{"product_id":"thermopompe-murale-zephyr-cb22-r32-24000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 24000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"104\" class=\"PDq2pG_selectionAnchorContainer\"\u003eZephyr CB22 R32 ZE-24CB22 wall-mounted heat pump – A robust 24,000 BTU solution for large spaces\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"893\" data-end=\"964\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"896\" data-end=\"964\"\u003eA 24,000 BTU wall-mounted heat pump designed for large spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"966\" data-end=\"1468\"\u003eThe \u003cstrong data-start=\"969\" data-end=\"1017\"\u003eZephyr CB22 R32 ZE-24CB22 wall-mounted heat pump\u003c\/strong\u003e is aimed at owners looking for a powerful, easy-to-use HVAC solution suited for large residential or light commercial spaces. With its \u003cstrong data-start=\"1195\" data-end=\"1226\"\u003e24,000 BTU cooling capacity\u003c\/strong\u003e and \u003cstrong data-start=\"1230\" data-end=\"1266\"\u003e24,000 BTU heating capacity at 8.3 °C\u003c\/strong\u003e, this model is designed to provide serious comfort in a large open area, a spacious ground floor, a large condo, an office, a store, or a room that is difficult to stabilize.\u003c\/p\u003e\n\u003cp data-start=\"1470\" data-end=\"2063\"\u003eAt \u003cstrong data-start=\"1475\" data-end=\"1487\"\u003eAirGreen\u003c\/strong\u003e, we recommend this type of device when the need goes beyond simple occasional cooling. A \u003cstrong data-start=\"1615\" data-end=\"1629\"\u003e24,000 BTU\u003c\/strong\u003e wall-mounted heat pump must be properly sized, well positioned, and installed according to good HVAC practices. In Montreal, Laval, Longueuil, on the South Shore and North Shore, we often see spaces where area alone is not enough to choose the right capacity. You also have to consider \u003cstrong data-start=\"1913\" data-end=\"2062\"\u003einsulation, ceiling height, sun exposure, window area, air circulation, and room layout\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2065\" data-end=\"2475\"\u003eThe Zephyr ZE-24CB22 stands out with its operation on \u003cstrong data-start=\"2124\" data-end=\"2144\"\u003eR-32 refrigerant\u003c\/strong\u003e, its \u003cstrong data-start=\"2161\" data-end=\"2176\"\u003eDC Inverter\u003c\/strong\u003e technology, heating down to \u003cstrong data-start=\"2200\" data-end=\"2210\"\u003e-25 °C\u003c\/strong\u003e, air conditioning mode down to \u003cstrong data-start=\"2243\" data-end=\"2253\"\u003e-15 °C\u003c\/strong\u003e, high airflow, and many comfort functions. It is an interesting machine for customers who want a high-performance wall-mounted heat pump without necessarily opting for a central or multi-zone system.\u003c\/p\u003e\n\u003ch2 data-start=\"2477\" data-end=\"2547\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2480\" data-end=\"2547\"\u003eImportant technical features of the ZE-24CB22 model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2549\" data-end=\"2638\"\u003eFor the model \u003cstrong data-start=\"2564\" data-end=\"2577\"\u003eZE-24CB22\u003c\/strong\u003e, the main brochure data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"2640\" data-end=\"4351\"\u003e• \u003cstrong data-start=\"2642\" data-end=\"2661\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2661\" data-end=\"2664\"\u003e• \u003cstrong data-start=\"2666\" data-end=\"2686\"\u003eSeries: CB22 R32\u003c\/strong\u003e\u003cbr data-start=\"2686\" data-end=\"2689\"\u003e• \u003cstrong data-start=\"2691\" data-end=\"2713\"\u003eModel: ZE-24CB22\u003c\/strong\u003e\u003cbr data-start=\"2713\" data-end=\"2716\"\u003e• \u003cstrong data-start=\"2718\" data-end=\"2747\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2747\" data-end=\"2750\"\u003e• \u003cstrong data-start=\"2752\" data-end=\"2806\"\u003eCooling capacity at 35 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2806\" data-end=\"2809\"\u003e• \u003cstrong