{"product_id":"thermopompe-murale-zephyr-cb22-r32-9000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 9000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"133\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"133\"\u003eZephyr CB22 R32 ZE-09CB22 Wall-Mounted Heat Pump: a compact, efficient 9,000 BTU solution well suited for residential comfort\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"135\" data-end=\"705\"\u003eThe \u003cstrong data-start=\"138\" data-end=\"186\"\u003eZephyr CB22 R32 ZE-09CB22 Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at homeowners looking for a simple, reliable, and efficient HVAC solution to cool and heat a specific area of their home, condo, office, or small commercial space. With its \u003cstrong data-start=\"402\" data-end=\"415\"\u003e9,000 BTU\u003c\/strong\u003e capacity, operation with \u003cstrong data-start=\"439\" data-end=\"458\"\u003eR32 refrigerant\u003c\/strong\u003e, efficiency of \u003cstrong data-start=\"477\" data-end=\"491\"\u003e22.5 SEER2\u003c\/strong\u003e, and heating capacity down to \u003cstrong data-start=\"528\" data-end=\"538\"\u003e-25 °C\u003c\/strong\u003e, this model represents an interesting option for projects seeking a good balance between comfort, energy efficiency, and reasonable installation cost.\u003c\/p\u003e\n\u003cp data-start=\"707\" data-end=\"1225\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the need is well targeted: a master bedroom, a home office, a small living room, a room above a garage, a well-insulated condo, or an area that remains uncomfortable despite existing heating or cooling. The model \u003cstrong data-start=\"1017\" data-end=\"1030\"\u003eZE-09CB22\u003c\/strong\u003e is not designed to replace a large 18,000 or 24,000 BTU heat pump in a large open area, but it can deliver excellent results when installed in the right context.\u003c\/p\u003e\n\u003cp data-start=\"1227\" data-end=\"1812\"\u003eThe Zephyr CB22 brochure highlights a wall-mounted heat pump with \u003cstrong data-start=\"1290\" data-end=\"1297\"\u003eR32\u003c\/strong\u003e, featuring \u003cstrong data-start=\"1304\" data-end=\"1332\"\u003eheating down to -25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1334\" data-end=\"1366\"\u003ecooling down to -15 °C\u003c\/strong\u003e, variable frequency technology, silent mode, night mode, iFeel mode, quick start, 24-hour timer, automatic oscillation, 4D mode, and a basic warranty of \u003cstrong data-start=\"1529\" data-end=\"1546\"\u003e10 years on parts\u003c\/strong\u003e. For the model \u003cstrong data-start=\"1563\" data-end=\"1576\"\u003eZE-09CB22\u003c\/strong\u003e, the technical sheet notably indicates \u003cstrong data-start=\"1615\" data-end=\"1647\"\u003e9,000 BTU cooling capacity\u003c\/strong\u003e, \u003cstrong data-start=\"1649\" data-end=\"1663\"\u003e22.5 SEER2\u003c\/strong\u003e, \u003cstrong data-start=\"1665\" data-end=\"1676\"\u003e9 HSPF2\u003c\/strong\u003e, \u003cstrong data-start=\"1678\" data-end=\"1698\"\u003eEnergy Star V6.1\u003c\/strong\u003e, a power supply of \u003cstrong data-start=\"1717\" data-end=\"1730\"\u003e208\/230 V\u003c\/strong\u003e, a \u003cstrong data-start=\"1735\" data-end=\"1750\"\u003e15 A MOP\u003c\/strong\u003e, and a \u003cstrong data-start=\"1757\" data-end=\"1773\"\u003e9.5 A MCA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-start=\"1814\" data-end=\"1875\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1816\" data-end=\"1875\"\u003eImportant technical features to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"1877\" data-end=\"1968\"\u003eFor the model \u003cstrong data-start=\"1892\" data-end=\"1917\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e, the main information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"3360\"\u003e• \u003cstrong data-start=\"1972\" data-end=\"1991\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"1991\" data-end=\"1994\"\u003e• \u003cstrong data-start=\"1996\" data-end=\"2012\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e• \u003cstrong data-start=\"2017\" data-end=\"2046\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2046\" data-end=\"2049\"\u003e• \u003cstrong data-start=\"2051\" data-end=\"2073\"\u003eModel: ZE-09CB22\u003c\/strong\u003e\u003cbr data-start=\"2073\" data-end=\"2076\"\u003e• \u003cstrong data-start=\"2078\" data-end=\"2131\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2131\" data-end=\"2134\"\u003e• \u003cstrong data-start=\"2136\" data-end=\"2184\"\u003eHeating capacity at 8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2184\" data-end=\"2187\"\u003e• \u003cstrong data-start=\"2189\" data-end=\"2205\"\u003eSEER2: 22.5\u003c\/strong\u003e\u003cbr data-start=\"2205\" data-end=\"2208\"\u003e• \u003cstrong data-start=\"2210\" data-end=\"2226\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2226\" data-end=\"2229\"\u003e• \u003cstrong