{"product_id":"thermopompe-murale-zephyr-cb22-r32-9000-btu-115v","title":"ZEPHYR CB22 R32 Wall Heat Pump | 9000 BTU 115V","description":"\u003ch1 data-start=\"0\" data-end=\"62\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"62\"\u003eZephyr ZE-09DB22 R32 Wall-Mounted Heat Pump – 9,000 BTU 115V\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"64\" data-end=\"732\"\u003eThe \u003cstrong data-start=\"67\" data-end=\"120\"\u003eZephyr ZE-09DB22 R32 9,000 BTU wall-mounted heat pump\u003c\/strong\u003e is a compact, practical, and efficient HVAC solution for owners who want to cool and heat a specific room, a bedroom, an office, a small condo, a closed family room, or a residential space where a high-capacity unit would simply be too powerful. At \u003cstrong data-start=\"422\" data-end=\"434\"\u003eAirGreen\u003c\/strong\u003e, we recommend this type of device when the need is clear: to achieve \u003cstrong data-start=\"514\" data-end=\"532\"\u003estable comfort\u003c\/strong\u003e, good heating performance, easier installation thanks to the \u003cstrong data-start=\"622\" data-end=\"630\"\u003e115V\u003c\/strong\u003e power supply, and a wall-mounted solution suited to the realities of houses, condos, and small spaces in Greater Montreal.\u003c\/p\u003e\n\u003cp data-start=\"734\" data-end=\"1390\"\u003eThis model is part of the \u003cstrong data-start=\"768\" data-end=\"783\"\u003eZephyr CB22\u003c\/strong\u003e series, operating with \u003cstrong data-start=\"801\" data-end=\"820\"\u003eR32 refrigerant\u003c\/strong\u003e. It stands out for its cooling capacity of \u003cstrong data-start=\"876\" data-end=\"891\"\u003e9,000 BTU\/h\u003c\/strong\u003e, heating capacity of \u003cstrong data-start=\"921\" data-end=\"946\"\u003e12,000 BTU\/h at 8.3 °C\u003c\/strong\u003e, heating operation down to \u003cstrong data-start=\"988\" data-end=\"998\"\u003e-25 °C\u003c\/strong\u003e, cooling possible down to \u003cstrong data-start=\"1034\" data-end=\"1054\"\u003e-15 °C outdoor\u003c\/strong\u003e, as well as many comfort features such as \u003cstrong data-start=\"1111\" data-end=\"1124\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1129\" data-end=\"1145\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1150\" data-end=\"1164\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1169\" data-end=\"1189\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"1194\" data-end=\"1208\"\u003eTurbo mode\u003c\/strong\u003e, \u003cstrong data-start=\"1213\" data-end=\"1238\"\u003eautomatic defrost\u003c\/strong\u003e, and \u003cstrong data-start=\"1245\" data-end=\"1270\"\u003eautomatic cleaning\u003c\/strong\u003e. These features are listed in the Zephyr CB22 brochure used for this model.\u003c\/p\u003e\n\u003cp data-start=\"1392\" data-end=\"1836\"\u003eThe Zephyr ZE-09DB22 is not a heat pump designed for a large open area or a whole floor heavily exposed to the sun. It is rather designed to provide \u003cstrong data-start=\"1555\" data-end=\"1572\"\u003etargeted comfort\u003c\/strong\u003e in a well-defined zone. This is precisely what makes it interesting: when a customer is looking for a discreet, relatively compact machine capable of heating and cooling a room without oversizing the system, this model can become an excellent choice.\u003c\/p\u003e\n\u003cp data-start=\"1838\" data-end=\"2367\"\u003eAt AirGreen, we know that a \u003cstrong data-start=\"1894\" data-end=\"1907\"\u003e9,000 BTU\u003c\/strong\u003e wall-mounted heat pump must be selected precisely. A unit that is too small will run constantly and struggle to maintain comfort. A unit that is too large risks cooling too quickly without properly dehumidifying the air. For this reason, we always assess the area, insulation, ceiling height, windows, solar orientation, air circulation, building type, and customer expectations before confirming the installation.\u003c\/p\u003e\n\u003ch2 data-start=\"2369\" data-end=\"2431\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2372\" data-end=\"2431\"\u003eThe important technical specifications to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2433\" data-end=\"2534\"\u003eFor the model \u003cstrong data-start=\"2448\" data-end=\"2468\"\u003eZephyr ZE-09DB22\u003c\/strong\u003e, the main brochure information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"2536\" data-end=\"3822\"\u003e• \u003cstrong data-start=\"2538\" data-end=\"2557\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2557\" data-end=\"2560\"\u003e• \u003cstrong data-start=\"2562\" data-end=\"2578\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2578\" data-end=\"2581\"\u003e• \u003cstrong data-start=\"2583\" data-end=\"2605\"\u003eModel: ZE-09DB22\u003c\/strong\u003e\u003cbr data-start=\"2605\" data-end=\"2608\"\u003e• \u003cstrong data-start=\"2610\" data-end=\"2639\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2639\" data-end=\"2642\"\u003e• \u003cstrong data-start=\"2644\" data-end=\"2697\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2697\" data-end=\"2700\"\u003e• \u003cstrong