data-start=\"2811\" data-end=\"2860\"\u003eHeating capacity at 8.3 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2860\" data-end=\"2863\"\u003e• \u003cstrong data-start=\"2865\" data-end=\"2881\"\u003eSEER2: 19.5\u003c\/strong\u003e\u003cbr data-start=\"2881\" data-end=\"2884\"\u003e• \u003cstrong data-start=\"2886\" data-end=\"2902\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2902\" data-end=\"2905\"\u003e• \u003cstrong data-start=\"2907\" data-end=\"2922\"\u003eEER2: 10.6\u003c\/strong\u003e\u003cbr data-start=\"2922\" data-end=\"2925\"\u003e• \u003cstrong data-start=\"2927\" data-end=\"2959\"\u003eHeating COP at 8.3 °C: 3.3\u003c\/strong\u003e\u003cbr data-start=\"2959\" data-end=\"2962\"\u003e• \u003cstrong data-start=\"2964\" data-end=\"2995\"\u003eHeating COP2: 11.3 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"2995\" data-end=\"2998\"\u003e• \u003cstrong data-start=\"3000\" data-end=\"3059\"\u003eNominal heating capacity at -8.3 °C: 20,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3059\" data-end=\"3062\"\u003e• \u003cstrong data-start=\"3064\" data-end=\"3122\"\u003eMaximum heating capacity at -15 °C: 18,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3122\" data-end=\"3125\"\u003e• \u003cstrong data-start=\"3127\" data-end=\"3185\"\u003eMaximum heating capacity at -20 °C: 16,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3185\" data-end=\"3188\"\u003e• \u003cstrong data-start=\"3190\" data-end=\"3212\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"3212\" data-end=\"3215\"\u003e• \u003cstrong data-start=\"3217\" data-end=\"3239\"\u003eRefrigerant: R-32\u003c\/strong\u003e\u003cbr data-start=\"3239\" data-end=\"3242\"\u003e• \u003cstrong data-start=\"3244\" data-end=\"3280\"\u003eRefrigerant charge: 47.62 oz\u003c\/strong\u003e\u003cbr data-start=\"3280\" data-end=\"3283\"\u003e• \u003cstrong data-start=\"3285\" data-end=\"3316\"\u003eAirflow: 466 to 647 CFM\u003c\/strong\u003e\u003cbr data-start=\"3316\" data-end=\"3319\"\u003e• \u003cstrong data-start=\"3321\" data-end=\"3386\"\u003eIndoor sound pressure: 49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3386\" data-end=\"3389\"\u003e• \u003cstrong data-start=\"3391\" data-end=\"3436\"\u003eOutdoor sound pressure: 60 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3436\" data-end=\"3439\"\u003e• \u003cstrong data-start=\"3441\" data-end=\"3480\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3480\" data-end=\"3483\"\u003e• \u003cstrong data-start=\"3485\" data-end=\"3530\"\u003eNominal cooling current: 10 A\u003c\/strong\u003e\u003cbr data-start=\"3530\" data-end=\"3533\"\u003e• \u003cstrong data-start=\"3535\" data-end=\"3575\"\u003eNominal heating current: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"3575\" data-end=\"3578\"\u003e• \u003cstrong data-start=\"3580\" data-end=\"3594\"\u003eMCA: 21 A\u003c\/strong\u003e\u003cbr data-start=\"3594\" data-end=\"3597\"\u003e• \u003cstrong data-start=\"3599\" data-end=\"3613\"\u003eMOP: 25 A\u003c\/strong\u003e\u003cbr data-start=\"3613\" data-end=\"3616\"\u003e• \u003cstrong data-start=\"3618\" data-end=\"3685\"\u003eRequired communication wire: 4\/14 copper stranded 600 V\u003c\/strong\u003e\u003cbr data-start=\"3685\" data-end=\"3688\"\u003e• \u003cstrong data-start=\"3690\" data-end=\"3720\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"3720\" data-end=\"3723\"\u003e• \u003cstrong data-start=\"3725\" data-end=\"3754\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3754\" data-end=\"3757\"\u003e• \u003cstrong data-start=\"3759\" data-end=\"3788\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3788\" data-end=\"3791\"\u003e• \u003cstrong data-start=\"3793\" data-end=\"3819\"\u003eLiquid pipe: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3819\" data-end=\"3822\"\u003e• \u003cstrong data-start=\"3824\" data-end=\"3846\"\u003eGas pipe: 5\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3846\" data-end=\"3849\"\u003e• \u003cstrong