Wall-mounted, high on the wall
The most common. At least 2.3 to 2.5 m from the floor in the manuals we checked, and 15 cm clear above for the Gree Sapphire.
Well chosen, well installed and well set, a mini split heats with up to 3 times less electricity than your baseboards (Hydro-Québec). Set up wrong, it’s your baseboards that do the heating, at full price. Here are the 10 rules, a 2-minute test and the tools to apply them at home.
By AirGreen Climatisation & ChauffagePublished April 11, 2023Updated September 24, 2026Reading: 20 min · test: 2 min
average temperature in Montréal (Environment Canada, 1981-2010)
lower for the baseboards than for the heat pump. The heat pump has to heat first.
between filter cleanings when it runs hard. A dirty filter costs it 10 to 30% of its efficiency.
of heating capacity at -8 °C, if the outdoor unit is 12,000 BTU/h or more. Apply within 9 months.
A ductless mini split, or wall-mounted heat pump, connects an outdoor unit to one or more indoor units through refrigerant lines. With no air ducts, each unit heats or cools the room it is in directly. One head: that’s a single-zone system. Several heads on the same outdoor unit: a multi-zone system (NRCan).
Multi-zone: three heads on the same outdoor unit. Every room with its own head is heated, with its own remote.

Three ways to heat with a heat pump. The ductless mini split is the first two.
| Ductless single-zone | Ductless multi-zone | Ducted central | |
|---|---|---|---|
| Indoor units | 1 head | 2 heads or more | 1 air handler |
| Outdoor unit | 1 | 1 for all the heads | 1 |
| Air ducts | None | None | Yes, throughout the house |
| What it heats | The room the head is in | Every room that has its own head | The whole house, through the vents |
| Controls | 1 remote | 1 per head | 1 thermostat |
| LogisVert | Yes, outdoor unit of 12,000 BTU/h and up | Yes, same condition | Yes, same condition |
NRCan definitions (“single-zone”, “multi-split”); eligibility: Hydro-Québec’s LogisVert guide v1.10. Wall-mounted or central: the full comparison.
Ductless units go on the wall, in the ceiling or near the floor.
The most common. At least 2.3 to 2.5 m from the floor in the manuals we checked, and 15 cm clear above for the Gree Sapphire.
Recessed; air comes out in one or more directions (1-way or 8-way models at Gree).
Mounted low on the wall or on the floor (NRCan).
Wherever you put it: away from strong heat sources, nothing in front of the air intake or outlet, and not right above an electrical appliance (Gree installation manual). Direct sun and strong wind are what you protect the outdoor unit from (same manual).
Touch a point. Switch from winter to summer: the settings change with the season.
the louvre direction in heating, fan on high or automatic (NRCan)
Let it breathe: respect the clearances in the manual, for example 6 in. (15 cm) above for the Gree Sapphire, and don’t hide it behind furniture. It heats the room it is in: install it where you live.
Source: NRCan (2025-12-24) · Gree manual
Where to install the head1 of 9 points seen.
Answer honestly. Every “no” points to the fix, from the most cost-effective to the least urgent.
0 of 10 questions answered.
Touch a rule: the why, the number, what to do and what to avoid, with the source.
= 12,000 to 15,000 BTU/h according to Hydro-Québec’s two guides
An oversized heat pump runs in short cycles: discomfort, wear and lost savings (NRCan), and in summer, air that stays humid (Hydro-Québec). An undersized one lets the baseboards take over more often. In Québec, you size it to cover heating without oversizing it for cooling.
Have the home assessed: floor area, ceilings, windows, insulation.
Ask how the size was chosen.
Going “a bit bigger, just in case”.
Source: NRCan (2025-12-24) · Hydro-Québec, Choosing the right capacity · Seven points to consider
Calculate the right sizeminimum COP at -15 °C to be “cold climate” under ENERGY STAR
For ENERGY STAR, “cold climate” means a COP of at least 1.75 at -15 °C, with at least 70% of its 8 °C capacity still available at -15 °C. LogisVert pays $120 per 1,000 BTU/h at -8 °C for these models, versus $50 for a regular ENERGY STAR unit. Since November 26, 2025, a non-certified unit is not eligible.
Check the AHRI number on the model’s spec sheet.
Compare the capacity at -8 °C, not just the SEER.
Choosing on SEER alone: it measures summer.
Source: EPA ENERGY STAR, Heat Pump v6.2 · Hydro-Québec, LogisVert guide v1.10 (Sept. 15, 2026)
All about LogisVert= 1 single-zone heat pump, for a two-storey home without ducts (Hydro-Québec)
Ductless indoor units heat or cool the air of the room they are installed in (NRCan). For a two-storey home without forced air, Hydro-Québec suggests two single-zone heat pumps, one per floor. Several closed rooms: a multi-zone system connects several heads to a single outdoor unit.
Install the head in the busiest room, where air can flow to the others.
In summer, keep bedroom doors open (Hydro-Québec).
