{"product_id":"thermopompe-murale-zephyr-ub32-r454b-9000-btu-montreal-laval-rive-sud","title":"ZEPHYR UB32 R454B Wall Heat Pump | 9000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"118\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"118\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32: an ultra-efficient 9,000 BTU solution for Quebec comfort\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"120\" data-end=\"637\"\u003eThe \u003cstrong data-start=\"123\" data-end=\"173\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32\u003c\/strong\u003e is aimed at owners looking for a compact, high-performance HVAC solution designed for Quebec’s climate realities. With its nominal capacity of \u003cstrong data-start=\"336\" data-end=\"366\"\u003e9,000 BTU in cooling\u003c\/strong\u003e, efficiency reaching \u003cstrong data-start=\"400\" data-end=\"412\"\u003e32 SEER2\u003c\/strong\u003e, heating down to \u003cstrong data-start=\"436\" data-end=\"446\"\u003e-30 °C\u003c\/strong\u003e, and operation with refrigerant \u003cstrong data-start=\"484\" data-end=\"493\"\u003eR454B\u003c\/strong\u003e, this model is particularly suitable for a bedroom, office, condo, small open area, or a room difficult to balance.\u003c\/p\u003e\n\u003cp data-start=\"639\" data-end=\"1094\"\u003eAt AirGreen, we recommend this type of unit when the customer wants an efficient, quiet wall-mounted heat pump well suited to a specific space. The \u003cstrong data-start=\"805\" data-end=\"818\"\u003eZE-09UB32\u003c\/strong\u003e model is not an oversized machine designed for large volumes: it is rather a high-efficiency wall-mounted heat pump capable of providing stable comfort while limiting energy consumption when properly selected, installed, and configured.\u003c\/p\u003e\n\u003cp data-start=\"1096\" data-end=\"1635\"\u003eThe Zephyr UB32 brochure highlights several important features: \u003cstrong data-start=\"1167\" data-end=\"1187\"\u003eup to 32 SEER2\u003c\/strong\u003e, \u003cstrong data-start=\"1189\" data-end=\"1216\"\u003e12 HSPF2 depending on the series\u003c\/strong\u003e, \u003cstrong data-start=\"1218\" data-end=\"1246\"\u003eheating down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1248\" data-end=\"1280\"\u003ecooling down to -15 °C\u003c\/strong\u003e, variable frequency technology, silent mode, night mode, iFeel mode, automatic defrost, automatic cleaning, automatic oscillation, and operation with \u003cstrong data-start=\"1444\" data-end=\"1453\"\u003eR454B\u003c\/strong\u003e. These features make it a modern solution for residential installations in Montreal, Laval, Longueuil, the South Shore, and the North Shore.\u003c\/p\u003e\n\u003ch2 data-start=\"1637\" data-end=\"1703\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1640\" data-end=\"1703\"\u003eKey technical features of the ZE-09UB32 model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1705\" data-end=\"1806\"\u003eFor the model \u003cstrong data-start=\"1720\" data-end=\"1745\"\u003eZephyr UB32 ZE-09UB32\u003c\/strong\u003e, the main brochure data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"1808\" data-end=\"2888\"\u003e• \u003cstrong data-start=\"1810\" data-end=\"1829\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"1829\" data-end=\"1832\"\u003e• \u003cstrong data-start=\"1834\" data-end=\"1850\"\u003eSeries: UB32\u003c\/strong\u003e\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e• \u003cstrong data-start=\"1855\" data-end=\"1884\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"1884\" data-end=\"1887\"\u003e• \u003cstrong data-start=\"1889\" data-end=\"1911\"\u003eModel: ZE-09UB32\u003c\/strong\u003e\u003cbr data-start=\"1911\" data-end=\"1914\"\u003e• \u003cstrong data-start=\"1916\" data-end=\"1969\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"1969\" data-end=\"1972\"\u003e• \u003cstrong data-start=\"1974\" data-end=\"2023\"\u003eHeating capacity at 8.3 °C: 12,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2023\" data-end=\"2026\"\u003e• \u003cstrong data-start=\"2028\" data-end=\"2042\"\u003eSEER2: 32\u003c\/strong\u003e\u003cbr data-start=\"2042\" data-end=\"2045\"\u003e• \u003cstrong data-start=\"2047\" data-end=\"2066\"\u003eHSPF2 IV: 11.8\u003c\/strong\u003e\u003cbr data-start=\"2066\" data-end=\"2069\"\u003e• \u003cstrong data-start=\"2071\" data-end=\"2093\"\u003eEER2: 18.35 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2093\" data-end=\"2096\"\u003e• \u003cstrong