data-start=\"2231\" data-end=\"2252\"\u003eEER2: 12.5 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2252\" data-end=\"2255\"\u003e• \u003cstrong data-start=\"2257\" data-end=\"2289\"\u003eHeating COP at 8.3 °C: 3.9\u003c\/strong\u003e\u003cbr data-start=\"2289\" data-end=\"2292\"\u003e• \u003cstrong data-start=\"2294\" data-end=\"2325\"\u003eCOP2 heating: 13.4 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2325\" data-end=\"2328\"\u003e• \u003cstrong data-start=\"2330\" data-end=\"2388\"\u003eNominal heating capacity at -8.3 °C: 6,500 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003e• \u003cstrong data-start=\"2393\" data-end=\"2450\"\u003eMaximum heating capacity at -15 °C: 5,400 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2450\" data-end=\"2453\"\u003e• \u003cstrong data-start=\"2455\" data-end=\"2477\"\u003eCOP at -15 °C: 2.1\u003c\/strong\u003e\u003cbr data-start=\"2477\" data-end=\"2480\"\u003e• \u003cstrong data-start=\"2482\" data-end=\"2539\"\u003eMaximum heating capacity at -20 °C: 4,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003e• \u003cstrong data-start=\"2544\" data-end=\"2570\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"2570\" data-end=\"2573\"\u003e• \u003cstrong data-start=\"2575\" data-end=\"2596\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2596\" data-end=\"2599\"\u003e• \u003cstrong data-start=\"2601\" data-end=\"2637\"\u003eRefrigerant charge: 21.52 oz\u003c\/strong\u003e\u003cbr data-start=\"2637\" data-end=\"2640\"\u003e• \u003cstrong data-start=\"2642\" data-end=\"2673\"\u003eAirflow: 218 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"2673\" data-end=\"2676\"\u003e• \u003cstrong data-start=\"2678\" data-end=\"2743\"\u003eIndoor sound pressure: 45 \/ 40 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2743\" data-end=\"2746\"\u003e• \u003cstrong data-start=\"2748\" data-end=\"2793\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2793\" data-end=\"2796\"\u003e• \u003cstrong data-start=\"2798\" data-end=\"2837\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"2837\" data-end=\"2840\"\u003e• \u003cstrong data-start=\"2842\" data-end=\"2888\"\u003eNominal cooling current: 3.4 A\u003c\/strong\u003e\u003cbr data-start=\"2888\" data-end=\"2891\"\u003e• \u003cstrong data-start=\"2893\" data-end=\"2933\"\u003eNominal heating current: 3.1 A\u003c\/strong\u003e\u003cbr data-start=\"2933\" data-end=\"2936\"\u003e• \u003cstrong data-start=\"2938\" data-end=\"2953\"\u003eMCA: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"2953\" data-end=\"2956\"\u003e• \u003cstrong data-start=\"2958\" data-end=\"2972\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"2972\" data-end=\"2975\"\u003e• \u003cstrong data-start=\"2977\" data-end=\"3041\"\u003eRequired communication wire: 4\/14 copper multistrand 600 V\u003c\/strong\u003e\u003cbr data-start=\"3041\" data-end=\"3044\"\u003e• \u003cstrong data-start=\"3046\" data-end=\"3077\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3077\" data-end=\"3080\"\u003e• \u003cstrong data-start=\"3082\" data-end=\"3109\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3109\" data-end=\"3112\"\u003e• \u003cstrong data-start=\"3114\" data-end=\"3164\"\u003eMinimum-maximum piping length: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3164\" data-end=\"3167\"\u003e• \u003cstrong data-start=\"3169\" data-end=\"3206\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3206\" data-end=\"3209\"\u003e• \u003cstrong data-start=\"3211\" data-end=\"3247\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3247\" data-end=\"3250\"\u003e• \u003cstrong data-start=\"3252\" data-end=\"3295\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"3295\" data-end=\"3298\"\u003e• \u003cstrong data-start=\"3300\" data-end=\"3360\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3362\" data-end=\"3552\"\u003eThe dimensions indicated in the technical sheet are in \u003cstrong data-start=\"3426\" data-end=\"3439\"\u003eL × H × D\u003c\/strong\u003e format. To facilitate reading during an installation project, we can present them in \u003cstrong data-start=\"3537\" data-end=\"3550\"\u003eL × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3554\" data-end=\"3653\"\u003e• \u003cstrong data-start=\"3556\" data-end=\"3602\"\u003eIndoor unit: 33.44 × 8.06 × 11.56 in\u003c\/strong\u003e\u003cbr data-start=\"3602\" data-end=\"3605\"\u003e• \u003cstrong data-start=\"3607\" data-end=\"3653\"\u003eOutdoor unit: 28.13 × 9.50 × 21.25 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3655\" data-end=\"3962\"\u003eThese dimensions are especially interesting for projects where wall space is limited. An indoor unit about \u003cstrong data-start=\"3784\" data-end=\"3807\"\u003e33.44 in wide\u003c\/strong\u003e and \u003cstrong data-start=\"3811\" data-end=\"3834\"\u003e11.56 in high\u003c\/strong\u003e can fit more easily in a bedroom, office, or condo than a wider wall unit of 18,000 or 24,000 BTU.