{"product_id":"ventilo-convecteur-extra-plat-de-thermopompe-elios-24-000-btu","title":"ELIOS Extra-Slim (Pancake) Heat Pump Fan Coil Unit | 24,000 BTU","description":"\u003ch2 data-start=\"94\" data-end=\"183\"\u003e An ultra-slim HVAC solution designed for the most demanding projects in Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"185\" data-end=\"691\"\u003e At \u003cstrong data-start=\"190\" data-end=\"242\"\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e , we work daily on projects where available space, architectural constraints, and performance requirements leave no room for error. The \u003cstrong data-start=\"428\" data-end=\"488\"\u003eELIOS 24,000 BTU ultra-slim (pancake) fan coil unit\u003c\/strong\u003e falls precisely into this category of HVAC solutions designed to meet the realities encountered in \u003cstrong data-start=\"611\" data-end=\"623\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"625\" data-end=\"634\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"636\" data-end=\"649\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"658\" data-end=\"671\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"678\" data-end=\"690\"\u003eSouth Shores\u003c\/strong\u003e .\u003c\/p\u003e\n\n \u003cp data-start=\"693\" data-end=\"1037\"\u003eThis type of unit is not suitable for all projects. It is aimed at owners, property managers and professionals who are looking for discreet integration, reliable thermal performance in cold climates and greater installation flexibility than traditional wall systems or complete ductwork systems.\u003c\/p\u003e\n\n\u003chr data-start=\"1039\" data-end=\"1042\"\u003e\n\n\u003ch2 data-start=\"1044\" data-end=\"1117\"\u003e The \"Pancake\" concept: a clever response to space limitations\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1119\" data-end=\"1179\"\u003e An ultra-slim profile that opens up new possibilities\u003c\/h3\u003e\n\n\u003cp data-start=\"1180\" data-end=\"1396\"\u003e With a height of less than 11 inches, the \u003cstrong data-start=\"1240\" data-end=\"1256\"\u003eGPHLA24R4AS1\u003c\/strong\u003e indoor unit allows for installation configurations often impossible with conventional fan coil units. In practice, this means: \u003c\/p\u003e\n\n\u003cul data-start=\"1397\" data-end=\"1704\"\u003e\n\n\u003cli data-start=\"1397\" data-end=\"1463\"\u003e\n\n\u003cp data-start=\"1399\" data-end=\"1463\"\u003e Direct integration into \u003cstrong data-start=\"1432\" data-end=\"1462\"\u003enarrow suspended ceilings\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1464\" data-end=\"1567\"\u003e\n\n\u003cp data-start=\"1466\" data-end=\"1567\"\u003e An installation above corridors, kitchens or bathrooms without lowering the ceilings,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1568\" data-end=\"1704\"\u003e\n\n \u003cp data-start=\"1570\" data-end=\"1704\"\u003eAn ideal fit for \u003cstrong data-start=\"1596\" data-end=\"1615\"\u003emodern condos\u003c\/strong\u003e , \u003cstrong data-start=\"1621\" data-end=\"1637\"\u003erenovated plexes\u003c\/strong\u003e and \u003cstrong data-start=\"1645\" data-end=\"1670\"\u003ecommercial buildings\u003c\/strong\u003e where mechanical space is limited.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1706\" data-end=\"1901\"\u003e We have notably used this format in buildings in downtown \u003cstrong data-start=\"1777\" data-end=\"1789\"\u003eMontreal\u003c\/strong\u003e , where preserving clear heights was a non-negotiable requirement imposed by the existing architecture.\u003c\/p\u003e\n\n\u003ch3 data-start=\"1903\" data-end=\"1965\"\u003e A solution designed for both aesthetics and functionality\u003c\/h3\u003e\n\n \u003cp data-start=\"1966\" data-end=\"2311\"\u003eUnlike some compact systems that compromise airflow, the ELIOS Pancake maintains an effective balance between \u003cstrong data-start=\"2104\" data-end=\"2127\"\u003ea small footprint\u003c\/strong\u003e and \u003cstrong data-start=\"2131\" data-end=\"2157\"\u003econtrolled distribution\u003c\/strong\u003e . The grilles can be strategically positioned, reducing cold or overheated areas and improving overall occupant comfort.