data-start=\"2098\" data-end=\"2130\"\u003eHeating COP at 8.3 °C: 4.6\u003c\/strong\u003e\u003cbr data-start=\"2130\" data-end=\"2133\"\u003e• \u003cstrong data-start=\"2135\" data-end=\"2158\"\u003eCOP at -15 °C: 2.25\u003c\/strong\u003e\u003cbr data-start=\"2158\" data-end=\"2161\"\u003e• \u003cstrong data-start=\"2163\" data-end=\"2189\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"2189\" data-end=\"2192\"\u003e• \u003cstrong data-start=\"2194\" data-end=\"2217\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"2217\" data-end=\"2220\"\u003e• \u003cstrong data-start=\"2222\" data-end=\"2258\"\u003eRefrigerant charge: 52.91 oz\u003c\/strong\u003e\u003cbr data-start=\"2258\" data-end=\"2261\"\u003e• \u003cstrong data-start=\"2263\" data-end=\"2294\"\u003eAirflow: 241 to 365 CFM\u003c\/strong\u003e\u003cbr data-start=\"2294\" data-end=\"2297\"\u003e• \u003cstrong data-start=\"2299\" data-end=\"2364\"\u003eIndoor sound pressure: 47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2364\" data-end=\"2367\"\u003e• \u003cstrong data-start=\"2369\" data-end=\"2414\"\u003eOutdoor sound pressure: 54 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2414\" data-end=\"2417\"\u003e• \u003cstrong data-start=\"2419\" data-end=\"2460\"\u003eVoltage: 208 \/ 230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"2460\" data-end=\"2463\"\u003e• \u003cstrong data-start=\"2465\" data-end=\"2479\"\u003eMCA: 14 A\u003c\/strong\u003e\u003cbr data-start=\"2479\" data-end=\"2482\"\u003e• \u003cstrong data-start=\"2484\" data-end=\"2498\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"2498\" data-end=\"2501\"\u003e• \u003cstrong data-start=\"2503\" data-end=\"2567\"\u003eRequired communication wire: 4\/14 copper multistrand 600 V\u003c\/strong\u003e\u003cbr data-start=\"2567\" data-end=\"2570\"\u003e• \u003cstrong data-start=\"2572\" data-end=\"2603\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"2603\" data-end=\"2606\"\u003e• \u003cstrong data-start=\"2608\" data-end=\"2635\"\u003eGas piping: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"2635\" data-end=\"2638\"\u003e• \u003cstrong data-start=\"2640\" data-end=\"2692\"\u003eMinimum-maximum piping length: 10 to 98.4 feet\u003c\/strong\u003e\u003cbr data-start=\"2692\" data-end=\"2695\"\u003e• \u003cstrong data-start=\"2697\" data-end=\"2734\"\u003eMaximum elevation difference: 65 feet\u003c\/strong\u003e\u003cbr data-start=\"2734\" data-end=\"2737\"\u003e• \u003cstrong data-start=\"2739\" data-end=\"2775\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"2775\" data-end=\"2778\"\u003e• \u003cstrong data-start=\"2780\" data-end=\"2823\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"2823\" data-end=\"2826\"\u003e• \u003cstrong data-start=\"2828\" data-end=\"2888\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2890\" data-end=\"3060\"\u003eThe dimensions shown in the brochure are given in \u003cstrong data-start=\"2955\" data-end=\"2968\"\u003eL × H × D\u003c\/strong\u003e format. To facilitate reading during installation, they can be presented in \u003cstrong data-start=\"3045\" data-end=\"3058\"\u003eL × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3062\" data-end=\"3162\"\u003e• \u003cstrong data-start=\"3064\" data-end=\"3110\"\u003eIndoor unit: 42.06 × 9.06 × 12.63 in\u003c\/strong\u003e\u003cbr data-start=\"3110\" data-end=\"3113\"\u003e• \u003cstrong data-start=\"3115\" data-end=\"3162\"\u003eOutdoor unit: 33.88 × 12.19 × 25.50 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3164\" data-end=\"3524\"\u003eThis information is essential before confirming an installation. A 9,000 BTU heat pump may seem simple to install, but it is still necessary to verify \u003cstrong data-start=\"3323\" data-end=\"3353\"\u003ethe available wall space\u003c\/strong\u003e, \u003cstrong data-start=\"3355\" data-end=\"3386\"\u003ethe piping passage\u003c\/strong\u003e, \u003cstrong data-start=\"3388\" data-end=\"3417\"\u003ethe electrical supply\u003c\/strong\u003e, \u003cstrong data-start=\"3419\" data-end=\"3446\"\u003ethe outdoor clearance\u003c\/strong\u003e, \u003cstrong data-start=\"3448\" data-end=\"3463\"\u003ethe drainage\u003c\/strong\u003e, and \u003cstrong data-start=\"3467\" data-end=\"3523\"\u003ecompatibility with the client’s actual expectations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"3526\" data-end=\"3585\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3529\" data-end=\"3585\"\u003eVery high energy efficiency with 32 SEER2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3587\" data-end=\"3857\"\u003eThe most impressive point of the \u003cstrong data-start=\"3625\" data-end=\"3645\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e is its cooling performance. With a \u003cstrong data-start=\"3690\" data-end=\"3705\"\u003eSEER2 of 32\u003c\/strong\u003e, this model positions itself as a very high-performance wall-mounted heat pump for customers who want to reduce their electricity consumption during the summer.