Wall-mounted heat pumps

Wall heat pumps for a Laurentians chalet: FUJITSU AIRSTAGE, GREE and LG in the Mont-Tremblant cold

12 min to read it all

The gist

In Mont-Tremblant, the design temperature is −30.6 °C. The page takes the same house as in Montréal to estimate a chalet's heating, then shows what FUJITSU AIRSTAGE, GREE and LG publish from −15 to −35 °C for three 12,000 BTU wall units sold by AirGreen. No ranking.

Read the details

In detail

Comparison · Chalet in the Laurentians · 12,000 BTU

A chalet in Mont-Tremblant: three wall units at the design cold, with the published numbers

In Mont-Tremblant, the January design temperature is −30.6 °C, against −23.1 °C in Montréal (Natural Resources Canada, St-Jovite station). This page sets three 12,000 BTU R-32 wall units sold by AirGreen side by side, in alphabetical order of brand, and shows what each manufacturer and NEEP publish at these temperatures. No ranking: the numbers, with their source.

Design temperature −30.6 °C5,103 degree-days at St-JoviteSources: manufacturers, NEEP and NRCanNo ranking
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU wall heat pump FUJITSU AIRSTAGE

ORION XLTH 12,000 BTU

Heating stated down to −26 °C, with no automatic shutdown below
ASUH12KZAS + AOUH12KZAH1 · AHRI 214888802
See the product page
GREE EXTRÊME R32 12,000 BTU wall heat pump GREE

EXTRÊME R32 12,000 BTU

Heating stated down to −30 °C
GWH12AVDXE-D6DN***/I + GWH12AVDXE-D6DNA1B/O · AHRI 215386290
See the product page
LG ARTCOOL DELUXE R32 12,000 BTU wall heat pump LG

ARTCOOL DELUXE R32 12,000 BTU

Heating stated down to −35 °C
KNSAL121A + KUSAL121A · AHRI 216368960
See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec's Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. This module is calculated for Montréal; the next section applies the same method to a chalet in Mont-Tremblant. The module shows two of them, in alphabetical order; the table that follows shows all three. Electric baseboards serve as the reference point.

All three models, same settings as above

The table follows the price and hours chosen in the module. Same method, same conditions; only each certificate's HSPF2 Region V and SEER2 change.

Winter · heating

Summer · cooling

Full year

How this amount is calculated
  1. Heat needed over the winter. A zone with a heat loss of 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day ("Heating" slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down when the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The chalet

The same house, in Montréal and in Mont-Tremblant

The climate data come from the same source as the cost module: Natural Resources Canada's HOT2000 map. We take the module's house, whose heat loss reaches 12,000 BTU/h at −23.1 °C, and place it in Mont-Tremblant: it loses the same heat per degree of difference, but the winter there is longer and colder.

Two stations, one method

January design temperature (2.5%) and heating degree-days below 18 °C.

Montréal Intl
−23.1 °Cdesign temperature
degree-days4,167
St-Jovite (Mont-Tremblant)
−30.6 °Cdesign temperature
degree-days5,103

Heating the chalet all winter

Same method as the cost module, same prices and hours as chosen above; only the station changes. Heat needed: kWh in Montréal, kWh in Mont-Tremblant.

in Montréalin Mont-Tremblant

At Mont-Tremblant's design cold

At −30.6 °C, the same house loses about BTU/h (12,000 × 48.6 ÷ 41.1). Here, for each unit, is the published value closest to that temperature, with its source. The bars do not say whether a unit is enough: a chalet's actual heat loss is calculated on site, and backup heat (the existing baseboards, for example) covers the difference.

Deep cold

From −15 to −35 °C, what each manufacturer and NEEP publish

Each point comes from a certificate published by NEEP or from a manufacturer document, at its own temperature. Between two published points, the table gives the range with both ends; nothing is calculated between the points. The −30 °C line is 0.6 °C away from Mont-Tremblant's design temperature.

