Updated September 24, 2026Rules from Hydro-Québec, NRCan and the manufacturers
2026 guide · Wall-mounted heat pump · Montréal

Basic rules for ductless mini splits: the 10 that matter in Montréal

Well chosen, well installed and well set, a mini split heats with up to 3 times less electricity than your baseboards (Hydro-Québec). Set up wrong, it’s your baseboards that do the heating, at full price. Here are the 10 rules, a 2-minute test and the tools to apply them at home.

By AirGreen Climatisation & ChauffagePublished April 11, 2023Updated September 24, 2026Reading: 20 min · test: 2 min

This month · September
15.5 °C

average temperature in Montréal (Environment Canada, 1981-2010)

  • Clean the filters before the heating season.
  • Set the baseboards 2 to 3 °C below the heat pump again.
  • Forget Auto mode.
My calendar
NRCan · Hydro-Québec
2 to 3 °C

lower for the baseboards than for the heat pump. The heat pump has to heat first.

Hydro-Québec
1 month

between filter cleanings when it runs hard. A dirty filter costs it 10 to 30% of its efficiency.

LogisVert · cold climate
$120/ 1,000 BTU/h

of heating capacity at -8 °C, if the outdoor unit is 12,000 BTU/h or more. Apply within 9 months.

15 to 20 yearsthe lifespan of an air-source heat pump, according to NRCan
2 °Cthe maximum setback advised at night or when you are away
201 hper year below -15 °C in Montréal, from 2015 to 2025 (ECCC)
+25%more electricity, at worst, for a poorly maintained unit
01 · Understand

What is a ductless mini split?

A ductless mini split, or wall-mounted heat pump, connects an outdoor unit to one or more indoor units through refrigerant lines. With no air ducts, each unit heats or cools the room it is in directly. One head: that’s a single-zone system. Several heads on the same outdoor unit: a multi-zone system (NRCan).

Single-zone or multi-zone: one outdoor unit, one or more heads Bedroom 1Bedroom 2 Living roomKitchen Outdoor unit Refrigerant lines 1 head: heats the room it is in 3 heads, 1 single outdoor unit
Single-zone or multi-zone: one outdoor unit, one or more heads Bedroom 1Bedroom 2 Living roomKitchen Outdoor Refrigerant lines

Multi-zone: three heads on the same outdoor unit. Every room with its own head is heated, with its own remote.

Illustration of three people approving a ductless wall-mounted heat pump
One outdoor unit, one or more heads: the diagram shows how it all connects.
EfficientUp to 3 times less electricity than baseboards for the same heat (Hydro-Québec).
No ductsNo air ducts to install: a hole of about 7 cm, a refrigerant line and a drain.
VersatileIt heats in winter, cools and dehumidifies in summer, room by room.

Single-zone, multi-zone or central

Three ways to heat with a heat pump. The ductless mini split is the first two.

Ductless single-zoneDuctless multi-zoneDucted central
Indoor units1 head2 heads or more1 air handler
Outdoor unit11 for all the heads1
Air ductsNoneNoneYes, throughout the house
What it heatsThe room the head is inEvery room that has its own headThe whole house, through the vents
Controls1 remote1 per head1 thermostat
LogisVertYes, outdoor unit of 12,000 BTU/h and upYes, same conditionYes, same condition

NRCan definitions (“single-zone”, “multi-split”); eligibility: Hydro-Québec’s LogisVert guide v1.10. Wall-mounted or central: the full comparison.

Where the indoor head goes

Ductless units go on the wall, in the ceiling or near the floor.

Wall-mounted, high on the wall

The most common. At least 2.3 to 2.5 m from the floor in the manuals we checked, and 15 cm clear above for the Gree Sapphire.

Cassette, in the ceiling

Recessed; air comes out in one or more directions (1-way or 8-way models at Gree).

Console, near the floor

Mounted low on the wall or on the floor (NRCan).

Wherever you put it: away from strong heat sources, nothing in front of the air intake or outlet, and not right above an electrical appliance (Gree installation manual). Direct sun and strong wind are what you protect the outdoor unit from (same manual).

02 · The house, point by point

Nine places where it all happens, from the indoor head to the stand in the snow.