\u003c\/p\u003e\n\u003cp data-start=\"3859\" data-end=\"4289\"\u003eThe SEER2 measures seasonal cooling efficiency. The higher the value, the more effectively the device can produce cooling over an entire season. In the context of Greater Montreal, where heat waves can become intense, a high-efficiency machine can make a real difference, especially when used daily in a bedroom, office, or living area.\u003c\/p\u003e\n\u003cp data-start=\"4291\" data-end=\"4614\"\u003eAnother advantage is the \u003cstrong data-start=\"4315\" data-end=\"4338\"\u003eEER2 of 18.35 BTU\/W\u003c\/strong\u003e, which indicates very good cooling efficiency under specific conditions. For a customer, this means the machine is not only efficient on paper: it is designed to maintain a good level of comfort with controlled electricity consumption.\u003c\/p\u003e\n\u003cp data-start=\"4616\" data-end=\"4925\"\u003eAt AirGreen, we always explain that energy efficiency also depends on installation. A very efficient heat pump can lose some of its advantage if it is poorly positioned, if the piping is poorly adapted, if the drain is misconfigured, or if the outdoor unit lacks clearance.\u003c\/p\u003e\n\u003ch2 data-start=\"4927\" data-end=\"4992\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4930\" data-end=\"4992\"\u003eHeating down to -30 °C: a real advantage for Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4994\" data-end=\"5343\"\u003eThe Zephyr brochure presents the UB32 series as a heat pump capable of providing heating down to \u003cstrong data-start=\"5098\" data-end=\"5108\"\u003e-30 °C\u003c\/strong\u003e. This is an important feature for Quebec homeowners who want to use their heat pump not only as an air conditioner but also as a primary or supplementary heating source for much of the winter.\u003c\/p\u003e\n\u003cp data-start=\"5345\" data-end=\"5445\"\u003eFor the model \u003cstrong data-start=\"5360\" data-end=\"5373\"\u003eZE-09UB32\u003c\/strong\u003e, the indicated heating performance is particularly useful:\u003c\/p\u003e\n\u003cp data-start=\"5447\" data-end=\"5594\"\u003e• \u003cstrong data-start=\"5449\" data-end=\"5474\"\u003e12,200 BTU\/h at 8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5474\" data-end=\"5477\"\u003e• \u003cstrong data-start=\"5479\" data-end=\"5505\"\u003e13,000 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5505\" data-end=\"5508\"\u003e• \u003cstrong data-start=\"5510\" data-end=\"5535\"\u003e12,200 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"5535\" data-end=\"5538\"\u003e• \u003cstrong data-start=\"5540\" data-end=\"5565\"\u003e11,300 BTU\/h at -20 °C\u003c\/strong\u003e\u003cbr data-start=\"5565\" data-end=\"5568\"\u003e• \u003cstrong data-start=\"5570\" data-end=\"5594\"\u003e9,000 BTU\/h at -25 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5596\" data-end=\"5954\"\u003eThese figures show that the machine retains a significant capacity at low temperatures. However, it is important to understand what this means. \u003cstrong data-start=\"5746\" data-end=\"5879\"\u003eA heat pump that operates down to -30 °C does not always produce the same power at -30 °C as it does at a milder temperature.\u003c\/strong\u003e Capacity generally decreases as the outside temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"5956\" data-end=\"6374\"\u003eIn a well-insulated house, a model like the \u003cstrong data-start=\"6004\" data-end=\"6017\"\u003eZE-09UB32\u003c\/strong\u003e can be very effective for heating a specific room or area. In an older, poorly insulated, or very windy house, supplementary heating may still be necessary during extreme cold periods. Our role is to assess the building, area, insulation, windows, and actual use of the room before recommending this model.