThe \u003cstrong data-start=\"11317\" data-end=\"11333\"\u003esilent mode\u003c\/strong\u003e is particularly useful for living rooms, bedrooms, offices, or workspaces. The indoor sound pressure of this model drops to \u003cstrong data-start=\"11488\" data-end=\"11516\"\u003e33 dB(A) in silent mode\u003c\/strong\u003e, allowing discreet operation when conditions are favorable. The noise level varies according to fan speed, with values indicated at \u003cstrong data-start=\"11683\" data-end=\"11715\"\u003e49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11718\" data-end=\"12021\"\u003eThe \u003cstrong data-start=\"11721\" data-end=\"11734\"\u003enight mode\u003c\/strong\u003e helps maintain gentler comfort during sleeping hours. The \u003cstrong data-start=\"11807\" data-end=\"11825\"\u003e24-hour timer\u003c\/strong\u003e also allows programming the device according to occupants' habits, for example to reduce use when the house is empty or to prepare comfort before returning home.\u003c\/p\u003e\n\u003ch2 data-start=\"12023\" data-end=\"12117\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12026\" data-end=\"12117\"\u003eVariable frequency technology: stability and reduction of temperature fluctuations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12119\" data-end=\"12389\"\u003eThe brochure explains that variable frequency technology allows the heat pump to adjust its power in real time. This approach is important because it avoids abrupt temperature changes and allows for more gradual use of the device.\u003c\/p\u003e\n\u003cp data-start=\"12391\" data-end=\"12791\"\u003eA traditional on-off system often works in more pronounced cycles: it starts, blows strongly, reaches the temperature, then stops. A variable technology heat pump can instead modulate its power to maintain more stable comfort. This helps reduce hot-cold sensations, improves overall comfort, and can contribute to better energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"12793\" data-end=\"13153\"\u003eFor a customer, this difference is mostly felt daily. The temperature seems more consistent, the device operates more smoothly, and the room becomes more comfortable to live in. In a house in Montreal or Longueuil with interior partitions, or in a condo in Laval with an open floor plan, this stability can make a real difference.\u003c\/p\u003e\n\u003ch2 data-start=\"13155\" data-end=\"13216\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13158\" data-end=\"13216\"\u003eHVAC Installation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13218\" data-end=\"13442\"\u003eInstalling a wall-mounted heat pump is not just about mounting the indoor unit on the wall. For a model like the \u003cstrong data-start=\"13333\" data-end=\"13353\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e, several technical decisions directly affect performance and durability.\u003c\/p\u003e\n\u003cp data-start=\"13444\" data-end=\"13735\"\u003eThe indoor unit measures \u003cstrong data-start=\"13470\" data-end=\"13502\"\u003e42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e. This dimension must be considered before installation, especially in spaces with limited clear heights, narrow walls, or when there are moldings, curtains, cabinets, beams, or sloped ceilings.\u003c\/p\u003e\n\u003cp data-start=\"13737\" data-end=\"14139\"\u003eThe outdoor unit measures \u003cstrong data-start=\"13763\" data-end=\"13786\"\u003e31 7\/8 × 23 × 11 inches\u003c\/strong\u003e. It must be installed in a stable, well-cleared location, accessible for maintenance, and protected as much as possible against excessive accumulations of snow, ice, or water from the roof. In Quebec, this detail is very important. A poorly placed outdoor unit can operate more difficultly in winter and require more maintenance.\u003c\/p\u003e\n\u003cp data-start=\"14141\" data-end=\"14439\"\u003eAt AirGreen, we always analyze the route between the indoor and outdoor units. We look for a clean, efficient, and durable piping path, taking into account exterior aesthetics, drain slope, building structure, and future service access.