Three units, three coldest points. NEEP certifies the ORION XLTH down to −26.1 °C, the EXTRÊME R32 down to −30 °C and the ARTCOOL DELUXE R32 down to −35 °C. LG also publishes, in its brochure, the capacity at −18, −20 and −25 °C, as a percentage of the 13,000 BTU/h rated capacity. GREE publishes a percentage curve with no stated base (Airy Inverter R32 service manual), not converted here.
Features

What matters when the chalet is empty

FUJITSU AIRSTAGE brochure FG8153C; GREE Canada EXTRÊME R32 brochure (032025), GREE AIRY R32 brochure and Airy Inverter R32 service manual; LG brochure PO_LG_R32_ArtCool_Mirror_Deluxe_04_25_CA. "Not published by the manufacturer" means the document consulted is silent: the feature may exist without being described there.

FeatureORION XLTHEXTRÊME R32ARTCOOL DELUXE
Automatic shutdown in deep coldNo automatic shutdown stated below −26 °C Brochure FG8153CNot published by the manufacturerNot published by the manufacturer
Minimum heat modeYes; "Minimum Heat" mode named in the brochureNot published by the manufacturer in the EXTRÊME brochureNot published by the manufacturer in the brochure
Restart after a power failureYes; automatic restartYes; resumes the last settings Service manualNot published by the manufacturer in the brochure
Wi-Fi and appYes; built in, AIRSTAGE Mobile appYes; Wi-Fi listed in the brochureWi-Fi not named in the brochure; the freeze-cleaning function is marked "ThinQ only"
Heated base panYes; 150 W Declared to NEEPYes; 72 W, below 1 °C or during defrostYes; 90 W Declared to NEEP
Presence sensorYes; "Occupancy" modeNot published by the manufacturerYes; adjusts airflow and switches to energy saving when no one is detected
DefrostAutomatic"Intelligent" preheating and defrost GREE AIRY R32 brochureNot published by the manufacturer in the brochure
Filter and cleaningWashable filterWashable filters"Auto Clean+": dries the indoor unit's heat exchanger
CompressorInverterG10 Inverter, two-stage variable speedTwin rotary, inverter
Sound

Indoor unit noise, according to each manufacturer

Each dot is a level published for one fan speed, in cooling. GREE publishes eight levels, from 19 to 43 dB(A), without naming the speeds: only its two extremes are shown. LG publishes four speeds, from "very low" to "high".

Indoor unit, cooling

dB(A), from lowest to highest

dB

Night at the chalet. Away from the city, background noise is low: each unit's slowest speed is the number to look at for a bedroom. The left dot on each line gives it.

No podium. FUJITSU AIRSTAGE, GREE and LG each measure their own way; compare one speed with another on the same line, not one brand with another.

Levels published by each manufacturer, in cooling; different methods, read line by line.

Installation

On the chalet wall, and outside under the snow

The three indoor units are drawn at their published width. Set the free width of your wall: the lane turns yellow when the unit is wider than the space. Outside, the outdoor unit must stay above the accumulated snow; the height of its stand is decided at the visit.

42 in

Each lane stands for 60 in of wall; the light zone in the centre is the chosen free width. Widths: brochure FG8153C, GREE Canada brochure 032025, LG brochure 04/25.

InstallationORION XLTHEXTRÊME R32ARTCOOL DELUXE
Maximum piping length82 ft131.2 ft Brochure; the manual prints 65.6 ft65.6 ft
Precharged length49 ft24.6 ft; 0.2 oz/ft beyond41 ft; 0.16 oz/ft beyond
Maximum height difference66 ft82 ft Brochure; the manual prints 32.8 ft39.4 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in1/4 – 3/8 in
Indoor unit W × H × D, weight38 9/16 × 11 × 9 7/16 in, 28 lb38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb35 1/4 × 12 3/32 × 9 1/4 in, 24.3 lb
Outdoor unit W × H × D, weight31 7/16 × 24 7/8 × 11 7/16 in, 86 lb34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb34 1/4 × 25 19/32 × 13 in, 99.2 lb
Electrical protection15 A15 A maximum; MCA 11 A20 A maximum; MCA 15 A
Dehumidification1.9 L/h1.4 L/h1.7 L/h 3.59 pints/h in the brochure
Stated heating / cooling range−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C−35 to 18 °C / −10 to 48 °C Heating as wet bulb according to LG
Certified data

The values on the three certificates

For a chalet, the −15 °C rows and each certificate's last point say the most. AHRI certificates published by NEEP, consulted November 17, 2026; capacities and COPs are compared at the same test temperature.

