Installation d’une Sharp ZU1 thermopompe murale à Villeray–Saint-Michel–Parc-Extension
Reading time: 7'

Installation of a Sharp ZU1 wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension

A perfectly integrated Sharp wall head for four-season comfort in a Villeray–Saint-Michel–Parc-Extension plex

In the heart of Villeray–Saint-Michel–Parc-Extension , we installed a Sharp ZU1 wall-mounted heat pump in a dwelling located on the upper floor of a Montreal plex. The client's objective was clear: to achieve stable comfort all year round , an impeccable aesthetic appearance in the main living area and controlled electricity consumption . Our AirGreen team took charge of the entire project, from the thermal assessment to commissioning , including the design of the refrigeration path and the protection of the building envelope .

The context: a bright living room, air diffusion and finishing constraints

The interior head is integrated into a light-colored central wall , close to the ceiling, in order to optimize air stratification and the blowing range. We have chosen a position which:

  • ensures top and side clearance in accordance with the manufacturer's recommendations for efficient air sweeping;

  • avoids obstacles (curtains, columns, light fixtures) and directs the flow towards the occupied area;

  • provides direct access to the hood for HVAC maintenance (filter cleaning, fan inspection, condensate tray check).

The motorized shutter on the front ensures even diffusion across the depth of the living room. The color and glossy finish of the device match the decor, while the high installation frees up wall space .

Why Sharp ZU1 for Montreal and its rugged winters

Sharp's ZU1 range is based on an inverter compressor and R-32 refrigerant, renowned for its energy efficiency. The power electronics finely modulates the capacity according to the thermal load, which results in:

  • a stable indoor temperature without overheating or overcooling;

  • a drop in consumption peaks ;

  • a contained noise level on the interior side.

The specific assets appreciated by our customers in Montreal , Laval , Longueuil , on the North Shore and the South Shore :

  • high seasonal efficiency in both air conditioning and heating;

  • intelligent defrosting that limits loss of comfort in cold weather;

  • advanced filtration and air purification function typical of Sharp units.

Capacity sizing and adequacy

We size each heat pump based on the home's thermal balance : insulation, orientation, glazed surfaces, air infiltration, and occupancy habits. In this project, the main room has an open volume towards a corridor; the capacity of the selected ZU1 covers the winter peak load while avoiding oversizing, guaranteeing:

  • long cycles and stable evaporation;

  • fewer “on/off” paces;

  • increased compressor durability .

Refrigerated route and careful drilling

From the wall head, we have planned a single drilling through the exterior wall with:

  • vapor barrier and peripheral sealant to maintain continuous airtightness;

  • controlled slope for gravity flow of the drain;

  • discreet white capping inside then UV-resistant outer protective sheath.

The connection length is kept short to reduce pressure losses and protect efficiency. We maintain a generous bend radius on the copper, place a service loop , and install regular clamps to absorb expansion and vibration. This care prevents whistling, rubbing, and micro-leaks in the medium term.

Power supply and safety

The indoor unit is connected to the electrical panel via a dedicated, protected circuit that complies with the nominal currents. Outdoors, the unit is equipped with a NEMA-type local disconnect suitable for weather conditions, in accordance with industry standards. We systematically check:

  • the tightening torque of the terminal blocks;

  • the voltage under load ;

  • grounding .

This rigor determines the reliability and safety of the installation over time.

Condensate management: priority to gravity

The wall-mounted head is installed to facilitate gravity drainage of condensate, a simple, quiet, and reliable solution. We avoid using a condensate pump when a natural slope is possible; this means less maintenance, less noise, and less risk of overflow. The pipe is insulated to prevent any parasitic condensation in cooling mode and wedged to stay away from furniture.

Commissioning and performance checks

During commissioning , our technicians apply a complete procedure:

  1. Deep vacuum and vacuum resistance control;

  2. Checking the fluid load according to the actual length;

  3. Measurement of temperature differentials at various ventilation flow rates;

  4. Superheat and subcooling control;

  5. Heating and cooling tests, including testing of shutters and setpoints .

The values ​​are recorded in the report submitted to the client. This technical file facilitates maintenance monitoring and analysis in the event of changing needs.

Result: immediate comfort and discreet aesthetics

The living room benefits from directional airflow that effectively covers the occupied area, without unpleasant drafts. The unit blends into the light-colored wall; with the shutter lowered, it ensures uniform diffusion across the entire length of the room. During the day and evening, the noise level remains muffled thanks to the ZU1's inverter modulation. In summer, the system acts as a wall-mounted air conditioner , dehumidifying and stabilizing the temperature. In winter, it provides responsive and economical additional heat .

HVAC Maintenance: A Simple Plan to Maintain Performance

We provide the owner with a maintenance schedule :

  • filters : rinse every 4 to 6 weeks during the active season;

  • annual AirGreen inspection : gentle washing of the exchanger, electrical check, verification of air flow and drain ;

  • pre-winter : free up space around the outdoor condenser, check anti-vibration pads and fixings ;

  • good practices : adapted instructions (moderate heating at night, gradual increase in the morning) and shutter oriented to sweep the occupied area.

Regular maintenance maintains seasonal performance , limits odors and extends equipment life .

Grants and documentation

Depending on the capacity and advertised performance of the installed configuration, the Sharp ZU1 may be eligible for grant programs promoting energy efficiency in Quebec. We assist our customers in Montreal, Laval, Longueuil, North Shore, and South Shore in preparing the file : model number, serial number, installation photos, detailed invoice, and proof of commissioning. This assistance reduces processing time and secures the receipt of financial assistance when the criteria are met.

Common Mistakes Avoided by AirGreen

  • Too low positioning of the head with air recirculation: we have favored an optimized height .

  • Unsealed drilling and thermal bridges: vapor barrier, mastication and capping finish.

  • Insufficient bending radius and absence of expansion loop: controlled bending and service loop .

  • Drain without slope or too long: short path, continuous slope, close fixing points.

  • Airflow incorrectly adjusted : fan calibration, check speeds and noise under load.

Every detail counts to achieve a reliable, quiet and durable system .

Why choose AirGreen for your installation in Villeray–Saint-Michel–Parc-Extension and Greater Montreal

Our teams are familiar with the types of plexes in the sector: shared walls, flat roofs, technical crossings, access constraints. We operate with a proven process : needs audit, equipment selection , meticulous HVAC installation , instrumented commissioning and monitoring . Our promise: tangible comfort , aesthetic integration , and a return on investment driven by energy efficiency.


AirGreen — specialists in the installation of wall-mounted heat pumps and wall-mounted air conditioners in Montreal, Laval, Longueuil, on the North Shore and the South Shore.

Leave a comment