\u003c\/p\u003e\n\u003ch2 data-start=\"6376\" data-end=\"6451\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6379\" data-end=\"6451\"\u003eR454B: a modern refrigerant for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6453\" data-end=\"6837\"\u003eThe \u003cstrong data-start=\"6456\" data-end=\"6481\"\u003eZephyr UB32 ZE-09UB32\u003c\/strong\u003e uses the refrigerant \u003cstrong data-start=\"6505\" data-end=\"6514\"\u003eR454B\u003c\/strong\u003e. This gas is part of the new refrigerants used in recent generations of HVAC equipment. For the customer, the refrigerant name may seem technical, but it is important because it influences the design of the unit, installation practices, and the evolution of available equipment on the market.\u003c\/p\u003e\n\u003cp data-start=\"6839\" data-end=\"7172\"\u003eWith a charge of \u003cstrong data-start=\"6858\" data-end=\"6870\"\u003e52.91 oz\u003c\/strong\u003e, this heat pump must be installed according to the manufacturer's guidelines. Steps such as leak testing, vacuuming, checking connections, respecting pipe length, and commissioning are essential. \u003cstrong data-start=\"7110\" data-end=\"7172\"\u003eA modern heat pump requires a rigorous installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7174\" data-end=\"7511\"\u003eAt AirGreen, we pay special attention to installations using new refrigerants. The quality of flare connections, line cleanliness, electrical compliance, and final inspection are not minor details: they are essential conditions to preserve the performance and durability of the unit.\u003c\/p\u003e\n\u003ch2 data-start=\"7513\" data-end=\"7596\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7516\" data-end=\"7596\"\u003eIndoor comfort: 4D mode, automatic oscillation, and Inverter technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7598\" data-end=\"7876\"\u003eThe brochure highlights the \u003cstrong data-start=\"7626\" data-end=\"7637\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"7643\" data-end=\"7670\"\u003eautomatic oscillation\u003c\/strong\u003e, two important features to improve air distribution in the room. The goal is simple: to avoid cold or hot spots and help the heat pump maintain a more even temperature.\u003c\/p\u003e\n\u003cp data-start=\"7878\" data-end=\"8296\"\u003eIn a bedroom, for example, a poor air jet can quickly become uncomfortable if the unit blows directly toward the bed. In an office, poorly directed airflow can be disturbing for several hours. In a living room, poor distribution can leave part of the room too hot or too cold. The \u003cstrong data-start=\"8199\" data-end=\"8210\"\u003e4D mode\u003c\/strong\u003e helps better direct the air, but the location of the indoor unit remains essential.\u003c\/p\u003e\n\u003cp data-start=\"8298\" data-end=\"8643\"\u003eVariable frequency technology, often called \u003cstrong data-start=\"8351\" data-end=\"8363\"\u003eInverter\u003c\/strong\u003e, allows the device to adjust its power in real time. Instead of simply turning on and off, the heat pump modulates its effort according to needs. This reduces temperature fluctuations, improves comfort, and limits energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"8645\" data-end=\"8812\"\u003eThis is very important: \u003cstrong data-start=\"8677\" data-end=\"8812\"\u003eperformance comes not only from BTU power but from the machine’s ability to maintain a stable temperature.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"8814\" data-end=\"8871\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8817\" data-end=\"8871\"\u003eConvenient features for everyday use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8873\" data-end=\"8972\"\u003eThe Zephyr UB32 series includes several features designed to make daily use easier:\u003c\/p\u003e\n\u003cp data-start=\"8974\" data-end=\"9571\"\u003e• \u003cstrong data-start=\"8976\" data-end=\"8989\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"8989\" data-end=\"8992\"\u003e• \u003cstrong data-start=\"8994\" data-end=\"9010\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"9010\" data-end=\"9013\"\u003e• \u003cstrong data-start=\"9015\" data-end=\"9029\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"9029\" data-end=\"9032\"\u003e• \u003cstrong data-start=\"9034\" data-end=\"9054\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"9054\" data-end=\"9057\"\u003e• \u003cstrong