data-start=\"3851\" data-end=\"3897\"\u003eTotal piping length: 10 to 98 ft\u003c\/strong\u003e\u003cbr data-start=\"3897\" data-end=\"3900\"\u003e• \u003cstrong data-start=\"3902\" data-end=\"3936\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"3936\" data-end=\"3939\"\u003e• \u003cstrong data-start=\"3941\" data-end=\"3974\"\u003ePrecharge length: 25 ft\u003c\/strong\u003e\u003cbr data-start=\"3974\" data-end=\"3977\"\u003e• \u003cstrong data-start=\"3979\" data-end=\"4041\"\u003eIndoor unit dimensions: 42 1\/16 x 12 5\/8 x 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4041\" data-end=\"4044\"\u003e• \u003cstrong data-start=\"4046\" data-end=\"4108\"\u003eOutdoor unit dimensions: 33 7\/8 x 25 1\/2 x 12 3\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4108\" data-end=\"4111\" data-is-only-node=\"\"\u003e• \u003cstrong data-start=\"4113\" data-end=\"4176\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4176\" data-end=\"4179\"\u003e• \u003cstrong data-start=\"4181\" data-end=\"4238\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"4238\" data-end=\"4241\"\u003e• \u003cstrong data-start=\"4243\" data-end=\"4286\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"4286\" data-end=\"4289\"\u003e• \u003cstrong data-start=\"4291\" data-end=\"4351\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4353\" data-end=\"4721\"\u003eThis information is essential before any installation. \u003cstrong data-start=\"4414\" data-end=\"4558\"\u003eA 24,000 BTU wall-mounted heat pump on 208\/230 V with a MCA of 21 A and MOP of 25 A is not installed like a small 9,000 or 12,000 BTU unit.\u003c\/strong\u003e The electrical panel, wiring gauge, required protection, piping routing, and clearances around the outdoor unit must be checked.\u003c\/p\u003e\n\u003ch2 data-start=\"4723\" data-end=\"4781\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4726\" data-end=\"4781\"\u003eHeating and cooling performance in Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4783\" data-end=\"5170\"\u003eThe brochure states that the Zephyr CB22 heat pump can provide heating down to \u003cstrong data-start=\"4867\" data-end=\"4877\"\u003e-25 °C\u003c\/strong\u003e and cooling operation down to \u003cstrong data-start=\"4924\" data-end=\"4934\"\u003e-15 °C\u003c\/strong\u003e. For Quebec, this is a very important point, especially for customers located in Montreal, Laval, Longueuil, on the North Shore or South Shore, where winters can quickly vary between humidity, frost, thaw, snow, and severe cold.\u003c\/p\u003e\n\u003cp data-start=\"5172\" data-end=\"5285\"\u003eFor the \u003cstrong data-start=\"5187\" data-end=\"5200\"\u003eZE-24CB22\u003c\/strong\u003e model, low-temperature heating performance deserves special attention:\u003c\/p\u003e\n\u003cp data-start=\"5287\" data-end=\"5377\"\u003e• \u003cstrong data-start=\"5289\" data-end=\"5315\"\u003e20,800 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5315\" data-end=\"5318\"\u003e• \u003cstrong data-start=\"5320\" data-end=\"5345\"\u003e18,200 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"5345\" data-end=\"5348\"\u003e• \u003cstrong data-start=\"5350\" data-end=\"5375\"\u003e16,000 BTU\/h at -20 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5379\" data-end=\"5729\"\u003eThese figures show that the unit maintains useful capacity even when the outside temperature drops. However, it must be clear: \u003cstrong data-start=\"5524\" data-end=\"5640\"\u003ea high-performance wall-mounted heat pump does not always replace 100% of the main heating in all homes\u003c\/strong\u003e, especially in older buildings, poorly insulated, with many windows, or exposed to wind.\u003c\/p\u003e\n\u003cp data-start=\"5731\" data-end=\"6176\"\u003eAt AirGreen, we always explain this reality before installation. A heat pump like the \u003cstrong data-start=\"5832\" data-end=\"5845\"\u003eZE-24CB22\u003c\/strong\u003e can significantly reduce the use of electric baseboards or other supplementary heating, but the actual result will depend on the building. In a large, well-insulated open area, it can provide remarkable comfort. In an older home with closed-off rooms, air distribution can become more complex.