\u003c\/p\u003e\n\u003ch2 data-start=\"14441\" data-end=\"14517\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14444\" data-end=\"14517\"\u003e1\/4 - 1\/2 inch Piping: A Point to Check Before Any Replacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14519\" data-end=\"14693\"\u003eThe \u003cstrong data-start=\"14522\" data-end=\"14535\"\u003eZE-18CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"14562\" data-end=\"14588\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"14592\" data-end=\"14614\"\u003e1\/2 inch gas\u003c\/strong\u003e piping. This information is crucial when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"14695\" data-end=\"15060\"\u003eMany customers want to reuse existing lines to reduce work. Sometimes, this is possible. But it should never be assumed without verification. The diameter of the lines, their condition, cleanliness, length, the old refrigerant used, accessibility, and the possibility of properly connecting them to the new system must be confirmed.\u003c\/p\u003e\n\u003cp data-start=\"15062\" data-end=\"15419\"\u003eThe datasheet indicates a piping length of \u003cstrong data-start=\"15109\" data-end=\"15126\"\u003e10 to 98 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"15158\" data-end=\"15170\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"15203\" data-end=\"15215\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected to ensure proper operation of the unit. Piping that is too long, poorly insulated, improperly installed, or incompatible can impair performance and reliability.\u003c\/p\u003e\n\u003ch2 data-start=\"15421\" data-end=\"15490\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15424\" data-end=\"15490\"\u003e208\/230 V Power Supply: An Essential Validation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15492\" data-end=\"15695\"\u003eThe \u003cstrong data-start=\"15495\" data-end=\"15515\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e operates on \u003cstrong data-start=\"15530\" data-end=\"15559\"\u003e208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e. It requires a \u003cstrong data-start=\"15577\" data-end=\"15594\"\u003eMCA of 14.5 A\u003c\/strong\u003e and a maximum protection of \u003cstrong data-start=\"15622\" data-end=\"15637\"\u003eMOP of 20 A\u003c\/strong\u003e. These specifications must be verified before installation.\u003c\/p\u003e\n\u003cp data-start=\"15697\" data-end=\"16045\"\u003eIn many older homes in Montreal, Laval, or Longueuil, the electrical panel may already be fully loaded. It is therefore necessary to confirm that there is enough space and capacity to add the required circuit. The required communication wire is a \u003cstrong data-start=\"15951\" data-end=\"15986\"\u003e4\/14 copper multi-strand 600 V\u003c\/strong\u003e, an important detail for installation compliance.\u003c\/p\u003e\n\u003cp data-start=\"16047\" data-end=\"16332\"\u003eA poorly assessed electrical installation can cause delays, extra costs, or unexpected adjustments. At AirGreen, we prefer to validate these elements from the start to offer a more realistic quote and avoid unpleasant surprises during the work.\u003c\/p\u003e\n\u003ch2 data-start=\"16334\" data-end=\"16401\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16337\" data-end=\"16401\"\u003eNoise level: a discreet device, but needs proper positioning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16403\" data-end=\"16701\"\u003eThe technical sheet indicates an outdoor sound pressure of \u003cstrong data-start=\"16468\" data-end=\"16480\"\u003e56 dB(A)\u003c\/strong\u003e for the \u003cstrong data-start=\"16489\" data-end=\"16502\"\u003eZE-18CB22\u003c\/strong\u003e. This noise level is reasonable for a unit of this capacity, but the outdoor location remains important, especially in denser neighborhoods or buildings where neighbors are close.\u003c\/p\u003e\n\u003cp data-start=\"16703\" data-end=\"16959\"\u003eIndoors, the noise level varies according to the ventilation speed, with a range of \u003cstrong data-start=\"16792\" data-end=\"16809\"\u003e49 to 33 dB(A)\u003c\/strong\u003e. In silent mode, the device can operate more discreetly, which is appreciated in bedrooms, offices, or relaxation areas.