Centralized or decentralized heating in a commercial building: a space-by-space plan

7 min to read it all

The gist

One central unit that heats the whole building, or one unit per space that follows its own hours: on a four-space building, this guide shows what each way of heating changes for schedules, ducts, meters, maintenance and the Construction Code.

Read the details

In detail

Guide · Commercial heating · Greater Montréal

One unit for the whole building, or one unit per space

A centralized system produces heat in one place and distributes it through ducts or pipes. A decentralized system puts a unit in each space. Move the clock: four spaces, four schedules, and the difference shows for itself.

Commercial building with several spacesConstruction Code, chapter I.1 (NECB 2020) since July 13, 2024Data checked November 17, 2026
How the heat is produced
Occupied space, heated (centralized, decentralized)Empty space still receiving heat from the central unitEmpty space, unit off or damper closed
One day, four spaces

When each space keeps its own hours, what gets heated?

Pick the use of each space. Dark cells are the occupied hours. With a central unit and no zone dampers, warm air goes everywhere as soon as one space is occupied: the hatched cells show it. With one unit per space, each one follows its own hours.

of central unit running per day, as soon as one space is occupied
of zone units running in total, each during its own space’s hours

Typical hours, to replace with yours. An empty space is never cut off from heat: it keeps a setback temperature to protect it from freezing. The count only includes the hours when a space receives the occupied temperature.

What each plan installs

The same building, two different worksites

Pick the situation that looks like your building. The two columns list what each way of heating needs on site.

Centralized

    Decentralized

      Your building

      Six questions to ask before choosing

      Neither way of heating suits every building. Here is what to look at, and which way each answer leans.

      Do the spaces keep the same hours?

      An office closes at 5 p.m., a store at 9 p.m., a warehouse starts at 6 a.m. The further apart the hours, the more zoning matters.

      Same hours: one central unit follows everyoneDifferent hours: each unit follows its own space

      Are there ducts or an accessible ceiling?

      A duct network needs room: dropped ceiling, shafts, basement. The refrigerant lines of a unit per space are small in diameter.

      Ducts in place: the network can be reusedNo ducts: thin lines are enough

      Who pays for the heat?

      A shared unit connects to one panel. A unit per space can connect to that space’s panel, so to its occupant’s meter.

      Owner: one shared meter, costs to allocateEach tenant: their unit, their meter

      Is fresh air planned for?

      A forced-air central unit can take fresh air and filtration in its ducts. A wall unit or cassette recirculates the air of the space.

      Central forced air: fresh air can use the ductsPer space: ventilation is planned separately

      What happens if a unit stops?

      When the central unit stops, the whole building waits for the repair, unless a second unit is planned. When a space’s unit stops, only that space is affected.

      Central: the whole building, a backup is plannedPer space: one space affected

      Will the building change?

      Moving walls, a split space, a new use: each way of heating adapts differently.

      Central: grilles and dampers are movedPer space: a unit is added or removed
      Side by side

      Centralized and decentralized, line by line

      No line is highlighted: these are two ways to organize heating, and each building weighs these lines its own way.

      LineCentralizedone unit, one networkDecentralizedone unit per space
      The heat
      Heat productionOne unit, or a small group of units, in a mechanical room or on the roofOne unit in each space: wall, ceiling cassette, console or rooftop unit
      DistributionAir ducts or hot water pipes to each spaceNo distribution network; refrigerant lines link each indoor unit to its outdoor unitexcept rooftop units and baseboards
      Temperature controlOne thermostat for the unit, or one per zone with motorized dampersOne thermostat or remote per unit
      Different hours from one space to the nextThe unit runs as soon as one space is occupied; dampers close empty zones if there are anyEach unit follows its own space’s hours
      Air and comfort
      Fresh air and filtrationPossible in the ducts of a forced-air systemThe unit recirculates the space’s air; ventilation is a separate system
      CoolingPossible with a coil and an outdoor unit on the same air networkA heat pump in each space heats and cools
      Noise in the spacesThe unit is away from the spaces; mostly the air at the grilles is heardThe unit’s fan is in the space
      Operation
      Meter and billingOne panel, one shared meter; costs are allocated by agreementEach unit can be wired to the panel of the space it heats
      MaintenanceOne main unit, plus ducts, dampers and filtersAs many indoor and outdoor units as spaces, each with its filter
      A unit stopsThe whole building is affected unless a backup unit is plannedOnly that unit’s space is affected
      Technical spaceMechanical room or roof, plus room for ductsA wall or ceiling per space, and an outdoor spot per unit
      Change of useDucts, grilles and dampers are modifiedUnits are added, moved or removed
      New construction or additionConstruction Code chapter I.1 (NECB 2020 as amended)Construction Code chapter I.1 (NECB 2020 as amended)

      Both columns describe typical systems. The same building often combines both: a central unit for open areas and space units for rooms with their own hours.

      Questions

      What building managers ask us

      Which one costs less to run?

      It depends on the energy used, the efficiency of the units, the hours and the insulation, not only on the centralized or decentralized layout. The price of a kWh of heat by energy and appliance is detailed in our gas or electricity guide for businesses. We do not give an amount without seeing the building.

      Can a central system have zones?

      Yes. Motorized dampers in the ducts and one thermostat per zone let empty zones close. How many zones can close at once is limited by the unit’s minimum airflow, given by its manufacturer.

      Does a unit per space supply fresh air?

      No. A wall unit, cassette or console recirculates the air in the space. Fresh air comes from a separate ventilation system, such as an air exchanger.

      Can both be combined in one building?

      Yes, it is common: a central system for large areas with the same hours, and space units for rooms with their own hours or their own temperature needs.

      Does the Construction Code require one or the other?

      Chapter I.1 of the Québec Construction Code sets energy efficiency requirements for new buildings and additions; since July 13, 2024, it uses the 2020 edition of the National Energy Code of Canada for Buildings with Québec’s amendments. The centralized or decentralized choice is made within that framework, with the project’s professionals.

      Who does the work?

      Work on gas or oil appliances, boilers and hydronic systems is entrusted to a licensed partner; AirGreen (RBQ licence 5645-9605-01) handles heat pumps, ventilation, refrigeration and electrical work.

      Is there financial assistance for businesses?

      Hydro-Québec and Énergir each publish programs for their business customers. Their conditions and amounts change: check them on both utilities’ websites before deciding. We do not promise any amount.

      We look at your spaces before we talk about units.

      Hours, ducts, panels, ceilings: the estimate visit is free and the quote arrives within 24 hours.

      Sources

      Documents consulted

      You made it to the end.Share it with someone it could help.

      Related questions

      Leave a comment