Certified valueORION XLTHEXTRÊME R32ARTCOOL DELUXE
Certificate
AHRI certificate · NEEP record214888802 · 392122215386290 · 389444216368960 · 383065
RefrigerantR-32R-32R-32
ENERGY STAR · cold climateYes; listing 3554345Yes; listing 3621214Yes; per NEEP
Seasonal efficiencies
SEER230.529.525.5
EER21615.213.8
HSPF2 Region IV12.71011.2
HSPF2 Region V10.188.4
Heating, same test temperatures
Capacity at 8.3 °C, min. / rated / max. (BTU/h)3,500 / 16,000 / 23,6003,270 / 12,200 / 16,2003,070 / 13,000 / 20,000
COP at 8.3 °C, min. / rated / max.5.13 / 4.64 / 3.075.04 / 4.53 / 3.774.74 / 4.10 / 2.93
Capacity at −8.3 °C, min. / rated / max. (BTU/h)2,200 / 10,000 / 18,7002,800 / 13,000 / 13,0002,627 / 8,400 / 16,820
Capacity at −15 °C, min. / rated / max. (BTU/h)1,950 / 16,600 / 16,6002,600 / 12,200 / 12,2002,388 / 14,700 / 14,700
COP at −15 °C, min. / rated / max.3.36 / 2.16 / 2.164.23 / 2.00 / 2.001.79 / 2.05 / 2.05
Coldest point on each certificate (different temperatures)
Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)−35 °C (−31 °F)
Max. capacity (BTU/h)12,2008,5009,100
COP at max. capacity1.811.751.33

Nothing is highlighted. The coldest points, at −26.1, −30 and −35 °C, frame Mont-Tremblant's design temperature (−30.6 °C) in different ways: the "The chalet" section takes them one by one.

Questions

What we get asked for a chalet

Is a 12,000 BTU wall unit enough for my chalet?

That depends on the chalet's heat loss, which is calculated on site: floor area, insulation, windows, ceiling height. The "At Mont-Tremblant's design cold" section shows what each manufacturer publishes near −30.6 °C for a given house; backup heat, such as the existing baseboards, covers what the heat pump does not supply.

What happens after a power failure?

FUJITSU AIRSTAGE states an automatic restart; the GREE service manual says the unit resumes its last settings. The LG brochure consulted does not mention it. If the chalet stays without power for a long time, the heat pump does not heat: the electrical installation and the backup heat decide the protection against freezing.

Can the chalet be kept at a minimum when it is empty?

The FUJITSU AIRSTAGE brochure names a "Minimum Heat" mode. The GREE EXTRÊME and LG brochures consulted do not name an equivalent mode; a low set point remains possible with the remote or the app, within the setting range published by each manufacturer.

Why the LG ARTCOOL DELUXE and not the Mitsubishi from the old article?

AirGreen does not sell Mitsubishi. The page compares units that are sold, of the same type and capacity; the 12,000 BTU LG ARTCOOL DELUXE R32 is certified by NEEP down to −35 °C.

Does the warranty apply to a chalet?

The page does not compare warranties: their terms, including for a secondary residence, depend on the manufacturer, registration and purchase date. The documents for the chosen model come with the quote.

Does LogisVert apply to a chalet?

The program's conditions, including for a secondary residence, and the list of eligible models are Hydro-Québec's on the date of purchase. We check them for the model and address in the quote; no amount is promised on this page.

All three are on AirGreen's website.

Our estimator comes to measure the room and the wall for free, and looks with you at where to place the outdoor unit in relation to the snow. Written quote within 24 hours.