\u003c\/p\u003e\n\u003cp data-start=\"6178\" data-end=\"6465\"\u003eIn air conditioning, the capacity of \u003cstrong data-start=\"6211\" data-end=\"6227\"\u003e24,000 BTU\/h\u003c\/strong\u003e allows for treating large spaces. The airflow of \u003cstrong data-start=\"6288\" data-end=\"6305\"\u003e466 to 647 CFM\u003c\/strong\u003e helps move a high volume of air, which is particularly relevant in open rooms or areas where hot air accumulates quickly in summer.\u003c\/p\u003e\n\u003ch2 data-start=\"6467\" data-end=\"6523\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6470\" data-end=\"6523\"\u003eR-32, DC inverter, and stable daily comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6525\" data-end=\"6827\"\u003eThe \u003cstrong data-start=\"6528\" data-end=\"6553\"\u003eZephyr CB22 ZE-24CB22\u003c\/strong\u003e operates with \u003cstrong data-start=\"6568\" data-end=\"6576\"\u003eR-32\u003c\/strong\u003e, a refrigerant used in several new generations of wall-mounted heat pumps. For the customer, the type of refrigerant may sometimes seem secondary, but it is part of the overall design of the device and good installation practices.\u003c\/p\u003e\n\u003cp data-start=\"6829\" data-end=\"7186\"\u003eThe model also uses \u003cstrong data-start=\"6871\" data-end=\"6893\"\u003evariable frequency\u003c\/strong\u003e technology, often called \u003cstrong data-start=\"6911\" data-end=\"6923\"\u003eInverter\u003c\/strong\u003e. This technology allows the heat pump to adjust its power in real time instead of simply operating on an on-off basis. The desired result is more stable comfort, fewer temperature fluctuations, and better-controlled energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"7188\" data-end=\"7528\"\u003eThe brochure highlights this comfort logic: the machine adjusts its power according to the room’s needs. For an owner, this generally means a more consistent temperature, fewer abrupt cycles, and a better comfort feeling, especially in large spaces where air can be harder to balance.\u003c\/p\u003e\n\u003cp data-start=\"7530\" data-end=\"7817\"\u003e\u003cstrong data-start=\"7530\" data-end=\"7578\"\u003eThe installation remains crucial.\u003c\/strong\u003e Even a good Inverter heat pump can deliver mediocre results if the indoor unit is poorly placed, if the refrigerant lines are improperly installed, if the vacuum is not done correctly, or if the outdoor unit lacks clearance.\u003c\/p\u003e\n\u003ch2 data-start=\"7819\" data-end=\"7896\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7822\" data-end=\"7896\"\u003eHVAC installation: points to check before confirming the project\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7898\" data-end=\"8113\"\u003eA 24,000 BTU wall-mounted heat pump installation requires proper planning. At AirGreen, we always consider several factors before recommending or confirming an installation of the \u003cstrong data-start=\"8099\" data-end=\"8112\"\u003eZE-24CB22\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"8115\" data-end=\"8156\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8119\" data-end=\"8156\"\u003eLocation of the indoor unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"8158\" data-end=\"8442\"\u003eThe indoor unit measures \u003cstrong data-start=\"8184\" data-end=\"8216\"\u003e42 1\/16 x 12 5\/8 x 9 1\/16 in\u003c\/strong\u003e. It is therefore wider than a standard small wall-mounted heat pump. You need to plan for a sufficiently clear wall, a good height, a realistic passage for the piping, and an orientation that promotes air diffusion.\u003c\/p\u003e\n\u003cp data-start=\"8444\" data-end=\"8778\"\u003ePositioning is crucial. \u003cstrong data-start=\"8475\" data-end=\"8532\"\u003eA 24,000 BTU unit can move a lot of air.