\u003c\/p\u003e\n\n\u003chr data-start=\"2313\" data-end=\"2316\"\u003e\n\n\u003ch2 data-start=\"2318\" data-end=\"2370\"\u003e Controlled air distribution and indoor comfort\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2372\" data-end=\"2416\"\u003e Airflow adapted to complex spaces\u003c\/h3\u003e\n\n\u003cp data-start=\"2417\" data-end=\"2620\"\u003e With an airflow of up to \u003cstrong data-start=\"2449\" data-end=\"2460\"\u003e824 CFM\u003c\/strong\u003e , the system provides sufficient air circulation to serve multiple zones from a single unit. This capacity is particularly useful in: \u003c\/p\u003e\n\n\u003cul data-start=\"2621\" data-end=\"2774\"\u003e\n\n\u003cli data-start=\"2621\" data-end=\"2655\"\u003e\n\n\u003cp data-start=\"2623\" data-end=\"2655\"\u003e Open-plan apartments, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2656\" data-end=\"2685\"\u003e\n\n\u003cp data-start=\"2658\" data-end=\"2685\"\u003e Professional offices, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2686\" data-end=\"2774\"\u003e\n\n\u003cp data-start=\"2688\" data-end=\"2774\"\u003e Light commercial premises requiring a stable temperature across the entire surface.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"2776\" data-end=\"2941\"\u003eThe available static pressure facilitates the use of short, well-sized conduits, which reduces losses and improves the overall efficiency of the system.\u003c\/p\u003e\n\n\u003ch3 data-start=\"2943\" data-end=\"2989\"\u003e Reduced humidity and summer comfort\u003c\/h3\u003e\n\n\u003cp data-start=\"2990\" data-end=\"3175\"\u003e The \u003cstrong data-start=\"3005\" data-end=\"3051\"\u003edehumidification capacity of 4.04 pints per hour\u003c\/strong\u003e plays a key role during the humid summers typical of \u003cstrong data-start=\"3105\" data-end=\"3117\"\u003eMontreal\u003c\/strong\u003e and the \u003cstrong data-start=\"3127\" data-end=\"3139\"\u003eSouth Shore\u003c\/strong\u003e . In practice, this translates to: \u003c\/p\u003e\n\n\u003cul data-start=\"3176\" data-end=\"3326\"\u003e\n\n\u003cli data-start=\"3176\" data-end=\"3217\"\u003e\n\n\u003cp data-start=\"3178\" data-end=\"3217\"\u003e A faster feeling of freshness \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3218\" data-end=\"3247\"\u003e\n\n\u003cp data-start=\"3220\" data-end=\"3247\"\u003e Healthier indoor air, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3248\" data-end=\"3326\"\u003e\n\n\u003cp data-start=\"3250\" data-end=\"3326\"\u003e A reduction in condensation problems in poorly ventilated dwellings. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"3328\" data-end=\"3331\"\u003e\n\n\u003ch2 data-start=\"3333\" data-end=\"3390\"\u003e Heating performance designed for Quebec winters\u003c\/h2\u003e\n\n\u003ch3 data-start=\"3392\" data-end=\"3432\"\u003e Stable operation down to -25°C\u003c\/h3\u003e\n\n \u003cp data-start=\"3433\" data-end=\"3658\"\u003eThe \u003cstrong data-start=\"3452\" data-end=\"3468\"\u003eESHEA24R2AN1\u003c\/strong\u003e outdoor unit is designed to maintain reliable performance in harsh winter conditions. Measured performance demonstrates a genuine heating capacity even when temperatures drop: \u003c\/p\u003e\n\n\u003cul data-start=\"3659\" data-end=\"3738\"\u003e\n\n\u003cli data-start=\"3659\" data-end=\"3684\"\u003e\n\n\u003cp data-start=\"3661\" data-end=\"3684\"\u003e \u003cstrong data-start=\"3661\" data-end=\"3683\"\u003e19,800 BTU at -8°C\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3685\" data-end=\"3711\"\u003e\n\n\u003cp data-start=\"3687\" data-end=\"3711\"\u003e \u003cstrong data-start=\"3687\" data-end=\"3710\"\u003e19,000 BTU at -15°C\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3712\" data-end=\"3738\"\u003e\n\n\u003cp data-start=\"3714\" data-end=\"3738\"\u003e \u003cstrong data-start=\"3714\" data-end=\"3737\"\u003e15,000 BTU at -25°C\u003c\/strong\u003e .\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3740\" data-end=\"3924\"\u003e In our projects carried out on the \u003cstrong data-start=\"3773\" data-end=\"3786\"\u003eNorth Shore\u003c\/strong\u003e , this stability has made it possible to limit the use of supplementary electricity, while maintaining constant comfort in the living spaces.