data-start=\"2702\" data-end=\"2751\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2751\" data-end=\"2754\"\u003e• \u003cstrong data-start=\"2756\" data-end=\"2777\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003e• \u003cstrong data-start=\"2782\" data-end=\"2798\"\u003eSEER2: 20.0\u003c\/strong\u003e\u003cbr data-start=\"2798\" data-end=\"2801\"\u003e• \u003cstrong data-start=\"2803\" data-end=\"2821\"\u003eHSPF2 IV: 8.0\u003c\/strong\u003e\u003cbr data-start=\"2821\" data-end=\"2824\"\u003e• \u003cstrong data-start=\"2826\" data-end=\"2847\"\u003eEER2: 10.4 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"2847\" data-end=\"2850\"\u003e• \u003cstrong data-start=\"2852\" data-end=\"2884\"\u003eHeating COP at 8.3 °C: 3.4\u003c\/strong\u003e\u003cbr data-start=\"2884\" data-end=\"2887\"\u003e• \u003cstrong data-start=\"2889\" data-end=\"2911\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"2911\" data-end=\"2914\"\u003e• \u003cstrong data-start=\"2916\" data-end=\"2942\"\u003eEnergy Star V6.1: No\u003c\/strong\u003e\u003cbr data-start=\"2942\" data-end=\"2945\"\u003e• \u003cstrong data-start=\"2947\" data-end=\"2988\"\u003eIndoor airflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"2988\" data-end=\"2991\"\u003e• \u003cstrong data-start=\"2993\" data-end=\"3060\"\u003eIndoor sound pressure: 46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3060\" data-end=\"3063\"\u003e• \u003cstrong data-start=\"3065\" data-end=\"3110\"\u003eOutdoor sound pressure: 52 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3110\" data-end=\"3113\"\u003e• \u003cstrong data-start=\"3115\" data-end=\"3149\"\u003eVoltage: 115V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3149\" data-end=\"3152\"\u003e• \u003cstrong data-start=\"3154\" data-end=\"3199\"\u003eNominal cooling current: 10.5 A\u003c\/strong\u003e\u003cbr data-start=\"3199\" data-end=\"3202\"\u003e• \u003cstrong data-start=\"3204\" data-end=\"3244\"\u003eNominal heating current: 9.4 A\u003c\/strong\u003e\u003cbr data-start=\"3244\" data-end=\"3247\"\u003e• \u003cstrong data-start=\"3249\" data-end=\"3265\"\u003eMCA: 15.6 A\u003c\/strong\u003e\u003cbr data-start=\"3265\" data-end=\"3268\"\u003e• \u003cstrong data-start=\"3270\" data-end=\"3284\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"3284\" data-end=\"3287\"\u003e• \u003cstrong data-start=\"3289\" data-end=\"3352\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"3352\" data-end=\"3355\"\u003e• \u003cstrong data-start=\"3357\" data-end=\"3387\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"3387\" data-end=\"3390\"\u003e• \u003cstrong data-start=\"3392\" data-end=\"3435\"\u003eExpansion device: capillary tube\u003c\/strong\u003e\u003cbr data-start=\"3435\" data-end=\"3438\"\u003e• \u003cstrong data-start=\"3440\" data-end=\"3469\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3469\" data-end=\"3472\"\u003e• \u003cstrong data-start=\"3474\" data-end=\"3503\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3503\" data-end=\"3506\"\u003e• \u003cstrong data-start=\"3508\" data-end=\"3539\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3539\" data-end=\"3542\"\u003e• \u003cstrong data-start=\"3544\" data-end=\"3571\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3571\" data-end=\"3574\"\u003e• \u003cstrong data-start=\"3576\" data-end=\"3626\"\u003eMinimum-maximum piping length: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3626\" data-end=\"3629\"\u003e• \u003cstrong data-start=\"3631\" data-end=\"3668\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3668\" data-end=\"3671\"\u003e• \u003cstrong data-start=\"3673\" data-end=\"3709\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3709\" data-end=\"3712\"\u003e• \u003cstrong data-start=\"3714\" data-end=\"3757\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"3757\" data-end=\"3760\"\u003e• \u003cstrong data-start=\"3762\" data-end=\"3822\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3824\" data-end=\"3979\"\u003eThe brochure presents the dimensions in \u003cstrong data-start=\"3870\" data-end=\"3883\"\u003eW × H × D\u003c\/strong\u003e format. For easier reading during installation, here are the dimensions in \u003cstrong data-start=\"3964\" data-end=\"3977\"\u003eW × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3981\" data-end=\"4080\"\u003e• \u003cstrong data-start=\"3983\" data-end=\"4029\"\u003eIndoor unit: 33.44 × 8.06 × 11.56 in\u003c\/strong\u003e\u003cbr data-start=\"4029\" data-end=\"4032\"\u003e• \u003cstrong data-start=\"4034\" data-end=\"4080\"\u003eOutdoor unit: 28.13 × 9.50 × 21.25 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4082\" data-end=\"4572\"\u003eThese dimensions are important, especially in condos, bedrooms, offices, or rooms where wall space is limited. An indoor unit of \u003cstrong data-start=\"4234\" data-end=\"4257\"\u003e33.44 inches wide\u003c\/strong\u003e requires a sufficiently clear wall, with enough space around it to ensure good air distribution. The outdoor unit, more compact than those of higher capacity models, sometimes facilitates installation on a wall bracket, balcony, side yard, or outdoor base, depending on the building constraints.