\u003c\/strong\u003e If installed directly facing a sofa, work table, or bed, the customer may feel a draft even if the temperature is correct. The goal is to distribute air in the main area without causing discomfort.\u003c\/p\u003e\n\u003ch3 data-start=\"8780\" data-end=\"8821\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8784\" data-end=\"8821\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"8823\" data-end=\"9186\"\u003eThe outdoor unit measures \u003cstrong data-start=\"8849\" data-end=\"8881\"\u003e33 7\/8 x 25 1\/2 x 12 3\/16 inches\u003c\/strong\u003e. It must be installed on a solid base, with sufficient clearances to allow good air circulation. The indicated outdoor noise level is \u003cstrong data-start=\"9047\" data-end=\"9059\"\u003e60 dB(A)\u003c\/strong\u003e, which must also be considered in denser areas like Montreal, Longueuil, or certain neighborhoods of Laval.\u003c\/p\u003e\n\u003cp data-start=\"9188\" data-end=\"9458\"\u003eIn winter, the location must consider snow, ice, gutters, water drainage, and maintenance access. \u003cstrong data-start=\"9326\" data-end=\"9458\"\u003eA poorly placed outdoor unit can lose performance, accumulate unnecessary ice, or become difficult to maintain.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"9460\" data-end=\"9491\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9464\" data-end=\"9491\"\u003e3\/8 - 5\/8 inch piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"9493\" data-end=\"9793\"\u003eThe model \u003cstrong data-start=\"9503\" data-end=\"9516\"\u003eZE-24CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"9540\" data-end=\"9558\"\u003e3\/8 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"9562\" data-end=\"9576\"\u003e5\/8 inch gas\u003c\/strong\u003e piping. This is a very important point during a replacement. Many customers want to reuse the old lines to reduce work, but you should never assume the existing lines are compatible.\u003c\/p\u003e\n\u003cp data-start=\"9795\" data-end=\"9820\"\u003eWe always check:\u003c\/p\u003e\n\u003cp data-start=\"9822\" data-end=\"10103\"\u003e• the exact diameter of the lines;\u003cbr data-start=\"9853\" data-end=\"9856\"\u003e• the condition of the copper;\u003cbr data-start=\"9875\" data-end=\"9878\"\u003e• the total length;\u003cbr data-start=\"9899\" data-end=\"9902\"\u003e• the old type of refrigerant;\u003cbr data-start=\"9933\" data-end=\"9936\"\u003e• the accessibility of the route;\u003cbr data-start=\"9966\" data-end=\"9969\"\u003e• the possibility of cleanly replacing the lines;\u003cbr data-start=\"10021\" data-end=\"10024\"\u003e• the risks of contamination;\u003cbr data-start=\"10055\" data-end=\"10058\"\u003e• the impact on warranty and performance.\u003c\/p\u003e\n\u003cp data-start=\"10105\" data-end=\"10234\"\u003eIn many situations, \u003cstrong data-start=\"10132\" data-end=\"10185\"\u003ereplacing the piping is the best decision\u003c\/strong\u003e, even if it requires more work initially.\u003c\/p\u003e\n\u003ch3 data-start=\"10236\" data-end=\"10277\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10240\" data-end=\"10277\"\u003ePower supply 208\/230 V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"10279\" data-end=\"10477\"\u003eThe technical sheet indicates a power supply of \u003cstrong data-start=\"10323\" data-end=\"10352\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e, with \u003cstrong data-start=\"10359\" data-end=\"10374\"\u003eMCA of 21 A\u003c\/strong\u003e and \u003cstrong data-start=\"10378\" data-end=\"10393\"\u003eMOP of 25 A\u003c\/strong\u003e. This means an electrical inspection is mandatory before installation.\u003c\/p\u003e\n\u003cp data-start=\"10479\" data-end=\"10770\"\u003eIn some older homes, the electrical panel may already be fully loaded. It is then necessary to check the available space, panel capacity, required breaker, and wire gauge. \u003cstrong data-start=\"10675\" data-end=\"10770\"\u003eA realistic installation price must take this electrical part into account from the start.