Touch a point. Switch from winter to summer: the settings change with the season.

Property line
Point 1 of 9 · Winter

The indoor head

Down

the louvre direction in heating, fan on high or automatic (NRCan)

Let it breathe: respect the clearances in the manual, for example 6 in. (15 cm) above for the Gree Sapphire, and don’t hide it behind furniture. It heats the room it is in: install it where you live.

Source: NRCan (2025-12-24) · Gree manual

Where to install the head

1 of 9 points seen.

03 · The test

Does your mini split follow the basic rules? The 10-question test.

Answer honestly. Every “no” points to the fix, from the most cost-effective to the least urgent.

1
The size was chosen after an assessment of the home.Rule 1 · Choose
2
Your model is ENERGY STAR cold climate.Rule 2 · Choose
3
The indoor head is in the room you use the most.Rule 3 · Choose
4
Nothing blocks the air in front of or under the head: furniture, curtain, shelf.Rule 4 · Install
5
The outdoor unit is raised and clear of snow and leaves.Rule 5 · Install
6
In winter, the remote is on Heat, not Auto.Rule 6 · Use
7
Your baseboards are set 2 to 3 °C lower than the heat pump.Rule 7 · Use
8
You keep the same setpoint, without turning it off at night.Rule 8 · Use
9
The indoor filters were cleaned in the last 3 months.Rule 9 · Maintain
10
A technician serviced it within the last year.Rule 10 · Maintain
Your result
0/ 10

0 of 10 questions answered.

Start with question 1Yes, no or I don’t know: your result builds as you go.
Read the rules
04 · The 10 rules

The 10 basic rules for a ductless mini split: choose, install, use, maintain.

Touch a rule: the why, the number, what to do and what to avoid, with the source.

UseRule 07

Baseboards 2 to 3 °C lower

2 to 3 °C

apart. Hydro-Québec’s example: heat pump 20 °C, baseboards 18 °C.

NRCan recommends setting backup heating 2 to 3 °C below the heat pump’s setpoint: the heat pump then supplies most of the heat. Baseboards are still useful: in deep cold and during defrost, they take over.

Do

Lower the thermostats in rooms heated by the heat pump.

Keep the baseboards on: they are your backup.

Avoid

Shutting off the baseboards for the winter.

Source: NRCan (2025-12-24) · Hydro-Québec, LogisVert leaflet (rev. 07/2026)

Keep the heat pump on?
05 · Choose

What size mini split for your room or your home?

In Québec, heating is what decides. Enter the floor area: we round up to the nearest catalogue size, with a real model as an example.

1Floor area to heat

Both benchmarks come from two Hydro-Québec pages: 12,000 BTU/h for 750 sq. ft (“Choosing the right capacity”) and 15,000 BTU/h for 750 sq. ft (“Seven points to consider”). Even Hydro-Québec doesn’t give a single number: the real answer depends on the ceilings, the windows and the insulation.

Starting point
12,000BTU/h

to 15,000 BTU/h depending on the benchmark used, for 750 sq. ft. An on-site assessment settles it.

Benchmark A · 12,000 BTU/h per 750 sq. ft12,000 BTU/h
Benchmark B · 15,000 BTU/h per 750 sq. ft15,000 BTU/h
Example · Sharp CHU 12,00018,900 BTU/h at -8 °C · AHRI 217512736$2,268

Indicative LogisVert amount: capacity at -8 °C ÷ 1,000 × $120, capped at the cost. Only Hydro-Québec confirms the grant.

What an on-site assessment looks at

Floor area, ceiling height, insulation and climate, plus sun exposure and the number of occupants.

Floor areaThe starting point of the calculation.
CeilingsA high ceiling means more air to heat.
InsulationWalls, roof, doors and windows.
ClimateMontréal’s design temperature: -23 °C (NBC 2020).
SunVery sunny room: +10% (ENERGY STAR).
Occupants+600 BTU/h per person beyond two (ENERGY STAR).