data-start=\"9059\" data-end=\"9077\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"9077\" data-end=\"9080\"\u003e• \u003cstrong data-start=\"9082\" data-end=\"9100\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"9100\" data-end=\"9103\"\u003e• \u003cstrong data-start=\"9105\" data-end=\"9134\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"9134\" data-end=\"9137\"\u003e• \u003cstrong data-start=\"9139\" data-end=\"9158\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"9158\" data-end=\"9161\"\u003e• \u003cstrong data-start=\"9163\" data-end=\"9203\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"9203\" data-end=\"9206\"\u003e• \u003cstrong data-start=\"9208\" data-end=\"9244\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"9244\" data-end=\"9247\"\u003e• \u003cstrong data-start=\"9249\" data-end=\"9274\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"9274\" data-end=\"9277\"\u003e• \u003cstrong data-start=\"9279\" data-end=\"9304\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"9304\" data-end=\"9307\"\u003e• \u003cstrong data-start=\"9309\" data-end=\"9347\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"9347\" data-end=\"9350\"\u003e• \u003cstrong data-start=\"9352\" data-end=\"9374\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"9374\" data-end=\"9377\"\u003e• \u003cstrong data-start=\"9379\" data-end=\"9407\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"9407\" data-end=\"9410\"\u003e• \u003cstrong data-start=\"9412\" data-end=\"9441\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"9441\" data-end=\"9444\"\u003e• \u003cstrong data-start=\"9446\" data-end=\"9488\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"9488\" data-end=\"9491\"\u003e• \u003cstrong data-start=\"9493\" data-end=\"9521\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"9521\" data-end=\"9524\"\u003e• \u003cstrong data-start=\"9526\" data-end=\"9571\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9573\" data-end=\"9977\"\u003eThese features do not replace good installation but clearly improve the user experience. The \u003cstrong data-start=\"9691\" data-end=\"9707\"\u003esilent mode\u003c\/strong\u003e can be useful in a bedroom. The \u003cstrong data-start=\"9745\" data-end=\"9758\"\u003enight mode\u003c\/strong\u003e helps maintain discreet comfort during sleep. The \u003cstrong data-start=\"9823\" data-end=\"9837\"\u003eiFeel mode\u003c\/strong\u003e adjusts comfort based on the temperature sensed around the remote control, which can be very practical in certain rooms.\u003c\/p\u003e\n\u003cp data-start=\"9979\" data-end=\"10388\"\u003eThe \u003cstrong data-start=\"9982\" data-end=\"10007\"\u003eautomatic defrost\u003c\/strong\u003e, \u003cstrong data-start=\"10012\" data-end=\"10040\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"10047\" data-end=\"10078\"\u003eheated outdoor chassis\u003c\/strong\u003e are especially relevant for Quebec’s climate. In winter, the outdoor unit is exposed to frost, snow, and moisture. These features help the device better handle harsh conditions, provided the outdoor unit is installed with proper clearances and on a suitable base.\u003c\/p\u003e\n\u003ch2 data-start=\"10390\" data-end=\"10444\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10393\" data-end=\"10444\"\u003eA 9,000 BTU heat pump: for which spaces?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10446\" data-end=\"10572\"\u003eA 9,000 BTU wall-mounted heat pump generally suits more targeted spaces. It can be a good solution for:\u003c\/p\u003e\n\u003cp data-start=\"10574\" data-end=\"10847\"\u003e• a master bedroom;\u003cbr data-start=\"10599\" data-end=\"10602\"\u003e• a home office;\u003cbr data-start=\"10625\" data-end=\"10628\"\u003e• a small open area;\u003cbr data-start=\"10654\" data-end=\"10657\"\u003e• a well-insulated condo;\u003cbr data-start=\"10679\" data-end=\"10682\"\u003e• a room above a garage;\u003cbr data-start=\"10716\" data-end=\"10719\"\u003e• a home extension;\u003cbr data-start=\"10745\" data-end=\"10748\"\u003e• a partially open basement;\u003cbr data-start=\"10783\" data-end=\"10786\"\u003e• a space that remains too hot in summer or too cold in winter.