\u003c\/p\u003e\n\u003ch2 data-start=\"4574\" data-end=\"4647\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4577\" data-end=\"4647\"\u003eA 9,000 BTU heat pump designed for small and medium spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4649\" data-end=\"5006\"\u003eThe \u003cstrong data-start=\"4652\" data-end=\"4682\"\u003eZephyr ZE-09DB22 9,000 BTU\u003c\/strong\u003e is generally suitable for closed or semi-open rooms where the heat load remains reasonable. It can be relevant for a master bedroom, a home office, a compact living room, a basement room, a small condo, or a space where the customer wants to control the temperature independently.\u003c\/p\u003e\n\u003cp data-start=\"5008\" data-end=\"5425\"\u003eIn a house in \u003cstrong data-start=\"5026\" data-end=\"5038\"\u003eMontreal\u003c\/strong\u003e, this type of device can be very useful in an upstairs bedroom that gets too hot in the summer. In \u003cstrong data-start=\"5140\" data-end=\"5149\"\u003eLaval\u003c\/strong\u003e, it can meet the needs of a home office exposed to the sun. On the \u003cstrong data-start=\"5226\" data-end=\"5238\"\u003eSouth Shore\u003c\/strong\u003e, it can suit a smaller living space or an annex. On the \u003cstrong data-start=\"5311\" data-end=\"5324\"\u003eNorth Shore\u003c\/strong\u003e, it can be used in a closed room where electric heating is expensive or uncomfortable.\u003c\/p\u003e\n\u003cp data-start=\"5427\" data-end=\"5813\"\u003eHowever, we always avoid recommending capacity based solely on area. A room of the same size may require different capacity depending on its insulation, orientation, number of windows, wind exposure, or daily use. \u003cstrong data-start=\"5694\" data-end=\"5734\"\u003eProper sizing is essential\u003c\/strong\u003e to achieve stable comfort and avoid cycles that are too short or too long.\u003c\/p\u003e\n\u003cp data-start=\"5815\" data-end=\"6162\"\u003eA \u003cstrong data-start=\"5834\" data-end=\"5847\"\u003e9,000 BTU\u003c\/strong\u003e heat pump is often interesting when a targeted solution is desired, but it is not intended to replace a central system for an entire house. At AirGreen, we take the time to explain this nuance because it helps avoid unrealistic expectations and offers a solution truly adapted to the building.\u003c\/p\u003e\n\u003ch2 data-start=\"6164\" data-end=\"6246\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6167\" data-end=\"6246\"\u003eR32 refrigerant: a modern choice for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6248\" data-end=\"6501\"\u003eThe Zephyr ZE-09DB22 operates with \u003cstrong data-start=\"6282\" data-end=\"6301\"\u003eR32 refrigerant\u003c\/strong\u003e. This refrigerant is increasingly used in modern wall-mounted heat pumps. It allows manufacturers to design newer equipment adapted to the new HVAC market requirements.\u003c\/p\u003e\n\u003cp data-start=\"6503\" data-end=\"6858\"\u003eFor the client, the type of refrigerant may seem technical, but it directly influences installation methods. A heat pump with \u003cstrong data-start=\"6644\" data-end=\"6651\"\u003eR32\u003c\/strong\u003e must be installed with rigor: flares must be clean, fittings must be tight, lines must be properly tested, and vacuum pulling must be done thoroughly.\u003c\/p\u003e\n\u003cp data-start=\"6860\" data-end=\"7214\"\u003eAt AirGreen, we place great importance on these steps. A modern heat pump can perform well on paper, but if the installation is sloppy, the result can be disappointing: loss of performance, noise, leaks, poor drainage, or reduced lifespan. \u003cstrong data-start=\"7137\" data-end=\"7214\"\u003eThe quality of the installation is as important as the choice of model.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"7216\" data-end=\"7298\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7219\" data-end=\"7298\"\u003eEnergy performance: understanding the numbers without isolating them from the project\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7300\" data-end=\"7545\"\u003eThe technical sheet indicates a \u003cstrong data-start=\"7330\" data-end=\"7347\"\u003eSEER2 of 20.0\u003c\/strong\u003e, an \u003cstrong data-start=\"7352\" data-end=\"7371\"\u003eHSPF2 IV of 8.0\u003c\/strong\u003e, an \u003cstrong data-start=\"7376\" data-end=\"7398\"\u003eEER2 of 10.4 Btu\/W\u003c\/strong\u003e, and a \u003cstrong data-start=\"7405\" data-end=\"7441\"\u003eheating COP at 8.3 °C of 3.4\u003c\/strong\u003e. These values provide an indication of the heat pump’s efficiency in air conditioning and heating.