Installation d’une Sharp (série ZU1) thermopompe murale à Villeray–Saint-Michel–Parc-Extension
Reading time: 6'

Installation of a Sharp (ZU1 series) wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension

Quiet comfort and understated finishes: careful vertical installation, gravity drain and simplified maintenance

AirGreen Feedback — What We're Putting in Place
In an apartment in Villeray–Saint-Michel–Parc-Extension , our team is installing a Sharp wall-mounted heat pump ( ZU1 range, R-32 refrigerant) to provide efficient heating in mid-season and discreet air conditioning in the summer. The client wants to keep the wall clean, limit drilling and ensure rapid HVAC maintenance . We propose a high installation and a vertical route inside the home, protected by discreet white ducting , which connects to a low outlet with a gravity drain .

The intervention framework

  • Typical urban housing with existing electric baseboards and headroom.

  • Low noise level requirement (adjoining rest area).

  • Neutral interior finish (white walls, molded frame): visual integration is a priority.

  • Easy access to the wall leading to the outside for a short and readable connection route.

Why the Sharp (ZU1 series) in R-32?

  • Next-generation R-32 : better seasonal efficiency and reduced charge vs. R-410A.

  • Smooth start, smooth airflow , reliable electronics and clear diagnostics .

  • Compact and quiet interior design, ideal for homes in Montreal , Laval and Longueuil .

  • Compatibility with various usage profiles (off-season heating, summer cooling over extended periods).


Our installation method: cleanliness, slope and accessibility

Head positioning and air diffusion

The head is fixed at the top , above the circulation area, to optimize:

  • stratification in heating mode (blowed air which sweeps the ceiling then falls back down),

  • uniformity in air conditioning,

  • service access (dismantling of facade, cleaning of filters, temperature measurements).

The motorized shutter is set for a wide sweep, avoiding any direct current towards the rest area.

Protected vertical route and low exit

We create a vertical route for the connections (refrigerants + electricity + condensates) under white sheathing :

  • Bending radii respected to avoid tiring the copper.

  • Continuous insulation on the suction line to eliminate dew and losses.

  • Low outlet near the baseboard: a single hole , carefully sealed with a vapor barrier.

This short, straight route limits pressure losses, simplifies future interventions and keeps the wall visually clean .

Condensate management: gravity-based and reliable

The geometry of the place allows for a gravity drain :

  • Controlled slope from the exit of the tank to through the wall.

  • Regular fixings to avoid water pockets .

  • Clear water test at the end of the work to validate the flow.

In urban areas like Villeray , gravity reduces maintenance (no pump) and lowers acoustic risks.

Sealing and vacuum: our guarantees of durability

  • Nitrogen pressurization of lines during assembly to prevent oxidation.

  • Leak test then deep vacuum (≤ 500 microns) with stabilization and ascent control.

  • Fluid opening and load weighing checked according to the installed length.

Power supply and protections

  • Dedicated compliant circuit, clear identification of conductors, controlled earthing .

  • Checking the load current , voltages and direction of fan rotation .

  • Clearances respected for air circulation and safety.


Commissioning and customer settings

During commissioning, we proceed to:

  1. Measurement of blown/intake temperatures and flow balancing.

  2. Adjust the flaps to circulate the air along the ceiling and avoid dead zones.

  3. Activation of eco functions and standby settings.

  4. Express training: filter maintenance, reading indicators , good usage practices depending on the season.

The result observed on site: a rapid drop in the perceived temperature in summer and a uniform rise in heat in spring/autumn, with a very contained noise footprint .


Salient technical details of this pose

Lengths and drilling

  • Interior vertical of approximately 2 to 2.5 m up to a low wall crossing .

  • A single, perfectly sealed hole , vapor barrier and slope respected.

Finishing and integration

  • Discreet white sheathing that follows the angle of the wall and the baseboard.

  • Equidistant fasteners for clean alignment and no vibration.

  • Clearance under the head maintained for service .

Easy HVAC maintenance

  • Filters accessible from the front (routine 4–6 weeks in intensive use).

  • Drain path can be quickly checked (inspection and flushing).

  • Path identification for accelerated diagnostics .


AirGreen usage tips for a wall-mounted heat pump in urban housing

Seasonal adjustments

  • In winter , aim for a stable setting (few day/night differences) to benefit from the optimal COP .

  • In summer , keep 24–25°C and activate dehumidification mode when humidity exceeds ~55%.

  • Point the shutter slightly towards the ceiling for even air mixing.

Hygiene, noise and longevity

  • Clean filters frequently to maintain low sound pressure .

  • Leave 50 cm around the head for sweeping.

  • Schedule annual maintenance : evaporator cleaning, electrical tightening, insulation test, gravity flow check.

Grants and Compliance

Recent high-efficiency wall-mounted heat pumps operating on R-32 are often eligible for financial assistance programs in Quebec. We support our clients to validate eligibility and gather the required documents, whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore .


Concrete benefits for the occupant

  • 4-season comfort with soft, even diffusion.

  • Appreciable silence in the rest rooms.

  • Energy savings thanks to R-32 and eco settings.

  • Clean wall : aligned white cladding, discreet low outlet, a single drilling.


Why AirGreen for your HVAC installation in Montreal

  • Expertise in urban configurations (plexes, condos, townhouses).

  • Selection of recent brands (R-32 / R-454B) with parts available locally .

  • Rigorous quality procedure : nitrogen, deep vacuum, electrical tests, slope validation.

  • Structured after-sales service : HVAC maintenance reminders, seasonal optimization advice, priority assistance during heat waves and cold spells.


Quick Facts — Installation in Villeray–Saint-Michel–Parc-Extension

  • Type : wall-mounted heat pump (mini-split).

  • Brand : Sharp ( ZU1 , R-32 range).

  • Route : interior vertical under white sheathing , low outlet ; gravity drain .

  • Drilling : single, sealed and watertight.

  • Customer objective : silence, clean wall, minimal maintenance, 4-season comfort.

For a similar HVAC installation project in Montreal , Laval , Longueuil , on the North Shore or South Shore , our AirGreen team carries out a technical visit , provides a clear quote and ensures follow-up until the first interview .

Leave a comment

Please note, comments need to be approved before they are published.