Too big or too small: what it changes

Too bigToo small
What happensIt keeps starting and stopping (short cycles).The baseboards take over more often.
In summerIt cools fast but dehumidifies poorly: humid, clammy air.It can struggle during heat waves.
ComfortDiscomfort and wear on the unit.Rooms that don’t warm up in deep cold.
The billThe savings you expected may not happen.Electric backup heat costs more than the heat pump.

NRCan (2025-12-24); Hydro-Québec, Choosing the right capacity; ENERGY STAR, room air conditioners.

Hydro-Québec’s benchmarks by type of home

Type of homeTypical capacityWhat Hydro-Québec says
Condo12,000 to 24,000 BTU/hA ductless wall-mounted heat pump is appropriate.
Bungalow24,000 to 48,000 BTU/hDepending on floor area and insulation.
Two-storey houseUp to 65,000 BTU/hWithout forced air: two single-zone heat pumps, one per floor.

Hydro-Québec, “Heat pump: how to determine the right capacity”, accessed September 24, 2026.

Our cold-climate wall units, side by side

Sort them. Each row leads to the model’s page.

Model (AirGreen)AHRIHeat at -8 °CLogisVert (indicative)Heats down toIndoor soundOutdoor sound
Sharp CHU 18,00021750892522,600 BTU/h$2,712-30 °C25 / 49 dB52 dB
Sharp CHU 12,00021751273618,900 BTU/h$2,268-30 °C22 / 44 dB50 dB
Fujitsu ORION XLTH 18,00021564792113,600 BTU/h$1,632-26 °C30 / 46 dB50 dB
Samsung WindFree MaxHeat 12,00021539929110,600 BTU/h$1,272-30 °C22 / 39 dB46 dB
Fujitsu ORION XLTH 12,00021488880210,000 BTU/h$1,200-26 °C23 / 44 dB47 dB
Fujitsu ORION XLTH+ 12,0002160182569,600 BTU/h$1,152-30 °C23 / 45 dB49 dB

AirGreen spec sheets read on September 24, 2026. Indicative LogisVert = capacity at -8 °C ÷ 1,000 × $120 (ENERGY STAR cold climate), capped at the cost; only Hydro-Québec confirms the grant. Indoor sound: minimum / maximum, in dB. A 9,000 BTU/h wall unit on its own is not eligible for LogisVert.

06 · Install

Where to install the outdoor unit: snow, air and neighbours.

It draws in air, drains defrost water and can be heard outside. Three reasons to choose its spot carefully.

Outdoor unit: above the snow, with air behind and in front 100 mm clear 600 mm clear in front Higher than drifting snow
Outdoor unit: above the snow, with air behind and in front 100 mm 600 mm in front Above snow
  • On a stand higher than drifting snow.Fujitsu installation manual (part 9374747160)
  • Securely anchored if exposed to wind, out of direct sun if possible.Fujitsu and Gree manuals
  • Below 0 °C, no drain hose or drain cap supplied: the water would freeze in them.Fujitsu manual
  • Away from neighbours’ windows and bedrooms; a corner adds up to 6 dB.Manuals; AHRI 275
  • Clear of leaves, grass clippings and branches, all year.Hydro-Québec

Example clearances, from a Fujitsu manual: each model has its own, in its installation manual.

Will your neighbour hear it? Test the location

Five choices, one number: the estimated sound level at the property line.

1Your model
2Distance to the property line
3Around the unit
4A screen between the unit and the neighbour
5Your city’s limit
At the property line
43.5 dB

estimated at 3 m, versus 50 dB allowed. A quiet room: 40 dB(A); a conversation at 1 m: 55 dB(A) (CCOHS).

limit 50 dB
30 dB40 dB, quiet room60 dB
Model spec sheet, at 1 m50 dB
Distance, 3 m-9.5 dB
Walls around+3 dB
Screen0 dB
City limit50 dB
Under the limit, with 6.5 dB to spareOn paper, the location passes. Wind and real surfaces can add a few decibels.

Indicative estimate based on the AHRI 275 standard, from the 1 m level listed on our spec sheets. Wind, background noise and real surfaces change the result.