\u003c\/p\u003e\n\u003ch1 data-start=\"3964\" data-end=\"4033\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3966\" data-end=\"4033\"\u003eA 9,000 BTU wall-mounted heat pump designed for targeted spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"4035\" data-end=\"4447\"\u003eThe \u003cstrong data-start=\"4038\" data-end=\"4058\"\u003eZephyr ZE-09CB22\u003c\/strong\u003e is a \u003cstrong data-start=\"4082\" data-end=\"4095\"\u003e9,000 BTU\u003c\/strong\u003e heat pump, making it particularly suitable for small to medium-sized spaces. In reality, the BTU number should never be used alone to choose a device. Insulation, sun exposure, ceiling height, number of windows, air circulation, and actual room use must also be considered.\u003c\/p\u003e\n\u003cp data-start=\"4449\" data-end=\"4870\"\u003eIn a house in Laval, this model can be very suitable for a master bedroom or a closed office. In a condo in Montreal, it can be used for a compact living area or a room that overheats in summer. In Longueuil, on the South Shore or the North Shore, it can also help improve comfort in a specific area that is not well served by the main heating or cooling system.\u003c\/p\u003e\n\u003cp data-start=\"4872\" data-end=\"5421\"\u003e\u003cstrong data-start=\"4872\" data-end=\"4913\"\u003eProper sizing is essential.\u003c\/strong\u003e An oversized heat pump can reach the desired temperature too quickly without properly dehumidifying the air in summer. The result can be a damp cold feeling or uneven comfort. Conversely, an undersized heat pump will run almost continuously and may struggle on very hot or very cold days. The \u003cstrong data-start=\"5283\" data-end=\"5296\"\u003eZE-09CB22\u003c\/strong\u003e model should therefore be selected based on a real analysis of the building, not just a quick estimate of the area.\u003c\/p\u003e\n\u003ch1 data-start=\"5423\" data-end=\"5469\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5425\" data-end=\"5469\"\u003eR32: a modern and efficient refrigerant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"5471\" data-end=\"5797\"\u003eThe \u003cstrong data-start=\"5474\" data-end=\"5499\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e operates with \u003cstrong data-start=\"5514\" data-end=\"5533\"\u003eR32 refrigerant\u003c\/strong\u003e, a gas used in several modern wall-mounted heat pumps. For the customer, this detail may seem very technical, but it is important because the refrigerant influences the unit’s design, installation practices, and commissioning requirements.\u003c\/p\u003e\n\u003cp data-start=\"5799\" data-end=\"6133\"\u003eWith a charge of \u003cstrong data-start=\"5818\" data-end=\"5830\"\u003e21.52 oz\u003c\/strong\u003e, the model \u003cstrong data-start=\"5842\" data-end=\"5855\"\u003eZE-09CB22\u003c\/strong\u003e must be installed carefully. Steps like flaring, leak testing, vacuuming, checking pipe length, and commissioning must not be overlooked. \u003cstrong data-start=\"6058\" data-end=\"6133\"\u003eA modern heat pump does not forgive a sloppy installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6135\" data-end=\"6448\"\u003eAt AirGreen, we always take the time to validate the piping route, wall condition, drainage, outdoor clearances, and electrical compliance before confirming an installation. This approach helps avoid performance, noise, leakage, or long-term reliability issues.\u003c\/p\u003e\n\u003ch1 data-start=\"6450\" data-end=\"6506\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6452\" data-end=\"6506\"\u003eEnergy efficiency: 22.5 SEER2 and Energy Star\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"6508\" data-end=\"6817\"\u003eThe model \u003cstrong data-start=\"6518\" data-end=\"6531\"\u003eZE-09CB22\u003c\/strong\u003e shows a performance of \u003cstrong data-start=\"6556\" data-end=\"6570\"\u003e22.5 SEER2\u003c\/strong\u003e, which is an excellent indicator of cooling efficiency. SEER2 measures seasonal cooling efficiency. The higher the value, the more effectively the unit can produce cooling over an entire season.\u003c\/p\u003e\n\u003cp data-start=\"6819\" data-end=\"7218\"\u003eThis model is also rated \u003cstrong data-start=\"6851\" data-end=\"6877\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e, which adds an important point for owners who want to choose a more efficient unit. For a bedroom, office, or small regularly used space, an efficient heat pump can help reduce energy consumption, especially if it replaces electric baseboards or a less efficient air conditioner.\u003c\/p\u003e\n\u003cp data-start=\"7220\" data-end=\"7582\"\u003eThe \u003cstrong data-start=\"7223\" data-end=\"7237\"\u003eHSPF2 of 9\u003c\/strong\u003e gives an indication of heating efficiency. The \u003cstrong data-start=\"7293\" data-end=\"7316\"\u003eCOP of 3.9 at 8.3 °C\u003c\/strong\u003e means the unit can produce much more thermal energy than it consumes in electricity under favorable conditions. However, as with all heat pumps, the available capacity decreases when the outside temperature drops significantly.