\u003c\/p\u003e\n\u003cp data-start=\"16961\" data-end=\"17376\"\u003eHowever, even a relatively quiet device can become disturbing if poorly placed. The indoor unit should not be installed too close to a bed, a workstation, or a place where occupants sit for long periods. The outdoor unit should also be placed considering neighbors, windows, terraces, balconies, and walls that can reflect sound.\u003c\/p\u003e\n\u003ch2 data-start=\"17378\" data-end=\"17449\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17381\" data-end=\"17449\"\u003ePractical features for easier daily use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17451\" data-end=\"17859\"\u003eThe \u003cstrong data-start=\"17454\" data-end=\"17474\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e includes several features that enhance the user experience. The \u003cstrong data-start=\"17548\" data-end=\"17568\"\u003equick start\u003c\/strong\u003e allows you to reach the desired comfort faster. The \u003cstrong data-start=\"17628\" data-end=\"17646\"\u003eTurbo function\u003c\/strong\u003e is useful when the room needs to be cooled or heated quickly. The \u003cstrong data-start=\"17721\" data-end=\"17753\"\u003eautomatic 8 °C heating\u003c\/strong\u003e can help maintain a minimum temperature in certain spaces when occupants are absent.\u003c\/p\u003e\n\u003cp data-start=\"17861\" data-end=\"18215\"\u003eThe \u003cstrong data-start=\"17864\" data-end=\"17889\"\u003eautomatic cleaning\u003c\/strong\u003e and \u003cstrong data-start=\"17896\" data-end=\"17921\"\u003eautomatic defrosting\u003c\/strong\u003e help maintain the device’s proper operation. The \u003cstrong data-start=\"17986\" data-end=\"18022\"\u003ediffuser position memory\u003c\/strong\u003e makes it easier to restore a comfortable airflow setting. The \u003cstrong data-start=\"18106\" data-end=\"18134\"\u003ereversible drain pipe\u003c\/strong\u003e and \u003cstrong data-start=\"18141\" data-end=\"18163\"\u003etwo-sided drain\u003c\/strong\u003e provide more flexibility during installation.\u003c\/p\u003e\n\u003cp data-start=\"18217\" data-end=\"18612\"\u003eThe brochure also mentions a \u003cstrong data-start=\"18249\" data-end=\"18278\"\u003efireproof electrical box\u003c\/strong\u003e, \u003cstrong data-start=\"18284\" data-end=\"18326\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e, a \u003cstrong data-start=\"18331\" data-end=\"18359\"\u003ecompressor heater\u003c\/strong\u003e, and a \u003cstrong data-start=\"18366\" data-end=\"18411\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e. These features are especially relevant in a Quebec context, where temperature fluctuations, humidity, frost, and winter conditions can challenge equipment.\u003c\/p\u003e\n\u003ch2 data-start=\"18614\" data-end=\"18680\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18617\" data-end=\"18680\"\u003eHVAC Maintenance: maintaining performance year after year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18682\" data-end=\"19010\"\u003eA high-performance wall-mounted heat pump must be properly maintained to retain its efficiency. Even a well-designed model like the \u003cstrong data-start=\"18817\" data-end=\"18837\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e can lose performance if the filters are dirty, the heat exchanger is clogged, the drain is blocked, or the outdoor unit is surrounded by leaves, snow, or debris.\u003c\/p\u003e\n\u003cp data-start=\"19012\" data-end=\"19041\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"19043\" data-end=\"19539\"\u003e• \u003cstrong data-start=\"19045\" data-end=\"19105\"\u003eregularly clean the indoor unit filters\u003c\/strong\u003e;\u003cbr data-start=\"19106\" data-end=\"19109\"\u003e• \u003cstrong data-start=\"19111\" data-end=\"19174\"\u003echeck that the condensation drain flows properly\u003c\/strong\u003e;\u003cbr data-start=\"19175\" data-end=\"19178\"\u003e• \u003cstrong data-start=\"19180\" data-end=\"19233\"\u003ekeep the outdoor unit clear in all seasons\u003c\/strong\u003e;\u003cbr data-start=\"19234\" data-end=\"19237\"\u003e• \u003cstrong data-start=\"19239\" data-end=\"19308\"\u003eremove snow, leaves, and debris around the device\u003c\/strong\u003e;\u003cbr