Your city’s rules

WhereNoise allowedPermitGood to know
Ahuntsic-Cartierville50 dB at the property line— See the page
Lachine50 dB at the property line—The city may require an acoustic study or a screen. See the page
Mercier–Hochelaga-Maisonneuve55 dB from 7 a.m. to 10 p.m., 52 dB at night— See the page
Montréal-Nord50 dB at the property lineYes See the page
Saint-Léonard50 dB at the property lineYes See the page
Rosemont–La Petite-PatrieStandards in the commitment formYesStudy and screen for large equipment. See the page
Verdun—YesScreen possible on rooftops. See the page
Outremont, Ville-Marie, Villeray–Saint-Michel–Parc-Extension—Yes See the page
Longueuil (Saint-Hubert, Greenfield Park, Vieux-Longueuil)53 dB(A)No1 m from a lot line, 2 m high at most, hidden from the street if 2 m or less. See the page
Laval—No, if sections 265 and 266 of the planning code are metFines from $400 to $1,000. See the page

Ville de Montréal, summary by borough (updated August 3, 2026); Ville de Longueuil (Noise page and Heat pump sheet, July 2025); Ville de Laval (April 4, 2025). “—”: nothing specified in the official summary. Always check the by-law in force. All cities and boroughs.

07 · Use

How to set a mini split, winter and summer.

Touch a season. Every setting comes from Hydro-Québec or NRCan.

Mode
Heat
20 °C

Example from Hydro-Québec’s LogisVert leaflet

FanHigh or Auto
LouvresDown
Baseboards, 2 to 3 °C lower18 °C

Let it run continuously, at the same setpoint.Hydro-Québec

At night, a 2 °C setback at most, or a smart thermostat that restarts early.NRCan

Forget Auto mode.Hydro-Québec

Keep the outdoor unit clear of snow, ice and leaves.Hydro-Québec

Steam on the outdoor unit? That’s the defrost cycle.NRCan

A winter peak day, hour by hour

Rate Flex D: from December 1 to March 31, up to 30 events and 120 hours per winter, announced the day before.

0h2h4h6h8h10h12h14h16h18h20h22h
Preheating, 22.5 °CDuring the peak, 20 °CUsual setpoint, 21 °CHours at 46.463¢ per kWh

Hydro-Québec’s example for a 21 °C setpoint. Hours on the chart: midnight to 11 p.m.

Both · the same day
8 h

at the peak price that day, 46.463¢ per kWh. Preheat 2 h before, lower to 20 °C during, go back to 21 °C.

Off-peak, first 40 kWh per day4.886¢
Off-peak, above that9.103¢
During a peak event46.463¢
Average savings, winter 2025-2026$90 to $150
First-winter protectionIf the bill is higher than it would have been on the base rate, Hydro-Québec refunds the difference.
08 · Deep cold

A mini split in deep cold in Montréal: what really happens.

Choose your model’s minimum temperature. Both charts update.

1Your model’s minimum temperature

The coldest night of the last 10 winters

On February 4, 2023, it hit -29.3 °C. Drag the slider, hour by hour.

-10 °C-15 °C-20 °C-25 °C-30 °CFeb. 3, 0:00Feb. 3, 12:00Feb. 4, 0:00Feb. 4, 12:00Feb. 5, 0:00Feb. 5, 12:00
Hourly temperatureModel limit: -26 °CShaded zone: below the limit, the baseboards heat alone
-10 °C-15 °C-20 °C-25 °C-30 °CFeb. 3, 0:00Feb. 4, 0:00Feb. 5, 0:00
Hourly temperatureModel limit: -26 °CShaded zone: below the limit, the baseboards heat alone

Montréal airport, hourly readings from Environment and Climate Change Canada. The 4 a.m. reading on February 4 is missing: interpolated.

February 4, 2023, 5:00
-29.3 °C
Below its limit: baseboards only

Below the minimum temperature listed by the manufacturer, the baseboards heat alone.

Hours below -26 °C during these 61 hours20 h
Lowest reading-29.3 °C
Hours per year below -20 °C, 2015 to 202550 h
The rule that followsKeep your baseboards on, set 2 to 3 °C below the heat pump. They are your safety net for those few hours each winter.

Ten winters of hourly readings

How many hours per year below your model’s limit, and what share of heating needs stays above it.