\u003c\/p\u003e\n\u003cp data-start=\"7584\" data-end=\"7834\"\u003eAt AirGreen, we always explain these figures in concrete terms. The goal is not for the customer to memorize every indicator, but to understand that \u003cstrong data-start=\"7744\" data-end=\"7833\"\u003eefficiency depends as much on the product as on the installation and proper sizing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-start=\"7836\" data-end=\"7902\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7838\" data-end=\"7902\"\u003eHeating down to -25 °C: what you really need to understand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"7904\" data-end=\"8213\"\u003eThe Zephyr CB22 brochure presents the series as a heat pump capable of heating down to \u003cstrong data-start=\"7996\" data-end=\"8006\"\u003e-25 °C\u003c\/strong\u003e. This is an important advantage for Quebec winters, especially for customers in Montreal, Laval, Longueuil, the South Shore, and the North Shore who want to use their heat pump for much of the year.\u003c\/p\u003e\n\u003cp data-start=\"8215\" data-end=\"8273\"\u003eFor the \u003cstrong data-start=\"8230\" data-end=\"8243\"\u003eZE-09CB22\u003c\/strong\u003e model, the technical sheet indicates:\u003c\/p\u003e\n\u003cp data-start=\"8275\" data-end=\"8402\"\u003e• \u003cstrong data-start=\"8277\" data-end=\"8314\"\u003e9,000 BTU\/h heating at 8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"8314\" data-end=\"8317\"\u003e• \u003cstrong data-start=\"8319\" data-end=\"8344\"\u003e6,500 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"8344\" data-end=\"8347\"\u003e• \u003cstrong data-start=\"8349\" data-end=\"8373\"\u003e5,400 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"8373\" data-end=\"8376\"\u003e• \u003cstrong data-start=\"8378\" data-end=\"8402\"\u003e4,000 BTU\/h at -20 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"8404\" data-end=\"8723\"\u003eThese figures are very important. They show that the model can continue to operate in cold weather, but capacity decreases as the temperature drops. \u003cstrong data-start=\"8572\" data-end=\"8656\"\u003eHeating down to -25 °C does not mean producing 9,000 BTU continuously at -25 °C.\u003c\/strong\u003e This is an essential distinction to avoid unrealistic expectations.\u003c\/p\u003e\n\u003cp data-start=\"8725\" data-end=\"9055\"\u003eIn a well-insulated room, this model can provide very good comfort for much of the winter. In an older, poorly insulated, heavily windowed, or wind-exposed room, supplementary heating may still be necessary on the coldest days. Our role is to clearly explain this reality before installation.\u003c\/p\u003e\n\u003ch1 data-start=\"9057\" data-end=\"9135\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9059\" data-end=\"9135\"\u003e4D Mode and Automatic Oscillation: Better Air Distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"9137\" data-end=\"9414\"\u003eThe brochure highlights the \u003cstrong data-start=\"9165\" data-end=\"9176\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9182\" data-end=\"9209\"\u003eautomatic oscillation\u003c\/strong\u003e, two important features to improve air distribution in the room. The goal is to limit cold or hot spots and help the device maintain a more balanced temperature.\u003c\/p\u003e\n\u003cp data-start=\"9416\" data-end=\"9713\"\u003eIn a bedroom, poor positioning can create a direct draft toward the bed. In an office, this can become uncomfortable during working hours. In a small living room, poor diffusion can cool one part of the room while leaving another area too warm.\u003c\/p\u003e\n\u003cp data-start=\"9715\" data-end=\"10144\"\u003eThe \u003cstrong data-start=\"9718\" data-end=\"9729\"\u003e4D mode\u003c\/strong\u003e helps to direct the air more completely, but it does not replace good planning. \u003cstrong data-start=\"9824\" data-end=\"9930\"\u003eThe location of the indoor unit remains one of the most important factors for final comfort.\u003c\/strong\u003e At AirGreen, we always assess the available walls, natural air circulation, furniture placement, ceiling height, and piping constraints before proposing the final location.\u003c\/p\u003e\n\u003ch1 data-start=\"10146\" data-end=\"10197\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10148\" data-end=\"10197\"\u003eInverter technology: more stable comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"10199\" data-end=\"10436\"\u003eVariable frequency technology, also called \u003cstrong data-start=\"10250\" data-end=\"10262\"\u003eInverter\u003c\/strong\u003e, allows the heat pump to adjust its power in real time. Instead of operating only on an on-off basis, the device modulates its effort according to the room’s needs.