Counting on the living-room head to heat closed bedrooms.
Source: NRCan (2025-12-24) · Hydro-Québec, Choosing the right capacity
Wall-mounted or central?the hole in the wall for the refrigerant line and the drain, per the manuals
Every manufacturer sets clearances around the head, for example 6 in. (15 cm) above for the Gree Sapphire. NRCan notes that poor airflow shortens equipment life and lowers efficiency. And “ductless” does not mean no work: you need a hole of about 7 cm to the outside, a drain and a power supply.
Respect the clearances in the installation manual.
Keep furniture, curtains and shelves away from the air intake and outlet.
Recessing the head in a niche or hiding it behind furniture.
Source: Gree, Fujitsu and Mitsubishi installation manuals · NRCan (2025-12-24)
Where to install the headmaximum at the property line in several Montréal boroughs
Manufacturers call for a raised stand, higher than drifting snow (Fujitsu manual). Hydro-Québec says to keep it clear of snow, ice and leaves. For neighbours, each city has its rules: 50 dB at the property line in Ahuntsic-Cartierville, Lachine, Montréal-Nord and Saint-Léonard; 53 dB(A) and 1 m from a lot line in Longueuil.
Check your city’s by-law before installing.
Clear it after every storm.
Tucking it into a corner: two nearby walls add up to 6 dB (AHRI 275).
Source: Fujitsu manual (part 9374747160) · Hydro-Québec · montreal.ca (Aug. 3, 2026) · Longueuil (July 2025) · AHRI 275
Permits and by-lawsthe mode to keep all winter, with the fan on high or automatic
Hydro-Québec recommends Heat mode in winter, Cool in summer, and forgetting Auto mode. NRCan adds: in heating, fan on high or automatic and louvres pointing down; in cooling, fan on low to remove more humidity and air aimed at the occupants.
Winter: Heat, fan on high or auto, louvres down.
Summer: Cool, fan on low.
Leaving the remote on Auto all year.
Source: Hydro-Québec, Seven tips · LogisVert leaflet 2025G386F (rev. 07/2026) · NRCan
Settings by seasonapart. Hydro-Québec’s example: heat pump 20 °C, baseboards 18 °C.
NRCan recommends setting backup heating 2 to 3 °C below the heat pump’s setpoint: the heat pump then supplies most of the heat. Baseboards are still useful: in deep cold and during defrost, they take over.
Lower the thermostats in rooms heated by the heat pump.
Keep the baseboards on: they are your backup.
Shutting off the baseboards for the winter.
Source: NRCan (2025-12-24) · Hydro-Québec, LogisVert leaflet (rev. 07/2026)
Keep the heat pump on?setback, at most, at night or when you are away (NRCan)
Heat pumps respond more slowly than a furnace. NRCan advises a setback of no more than 2 °C, or a smart thermostat that restarts early. Hydro-Québec: let it run continuously; repeated adjustments use more energy and shorten its life.
Pick a setpoint and keep it.
Before a Flex D peak event, preheat by 1 or 2 degrees (Hydro-Québec).
Turning it off when you leave for work.
Source: NRCan (2025-12-24) · Hydro-Québec, Seven tips · Eight mistakes
Keep the heat pump on?of efficiency lost with a dirty filter (Hydro-Québec)
Hydro-Québec recommends cleaning the filters every month when the unit runs a lot, and at least at the start of each season; NRCan sets the maximum at 3 months. Rinse them with room-temperature water, no detergent, and let them dry completely out of the sun.
Every month in deep winter and during heat waves.
Put them back fully dry.
Washing them with detergent or putting them back wet.
Source: Hydro-Québec, Using and maintaining a heat pump (v1, Mar. 16, 2026) · Using your heat pump in winter · NRCan
Cleaning servicemore electricity, at worst, for a poorly maintained unit (Hydro-Québec)
NRCan recommends having a qualified contractor service the unit every year. Hydro-Québec estimates a poorly maintained unit can use up to 25% more electricity. Well maintained, an air-source heat pump lasts 15 to 20 years (NRCan).
Book the service visit once a year.
Keep your service invoices.
Waiting for a breakdown to call.
Source: NRCan (2025-12-24) · Hydro-Québec, Seven tips
Cleaning and maintenanceIn Québec, heating is what decides. Enter the floor area: we round up to the nearest catalogue size, with a real model as an example.
Both benchmarks come from two Hydro-Québec pages: 12,000 BTU/h for 750 sq. ft (“Choosing the right capacity”) and 15,000 BTU/h for 750 sq. ft (“Seven points to consider”). Even Hydro-Québec doesn’t give a single number: the real answer depends on the ceilings, the windows and the insulation.
to 15,000 BTU/h depending on the benchmark used, for 750 sq. ft. An on-site assessment settles it.
Example · Sharp CHU 12,00018,900 BTU/h at -8 °C · AHRI 217512736$2,268Indicative LogisVert amount: capacity at -8 °C ÷ 1,000 × $120, capped at the cost. Only Hydro-Québec confirms the grant.