-30 °C-20 °C-10 °C0 °C10 °C18 °C
Below the limit: the baseboards heat aloneThe heat pump can heat

Hours per year at each temperature, Montréal airport, July 2015 to June 2025. AirGreen calculation from Environment Canada hourly readings, degree-hours below 18 °C. Indicative.

Heating needs covered
99.8%

of winter heating needs come above -26 °C, the limit you chose.

Hours per year below -26 °C4.0 h
In full daysless than half a day
Coldest night of the 10 winters-29.3 °C, Feb. 4, 2023
Almost the whole winter, on paperEven above its limit, a heat pump loses capacity in the cold. That is why you keep the baseboards, set 2 to 3 °C lower.
09 · Maintain

Mini split maintenance: filters every month, a technician every year.

Neglecting maintenance means lower efficiency, a higher bill and, eventually, breakdowns. Here is what you do, and what the technician does.

Clean the filters in 4 steps

Every month when it runs hard, at least at the start of each season (Hydro-Québec); every 3 months at most (NRCan).

1

Open the front panel

Lift the front panel of the indoor head, with the unit off.

2

Remove the filters

They slide down, no tools needed.

3

Rinse with water

Room-temperature water, no detergent (Hydro-Québec).

4

Dry in the shade

Completely, out of the sun, before putting them back.

You, in two minutes

0 / 5

The technician, once a year

0 / 4

NRCan recommends having the yearly service done by a qualified contractor.

$What the heat pump costs you in electricity

Hydro-Québec estimates a poorly maintained unit can use up to 25% more electricity, and a dirty filter costs it 10 to 30% of its efficiency.

A neglected unit, at worst
+$125

per year, at worst, on $500 of electricity: up to 25% more for a poorly maintained unit (Hydro-Québec).

Over 15 years, at today’s rate+$1,875
Maintenance, pricing or a free on-site estimateContact us: our technicians service wall-mounted heat pumps across Greater Montréal.
Contact us
10 · Normal or not

That noise, that steam, that water: normal or not?

Eight normal behaviours and four signs worth a call, from the manufacturers’ manuals and our service team.

Verdict
Normal

Steam on the outdoor unit in winter

That’s the defrost cycle: the outdoor fan stops, the frost melts, then heating resumes.

Source: NRCan (2025-12-24)

Before you call

  1. Clear the outdoor unit: snow, ice, leaves.
  2. Check that the filters are clean.
  3. Turn the head off, switch off the breaker for 15 to 20 minutes, then turn it back on.
11 · My calendar

Your maintenance calendar, from the installation date.

LogisVert, filters, peaks, service, legal warranty: every date is calculated from today.

2Filter cleaning
3On Rate Flex D?
4Purchase contract signed
LogisVert · apply by June 24, 2027 at the latest
273 days
Time left

to send your LogisVert application to Hydro-Québec, with your invoice.

  1. September 24, 2026Today

    Installation

    Keep the itemized invoice and the model numbers of both units.

  2. October 24, 2026In 30 days

    Next filter cleaning

    Then every month in peak season (Hydro-Québec). Water, no detergent, dried out of the sun.

  3. December 1, 2026In 68 days

    Flex D peak events begin

    Preheat by 1 or 2 degrees before each event, lower during, then go back.

  4. June 24, 2027In 273 days

    Last day to apply for LogisVert

    $120 per 1,000 BTU/h of heating at -8 °C for an ENERGY STAR cold-climate model, $50 for a regular ENERGY STAR unit. Outdoor unit of 12,000 BTU/h and up.

  5. September 24, 2027In 365 days

    Yearly service by a professional

    NRCan recommends it every year. A poorly maintained unit can use up to 25% more (Hydro-Québec).

  6. September 24, 2032In 2192 days

    End of the legal warranty of good working order

    New Québec law: 6 years for a heat pump, from delivery, for contracts signed on or after October 5, 2026. Normal maintenance remains your responsibility.

  7. 2041 to 2046NRCan

    Typical end of service life

    15 to 20 years for an air-source heat pump, according to NRCan, with yearly servicing.

Dates calculated from today. LogisVert: no later than 9 months after installation (guide v1.10). Only Hydro-Québec confirms the grant.

