Installation d’un climatiseur mural LG Neo Plasma à Rosemont–La Petite-Patrie
Reading time: 7'

Installation of an LG Neo Plasma wall-mounted air conditioner in Rosemont–La Petite-Patrie

A residential construction site designed for clean air, sound discretion and perfect integration

At AirGreen , we treat each HVAC installation like a small interior design project: the unit must provide daily comfort, while blending into the decor and respecting the building's constraints. In this condo in Rosemont–La Petite-Patrie , we installed an LG Neo Plasma wall-mounted air conditioner , a solution known for its excellent air quality and discreet operation—all sought-after assets in Montreal homes where space is precious and tranquility is essential.

The client's context and performance objectives

The owner previously used a noisy and power-hungry handheld device. He wanted to:

  • uniform cooling of living areas;

  • a reduction in noise level ;

  • controlled energy consumption during summer peaks;

  • a visually discreet device, aligned with the straight lines of the wall and the existing ceiling drop.

After thermal assessment of the volumes (open living room-kitchen + corridor), we validated the choice of a wall-mounted air conditioner of suitable capacity, with Inverter technology and Neo Plasma filtration from LG , known for capturing fine dust and allergens.

What we actually install

  • Equipment type : wall-mounted air conditioner (mini-split).

  • Brand : LG .

  • Range : Neo Plasma (advanced electrostatic filtration).

  • Technology : Inverter compressor to modulate power; soft start electronics, better efficiency and longevity.

  • Comfort : low noise level from the interior head; multi-louver air diffusion to avoid direct air currents.

  • Air quality : filtration and ionization system designed to improve the capture of suspended particles.

Please note: the installed model is dedicated to air conditioning . For winter supplemental heating needs, we also offer our range of extreme cold wall-mounted heat pumps (R-32/R-454B), eligible for certain subsidies.


Careful integration into a Montreal condo

Interior positioning and aesthetics

The interior head was installed under a ceiling drop , in order to take advantage of sufficient clearance for air intake and optimal diffusion towards the living area. We have:

  • center the device relative to the wall for a balanced visual reading;

  • checked the recommended top and side clearances ;

  • validated the absence of obstacles which could disrupt the sweeping of the shutters.

A light touch-up of paint was applied around the plate after fixing (micro-adjustments of screws and filling), then clean finishing to maintain the homogeneity of the wall. The objective is to make the unit almost invisible in everyday life: the gaze falls on the room, not on the device.

Refrigerant and electrical path

The route was designed to remain short and straight , a guarantee of efficiency and reliability over time:

  • Wall crossing behind the unit, with controlled slope drilling (≈ 5–10 mm/m) for the gravity drain .

  • Holes sealed and plugged on the outside to prevent any air or moisture infiltration.

  • Set of connections (fridge + communication + power supply) grouped in a discreet, light-colored facade capping , in order to harmonize the whole with the building's masonry.

  • Estimated total line length ≈ 2.5–3.5 m, within the ideal range to limit pressure losses and maintain factory characteristics.

On the power supply side, we comply with CSA/CEC standards and selectivity of protections. A dedicated circuit breaker is assigned to the outdoor unit; the communication cable is laid away from sources of interference. These details ensure stable operation and impeccable electrical safety .

Condensate management: reliability above all

In this project, the condo's configuration allows for gravity drainage —always preferred for its simplicity and robustness. We checked:

  • the slope from the inner head tank to the outlet point;

  • the cleanliness of the tube and its insulation to avoid parasitic condensation;

  • accessibility for future interviews.

When the architecture does not allow it, we install silent condensate pumps with safety tanks. Here, gravity remains the best ally: less mechanics, less risks .

Discreet exterior that respects the building

Without any visual clutter, the ducts exit at the rear of the unit. The capping follows the existing relief, which:

  • protects connections from UV rays, rain and shocks;

  • structure the facade aesthetics ;

  • simplifies the annual inspection .

Our fasteners are sized for Montreal freeze-thaw cycles. Penetrations are sealed with extreme cold compatible mastic.


Result: immediate comfort, silence and cleaner air

Upon commissioning:

  • the temperature drops quickly in the day zone, then stabilizes thanks to the Inverter ;

  • the noise level remains very contained, even when increasing the revs;

  • Neo Plasma filters improve the perception of fresh air, a real plus for urban living.

The customer confirmed a significant reduction in power consumption compared to his old portable system, and better sleep quality thanks to the night mode and gentle blowing .


AirGreen Best Practices for Condos in Montreal, Laval, Longueuil, North Shore and South Shore

Sizing and choice of location

  • Adjust the capacity (BTU) to the actual open area and sunlight;

  • avoid nearby obstacles (beams, low hangings, tall furniture) which break the air flow;

  • aim for a flow directed towards the passage areas to homogenize the temperature.

Installation and finishing

  • Perfectly level plate for drainage;

  • Silent blocks and controlled tightening to eliminate vibrations;

  • Vapor barriers and insulation on cold connections to prevent any condensation on the interior route.

Commissioning and configuration

  • Deep vacuum (500 microns) and stability verified;

  • Weighing the fluid when the length is outside the standard values;

  • Mode calibration : Auto/Cool/Dry, fan speed and louver orientation according to room geometry.

HVAC Maintenance: The Key to Lifespan

  • Clean filters every 4 to 8 weeks during periods of heavy use;

  • Annual inspection : exchanger, condensate tray, vacuum, electrical checks;

  • Battery hygiene : gentle treatment to maintain performance and limit odors.


About subsidies and alternatives for extreme cold

A wall-mounted air conditioner dedicated to cooling is generally not eligible for Quebec grant programs. If you are looking for a four-season unit with efficient heating down to -25/-30 °C , our recent wall-mounted heat pumps ( R-32 or R-454B refrigerants) are a more easily eligible investment , with high efficiencies and a reduced carbon footprint . We often recommend this option during a comprehensive renovation or replacement of aging equipment.


Why entrust your installation to AirGreen?

  • A team dedicated to wall-mounted air conditioners and wall-mounted heat pumps for apartments, plexes and houses;

  • A proven methodology : thermal load study, implementation, instrumented commissioning;

  • Fast, local after-sales service with parts and preventive maintenance;

  • Coverage of all of Greater Montreal, Laval, Longueuil, North Shore and South Shore .

Are you considering a discreet and efficient HVAC installation in a condo or complex? We evaluate your configuration, compare several brands (LG, Gree, Fujitsu, Midea, Sharp, etc.), and provide a clear quote with performance scenarios and maintenance options.

Leave a comment