\u003c\/p\u003e\n\n\u003ch3 data-start=\"3926\" data-end=\"3974\"\u003e Consistent and predictable energy performance\u003c\/h3\u003e\n\n\u003cp data-start=\"3975\" data-end=\"4047\"\u003e The seasonal efficiency values ​​indicate a balanced system: \u003c\/p\u003e\n\n\u003cul data-start=\"4048\" data-end=\"4212\"\u003e\n\n\u003cli data-start=\"4048\" data-end=\"4087\"\u003e\n\n\u003cp data-start=\"4050\" data-end=\"4087\"\u003e \u003cstrong data-start=\"4050\" data-end=\"4064\"\u003eSEER2: 16\u003c\/strong\u003e for air conditioning,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4088\" data-end=\"4123\"\u003e\n\n \u003cp data-start=\"4090\" data-end=\"4123\"\u003e\u003cstrong data-start=\"4090\" data-end=\"4109\"\u003eHSPF2 up to 9\u003c\/strong\u003e in heating mode, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4124\" data-end=\"4167\"\u003e\n\n\u003cp data-start=\"4126\" data-end=\"4167\"\u003e \u003cstrong data-start=\"4126\" data-end=\"4139\"\u003eEER2: 10\u003c\/strong\u003e in instantaneous performance, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4168\" data-end=\"4212\"\u003e\n\n\u003cp data-start=\"4170\" data-end=\"4212\"\u003e \u003cstrong data-start=\"4170\" data-end=\"4211\"\u003eStable COP even in cold conditions\u003c\/strong\u003e .\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4214\" data-end=\"4408\"\u003e For our customers, this translates into controlled electricity consumption and better predictability of operating costs, a point often underestimated when choosing an HVAC system.\u003c\/p\u003e\n\n\u003chr data-start=\"4410\" data-end=\"4413\"\u003e\n\n\u003ch2 data-start=\"4415\" data-end=\"4468\"\u003e R-454B refrigerant: a future-proof choice\u003c\/h2\u003e\n\n\u003cp data-start=\"4470\" data-end=\"4604\"\u003e \u003cstrong data-start=\"4473\" data-end=\"4483\"\u003eR-454B\u003c\/strong\u003e represents a significant improvement over older refrigerants. Its use in the ELIOS Pancake allows for: \u003c\/p\u003e\n\n\u003cul data-start=\"4605\" data-end=\"4796\"\u003e\n\n\u003cli data-start=\"4605\" data-end=\"4649\"\u003e\n\n\u003cp data-start=\"4607\" data-end=\"4649\"\u003e A reduction in environmental impact, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4650\" data-end=\"4704\"\u003e\n\n\u003cp data-start=\"4652\" data-end=\"4704\"\u003e Compliance with current and future standards \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4705\" data-end=\"4796\"\u003e\n\n\u003cp data-start=\"4707\" data-end=\"4796\"\u003e Greater peace of mind for owners and managers in the long term.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"4798\" data-end=\"4997\"\u003eIn several commercial projects in \u003cstrong data-start=\"4835\" data-end=\"4844\"\u003eLaval\u003c\/strong\u003e and \u003cstrong data-start=\"4848\" data-end=\"4861\"\u003eLongueuil\u003c\/strong\u003e , this factor weighed heavily in the final decision, particularly for buildings subject to internal environmental policies.\u003c\/p\u003e\n\n\u003chr data-start=\"4999\" data-end=\"5002\"\u003e\n\n\u003ch2 data-start=\"5004\" data-end=\"5073\"\u003e Noise levels suitable for residential and professional environments\u003c\/h2\u003e\n\n\u003cp data-start=\"5075\" data-end=\"5229\"\u003e The internal noise level, between \u003cstrong data-start=\"5117\" data-end=\"5139\"\u003e51.5 and 56.5 dB(A)\u003c\/strong\u003e depending on the operating mode, allows installation in sensitive areas such as: \u003c\/p\u003e\n\n\u003cul data-start=\"5230\" data-end=\"5329\"\u003e\n\n\u003cli data-start=\"5230\" data-end=\"5255\"\u003e\n\n\u003cp data-start=\"5232\" data-end=\"5255\"\u003e The bedrooms, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5256\" data-end=\"5281\"\u003e\n\n\u003cp data-start=\"5258\" data-end=\"5281\"\u003e Workspaces, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5282\" data-end=\"5329\"\u003e\n\n\u003cp data-start=\"5284\" data-end=\"5329\"\u003e The consultation rooms or closed offices.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5331\" data-end=\"5524\"\u003e During installation, our team pays particular attention to suspension, vibration isolation and balancing of ducts to avoid any long-term noise nuisance.