The year, month by month

The current month is already selected. 1981-2010 normals for Montréal airport (Environment Canada).

Heating degree-daysCooling degree-days
September · recommended setting
20 °C

Heat · from the first cold nights

Average temperature15.5 °C
Heating degree-days94
Cooling degree-days21
To do in September
  • Clean the filters before the heating season.
  • Set the baseboards 2 to 3 °C below the heat pump again.
  • Forget Auto mode.

The number of the month. 15.5 °C on average: 94 heating degree-days, 21 cooling.

12 · The traps

Six common beliefs that cost money, corrected by official sources.

At night
“Turning it off at night saves money.”In the morning, the baseboards do the catching up. Set it back 2 °C at most (NRCan).
Auto
“Auto mode knows best.”Hydro-Québec says to forget it, winter and summer.
Steam
“Steam is coming out of the unit: it’s broken.”That’s the defrost cycle. The outdoor fan stops, the frost melts, then heating resumes.
Bigger
“A bigger unit will heat better.”Oversized, it runs in short cycles and dehumidifies poorly in summer.
No hole
“Ductless means no work.”You need a hole of about 7 cm in the wall, a drain and a power supply.
Ottawa
“The federal government pays too.”In Québec, the Greener Homes Grant closed on September 30, 2025, and the oil-to-heat-pump program (OHPA) has not taken applications since July 31, 2026. LogisVert remains.
13 · In short

Following these rules gets the most out of your wall-mounted heat pump, and keeps it running for years.

Sizing, installation and maintenance make the difference. Work with experienced HVAC professionals to choose the unit and install it.

Choose

The right size, ENERGY STAR cold climate, one head per living space.

Install

A head that can breathe, an outdoor unit above the snow, away from the neighbours.

Use

Heat mode, baseboards 2 to 3 °C lower, a steady setpoint. In summer, 22 to 25 °C.

Maintain

Clean filters every month in season, a technician once a year.

Go further

14 · Frequently asked questions

The 14 questions we get asked most about ductless mini splits.

Hydro-Québec gives two benchmarks: about 12,000 BTU/h for 750 sq. ft in its capacity guide, and 15,000 BTU/h for 750 sq. ft in its seven points to consider. In Québec, heating is what decides. An on-site assessment takes the ceilings, windows and insulation into account.

AirGreen · Free estimate

A mini split of the right size, in the right place, set up right from day one.

An advisor assesses your home on site, suggests ENERGY STAR cold-climate models with their indicative LogisVert amount, and sends you a detailed quote within 24 h.

RBQ licence 5645-9605-01Subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
The AHRI number on our spec sheetsEvery certified model shows its rating and its indicative LogisVert amount.
Free on-site estimateA detailed quote is sent to you within 24 h.

Hydro-Québec does not solicit by phone or door to door for LogisVert. Only Hydro-Québec approves and pays the grant.

Sources. Sources checked on September 24, 2026. Natural Resources Canada: “Heating and cooling with a heat pump” (modified December 24, 2025). Hydro-Québec: LogisVert leaflet “Tips for using a heat pump” (2025G386F, rev. 07/2026); guide “Using and maintaining a heat pump” (version 1, March 16, 2026); tips “Seven tips”, “Using your heat pump in winter”, “Six summer tips”, “Seven points to consider” and “Choosing the right capacity”; Rate Flex D and rate schedule as of April 1, 2026; LogisVert residential participation guide v1.10 (September 15, 2026). EPA ENERGY STAR: Heat Pump specification v6.2. Installation manuals from Fujitsu General (outdoor unit, part 9374747160), Gree and Mitsubishi. AHRI 275 (application of sound ratings). Ville de Montréal (update of August 3, 2026), Ville de Longueuil (July 2025), Ville de Laval (April 4, 2025). CCOHS. Health Canada. Gree VIREO+ ULTRA installation and owner’s manual (031519). Environment and Climate Change Canada: 1981-2010 normals and hourly readings for MONTREAL INTL A, July 2015 to June 2025 (AirGreen calculation, indicative). AirGreen spec sheets and AHRI numbers read on September 24, 2026. Amounts shown are estimates; only the responsible organizations confirm the assistance granted.

Leave a comment