Installation d’une Sharp ZU1 thermopompe murale à Saint-Léonard (Montréal)
Reading time: 6'

Installation of a Sharp ZU1 wall-mounted heat pump in Saint-Léonard (Montreal)

Winter installation on blond brick: performance in extreme cold and optimized snow clearance

In Saint-Léonard , an area known for its blond brick plexes and narrow side walkways, we have just installed a Sharp ZU1 wall-mounted heat pump . The work took place in real winter conditions, with snow on the ground , which allowed us to apply our best practices for frost management and clearances around the condenser. The result: a clean, robust HVAC system ready to provide four-season comfort .

Owner's objectives and site constraints

Our client wanted:

  • air-condition the main floor in the summer and support heating in the winter;

  • reduce energy costs related to electric baseboard heaters;

  • preserve traffic in the side aisle and avoid floor clutter.

The site presented several typical constraints: nearby basement windows , snow accumulation along the wall, and brick masonry requiring suitable anchors. We therefore opted for installation on galvanized wall brackets at a height calculated to remain sheltered from snowdrifts, while respecting service clearances.

Why the Sharp ZU1 range

The Sharp ZU1 is a must-have for Montreal homes looking for a balance between performance, quietness and durability:

  • Inverter compressor for fine modulation and measurable savings ;

  • Extreme cold performance : capacity maintained down to around −25°C , ideal for the local climate;

  • R-32 refrigerant , less impactful than the old R-410A;

  • Sharp's own Plasmacluster air treatment for a healthier interior;

  • Controlled acoustics , essential in side aisles and near openings.

The capacity chosen falls within the usual range of 12–18 k BTU , depending on the thermal loads of the floor and the distribution of the rooms.

Outdoor installation: stability, security and aesthetics

The condenser is securely mounted on wall brackets with anti-vibration pads and stainless steel bolts. This configuration:

  • keeps the unit out of the snow and splash zone ;

  • limits the transmission of vibrations to the structure;

  • facilitates natural de-icing and seasonal maintenance.

An upper support (high brackets) is provided for the addition of a snow guard if necessary, when the roof creates ice falls during thawing. The refrigeration connections exit at the rear of the unit and are insulated along their entire length; they are neatly gathered against the facade to reduce the visual footprint. The external disconnect and cable protection follow the current electrical requirements for rapid de-energization during maintenance operations.

Visible details and best practices applied

  • Height of approximately 1 m above finished ground for snow clearance;

  • Wide plate brackets , anchored in the brick with suitable sealing;

  • Level and plumb checked for defrost drain;

  • Radius of curvature of the connections respected to preserve the integrity of the tubes;

  • Free area in front of the exchanger to ensure air flow .

Route of connections and management of condensates

Inside, the wall-mounted head serves the living area. The refrigeration path favors a short trajectory with a minimum of elbows in order to reduce pressure losses. Condensate management in air conditioning mode is provided by a dedicated drain with a continuous slope; when the interior configuration requires it, we integrate a silent lifting pump and a non-return valve to make the evacuation reliable. These choices prevent any infiltration near the basement windows .

Steps to a Successful Winter HVAC Installation

  1. Thermal survey and selection of suitable capacity (surface, insulation, exposure).

  2. Marking anchors in the brick and checking clearances.

  3. Controlled slope drilling , sleeve and peripheral sealing .

  4. Installation of brackets , level adjustment and installation of the condenser with anti-vibration.

  5. Drawing of connections , continuous insulation, mechanical fixing, UV and weather protection.

  6. Brazing/crimping , nitrogen infiltration , deep vacuum (< 500 microns), then opening of the fluid.

  7. Controls : pressures, temperatures, intensity, delta T blowing/return, defrost test.

  8. Commissioning : remote control configuration, HVAC usage and maintenance tips.

Even in cold weather, these steps ensure smooth start-up and stable heating .

Measured results and perceived comfort

Upon activation, the Sharp ZU1 delivers gentle, continuous heat. Inverter modulation prevents short cycles , improves seasonal efficiency , and reduces wear and tear. Outdoors, noise levels remain very low , which is important for side walkways often close to neighbors.

HVAC Maintenance: Recommended Schedule

  • Internal filters : clean every 4–8 weeks during periods of heavy use.

  • Outdoor battery : rinse with gentle jet in spring and fall.

  • Annual inspection : refrigerant check, electrical tightening, condensate test, exchanger cleaning.

  • Winter : maintain clearance in front of the condenser and check for ice accumulations; add a snow guard if the roof warrants it.

Tips for maximizing savings

  • In heating , choose a moderate setting and let the inverter work continuously.

  • Use the head sweep to push air into the hallway and adjacent rooms.

  • In summer, activate the dehumidification mode on heavy days to improve comfort at a higher setpoint.

  • Combine the heat pump with small sealing actions (bottom of doors, caulking) to amplify the gains.

Grants and support

The Sharp ZU1 (R-32) range is among the energy-efficient solutions generally eligible for assistance programs in Quebec, subject to performance criteria. We support our customers in Montreal, Laval, Longueuil, North Shore and South Shore : estimating savings, preparing files and submitting applications, in order to accelerate the return on investment .

Pitfalls to avoid (AirGreen feedback)

  • Undersized capacity: discomfort and excessive consumption.

  • Insufficient clearances : recurring frost, noise, drop in performance.

  • Neglected connection protection : premature aging of insulation.

  • Absence of external disconnect : non-compliance and complicated maintenance.

  • Improvised condensate management : risks of infiltration near basement windows.

What this installation demonstrates

  • Mastery of masonry anchors and snow-free installation;

  • Aligned finishes and compact routing of connections to preserve aesthetics;

  • Reliable winter starting and immediate comfort;

  • A complete service , from thermal study to commissioning , then to HVAC maintenance .

Conclusion

The Sharp ZU1 wall-mounted heat pump installed in Saint-Léonard illustrates our requirement: a precise, durable HVAC installation designed for the Montreal climate. Between energy savings , silence and integration on a blond brick facade, we deliver a system ready to ensure lasting comfort all year round. For similar projects in Montreal , Laval , Longueuil , on the North Shore as well as on the South Shore , our team applies the same rigor and supports each owner in subsidies and maintenance.