\u003c\/p\u003e\n\u003cp data-start=\"10438\" data-end=\"10717\"\u003eThis helps reduce temperature fluctuations, improve comfort, and limit energy consumption. A heat pump that runs more gently over long periods can often provide better comfort than a device that constantly starts and stops.\u003c\/p\u003e\n\u003cp data-start=\"10719\" data-end=\"11051\"\u003eFor a model like the \u003cstrong data-start=\"10743\" data-end=\"10756\"\u003eZE-09CB22\u003c\/strong\u003e, this technology is especially useful in rooms where a stable temperature is desired: bedroom, office, playroom, family room, or condo. \u003cstrong data-start=\"10920\" data-end=\"11051\"\u003eComfort comes not only from BTU power but from the device’s ability to maintain a consistent atmosphere.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"11053\" data-end=\"11096\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11055\" data-end=\"11096\"\u003eConvenient features for everyday use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"11098\" data-end=\"11210\"\u003eThe Zephyr CB22 series offers several features designed to make daily use of the device easier:\u003c\/p\u003e\n\u003cp data-start=\"11212\" data-end=\"11846\"\u003e• \u003cstrong data-start=\"11214\" data-end=\"11227\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"11227\" data-end=\"11230\"\u003e• \u003cstrong data-start=\"11232\" data-end=\"11248\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"11248\" data-end=\"11251\"\u003e• \u003cstrong data-start=\"11253\" data-end=\"11267\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"11267\" data-end=\"11270\"\u003e• \u003cstrong data-start=\"11272\" data-end=\"11292\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"11292\" data-end=\"11295\"\u003e• \u003cstrong data-start=\"11297\" data-end=\"11315\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"11315\" data-end=\"11318\"\u003e• \u003cstrong data-start=\"11320\" data-end=\"11338\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"11338\" data-end=\"11341\"\u003e• \u003cstrong data-start=\"11343\" data-end=\"11372\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"11372\" data-end=\"11375\"\u003e• \u003cstrong data-start=\"11377\" data-end=\"11396\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"11396\" data-end=\"11399\"\u003e• \u003cstrong data-start=\"11401\" data-end=\"11441\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"11441\" data-end=\"11444\"\u003e• \u003cstrong data-start=\"11446\" data-end=\"11482\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"11482\" data-end=\"11485\"\u003e• \u003cstrong data-start=\"11487\" data-end=\"11512\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"11512\" data-end=\"11515\"\u003e• \u003cstrong data-start=\"11517\" data-end=\"11542\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"11542\" data-end=\"11545\"\u003e• \u003cstrong data-start=\"11547\" data-end=\"11585\"\u003eAutomatic 8 °C \/ 46 °F heating\u003c\/strong\u003e\u003cbr data-start=\"11585\" data-end=\"11588\"\u003e• \u003cstrong data-start=\"11590\" data-end=\"11618\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"11618\" data-end=\"11621\"\u003e• \u003cstrong data-start=\"11623\" data-end=\"11645\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"11645\" data-end=\"11648\"\u003e• \u003cstrong data-start=\"11650\" data-end=\"11679\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"11679\" data-end=\"11682\"\u003e• \u003cstrong data-start=\"11684\" data-end=\"11726\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"11726\" data-end=\"11729\"\u003e• \u003cstrong data-start=\"11731\" data-end=\"11759\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"11759\" data-end=\"11762\"\u003e• \u003cstrong data-start=\"11764\" data-end=\"11796\"\u003eOutdoor unit heating\u003c\/strong\u003e\u003cbr data-start=\"11796\" data-end=\"11799\"\u003e• \u003cstrong data-start=\"11801\" data-end=\"11846\"\u003eHeated chassis for the outdoor unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"11848\" data-end=\"12089\"\u003eThe \u003cstrong data-start=\"11851\" data-end=\"11867\"\u003esilent mode\u003c\/strong\u003e is particularly interesting for a bedroom or office. The indoor noise level can drop to \u003cstrong data-start=\"11982\" data-end=\"11994\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, allowing discreet use during the night or while working.\u003c\/p\u003e\n\u003cp data-start=\"12091\" data-end=\"12392\"\u003eThe \u003cstrong data-start=\"12094\" data-end=\"12108\"\u003eiFeel mode\u003c\/strong\u003e can also improve comfort, as it allows the unit to better adjust its operation according to the temperature sensed around the remote control. This is useful when the temperature near the wall unit does not perfectly reflect the actual temperature in the occupied area.