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"10772\" data-end=\"10826\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10775\" data-end=\"10826\"\u003eNoise level, airflow, and indoor comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10828\" data-end=\"11109\"\u003eThe ZE-24CB22 has an indoor sound pressure level indicated at \u003cstrong data-start=\"10895\" data-end=\"10927\"\u003e49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e depending on speeds, with a lower level in silent mode. For a high-capacity unit, these levels are consistent with a machine designed to move a good volume of air.\u003c\/p\u003e\n\u003cp data-start=\"11111\" data-end=\"11499\"\u003eThe airflow of \u003cstrong data-start=\"11129\" data-end=\"11146\"\u003e466 to 647 CFM\u003c\/strong\u003e is particularly important. It allows the unit to better distribute heat or coolness in an open space. But again, it all depends on the actual setup. In an open area, this airflow can be a major advantage. In a closed or poorly oriented room, it can become too powerful if the machine is oversized.\u003c\/p\u003e\n\u003cp data-start=\"11501\" data-end=\"11958\"\u003e\u003cstrong data-start=\"11501\" data-end=\"11547\"\u003eProper sizing is therefore essential.\u003c\/strong\u003e A 24,000 BTU unit should not be chosen simply because it is “stronger.” An overly powerful device can quickly reach the temperature in cooling mode but reduce dehumidification time. Result: the room may feel cool but still humid. Conversely, an undersized unit will run constantly and struggle during very hot or very cold days.\u003c\/p\u003e\n\u003ch2 data-start=\"11960\" data-end=\"12043\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11963\" data-end=\"12043\"\u003ePractical features: 4D mode, silent, night, iFeel, and automatic cleaning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12045\" data-end=\"12155\"\u003eThe brochure presents several interesting features for daily comfort. Among the most important:\u003c\/p\u003e\n\u003cp data-start=\"12157\" data-end=\"12828\"\u003e• \u003cstrong data-start=\"12159\" data-end=\"12172\"\u003eNight Mode\u003c\/strong\u003e\u003cbr data-start=\"12172\" data-end=\"12175\"\u003e• \u003cstrong data-start=\"12177\" data-end=\"12193\"\u003eSilent Mode\u003c\/strong\u003e\u003cbr data-start=\"12193\" data-end=\"12196\"\u003e• \u003cstrong data-start=\"12198\" data-end=\"12212\"\u003eiFeel Mode\u003c\/strong\u003e\u003cbr data-start=\"12212\" data-end=\"12215\"\u003e• \u003cstrong data-start=\"12217\" data-end=\"12237\"\u003eQuick Start\u003c\/strong\u003e\u003cbr data-start=\"12237\" data-end=\"12240\"\u003e• \u003cstrong data-start=\"12242\" data-end=\"12263\"\u003eBase Heating\u003c\/strong\u003e\u003cbr data-start=\"12263\" data-end=\"12266\"\u003e• \u003cstrong data-start=\"12268\" data-end=\"12296\"\u003eCompressor Heating\u003c\/strong\u003e\u003cbr data-start=\"12296\" data-end=\"12299\"\u003e• \u003cstrong data-start=\"12301\" data-end=\"12349\"\u003eChassis Heating for Outdoor Base\u003c\/strong\u003e\u003cbr data-start=\"12349\" data-end=\"12352\"\u003e• \u003cstrong data-start=\"12354\" data-end=\"12383\"\u003eFire-Resistant Electrical Box\u003c\/strong\u003e\u003cbr data-start=\"12383\" data-end=\"12386\"\u003e• \u003cstrong data-start=\"12388\" data-end=\"12430\"\u003eAuto-Adaptive Voltage Technology\u003c\/strong\u003e\u003cbr data-start=\"12430\" data-end=\"12433\"\u003e• \u003cstrong data-start=\"12435\" data-end=\"12454\"\u003eTwo-Sided Drain\u003c\/strong\u003e\u003cbr data-start=\"12454\" data-end=\"12457\"\u003e• \u003cstrong data-start=\"12459\" data-end=\"12477\"\u003e24-Hour Timer\u003c\/strong\u003e\u003cbr data-start=\"12477\" data-end=\"12480\"\u003e• \u003cstrong data-start=\"12482\" data-end=\"12509\"\u003eAutomatic Oscillation\u003c\/strong\u003e\u003cbr data-start=\"12509\" data-end=\"12512\"\u003e• \u003cstrong data-start=\"12514\" data-end=\"12525\"\u003e4D Mode\u003c\/strong\u003e\u003cbr