\u003c\/p\u003e\n\u003cp data-start=\"10849\" data-end=\"11172\"\u003eHowever, choosing a 9,000 BTU unit should never be based solely on the area. You must also consider \u003cstrong data-start=\"10970\" data-end=\"10985\"\u003einsulation\u003c\/strong\u003e, \u003cstrong data-start=\"10987\" data-end=\"11017\"\u003ewindow orientation\u003c\/strong\u003e, \u003cstrong data-start=\"11019\" data-end=\"11044\"\u003eceiling height\u003c\/strong\u003e, \u003cstrong data-start=\"11046\" data-end=\"11072\"\u003esun exposure\u003c\/strong\u003e, \u003cstrong data-start=\"11074\" data-end=\"11098\"\u003eair circulation\u003c\/strong\u003e, \u003cstrong data-start=\"11100\" data-end=\"11123\"\u003eroom usage\u003c\/strong\u003e, and \u003cstrong data-start=\"11127\" data-end=\"11171\"\u003edesired heating level in winter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11174\" data-end=\"11590\"\u003eIn a recent condo in Montreal, a 9,000 BTU unit can be sufficient for a well-designed living area. In a house in Laval, it can be ideal for a bedroom or an office. On the South Shore, it can suit a room heavily exposed to the sun if properly sized. On the North Shore, it can be useful to supplement heating in an area farther from the main system.\u003c\/p\u003e\n\u003cp data-start=\"11592\" data-end=\"11914\"\u003e\u003cstrong data-start=\"11592\" data-end=\"11662\"\u003eAn overly powerful device can reduce comfort in air conditioning\u003c\/strong\u003e because it reaches the temperature too quickly without properly dehumidifying. Conversely, an undersized device will run constantly and struggle during extreme days. That’s why evaluation before installation is essential.\u003c\/p\u003e\n\u003ch2 data-start=\"11916\" data-end=\"11980\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11919\" data-end=\"11980\"\u003eElectrical installation: 208\/230 V, MCA 14 A, and MOP 20 A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11982\" data-end=\"12204\"\u003eThe \u003cstrong data-start=\"11992\" data-end=\"12005\"\u003eZE-09UB32\u003c\/strong\u003e model operates at \u003cstrong data-start=\"12020\" data-end=\"12049\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e. The technical sheet indicates a \u003cstrong data-start=\"12081\" data-end=\"12096\"\u003eMCA of 14 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12103\" data-end=\"12118\"\u003eMOP of 20 A\u003c\/strong\u003e. This data allows validating the required electrical circuit before installation.\u003c\/p\u003e\n\u003cp data-start=\"12206\" data-end=\"12687\"\u003eEven though this model is 9,000 BTU, the importance of electrical verification should not be underestimated. In some older homes in Montreal or Longueuil, the panel may already be fully loaded. In some condos, electrical constraints can also be stricter. Before confirming a project, we always check the available capacity, required breaker, wire gauge, and possible route between the electrical panel and the outdoor unit.\u003c\/p\u003e\n\u003cp data-start=\"12689\" data-end=\"12855\"\u003eThe required communication wire is a \u003cstrong data-start=\"12726\" data-end=\"12761\"\u003e4\/14 copper multi-strand 600 V\u003c\/strong\u003e. This information is important to ensure compliance with the manufacturer's requirements.\u003c\/p\u003e\n\u003ch2 data-start=\"12857\" data-end=\"12922\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12860\" data-end=\"12922\"\u003e1\/4 - 1\/2 inch piping and maximum length of 98.4 feet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12924\" data-end=\"13194\"\u003eThe \u003cstrong data-start=\"12927\" data-end=\"12947\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e uses refrigeration piping of \u003cstrong data-start=\"12987\" data-end=\"13013\"\u003e1\/4 inch for the liquid\u003c\/strong\u003e and \u003cstrong data-start=\"13017\" data-end=\"13039\"\u003e1\/2 inch for the gas\u003c\/strong\u003e. The indicated piping length is \u003cstrong data-start=\"13083\" data-end=\"13102\"\u003e10 to 98.4 feet\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong data-start=\"13139\" data-end=\"13151\"\u003e65 feet\u003c\/strong\u003e and a precharge designed for \u003cstrong data-start=\"13181\" data-end=\"13193\"\u003e25 feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"13196\" data-end=\"13497\"\u003eThis data directly influences the installation planning. For replacing an old system, you should never assume the existing lines are compatible. The diameter, condition of the lines, old refrigerant, accessibility, and cleanliness of the path must be checked.