data-start=\"19309\" data-end=\"19312\"\u003e• \u003cstrong data-start=\"19314\" data-end=\"19380\"\u003ewatch for unusual noises or performance loss\u003c\/strong\u003e;\u003cbr data-start=\"19381\" data-end=\"19384\"\u003e• \u003cstrong data-start=\"19386\" data-end=\"19475\"\u003ehave the device inspected if heating or cooling becomes less effective\u003c\/strong\u003e;\u003cbr data-start=\"19476\" data-end=\"19479\"\u003e• \u003cstrong data-start=\"19481\" data-end=\"19538\"\u003eschedule professional maintenance when necessary\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19541\" data-end=\"19701\"\u003eProper maintenance helps preserve comfort, reduce the risk of breakdowns, and assist the device in operating more efficiently for many years.\u003c\/p\u003e\n\u003ch2 data-start=\"19703\" data-end=\"19773\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19706\" data-end=\"19773\"\u003eMistakes to avoid before buying an 18,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"19775\" data-end=\"19937\"\u003eIn our experience, the most common mistakes don’t always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"19939\" data-end=\"19988\"\u003eHere are the mistakes we regularly see:\u003c\/p\u003e\n\u003cp data-start=\"19990\" data-end=\"20686\"\u003e• \u003cstrong data-start=\"19992\" data-end=\"20083\"\u003echoosing an 18,000 BTU heat pump without analyzing the actual space layout\u003c\/strong\u003e;\u003cbr data-start=\"20084\" data-end=\"20087\"\u003e• \u003cstrong data-start=\"20089\" data-end=\"20200\"\u003einstalling the indoor unit in a location convenient for pipes but poor for air distribution\u003c\/strong\u003e;\u003cbr data-start=\"20201\" data-end=\"20204\"\u003e• \u003cstrong data-start=\"20206\" data-end=\"20272\"\u003eforgetting to check the electrical panel before installation\u003c\/strong\u003e;\u003cbr data-start=\"20273\" data-end=\"20276\"\u003e• \u003cstrong data-start=\"20278\" data-end=\"20346\"\u003eassuming old refrigerant lines are compatible\u003c\/strong\u003e;\u003cbr data-start=\"20347\" data-end=\"20350\"\u003e• \u003cstrong data-start=\"20352\" data-end=\"20413\"\u003eneglecting outdoor noise levels in a dense area\u003c\/strong\u003e;\u003cbr data-start=\"20414\" data-end=\"20417\"\u003e• \u003cstrong data-start=\"20419\" data-end=\"20497\"\u003eplacing the outdoor unit too close to a wall, fence, or neighbor\u003c\/strong\u003e;\u003cbr data-start=\"20498\" data-end=\"20501\"\u003e• \u003cstrong data-start=\"20503\" data-end=\"20553\"\u003eignoring snow, ice, and roof water\u003c\/strong\u003e;\u003cbr data-start=\"20554\" data-end=\"20557\"\u003e• \u003cstrong data-start=\"20559\" data-end=\"20600\"\u003eunderestimating the importance of drainage\u003c\/strong\u003e;\u003cbr data-start=\"20601\" data-end=\"20604\"\u003e• \u003cstrong data-start=\"20606\" data-end=\"20685\"\u003ebuying based only on price, without considering installation quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"20688\" data-end=\"20891\"\u003eAt AirGreen, our role is to clarify these points before the work begins. This helps avoid unpleasant surprises and ensures a more durable, cleaner, and better-adapted installation for the building.\u003c\/p\u003e\n\u003ch2 data-start=\"20893\" data-end=\"20960\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"20896\" data-end=\"20960\"\u003eWhy choose AirGreen to install the Zephyr ZE-18CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"20962\" data-end=\"21231\"\u003eAirGreen is an HVAC company specializing in the installation, maintenance, and repair of wall, central, and multi-zone heat pumps in Greater Montreal. We regularly operate in \u003cstrong data-start=\"21152\" data-end=\"21230\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and in Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"21233\" data-end=\"21513\"\u003eOur local knowledge allows us to better understand the realities of Quebec buildings: old houses, modern condos, multiplexes, finished basements, brick walls, open spaces, lower ceilings, neighborhood constraints, and sometimes limited electrical panels.