\u003c\/p\u003e\n\u003cp data-start=\"12394\" data-end=\"12735\"\u003eThe \u003cstrong data-start=\"12397\" data-end=\"12422\"\u003eautomatic defrost\u003c\/strong\u003e, \u003cstrong data-start=\"12427\" data-end=\"12455\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"12462\" data-end=\"12493\"\u003eoutdoor heated chassis\u003c\/strong\u003e are also relevant features for Quebec. An outdoor unit must withstand cold, snow, ice, and humidity. These features can help, but they must be accompanied by a well-thought-out outdoor installation.\u003c\/p\u003e\n\u003ch1 data-start=\"12737\" data-end=\"12802\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12739\" data-end=\"12802\"\u003eElectrical installation: a 208\/230 V model with 15 A MOP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"12804\" data-end=\"13053\"\u003eThe \u003cstrong data-start=\"12814\" data-end=\"12827\"\u003eZE-09CB22\u003c\/strong\u003e model operates on \u003cstrong data-start=\"12842\" data-end=\"12871\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e. The label indicates a \u003cstrong data-start=\"12893\" data-end=\"12909\"\u003eMCA of 9.5 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12916\" data-end=\"12931\"\u003eMOP of 15 A\u003c\/strong\u003e. This information is essential before confirming the project, as it determines the type of electrical circuit required.\u003c\/p\u003e\n\u003cp data-start=\"13055\" data-end=\"13324\"\u003eEven if the unit is a 9,000 BTU heat pump, the electrical part should never be taken lightly. The panel must have enough space, the breaker must be appropriate, the wiring must meet requirements, and the electrical route must be properly planned.\u003c\/p\u003e\n\u003cp data-start=\"13326\" data-end=\"13640\"\u003eIn some older homes in Montreal or Longueuil, the electrical panel may already be fully loaded. In some condos, adding a circuit may require additional verification. At AirGreen, we check these elements before installation to avoid surprises on the day of the work.\u003c\/p\u003e\n\u003ch1 data-start=\"13642\" data-end=\"13709\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13644\" data-end=\"13709\"\u003e1\/4 - 3\/8 inch piping: a crucial detail in replacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"13711\" data-end=\"13959\"\u003eThe \u003cstrong data-start=\"13714\" data-end=\"13734\"\u003eZephyr ZE-09CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"13761\" data-end=\"13787\"\u003e1\/4 inch piping for the liquid\u003c\/strong\u003e and \u003cstrong data-start=\"13791\" data-end=\"13813\"\u003e3\/8 inch piping for the gas\u003c\/strong\u003e. This information is especially important when a customer wants to replace an old heat pump by reusing the existing lines.\u003c\/p\u003e\n\u003cp data-start=\"13961\" data-end=\"14203\"\u003eYou should never assume that the old piping is compatible. You need to check the diameter, the condition of the lines, the old refrigerant used, the length of the run, accessibility, and the possibility of properly replacing the lines.\u003c\/p\u003e\n\u003cp data-start=\"14205\" data-end=\"14540\"\u003eThe technical sheet indicates a piping length of \u003cstrong data-start=\"14262\" data-end=\"14279\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation difference of \u003cstrong data-start=\"14311\" data-end=\"14323\"\u003e50 feet\u003c\/strong\u003e, and a precharge for \u003cstrong data-start=\"14346\" data-end=\"14358\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected to ensure good performance. \u003cstrong data-start=\"14432\" data-end=\"14540\"\u003eImproperly adapted piping can harm efficiency, noise level, reliability, and warranty.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"14542\" data-end=\"14608\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14544\" data-end=\"14608\"\u003eNoise level: a discreet unit for occupied rooms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"14610\" data-end=\"14877\"\u003eThe indoor sound pressure level indicated for the \u003cstrong data-start=\"14668\" data-end=\"14681\"\u003eZE-09CB22\u003c\/strong\u003e model is \u003cstrong data-start=\"14689\" data-end=\"14721\"\u003e45 \/ 40 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on the selected speed. This makes it a unit well suited for spaces where silence is important, such as a bedroom, office, or break room.\u003c\/p\u003e\n\u003cp data-start=\"14879\" data-end=\"15244\"\u003eThe outdoor unit is rated at \u003cstrong data-start=\"14913\" data-end=\"14925\"\u003e53 dB(A)\u003c\/strong\u003e. This level remains reasonable, but the outdoor location must be chosen carefully. In the city, sound can reflect off walls, balconies, fences, or narrow passages. A unit installed too close to a window, a neighbor, or a closed corner may seem louder than it actually is.