Four-season comfort, energy efficiency and careful finishing in a typical Rosemont apartment
Client context and objectives
At AirGreen , we are working on a bright home in the Rosemont–La Petite-Patrie sector of Montreal . The owner wants a compact and efficient HVAC solution to cool in the summer, moderate the shoulder seasons and support supplemental heating in the winter, without invasive work. We recommend installing a latest-generation Gree wall-mounted heat pump with R-32 refrigerant , sized for an open living space of approximately 35–45 m² (typical profile 12,000 BTU).
Why Gree in R-32 for this project
-
High energy efficiency : R-32 provides better seasonal efficiencies and a reduced refrigerant charge compared to older generations of R-410A.
-
Extreme cold : recent Gree ranges offer stable operation down to -25°C , or even -30°C depending on the series; ideal for the Montreal climate.
-
Quiet and comfortable : the interior head provides discreet ventilation and even diffusion thanks to the motorized fins and wide blowing profile.
-
Potential eligibility for assistance programs when Energy Star and low temperature performance criteria are met (to be validated on a case-by-case basis for Montreal, Laval, Longueuil, North Shore, South Shore ).
Sizing and capacity selection
We prioritize precise sizing, based on the envelope, orientation and uses:
-
9,000–12,000 BTU : Open bedrooms and living rooms up to ~40 m².
-
18,000 BTU : Larger living areas or unfavorable orientation.
-
In the case of multiple zones, a MultiZone heat pump may be recommended; here, a single wall head meets the need.
Installation details — clean, short, and gravity-based
-
Positioning : interior head placed high, centered on the load-bearing wall for optimal diffusion and to free up circulation.
-
Single hole (~65 mm) with sealed bulkhead ; refrigerant connections, drain and supply pass directly through the rear of the unit (so-called “back-to-back” configuration).
-
Condensate drainage : gravity , avoiding the pump and reducing maintenance.
-
Short exterior route (estimated 1.5 to 2.5 m), limiting pressure losses and improving aesthetics.
-
Finish : discreet capping on the outside, stainless steel fixings, insulated collars, UV tape; inside, no visible trunking, for neat integration .
-
Power supply : dedicated circuit according to the rating required by the nameplate; circuit breaker and cable section comply with the Quebec Building Code.
Key stages of the project
-
Protection and marking : tarpaulins, laser markings to ensure the horizontality of the supports.
-
Drilling and sealing : draining angle towards the outside to prevent any water return.
-
Installing the plate and hanging the wall head; checking the alignment of the shutters.
-
Bending and flaring of copper tubes, brazing prohibited on the visible interior portion; torques on the dynamometer .
-
Deep vacuum (< 500 microns) and nitrogen leak test .
-
Commissioning : checking intensities, supply/return temperatures, and setting modes (cooling/heating, dehumidification).
-
Customer discount : explanations of use, HVAC maintenance settings, digital maintenance log.
Result obtained
-
Rapid temperature reduction in summer with uniform blowing throughout the room.
-
Comfortable maintenance during the off-season, reducing the need for the main heating system.
-
Controlled acoustics : very low noise level at low speeds, ideal for teleworking.
-
Aesthetics : no visible interior chute, clean wall facade.
Recommended HVAC maintenance
-
Filters : Rinse every 4–8 weeks during periods of heavy use.
-
Indoor battery : professional cleaning and annual mild biocide treatment .
-
Outdoor condenser : clear leaves/snow, wash the exchanger in spring.
-
Annual inspection by our technicians: pressure check, fittings, insulation, drain and parameter updates.
Tips for maximizing savings
-
Maintain a stable setpoint (e.g. 23–24°C in summer) to avoid short cycles.
-
Use the dehumidification mode when the air is heavy: the feeling of comfort increases without overcooling.
-
Program the shutters to avoid direct blowing onto living areas.
-
In winter, activate the extreme cold function when available; automatic defrosting managed by the unit.
Things to watch out for in Rosemont apartments
-
Masonry walls : careful drilling and sealing to avoid water bridges and preserve insulation.
-
Narrow backyards : choose a well-ventilated outdoor location that is clear of snow.
-
Structure-borne noise : interposition of silent blocks and compliance with tightening torques to eliminate any transmitted vibration.
Why entrust your HVAC installation to AirGreen?
-
Dimensioning engineering adapted to Montreal buildings.
-
Certified technicians and commissioning tools (vacuum, micron meter, nitrogen).
-
Responsive after-sales service , HVAC maintenance contracts and seasonal optimization advice.
-
Grant support : we check the eligibility of models and files for Montreal, Laval, Longueuil, North Shore, South Shore .
Summary technical sheet (example of configuration installed)
-
Type : single-zone wall-mounted heat pump .
-
Brand : Gree (recent R-32 platform).
-
Typical capacity : 12,000 BTU.
-
Operating range : up to −25°C (depending on the series).
-
Power supply : 208–230 V, dedicated circuit.
-
Installation : rear drilling, gravity drain , short connections, discreet finish.
Are you considering a similar HVAC installation in Montreal or the surrounding area? Our team will guide you from sizing to commissioning , with clean and sustainable execution.