data-start=\"12525\" data-end=\"12528\"\u003e• \u003cstrong data-start=\"12530\" data-end=\"12549\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"12549\" data-end=\"12552\"\u003e• \u003cstrong data-start=\"12554\" data-end=\"12594\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"12594\" data-end=\"12597\"\u003e• \u003cstrong data-start=\"12599\" data-end=\"12628\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"12628\" data-end=\"12631\"\u003e• \u003cstrong data-start=\"12633\" data-end=\"12671\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"12671\" data-end=\"12674\"\u003e• \u003cstrong data-start=\"12676\" data-end=\"12704\"\u003eReversible drain hose\u003c\/strong\u003e\u003cbr data-start=\"12704\" data-end=\"12707\"\u003e• \u003cstrong data-start=\"12709\" data-end=\"12727\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"12727\" data-end=\"12730\"\u003e• \u003cstrong data-start=\"12732\" data-end=\"12757\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"12757\" data-end=\"12760\"\u003e• \u003cstrong data-start=\"12762\" data-end=\"12787\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"12787\" data-end=\"12790\"\u003e• \u003cstrong data-start=\"12792\" data-end=\"12828\"\u003eDiffuser position memory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"12830\" data-end=\"13258\"\u003eThe \u003cstrong data-start=\"12833\" data-end=\"12844\"\u003e4D mode\u003c\/strong\u003e and automatic oscillation allow better air distribution in the room. This is useful to avoid cold or hot spots, especially in a large open area. The \u003cstrong data-start=\"13031\" data-end=\"13045\"\u003eiFeel mode\u003c\/strong\u003e helps adjust comfort based on the temperature sensed near the remote control. The \u003cstrong data-start=\"13131\" data-end=\"13147\"\u003esilent mode\u003c\/strong\u003e and \u003cstrong data-start=\"13154\" data-end=\"13167\"\u003enight mode\u003c\/strong\u003e are convenient for reducing noise when a quieter operation is desired.\u003c\/p\u003e\n\u003cp data-start=\"13260\" data-end=\"13581\"\u003eThe \u003cstrong data-start=\"13263\" data-end=\"13284\"\u003ebasic heating\u003c\/strong\u003e, \u003cstrong data-start=\"13289\" data-end=\"13317\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"13324\" data-end=\"13369\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e are particularly useful in a climate like Quebec’s. These features help support the unit’s winter operation, especially when outdoor conditions are harsh.\u003c\/p\u003e\n\u003ch2 data-start=\"13583\" data-end=\"13629\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13586\" data-end=\"13629\"\u003eZephyr maintenance, reliability, and warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13631\" data-end=\"14002\"\u003eThe brochure states a \u003cstrong data-start=\"13655\" data-end=\"13707\"\u003e10-year Zephyr basic parts warranty\u003c\/strong\u003e. It also mentions that a labor warranty is available, depending on the distributor. For the customer, this means clarifying the coverage offered before purchase: parts, labor, diagnostics, travel, maintenance conditions, and warranty registration.\u003c\/p\u003e\n\u003cp data-start=\"14004\" data-end=\"14145\"\u003eA wall-mounted heat pump like the \u003cstrong data-start=\"14036\" data-end=\"14049\"\u003eZE-24CB22\u003c\/strong\u003e must be maintained regularly to retain its efficiency. We especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"14147\" data-end=\"14482\"\u003e• clean the indoor filters frequently;\u003cbr data-start=\"14193\" data-end=\"14196\"\u003e• keep the outdoor unit clear;\u003cbr data-start=\"14232\" data-end=\"14235\"\u003e• check the condensation drain;\u003cbr data-start=\"14271\" data-end=\"14274\"\u003e• monitor abnormal ice buildup;\u003cbr data-start=\"14324\" data-end=\"14327\"\u003e• have the device inspected if the noise changes;\u003cbr data-start=\"14375\" data-end=\"14378\"\u003e• clean the heat exchanger when necessary;\u003cbr data-start=\"14420\" data-end=\"14423\"\u003e• schedule professional maintenance according to usage.