\u003c\/p\u003e\n\u003cp data-start=\"7547\" data-end=\"7849\"\u003eThe \u003cstrong data-start=\"7550\" data-end=\"7559\"\u003eSEER2\u003c\/strong\u003e represents the seasonal efficiency in air conditioning. The \u003cstrong data-start=\"7617\" data-end=\"7626\"\u003eHSPF2\u003c\/strong\u003e gives an idea of heating efficiency over a season. The \u003cstrong data-start=\"7690\" data-end=\"7698\"\u003eEER2\u003c\/strong\u003e measures efficiency in air conditioning under specific conditions. The \u003cstrong data-start=\"7769\" data-end=\"7776\"\u003eCOP\u003c\/strong\u003e indicates the ratio between heat produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"7851\" data-end=\"8222\"\u003eFor an owner, the important thing is to understand that these figures must be read in the context of the building. A heat pump installed in a well-insulated room, with good air circulation and an appropriate location, will generally offer better comfort than a device installed in a poorly chosen spot, even if the technical figures seem good.\u003c\/p\u003e\n\u003cp data-start=\"8224\" data-end=\"8657\"\u003eIt should also be noted that the sheet indicates \u003cstrong data-start=\"8265\" data-end=\"8291\"\u003eEnergy Star V6.1: No\u003c\/strong\u003e for the \u003cstrong data-start=\"8307\" data-end=\"8320\"\u003eZE-09DB22\u003c\/strong\u003e model. This does not mean the device is not interesting, but it should be considered if the customer is specifically looking for a heat pump eligible for certain energy efficiency programs. Before discussing subsidies, we always recommend checking the current program criteria and the exact model installed.\u003c\/p\u003e\n\u003ch2 data-start=\"8659\" data-end=\"8733\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8662\" data-end=\"8733\"\u003eHeating down to -25 °C: what it means in Quebec’s climate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8735\" data-end=\"8979\"\u003eThe Zephyr CB22 brochure states that the heat pump can operate in heating mode down to an outdoor temperature of \u003cstrong data-start=\"8854\" data-end=\"8864\"\u003e-25 °C\u003c\/strong\u003e. This is an important point for Quebec winters. However, it is necessary to clearly explain what this means.\u003c\/p\u003e\n\u003cp data-start=\"8981\" data-end=\"9188\"\u003eA heat pump can continue to operate at low temperatures, but its heating capacity generally decreases as the cold intensifies. For the \u003cstrong data-start=\"9145\" data-end=\"9158\"\u003eZE-09DB22\u003c\/strong\u003e, the technical sheet indicates:\u003c\/p\u003e\n\u003cp data-start=\"9190\" data-end=\"9362\"\u003e• \u003cstrong data-start=\"9192\" data-end=\"9237\"\u003eNominal capacity at -8.3 °C: 7,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9237\" data-end=\"9240\"\u003e• \u003cstrong data-start=\"9242\" data-end=\"9286\"\u003eMaximum capacity at -15 °C: 6,100 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9286\" data-end=\"9289\"\u003e• \u003cstrong data-start=\"9291\" data-end=\"9335\"\u003eMaximum capacity at -20 °C: 5,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9335\" data-end=\"9338\"\u003e• \u003cstrong data-start=\"9340\" data-end=\"9362\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9364\" data-end=\"9720\"\u003eThis data is very useful to know what to expect in winter. In a well-insulated room, the heat pump can provide a good portion of the necessary heating for much of the season. In a more exposed room, poorly insulated or with large windows, supplementary heating may still be needed on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"9722\" data-end=\"9989\"\u003eAt AirGreen, we always prefer to explain this point before installation. \u003cstrong data-start=\"9802\" data-end=\"9880\"\u003eA wall-mounted heat pump can reduce the use of electric baseboards\u003c\/strong\u003e, improve comfort, and stabilize temperature, but it must be intelligently integrated into the building.\u003c\/p\u003e\n\u003ch2 data-start=\"9991\" data-end=\"10068\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9994\" data-end=\"10068\"\u003eAir conditioning down to -15 °C outside: useful in certain contexts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10070\" data-end=\"10638\"\u003eThe brochure also states that the air conditioning mode can cool down to an outdoor temperature of \u003cstrong data-start=\"10180\" data-end=\"10190\"\u003e-15 °C\u003c\/strong\u003e. For standard residential use, this information is not always a priority, as air conditioning is mainly used during hot periods. However, it can be interesting in certain contexts: technical rooms, small businesses, spaces with many electronic devices, rooms very exposed to the sun, or buildings where internal heat remains high even when the outdoor temperature is cooler.\u003c\/p\u003e\n\u003cp data-start=\"10640\" data-end=\"10953\"\u003eThe cooling operating range is indicated as \u003cstrong data-start=\"10702\" data-end=\"10720\"\u003e-15 °C to 48 °C\u003c\/strong\u003e, providing good usage flexibility. In summer, a capacity of \u003cstrong data-start=\"10809\" data-end=\"10824\"\u003e9,000 BTU\/h\u003c\/strong\u003e can be perfectly suited to stabilize a closed room, reduce perceived humidity, and improve daily comfort.