\u003c\/p\u003e\n\u003cp data-start=\"21515\" data-end=\"21631\"\u003eBy choosing AirGreen for the installation of a \u003cstrong data-start=\"21565\" data-end=\"21604\"\u003eZephyr ZE-18CB22 Wall Heat Pump\u003c\/strong\u003e, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"21633\" data-end=\"22104\"\u003e• \u003cstrong data-start=\"21635\" data-end=\"21680\"\u003ea clear assessment before the work\u003c\/strong\u003e;\u003cbr data-start=\"21681\" data-end=\"21684\"\u003e• \u003cstrong data-start=\"21686\" data-end=\"21736\"\u003ea selection of equipment suited to the building\u003c\/strong\u003e;\u003cbr data-start=\"21737\" data-end=\"21740\"\u003e• \u003cstrong data-start=\"21742\" data-end=\"21790\"\u003ea verification of the required capacity\u003c\/strong\u003e;\u003cbr data-start=\"21791\" data-end=\"21794\"\u003e• \u003cstrong data-start=\"21796\" data-end=\"21853\"\u003eanalysis of the indoor and outdoor location\u003c\/strong\u003e;\u003cbr data-start=\"21854\" data-end=\"21857\"\u003e• \u003cstrong data-start=\"21859\" data-end=\"21916\"\u003einstallation compliant with good HVAC practices\u003c\/strong\u003e;\u003cbr data-start=\"21917\" data-end=\"21920\"\u003e• \u003cstrong data-start=\"21922\" data-end=\"21977\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"21978\" data-end=\"21981\"\u003e• \u003cstrong data-start=\"21983\" data-end=\"22059\"\u003esupport to understand the available warranties and options\u003c\/strong\u003e;\u003cbr data-start=\"22060\" data-end=\"22063\"\u003e• \u003cstrong data-start=\"22065\" data-end=\"22103\"\u003estructured after-sales service\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"22106\" data-end=\"22360\"\u003eWe know that a heat pump is a significant investment. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how to use it to achieve the best possible performance.\u003c\/p\u003e\n\u003ch2 data-start=\"22362\" data-end=\"22433\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"22365\" data-end=\"22433\"\u003eA reliable HVAC solution for demanding residential projects\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"22435\" data-end=\"22757\"\u003eThe \u003cstrong data-start=\"22438\" data-end=\"22477\"\u003eZephyr ZE-18CB22 Wall Heat Pump\u003c\/strong\u003e is an interesting choice for homeowners who want an \u003cstrong data-start=\"22561\" data-end=\"22575\"\u003e18,000 BTU\u003c\/strong\u003e wall solution, operating on \u003cstrong data-start=\"22593\" data-end=\"22600\"\u003eR32\u003c\/strong\u003e, with good energy efficiency, an \u003cstrong data-start=\"22659\" data-end=\"22679\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification, heating down to \u003cstrong data-start=\"22702\" data-end=\"22712\"\u003e-25 °C\u003c\/strong\u003e, and several integrated comfort features.\u003c\/p\u003e\n\u003cp data-start=\"22759\" data-end=\"23221\"\u003eIt stands out with its \u003cstrong data-start=\"22785\" data-end=\"22800\"\u003eSEER2 of 20\u003c\/strong\u003e, its \u003cstrong data-start=\"22806\" data-end=\"22822\"\u003eHSPF2 of 9.8\u003c\/strong\u003e, its airflow of \u003cstrong data-start=\"22843\" data-end=\"22860\"\u003e466 to 647 CFM\u003c\/strong\u003e, its outdoor noise level of \u003cstrong data-start=\"22893\" data-end=\"22905\"\u003e56 dB(A)\u003c\/strong\u003e, its 4D mode, silent mode, iFeel mode, and features designed for daily use. However, it requires a serious installation, especially regarding the \u003cstrong data-start=\"23097\" data-end=\"23113\"\u003e1\/4 - 1\/2 inch\u003c\/strong\u003e piping, \u003cstrong data-start=\"23133\" data-end=\"23146\"\u003e208\/230 V\u003c\/strong\u003e power supply, \u003cstrong data-start=\"23151\" data-end=\"23168\"\u003e14.5 A MCA\u003c\/strong\u003e, \u003cstrong data-start=\"23173\" data-end=\"23188\"\u003e20 A MOP\u003c\/strong\u003e, clearances, and drainage.\u003c\/p\u003e\n\u003cp data-start=\"23223\" data-end=\"23541\"\u003eTo get a clear quote, compare this model with other Zephyr options or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925718308,"sku":"ZE-18CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_ab97f646-e268-40a3-af50-4d4a88813231.png?v=1783357002","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-cb22-r32-18000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}