\u003c\/p\u003e\n\u003cp data-start=\"15246\" data-end=\"15498\"\u003eAt AirGreen, we consider noise, but also maintenance access, drainage, snow, ice, and the stability of the outdoor base. \u003cstrong data-start=\"15407\" data-end=\"15498\"\u003eA good outdoor location protects both comfort and the durability of the unit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"15500\" data-end=\"15588\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15502\" data-end=\"15588\"\u003eOperating range: air conditioning down to -15 °C and heating down to -25 °C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"15590\" data-end=\"15850\"\u003eThe brochure indicates an operating range for air conditioning from \u003cstrong data-start=\"15658\" data-end=\"15676\"\u003e-15 °C to 48 °C\u003c\/strong\u003e and for heating from \u003cstrong data-start=\"15696\" data-end=\"15714\"\u003e-25 °C to 24 °C\u003c\/strong\u003e. For Quebec, these figures are relevant because they show that the unit can operate in a wide variety of conditions.\u003c\/p\u003e\n\u003cp data-start=\"15852\" data-end=\"16201\"\u003eAir conditioning down to \u003cstrong data-start=\"15877\" data-end=\"15887\"\u003e-15 °C\u003c\/strong\u003e can be useful for certain specific uses, such as technical rooms or spaces that need cooling even when the outside temperature is cool. For typical residential use, it is mainly the heating capacity down to \u003cstrong data-start=\"16158\" data-end=\"16168\"\u003e-25 °C\u003c\/strong\u003e that interests homeowners.\u003c\/p\u003e\n\u003cp data-start=\"16203\" data-end=\"16512\"\u003eHowever, it is important to keep a realistic view: \u003cstrong data-start=\"16250\" data-end=\"16365\"\u003ethe operating range indicates the limits of operation, not constant capacity at all temperatures\u003c\/strong\u003e. That is why heating data at -8.3 °C, -15 °C, and -20 °C are important to understand the actual behavior of the device in winter.\u003c\/p\u003e\n\u003ch1 data-start=\"16514\" data-end=\"16576\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16516\" data-end=\"16576\"\u003eHVAC maintenance: preserving efficiency and durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"16578\" data-end=\"16803\"\u003eA wall-mounted heat pump like the \u003cstrong data-start=\"16610\" data-end=\"16635\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e must be well maintained to retain its efficiency. Features like automatic cleaning can help, but they do not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"16805\" data-end=\"16834\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"16836\" data-end=\"17284\"\u003e• clean the filters frequently;\u003cbr data-start=\"16871\" data-end=\"16874\"\u003e• ensure the condensation drain flows properly;\u003cbr data-start=\"16933\" data-end=\"16936\"\u003e• keep the indoor unit clean;\u003cbr data-start=\"16971\" data-end=\"16974\"\u003e• monitor for unusual odors or noises;\u003cbr data-start=\"17020\" data-end=\"17023\"\u003e• clear the outdoor unit of snow, leaves, and debris;\u003cbr data-start=\"17092\" data-end=\"17095\"\u003e• check the condition of the outdoor base after winter;\u003cbr data-start=\"17149\" data-end=\"17152\"\u003e• request professional cleaning when performance decreases;\u003cbr data-start=\"17221\" data-end=\"17224\"\u003e• have the unit inspected if defrosting seems abnormal.\u003c\/p\u003e\n\u003cp data-start=\"17286\" data-end=\"17453\"\u003eProper maintenance helps preserve \u003cstrong data-start=\"17327\" data-end=\"17355\"\u003eenergy efficiency\u003c\/strong\u003e, \u003cstrong data-start=\"17357\" data-end=\"17371\"\u003ecomfort\u003c\/strong\u003e, \u003cstrong data-start=\"17373\" data-end=\"17393\"\u003eair quality\u003c\/strong\u003e, \u003cstrong data-start=\"17395\" data-end=\"17415\"\u003enoise level\u003c\/strong\u003e, and \u003cstrong data-start=\"17419\" data-end=\"17438\"\u003ethe lifespan\u003c\/strong\u003e of the device.\u003c\/p\u003e\n\u003ch1 data-start=\"17455\" data-end=\"17519\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17457\" data-end=\"17519\"\u003eMistakes to avoid before buying a 9,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"17521\" data-end=\"17681\"\u003eIn our experience, the most frequent mistakes rarely come from a single technical figure. They usually come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"17683\" data-end=\"17711\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"17713\" data-end=\"18254\"\u003e• choosing a 9,000 BTU unit solely based on area;\u003cbr data-start=\"17768\" data-end=\"17771\"\u003e• ignoring window orientation;\u003cbr data-start=\"17808\" data-end=\"17811\"\u003e• neglecting insulation;\u003cbr data-start=\"17834\" data-end=\"17837\"\u003e• forgetting the ceiling height;\u003cbr data-start=\"17869\" data-end=\"17872\"\u003e• placing the indoor unit only to hide the piping;\u003cbr data-start=\"17936\" data-end=\"17939\"\u003e• blowing air directly towards the bed, sofa, or desk;\u003cbr data-start=\"17996\" data-end=\"17999\"\u003e• assuming the old refrigerant lines are compatible;\u003cbr data-start=\"18066\" data-end=\"18069\"\u003e• forgetting electrical verification;\u003cbr data-start=\"18106\" data-end=\"18109\"\u003e• installing the outdoor unit too low for winter;\u003cbr data-start=\"18162\" data-end=\"18165\"\u003e• neglecting drainage;\u003cbr data-start=\"18188\" data-end=\"18191\"\u003e• buying based only on price without validating actual comfort.