\u003c\/p\u003e\n\u003ch2 data-start=\"10955\" data-end=\"11011\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10958\" data-end=\"11011\"\u003eInstallation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11013\" data-end=\"11203\"\u003eA good wall-mounted heat pump installation always starts with good planning. For the \u003cstrong data-start=\"11113\" data-end=\"11133\"\u003eZephyr ZE-09DB22\u003c\/strong\u003e, several technical details must be verified before work begins.\u003c\/p\u003e\n\u003ch2 data-start=\"11205\" data-end=\"11245\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11208\" data-end=\"11245\"\u003eIndoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11247\" data-end=\"11506\"\u003eThe indoor unit should be placed to distribute air well without blowing directly on occupants for long periods. The airflow of this model ranges between \u003cstrong data-start=\"11431\" data-end=\"11449\"\u003e253 and 400 CFM\u003c\/strong\u003e, which is suitable for a reasonably sized room.\u003c\/p\u003e\n\u003cp data-start=\"11508\" data-end=\"11885\"\u003eWe analyze the shape of the room, the position of the bed, desk, sofa, windows, doors, stairs, and exterior walls. In many condos in Montreal or Longueuil, wall space can be limited by closets, windows, curtains, or concrete walls. Good planning results in a more aesthetic and efficient outcome.\u003c\/p\u003e\n\u003ch2 data-start=\"11887\" data-end=\"11927\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11890\" data-end=\"11927\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11929\" data-end=\"12220\"\u003eThe outdoor unit must be installed in a stable, accessible, and well-ventilated location. The indicated outdoor sound pressure level is \u003cstrong data-start=\"12070\" data-end=\"12082\"\u003e52 dB(A)\u003c\/strong\u003e, which remains reasonable, but the location should still be chosen carefully to respect neighbors and avoid vibrations.\u003c\/p\u003e\n\u003cp data-start=\"12222\" data-end=\"12534\"\u003eOn a balcony, backyard, side wall, or ground base, we check clearances, water drainage, snow, ice, vibrations, and future access for maintenance. An outdoor unit that is too low or poorly protected can be exposed to snow accumulation during the Quebec winter.\u003c\/p\u003e\n\u003ch2 data-start=\"12536\" data-end=\"12566\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12539\" data-end=\"12566\"\u003e1\/4 - 3\/8 inch piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12568\" data-end=\"12760\"\u003eThe ZE-09DB22 uses \u003cstrong data-start=\"12604\" data-end=\"12622\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"12626\" data-end=\"12640\"\u003e3\/8 inch gas\u003c\/strong\u003e piping. This configuration is very common for small wall-mounted heat pumps, but it must still be respected.\u003c\/p\u003e\n\u003cp data-start=\"12762\" data-end=\"13133\"\u003eWhen replacing an old machine, never assume existing lines are compatible. We check the diameter, line condition, type of old refrigerant, total length, and the possibility to reuse or replace the piping. \u003cstrong data-start=\"13032\" data-end=\"13133\"\u003eA poor line match can affect the device’s performance and reliability.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"13135\" data-end=\"13404\"\u003eThe brochure indicates a total piping length of \u003cstrong data-start=\"13192\" data-end=\"13209\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"13241\" data-end=\"13253\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"13293\" data-end=\"13305\"\u003e25 feet\u003c\/strong\u003e. This information is important to confirm project feasibility before installation.\u003c\/p\u003e\n\u003ch2 data-start=\"13406\" data-end=\"13441\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13409\" data-end=\"13441\"\u003e115V power supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13443\" data-end=\"13715\"\u003eOne interesting point of this model is its power supply of \u003cstrong data-start=\"13507\" data-end=\"13531\"\u003e115V, 60 Hz, 1 phase\u003c\/strong\u003e. For some projects, this can simplify planning compared to 208V \/ 230V models. However, this does not mean the device can be connected just any way.\u003c\/p\u003e\n\u003cp data-start=\"13717\" data-end=\"14020\"\u003eThe datasheet indicates a \u003cstrong data-start=\"13737\" data-end=\"13754\"\u003eMCA of 15.6 A\u003c\/strong\u003e and a \u003cstrong data-start=\"13761\" data-end=\"13776\"\u003eMOP of 20 A\u003c\/strong\u003e. Therefore, appropriate electrical protection must be planned and the available circuit verified. At AirGreen, we always validate the electrical panel, wire gauge, circuit breaker, electrical routing, and installation compliance.\u003c\/p\u003e\n\u003cp data-start=\"14022\" data-end=\"14241\"\u003eIn older homes in Montreal, Laval, or Longueuil, this check is especially important. A serious installation price must always take into account the actual condition of the electrical installation.