\u003c\/p\u003e\n\n\u003chr data-start=\"5526\" data-end=\"5529\"\u003e\n\n\u003ch2 data-start=\"5531\" data-end=\"5579\"\u003e Installation details that make all the difference\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5581\" data-end=\"5621\"\u003e Electrical and technical parameters\u003c\/h3\u003e\n\n \u003cp data-start=\"5622\" data-end=\"5686\"\u003eThe system operates on a \u003cstrong data-start=\"5665\" data-end=\"5678\"\u003e220–230 V\u003c\/strong\u003e power supply, with: \u003c\/p\u003e\n\n\u003cul data-start=\"5687\" data-end=\"5879\"\u003e\n\n\u003cli data-start=\"5687\" data-end=\"5704\"\u003e\n\n\u003cp data-start=\"5689\" data-end=\"5704\"\u003e \u003cstrong data-start=\"5689\" data-end=\"5703\"\u003eMCA: 19 A\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5705\" data-end=\"5722\"\u003e\n\n\u003cp data-start=\"5707\" data-end=\"5722\"\u003e \u003cstrong data-start=\"5707\" data-end=\"5721\"\u003eMOP: 20 A\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5723\" data-end=\"5788\"\u003e\n\n\u003cp data-start=\"5725\" data-end=\"5788\"\u003e Compatibility with long pipe runs, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5789\" data-end=\"5879\"\u003e\n\n\u003cp data-start=\"5791\" data-end=\"5879\"\u003e Flexible installation in existing buildings without major modifications.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5881\" data-end=\"6015\"\u003e These features are particularly appreciated in renovation projects where the electrical infrastructure is already in place.\u003c\/p\u003e\n\n\u003ch3 data-start=\"6017\" data-end=\"6062\"\u003e Outdoor installation adapted to the climate\u003c\/h3\u003e\n\n\u003cp data-start=\"6063\" data-end=\"6409\"\u003e For heating, the outdoor unit must be properly elevated to manage snow accumulation and defrost drainage. At \u003cstrong data-start=\"6199\" data-end=\"6211\"\u003eAirGreen\u003c\/strong\u003e , we consistently apply these principles to preserve winter performance and system durability, especially in areas exposed to strong winds and heavy rainfall.\u003c\/p\u003e\n\n\u003chr data-start=\"6411\" data-end=\"6414\"\u003e\n\n \u003ch2 data-start=\"6416\" data-end=\"6471\"\u003eLogisVert subsidy: a concrete financial advantage\u003c\/h2\u003e\n\n\u003cp data-start=\"6473\" data-end=\"6691\"\u003e The \u003cstrong data-start=\"6476\" data-end=\"6523\"\u003eELIOS 24,000 BTU Pancake fan coil unit\u003c\/strong\u003e is eligible for the \u003cstrong data-start=\"6544\" data-end=\"6580\"\u003eLogisVert provincial subsidy\u003c\/strong\u003e , which can reach up to \u003cstrong data-start=\"6600\" data-end=\"6611\"\u003e$2,376\u003c\/strong\u003e depending on the applicable conditions. We support our customers every step of the way: \u003c\/p\u003e\n\n\u003cul data-start=\"6692\" data-end=\"6779\"\u003e\n\n\u003cli data-start=\"6692\" data-end=\"6715\"\u003e\n\n\u003cp data-start=\"6694\" data-end=\"6715\"\u003e Technical validation, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6716\" data-end=\"6744\"\u003e\n\n\u003cp data-start=\"6718\" data-end=\"6744\"\u003e Administrative compliance, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6745\" data-end=\"6779\"\u003e\n\n\u003cp data-start=\"6747\" data-end=\"6779\"\u003e Preparation and monitoring of the file.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6781\" data-end=\"6885\"\u003e This approach reduces delays and avoids often costly errors in grant applications.\u003c\/p\u003e\n\n\u003chr data-start=\"6887\" data-end=\"6890\"\u003e\n\n\u003ch2 data-start=\"6892\" data-end=\"6937\"\u003e Concrete examples of AirGreen installations\u003c\/h2\u003e\n\n\u003cp data-start=\"6939\" data-end=\"7101\"\u003e In \u003cstrong data-start=\"6941\" data-end=\"6957\"\u003eBoucherville\u003c\/strong\u003e , we installed this system in a multi-unit residential building where mechanical space was extremely limited. After a full season: \u003c\/p\u003e\n\n\u003cul data-start=\"7102\" data-end=\"7265\"\u003e\n\n\u003cli data-start=\"7102\" data-end=\"7165\"\u003e\n\n\u003cp data-start=\"7104\" data-end=\"7165\"\u003e The occupants noted an improvement in thermal comfort. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7166\" data-end=\"7203\"\u003e\n\n\u003cp data-start=\"7168\" data-end=\"7203\"\u003e Energy costs have decreased,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7204\" data-end=\"7265\"\u003e\n\n \u003cp data-start=\"7206\" data-end=\"7265\"\u003eNo noise or condensation problems were reported.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7267\" data-end=\"7475\"\u003e In \u003cstrong data-start=\"7269\" data-end=\"7286\"\u003eMontreal North\u003c\/strong\u003e , the ELIOS Pancake made it possible to efficiently air-condition a commercial space without altering the existing structure, while respecting the aesthetic constraints imposed by the owner.\u003c\/p\u003e\n\n\u003chr data-start=\"7477\" data-end=\"7480\"\u003e\n\n\u003ch2 data-start=\"7482\" data-end=\"7525\"\u003e Why entrust your project to AirGreen\u003c\/h2\u003e\n\n\u003cp data-start=\"7527\" data-end=\"7566\"\u003e Choosing \u003cstrong data-start=\"7535\" data-end=\"7547\"\u003eAirGreen\u003c\/strong\u003e means ensuring: \u003c\/p\u003e\n\n\u003cul data-start=\"7567\" data-end=\"7796\"\u003e\n\n\u003cli data-start=\"7567\" data-end=\"7614\"\u003e\n\n\u003cp data-start=\"7569\" data-end=\"7614\"\u003e From a \u003cstrong data-start=\"7575\" data-end=\"7613\"\u003eteam of experienced refrigeration technicians\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7615\" data-end=\"7674\"\u003e\n\n\u003cp data-start=\"7617\" data-end=\"7674\"\u003e With \u003cstrong data-start=\"7623\" data-end=\"7673\"\u003e$5,000,000 in liability insurance\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7675\" data-end=\"7733\"\u003e\n\n\u003cp data-start=\"7677\" data-end=\"7733\"\u003e \u003cstrong data-start=\"7680\" data-end=\"7701\"\u003eTransparent pricing\u003c\/strong\u003e , communicated before the work begins, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7734\" data-end=\"7796\"\u003e\n\n\u003cp data-start=\"7736\" data-end=\"7796\"\u003e From technical support from the quote to commissioning.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7798\" data-end=\"7969\"\u003e We don't just install a unit. We design an HVAC solution tailored to your building, your actual usage, and Quebec's climatic conditions.\u003c\/p\u003e\n\n\u003chr data-start=\"7971\" data-end=\"7974\"\u003e\n\n\u003ch2 data-start=\"7976\" data-end=\"8009\"\u003e Conclusion\u003c\/h2\u003e\n\n \u003cp data-start=\"8011\" data-end=\"8415\"\u003eThe \u003cstrong data-start=\"8014\" data-end=\"8089\"\u003eELIOS 24,000 BTU ultra-slim (pancake) heat pump fan coil unit\u003c\/strong\u003e is a suitable solution for projects where discretion, winter performance, and installation flexibility are essential. When properly sized and installed, it perfectly meets the requirements of buildings in \u003cstrong data-start=\"8333\" data-end=\"8345\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"8347\" data-end=\"8356\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"8358\" data-end=\"8371\"\u003eLongueuil\u003c\/strong\u003e , the \u003cstrong data-start=\"8379\" data-end=\"8392\"\u003eNorth Shore\u003c\/strong\u003e , and the \u003cstrong data-start=\"8402\" data-end=\"8414\"\u003eSouth Shore\u003c\/strong\u003e .\u003c\/p\u003e\n\n \u003cp data-start=\"8417\" data-end=\"8727\"\u003eFor a \u003cstrong data-start=\"8434\" data-end=\"8458\"\u003edetailed quote\u003c\/strong\u003e , a \u003cstrong data-start=\"8464\" data-end=\"8489\"\u003epersonalized analysis\u003c\/strong\u003e , or \u003cstrong data-start=\"8497\" data-end=\"8546\"\u003etechnical advice tailored to your situation\u003c\/strong\u003e , contact \u003cstrong data-start=\"8577\" data-end=\"8629\"\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e directly. Our team will support you rigorously and transparently at every stage of your HVAC project.\u003c\/p\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51954112233764,"sku":"GPHLA24R4AS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Extra-flatfancoilconvector_Pancake_-ELIOS_61452caf-ef38-4221-866a-d44bc329ef03.png?v=1769969055","url":"https:\/\/airgreen.ca\/en\/products\/ventilo-convecteur-extra-plat-de-thermopompe-elios-24-000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}