\u003c\/p\u003e\n\u003cp data-start=\"18256\" data-end=\"18450\"\u003eAt AirGreen, we prefer to clarify these points before installation. This helps avoid unpleasant surprises and ensures a more durable, cleaner, and more comfortable installation.\u003c\/p\u003e\n\u003ch1 data-start=\"18452\" data-end=\"18518\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18454\" data-end=\"18518\"\u003eWhy choose AirGreen to install the Zephyr ZE-09CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"18520\" data-end=\"18794\"\u003eAirGreen is a company specializing in \u003cstrong data-start=\"18563\" data-end=\"18571\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs wall-mounted, central, and multi-zone heat pump systems in Greater Montreal. We regularly operate in \u003cstrong data-start=\"18726\" data-end=\"18793\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18796\" data-end=\"18846\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"18848\" data-end=\"19365\"\u003e• a clear evaluation before work begins;\u003cbr data-start=\"18892\" data-end=\"18895\"\u003e• sizing adapted to the room;\u003cbr data-start=\"18936\" data-end=\"18939\"\u003e• a thorough electrical inspection;\u003cbr data-start=\"18980\" data-end=\"18983\"\u003e• an installation compliant with technical requirements;\u003cbr data-start=\"19038\" data-end=\"19041\"\u003e• special attention to the aesthetics of the installation path;\u003cbr data-start=\"19099\" data-end=\"19102\"\u003e• good positioning of the indoor unit;\u003cbr data-start=\"19150\" data-end=\"19153\"\u003e• an outdoor location designed for winter;\u003cbr data-start=\"19201\" data-end=\"19204\"\u003e• simple explanations on how to use the device;\u003cbr data-start=\"19261\" data-end=\"19264\"\u003e• a structured after-sales service;\u003cbr data-start=\"19301\" data-end=\"19304\"\u003e• a team familiar with the realities of Quebec buildings.\u003c\/p\u003e\n\u003cp data-start=\"19367\" data-end=\"19668\"\u003eWe know a heat pump is a significant investment, even when it’s a 9,000 BTU model. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how it should be used to deliver its best performance.\u003c\/p\u003e\n\u003ch1 data-start=\"19670\" data-end=\"19747\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19672\" data-end=\"19747\"\u003eAn efficient, compact HVAC solution well suited to targeted needs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"19749\" data-end=\"20220\"\u003eThe \u003cstrong data-start=\"19752\" data-end=\"19800\"\u003eZephyr CB22 R32 ZE-09CB22 Wall Heat Pump\u003c\/strong\u003e is an interesting choice for homeowners looking for a compact, efficient wall heat pump capable of providing good comfort year-round. With its \u003cstrong data-start=\"19968\" data-end=\"19981\"\u003e9,000 BTU\u003c\/strong\u003e, \u003cstrong data-start=\"19987\" data-end=\"20004\"\u003eSEER2 of 22.5\u003c\/strong\u003e, \u003cstrong data-start=\"20010\" data-end=\"20030\"\u003eEnergy Star V6.1\u003c\/strong\u003e, operation on \u003cstrong data-start=\"20054\" data-end=\"20061\"\u003eR32\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"20111\" data-end=\"20123\"\u003e28 dB(A)\u003c\/strong\u003e, and heating capacity down to \u003cstrong data-start=\"20160\" data-end=\"20170\"\u003e-25 °C\u003c\/strong\u003e, it meets the needs of targeted rooms well.\u003c\/p\u003e\n\u003cp data-start=\"20222\" data-end=\"20604\"\u003eHowever, it requires a serious installation. The electrical circuit \u003cstrong data-start=\"20294\" data-end=\"20307\"\u003e208\/230 V\u003c\/strong\u003e, piping \u003cstrong data-start=\"20323\" data-end=\"20339\"\u003e1\/4 - 3\/8 in\u003c\/strong\u003e, clearances, drainage, wall positioning, and outdoor location must be verified before confirming the project. It’s exactly this kind of detail that distinguishes an ordinary installation from a durable, comfortable, and well-thought-out one.\u003c\/p\u003e\n\u003cp data-start=\"20606\" data-end=\"20944\"\u003eTo get a clear quote, compare this model with other Zephyr options, or schedule an installation in \u003cstrong data-start=\"20723\" data-end=\"20786\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact AirGreen now. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925390628,"sku":"ZE-09CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_1ef5ae81-7d25-4988-a139-2de2c08116aa.png?v=1783356992","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-cb22-r32-9000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}