\u003c\/p\u003e\n\u003ch2 data-start=\"14243\" data-end=\"14280\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14246\" data-end=\"14280\"\u003eBuilt-in comfort functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14282\" data-end=\"14414\"\u003eThe Zephyr ZE-09DB22 offers several practical features to enhance daily comfort. The brochure highlights in particular:\u003c\/p\u003e\n\u003cp data-start=\"14416\" data-end=\"15083\"\u003e• \u003cstrong data-start=\"14418\" data-end=\"14431\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"14431\" data-end=\"14434\"\u003e• \u003cstrong data-start=\"14436\" data-end=\"14452\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"14452\" data-end=\"14455\"\u003e• \u003cstrong data-start=\"14457\" data-end=\"14471\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"14471\" data-end=\"14474\"\u003e• \u003cstrong data-start=\"14476\" data-end=\"14496\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"14496\" data-end=\"14499\"\u003e• \u003cstrong data-start=\"14501\" data-end=\"14518\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"14518\" data-end=\"14521\"\u003e• \u003cstrong data-start=\"14523\" data-end=\"14545\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"14545\" data-end=\"14548\"\u003e• \u003cstrong data-start=\"14550\" data-end=\"14574\"\u003eBase heating\u003c\/strong\u003e\u003cbr data-start=\"14574\" data-end=\"14577\"\u003e• \u003cstrong data-start=\"14579\" data-end=\"14607\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"14607\" data-end=\"14610\"\u003e• \u003cstrong data-start=\"14612\" data-end=\"14654\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"14654\" data-end=\"14657\"\u003e• \u003cstrong data-start=\"14659\" data-end=\"14688\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"14688\" data-end=\"14691\"\u003e• \u003cstrong data-start=\"14693\" data-end=\"14720\"\u003eAutomatic oscillation\u003c\/strong\u003e\u003cbr data-start=\"14720\" data-end=\"14723\"\u003e• \u003cstrong data-start=\"14725\" data-end=\"14736\"\u003e4D mode\u003c\/strong\u003e\u003cbr data-start=\"14736\" data-end=\"14739\"\u003e• \u003cstrong data-start=\"14741\" data-end=\"14781\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"14781\" data-end=\"14784\"\u003e• \u003cstrong data-start=\"14786\" data-end=\"14815\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"14815\" data-end=\"14818\"\u003e• \u003cstrong data-start=\"14820\" data-end=\"14839\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"14839\" data-end=\"14842\"\u003e• \u003cstrong data-start=\"14844\" data-end=\"14876\"\u003eAutomatic 8 °C heating\u003c\/strong\u003e\u003cbr data-start=\"14876\" data-end=\"14879\"\u003e• \u003cstrong data-start=\"14881\" data-end=\"14909\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"14909\" data-end=\"14912\"\u003e• \u003cstrong data-start=\"14914\" data-end=\"14932\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"14932\" data-end=\"14935\"\u003e• \u003cstrong data-start=\"14937\" data-end=\"14962\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"14962\" data-end=\"14965\"\u003e• \u003cstrong data-start=\"14967\" data-end=\"14992\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"14992\" data-end=\"14995\"\u003e• \u003cstrong data-start=\"14997\" data-end=\"15033\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"15033\" data-end=\"15036\"\u003e• \u003cstrong data-start=\"15038\" data-end=\"15083\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"15085\" data-end=\"15462\"\u003eThe \u003cstrong data-start=\"15088\" data-end=\"15099\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"15105\" data-end=\"15132\"\u003eautomatic oscillation\u003c\/strong\u003e are particularly useful for better air distribution in the room. Good air distribution helps avoid cold or overly warm spots. For a bedroom or office, the \u003cstrong data-start=\"15327\" data-end=\"15343\"\u003esilent mode\u003c\/strong\u003e and \u003cstrong data-start=\"15350\" data-end=\"15363\"\u003enight mode\u003c\/strong\u003e can also be very appreciated, especially when the unit runs for several hours.\u003c\/p\u003e\n\u003cp data-start=\"15464\" data-end=\"15758\"\u003eThe \u003cstrong data-start=\"15467\" data-end=\"15481\"\u003eiFeel mode\u003c\/strong\u003e is also interesting because it helps the unit better adjust comfort based on the temperature sensed near the remote control. In a small room, this function can improve comfort accuracy, especially if the indoor unit is installed higher on the wall.\u003c\/p\u003e\n\u003ch2 data-start=\"15760\" data-end=\"15827\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15763\" data-end=\"15827\"\u003eInverter Comfort: Stability and Better Controlled Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15829\" data-end=\"16150\"\u003eThe brochure explains that variable frequency technology allows the heat pump to adjust its power in real time. This is an important point for comfort. Unlike a traditional unit that starts and stops abruptly, an \u003cstrong data-start=\"16088\" data-end=\"16100\"\u003eInverter\u003c\/strong\u003e heat pump can modulate its operation according to demand.