\u003c\/p\u003e\n\u003cp data-start=\"13499\" data-end=\"13733\"\u003eAt AirGreen, we prefer to replace the lines when necessary rather than forcing an installation on questionable piping. This can prevent performance, noise, leakage, or warranty issues later on.\u003c\/p\u003e\n\u003ch2 data-start=\"13735\" data-end=\"13801\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13738\" data-end=\"13801\"\u003eNoise level: a discreet device for living spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13803\" data-end=\"14024\"\u003eThe datasheet indicates an indoor sound pressure level of \u003cstrong data-start=\"13858\" data-end=\"13890\"\u003e47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e depending on fan speed, including silent mode. For a bedroom or office, this noise level is a significant advantage.\u003c\/p\u003e\n\u003cp data-start=\"14026\" data-end=\"14329\"\u003eThe unit is rated at \u003cstrong data-start=\"14060\" data-end=\"14072\"\u003e54 dB(A)\u003c\/strong\u003e. This level remains reasonable, but the outdoor location must be chosen carefully. In dense areas of Montreal, Laval, or Longueuil, consider neighbors, windows, balconies, fences, and noise reflection between walls.  \u003c\/p\u003e\n\u003cp data-start=\"14331\" data-end=\"14578\"\u003eA poorly placed outdoor unit may seem louder than it actually is. Professional installation must consider performance, maintenance access, drainage, snow, ice, and acoustic comfort.  \u003c\/p\u003e\n\u003ch2 data-start=\"14580\" data-end=\"14643\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14583\" data-end=\"14643\"\u003eHVAC maintenance: keep performance year after year  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14645\" data-end=\"14806\"\u003eA high-performance wall-mounted heat pump like the \u003cstrong data-start=\"14689\" data-end=\"14702\"\u003eZE-09UB32\u003c\/strong\u003e must be well maintained. Automatic cleaning helps but does not replace regular maintenance.  \u003c\/p\u003e\n\u003cp data-start=\"14808\" data-end=\"14837\"\u003eWe especially recommend:  \u003c\/p\u003e\n\u003cp data-start=\"14839\" data-end=\"15185\"\u003e• clean filters regularly;  \u003cbr data-start=\"14876\" data-end=\"14879\"\u003e• check the condition of the indoor unit;  \u003cbr data-start=\"14919\" data-end=\"14922\"\u003e• monitor the condensation drain;  \u003cbr data-start=\"14960\" data-end=\"14963\"\u003e• keep the outdoor unit clear;  \u003cbr data-start=\"14999\" data-end=\"15002\"\u003e• remove leaves, snow, ice, and debris;  \u003cbr data-start=\"15059\" data-end=\"15062\"\u003e• have the unit inspected if unusual noise occurs;  \u003cbr data-start=\"15118\" data-end=\"15121\"\u003e• request professional cleaning if performance decreases.  \u003c\/p\u003e\n\u003cp data-start=\"15187\" data-end=\"15335\"\u003eProper maintenance helps preserve \u003cstrong data-start=\"15224\" data-end=\"15252\"\u003eenergy efficiency\u003c\/strong\u003e, \u003cstrong data-start=\"15254\" data-end=\"15274\"\u003enoise level\u003c\/strong\u003e, \u003cstrong data-start=\"15276\" data-end=\"15299\"\u003eair quality\u003c\/strong\u003e, and \u003cstrong data-start=\"15303\" data-end=\"15320\"\u003edurability\u003c\/strong\u003e of the device.  \u003c\/p\u003e\n\u003ch2 data-start=\"15337\" data-end=\"15396\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15340\" data-end=\"15396\"\u003eMistakes to avoid before buying the Zephyr ZE-09UB32  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15398\" data-end=\"15534\"\u003eThe most common mistakes don’t always come from the brand choice. They often come from poor project analysis.  \u003c\/p\u003e\n\u003cp data-start=\"15536\" data-end=\"15564\"\u003eHere are the mistakes to avoid:  \u003c\/p\u003e\n\u003cp data-start=\"15566\" data-end=\"16037\"\u003e• choosing a 9,000 BTU unit solely based on area;  \u003cbr data-start=\"15621\" data-end=\"15624\"\u003e• ignoring sun exposure;  \u003cbr data-start=\"15657\" data-end=\"15660\"\u003e• neglecting insulation;  \u003cbr data-start=\"15683\" data-end=\"15686\"\u003e• placing the indoor unit in the wrong location;  \u003cbr data-start=\"15733\" data-end=\"15736\"\u003e• blowing air directly onto the bed, sofa, or desk;  \u003cbr data-start=\"15792\" data-end=\"15795\"\u003e• assuming old lines are compatible;  \u003cbr data-start=\"15848\" data-end=\"15851\"\u003e• forgetting electrical checks;  \u003cbr data-start=\"15888\" data-end=\"15891\"\u003e• installing the outdoor unit too low for winter;  \u003cbr data-start=\"15944\" data-end=\"15947\"\u003e• neglecting drainage;  \u003cbr data-start=\"15970\" data-end=\"15973\"\u003e• buying based only on SEER2 without validating actual comfort.  \u003c\/p\u003e\n\u003cp data-start=\"16039\" data-end=\"16197\"\u003eAt AirGreen, our approach is to clarify these points before installation. This helps avoid unpleasant surprises and ensures a lasting result.  \u003c\/p\u003e\n\u003ch2 data-start=\"16199\" data-end=\"16271\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16202\" data-end=\"16271\"\u003eWhy choose AirGreen to install the Zephyr UB32 ZE-09UB32  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16273\" data-end=\"16548\"\u003eAirGreen installs, maintains, and replaces HVAC systems in Greater Montreal, including \u003cstrong data-start=\"16366\" data-end=\"16425\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our team understands the constraints of condos, plexes, single-family homes, light commercial buildings, and older buildings.\u003c\/p\u003e\n\u003cp data-start=\"16550\" data-end=\"16600\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"16602\" data-end=\"17033\"\u003e• a clear evaluation before work begins;\u003cbr data-start=\"16646\" data-end=\"16649\"\u003e• sizing adapted to the room;\u003cbr data-start=\"16690\" data-end=\"16693\"\u003e• thorough electrical verification;\u003cbr data-start=\"16734\" data-end=\"16737\"\u003e• a clean and compliant installation;\u003cbr data-start=\"16777\" data-end=\"16780\"\u003e• special attention to drainage;\u003cbr data-start=\"16823\" data-end=\"16826\"\u003e• good positioning of the indoor unit;\u003cbr data-start=\"16874\" data-end=\"16877\"\u003e• an outdoor location designed for winter;\u003cbr data-start=\"16925\" data-end=\"16928\"\u003e• structured after-sales service;\u003cbr data-start=\"16965\" data-end=\"16968\"\u003e• an honest explanation of warranties and available options.\u003c\/p\u003e\n\u003cp data-start=\"17035\" data-end=\"17276\"\u003eA heat pump like the \u003cstrong data-start=\"17060\" data-end=\"17080\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e can deliver excellent performance, but only if installed properly. The right model, in the right place, with the right piping and configuration, makes all the difference.\u003c\/p\u003e\n\u003ch2 data-start=\"17278\" data-end=\"17358\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17281\" data-end=\"17358\"\u003eA compact, efficient wall-mounted heat pump suited for Quebec winters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17360\" data-end=\"17881\"\u003eThe \u003cstrong data-start=\"17363\" data-end=\"17413\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32\u003c\/strong\u003e is a very interesting solution for customers who want a compact, efficient, quiet machine capable of heating down to \u003cstrong data-start=\"17569\" data-end=\"17579\"\u003e-30 °C\u003c\/strong\u003e. With its \u003cstrong data-start=\"17590\" data-end=\"17605\"\u003eSEER2 of 32\u003c\/strong\u003e, \u003cstrong data-start=\"17611\" data-end=\"17628\"\u003eHSPF2 of 11.8\u003c\/strong\u003e, refrigerant \u003cstrong data-start=\"17646\" data-end=\"17655\"\u003eR454B\u003c\/strong\u003e, airflow of \u003cstrong data-start=\"17676\" data-end=\"17693\"\u003e241 to 365 CFM\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"17743\" data-end=\"17755\"\u003e29 dB(A)\u003c\/strong\u003e, and a basic warranty of \u003cstrong data-start=\"17782\" data-end=\"17799\"\u003e10 years parts\u003c\/strong\u003e, this model offers an excellent balance of performance, comfort, and efficiency.\u003c\/p\u003e\n\u003cp data-start=\"17883\" data-end=\"18150\"\u003eFor a bedroom, office, condo, or specific area of the house, the \u003cstrong data-start=\"17958\" data-end=\"17971\"\u003eZE-09UB32\u003c\/strong\u003e can be a very relevant choice. However, sizing, location, electricity, piping, and clearances must be verified before confirming the installation.\u003c\/p\u003e\n\u003cp data-start=\"18152\" data-end=\"18477\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps, or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926373668,"sku":"ZE-09UB32I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRUB32R454BGRANDMONTREAL.png?v=1783357043","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-zephyr-ub32-r454b-9000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}