\u003c\/p\u003e\n\u003cp data-start=\"14484\" data-end=\"14763\"\u003e\u003cstrong data-start=\"14484\" data-end=\"14599\"\u003eProper maintenance extends the device’s lifespan, maintains performance, and reduces the risk of breakdowns.\u003c\/strong\u003e Features like automatic cleaning or automatic defrosting are useful, but they do not replace a clean installation or serious maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"14765\" data-end=\"14825\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14768\" data-end=\"14825\"\u003eWhy choose AirGreen to install the ZE-24CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14827\" data-end=\"15165\"\u003eAt \u003cstrong data-start=\"14832\" data-end=\"14844\"\u003eAirGreen\u003c\/strong\u003e, we install HVAC systems in houses, condos, plexes, businesses, and offices in Montreal, Laval, Longueuil, on the South Shore, and the North Shore. Our role is not limited to mounting a heat pump on the wall. We analyze the project to choose the right device, the right location, and the right installation method.\u003c\/p\u003e\n\u003cp data-start=\"15167\" data-end=\"15244\"\u003eFor a model like the \u003cstrong data-start=\"15191\" data-end=\"15220\"\u003eZephyr CB22 R32 ZE-24CB22\u003c\/strong\u003e, our team checks:\u003c\/p\u003e\n\u003cp data-start=\"15246\" data-end=\"15575\"\u003e• required capacity according to the space;\u003cbr data-start=\"15286\" data-end=\"15289\"\u003e• optimal location of the indoor unit;\u003cbr data-start=\"15335\" data-end=\"15338\"\u003e• location of the outdoor unit;\u003cbr data-start=\"15376\" data-end=\"15379\"\u003e• piping routing;\u003cbr data-start=\"15409\" data-end=\"15412\"\u003e• electrical compatibility;\u003cbr data-start=\"15442\" data-end=\"15445\"\u003e• clearances;\u003cbr data-start=\"15463\" data-end=\"15466\"\u003e• drainage;\u003cbr data-start=\"15480\" data-end=\"15483\"\u003e• winter constraints;\u003cbr data-start=\"15509\" data-end=\"15512\"\u003e• access for maintenance;\u003cbr data-start=\"15539\" data-end=\"15542\"\u003e• the client’s actual expectations.\u003c\/p\u003e\n\u003cp data-start=\"15577\" data-end=\"15826\"\u003eThis approach avoids several common mistakes: device too powerful, poor air distribution, outdoor unit too close to an obstacle, incompatible refrigerant line, undervalued electrical circuit, or installation difficult to maintain.\u003c\/p\u003e\n\u003cp data-start=\"15828\" data-end=\"16231\"\u003eThe \u003cstrong data-start=\"15831\" data-end=\"15844\"\u003eZE-24CB22\u003c\/strong\u003e is an interesting wall-mounted heat pump for large spaces that require good heating and cooling capacity. With its \u003cstrong data-start=\"15985\" data-end=\"15999\"\u003e24,000 BTU\u003c\/strong\u003e, \u003cstrong data-start=\"16005\" data-end=\"16025\"\u003eR-32 refrigerant\u003c\/strong\u003e, operation down to \u003cstrong data-start=\"16054\" data-end=\"16077\"\u003e-25 °C in heating mode\u003c\/strong\u003e, \u003cstrong data-start=\"16083\" data-end=\"16104\"\u003ehigh airflow\u003c\/strong\u003e, \u003cstrong data-start=\"16110\" data-end=\"16121\"\u003e4D mode\u003c\/strong\u003e, and \u003cstrong data-start=\"16128\" data-end=\"16157\"\u003e10-year parts warranty\u003c\/strong\u003e, it can be a solid HVAC solution for many projects.\u003c\/p\u003e\n\u003cp data-start=\"16233\" data-end=\"16559\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact \u003cstrong data-start=\"16426\" data-end=\"16438\"\u003eAirGreen\u003c\/strong\u003e. Our team will help you choose a solution suited to your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925816612,"sku":"ZE-24CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_c834f35b-c9bd-4d70-a050-3cd92ecb6753.png?v=1783357007","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-cb22-r32-24000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}