\u003c\/p\u003e\n\u003cp data-start=\"16152\" data-end=\"16404\"\u003eIn practice, this helps reduce temperature fluctuations, improve comfort, and limit unnecessary cycles. Once the desired temperature is reached, the unit can operate more gently to maintain the indoor environment.\u003c\/p\u003e\n\u003cp data-start=\"16406\" data-end=\"16717\"\u003eFor a customer, this often translates to a more stable comfort feeling, less start-up noise, better humidity control in cooling, and more controlled consumption. \u003cstrong data-start=\"16607\" data-end=\"16717\"\u003eHowever, actual performance always depends on the quality of the installation and proper sizing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"16719\" data-end=\"16785\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16722\" data-end=\"16785\"\u003eHVAC Maintenance: Maintaining Performance Year After Year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16787\" data-end=\"16986\"\u003eA wall-mounted heat pump must be maintained to preserve its efficiency. Even though the Zephyr ZE-09DB22 has an \u003cstrong data-start=\"16916\" data-end=\"16941\"\u003eautomatic cleaning\u003c\/strong\u003e function, this does not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"16988\" data-end=\"17017\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"17019\" data-end=\"17468\"\u003e• \u003cstrong data-start=\"17021\" data-end=\"17059\"\u003eclean the filters regularly\u003c\/strong\u003e;\u003cbr data-start=\"17060\" data-end=\"17063\"\u003e• \u003cstrong data-start=\"17065\" data-end=\"17134\"\u003eensure air flows freely around the indoor unit\u003c\/strong\u003e;\u003cbr data-start=\"17135\" data-end=\"17138\"\u003e• \u003cstrong data-start=\"17140\" data-end=\"17178\"\u003einspect the condensation drain\u003c\/strong\u003e;\u003cbr data-start=\"17179\" data-end=\"17182\"\u003e• \u003cstrong data-start=\"17184\" data-end=\"17241\"\u003eavoid obstructing the unit with furniture or curtains\u003c\/strong\u003e;\u003cbr data-start=\"17242\" data-end=\"17245\"\u003e• \u003cstrong data-start=\"17247\" data-end=\"17323\"\u003ekeep the outdoor unit clear of leaves, dust, snow, and ice\u003c\/strong\u003e;\u003cbr data-start=\"17324\" data-end=\"17327\"\u003e• \u003cstrong data-start=\"17329\" data-end=\"17390\"\u003ehave the device checked if an unusual noise appears\u003c\/strong\u003e;\u003cbr data-start=\"17391\" data-end=\"17394\"\u003e• \u003cstrong data-start=\"17396\" data-end=\"17467\"\u003eschedule professional cleaning when the exchanger becomes dirty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17470\" data-end=\"17675\"\u003eA clean device heats better, cools better, consumes less, and lasts longer. At AirGreen, we always explain to customers the simple actions to take between professional maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"17677\" data-end=\"17742\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17680\" data-end=\"17742\"\u003eMistakes to avoid before buying a 9,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17744\" data-end=\"17887\"\u003eIn our experience, the most frequent mistakes do not always come from the chosen model, but rather from a poor project analysis.\u003c\/p\u003e\n\u003cp data-start=\"17889\" data-end=\"17917\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"17919\" data-end=\"18548\"\u003e• choosing a \u003cstrong data-start=\"17933\" data-end=\"17946\"\u003e9,000 BTU\u003c\/strong\u003e without checking the actual load;\u003cbr data-start=\"17978\" data-end=\"17981\"\u003e• installing the indoor unit in a corner where air circulation is poor;\u003cbr data-start=\"18046\" data-end=\"18049\"\u003e• neglecting outdoor noise in a dense area;\u003cbr data-start=\"18100\" data-end=\"18103\"\u003e• forgetting electrical verification despite the \u003cstrong data-start=\"18150\" data-end=\"18158\"\u003e115V\u003c\/strong\u003e;\u003cbr data-start=\"18159\" data-end=\"18162\"\u003e• assuming the old refrigerant lines are compatible;\u003cbr data-start=\"18229\" data-end=\"18232\"\u003e• installing the outdoor unit too close to the ground in snowy areas;\u003cbr data-start=\"18297\" data-end=\"18300\"\u003e• choosing the location just to hide the piping;\u003cbr data-start=\"18360\" data-end=\"18363\"\u003e• forgetting future access for maintenance;\u003cbr data-start=\"18404\" data-end=\"18407\"\u003e• comparing only the price without comparing installation quality;\u003cbr data-start=\"18476\" data-end=\"18479\"\u003e• ignoring the fact that this model is indicated as \u003cstrong data-start=\"18523\" data-end=\"18547\"\u003enon Energy Star V6.1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18550\" data-end=\"18726\"\u003eAt AirGreen, we clarify these points from the start. This helps avoid unpleasant surprises, unrealistic expectations, and costly adjustments after installation.\u003c\/p\u003e\n\u003ch2 data-start=\"18728\" data-end=\"18795\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18731\" data-end=\"18795\"\u003eWhy choose AirGreen to install the Zephyr ZE-09DB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18797\" data-end=\"19070\"\u003eAirGreen is a company specialized in \u003cstrong data-start=\"18840\" data-end=\"18848\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs wall-mounted, central, and multi-zone heat pumps in Greater Montreal. We regularly operate in \u003cstrong data-start=\"18991\" data-end=\"19069\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and in Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19072\" data-end=\"19122\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"19124\" data-end=\"19665\"\u003e• \u003cstrong data-start=\"19126\" data-end=\"19171\"\u003ea clear assessment before the work\u003c\/strong\u003e;\u003cbr data-start=\"19172\" data-end=\"19175\"\u003e• \u003cstrong data-start=\"19177\" data-end=\"19229\"\u003ea unit selected according to the actual building\u003c\/strong\u003e;\u003cbr data-start=\"19230\" data-end=\"19233\"\u003e• \u003cstrong data-start=\"19235\" data-end=\"19291\"\u003einstallation compliant with technical requirements\u003c\/strong\u003e;\u003cbr data-start=\"19292\" data-end=\"19295\"\u003e• \u003cstrong data-start=\"19297\" data-end=\"19365\"\u003ea thorough check of electricity and piping\u003c\/strong\u003e;\u003cbr data-start=\"19366\" data-end=\"19369\"\u003e• \u003cstrong data-start=\"19371\" data-end=\"19428\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"19429\" data-end=\"19432\"\u003e• \u003cstrong data-start=\"19434\" data-end=\"19472\"\u003estructured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"19473\" data-end=\"19476\"\u003e• \u003cstrong data-start=\"19478\" data-end=\"19566\"\u003ea team experienced with installations in condos, houses, plexes, and small businesses\u003c\/strong\u003e;\u003cbr data-start=\"19567\" data-end=\"19570\"\u003e• \u003cstrong data-start=\"19572\" data-end=\"19664\"\u003esupport to understand warranties, maintenance, and system limitations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19667\" data-end=\"19977\"\u003eWe know that a heat pump is a significant investment, even when it is a compact model. Our goal is for the customer to fully understand what they are buying, why this model is recommended, how it will be installed, and how it should be used to deliver its best performance.\u003c\/p\u003e\n\u003ch2 data-start=\"19979\" data-end=\"20055\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19982\" data-end=\"20055\"\u003eA compact, reliable HVAC solution well suited to targeted rooms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"20057\" data-end=\"20532\"\u003eThe \u003cstrong data-start=\"20060\" data-end=\"20118\"\u003eZephyr ZE-09DB22 R32 9,000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e is an interesting solution for customers looking for a compact, practical device capable of heating down to \u003cstrong data-start=\"20243\" data-end=\"20253\"\u003e-25 °C\u003c\/strong\u003e. With its \u003cstrong data-start=\"20264\" data-end=\"20283\"\u003eR32 refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"20289\" data-end=\"20306\"\u003eSEER2 of 20.0\u003c\/strong\u003e, air flow of \u003cstrong data-start=\"20327\" data-end=\"20344\"\u003e253 to 400 CFM\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"20400\" data-end=\"20412\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, and built-in comfort features, it meets the needs of many residential rooms.\u003c\/p\u003e\n\u003cp data-start=\"20534\" data-end=\"20799\"\u003eHowever, it requires careful installation. The \u003cstrong data-start=\"20597\" data-end=\"20613\"\u003e1\/4 - 3\/8 inch\u003c\/strong\u003e piping, \u003cstrong data-start=\"20630\" data-end=\"20638\"\u003e115V\u003c\/strong\u003e power supply, \u003cstrong data-start=\"20643\" data-end=\"20660\"\u003e15.6 A MCA\u003c\/strong\u003e, \u003cstrong data-start=\"20665\" data-end=\"20680\"\u003e20 A MOP\u003c\/strong\u003e, outdoor clearances, drainage, and wall positioning must be verified before confirming the project.\u003c\/p\u003e\n\u003cp data-start=\"20801\" data-end=\"21189\"\u003eTo get a clear quote, check if this model suits your room, compare the Zephyr ZE-09DB22 with other wall-mounted heat pumps, or plan an installation in \u003cstrong data-start=\"20979\" data-end=\"21042\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact \u003cstrong data-start=\"21054\" data-end=\"21066\"\u003eAirGreen\u003c\/strong\u003e. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925226788,"sku":"ZE-09DB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL.png?v=1783356981","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-cb22-r32-9000-btu-115v","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}