Floor area, ceiling height, insulation and climate, plus sun exposure and the number of occupants.
| Too big | Too small | |
|---|---|---|
| What happens | It keeps starting and stopping (short cycles). | The baseboards take over more often. |
| In summer | It cools fast but dehumidifies poorly: humid, clammy air. | It can struggle during heat waves. |
| Comfort | Discomfort and wear on the unit. | Rooms that don’t warm up in deep cold. |
| The bill | The savings you expected may not happen. | Electric backup heat costs more than the heat pump. |
NRCan (2025-12-24); Hydro-Québec, Choosing the right capacity; ENERGY STAR, room air conditioners.
| Type of home | Typical capacity | What Hydro-Québec says |
|---|---|---|
| Condo | 12,000 to 24,000 BTU/h | A ductless wall-mounted heat pump is appropriate. |
| Bungalow | 24,000 to 48,000 BTU/h | Depending on floor area and insulation. |
| Two-storey house | Up to 65,000 BTU/h | Without forced air: two single-zone heat pumps, one per floor. |
Hydro-Québec, “Heat pump: how to determine the right capacity”, accessed September 24, 2026.
Sort them. Each row leads to the model’s page.
AirGreen spec sheets read on September 24, 2026. Indicative LogisVert = capacity at -8 °C ÷ 1,000 × $120 (ENERGY STAR cold climate), capped at the cost; only Hydro-Québec confirms the grant. Indoor sound: minimum / maximum, in dB. A 9,000 BTU/h wall unit on its own is not eligible for LogisVert.
It draws in air, drains defrost water and can be heard outside. Three reasons to choose its spot carefully.
Example clearances, from a Fujitsu manual: each model has its own, in its installation manual.
Five choices, one number: the estimated sound level at the property line.
estimated at 3 m, versus 50 dB allowed. A quiet room: 40 dB(A); a conversation at 1 m: 55 dB(A) (CCOHS).
Indicative estimate based on the AHRI 275 standard, from the 1 m level listed on our spec sheets. Wind, background noise and real surfaces change the result.
| Where | Noise allowed | Permit | Good to know |
|---|---|---|---|
| Ahuntsic-Cartierville | 50 dB at the property line | — | See the page |
| Lachine | 50 dB at the property line | — | The city may require an acoustic study or a screen. See the page |
| Mercier–Hochelaga-Maisonneuve | 55 dB from 7 a.m. to 10 p.m., 52 dB at night | — | See the page |
| Montréal-Nord | 50 dB at the property line | Yes | See the page |
| Saint-Léonard | 50 dB at the property line | Yes | See the page |
| Rosemont–La Petite-Patrie | Standards in the commitment form | Yes | Study and screen for large equipment. See the page |
| Verdun | — | Yes | Screen possible on rooftops. See the page |
| Outremont, Ville-Marie, Villeray–Saint-Michel–Parc-Extension | — | Yes | See the page |
| Longueuil (Saint-Hubert, Greenfield Park, Vieux-Longueuil) | 53 dB(A) | No | 1 m from a lot line, 2 m high at most, hidden from the street if 2 m or less. See the page |
| Laval | — | No, if sections 265 and 266 of the planning code are met | Fines from $400 to $1,000. See the page |
Ville de Montréal, summary by borough (updated August 3, 2026); Ville de Longueuil (Noise page and Heat pump sheet, July 2025); Ville de Laval (April 4, 2025). “—”: nothing specified in the official summary. Always check the by-law in force. All cities and boroughs.
Touch a season. Every setting comes from Hydro-Québec or NRCan.
Example from Hydro-Québec’s LogisVert leaflet
Let it run continuously, at the same setpoint.Hydro-Québec
At night, a 2 °C setback at most, or a smart thermostat that restarts early.NRCan
Forget Auto mode.Hydro-Québec
Keep the outdoor unit clear of snow, ice and leaves.Hydro-Québec
Steam on the outdoor unit? That’s the defrost cycle.NRCan
Rate Flex D: from December 1 to March 31, up to 30 events and 120 hours per winter, announced the day before.
Hydro-Québec’s example for a 21 °C setpoint. Hours on the chart: midnight to 11 p.m.
at the peak price that day, 46.463¢ per kWh. Preheat 2 h before, lower to 20 °C during, go back to 21 °C.
Choose your model’s minimum temperature. Both charts update.
On February 4, 2023, it hit -29.3 °C. Drag the slider, hour by hour.
Montréal airport, hourly readings from Environment and Climate Change Canada. The 4 a.m. reading on February 4 is missing: interpolated.
Below the minimum temperature listed by the manufacturer, the baseboards heat alone.
How many hours per year below your model’s limit, and what share of heating needs stays above it.
Hours per year at each temperature, Montréal airport, July 2015 to June 2025. AirGreen calculation from Environment Canada hourly readings, degree-hours below 18 °C. Indicative.
of winter heating needs come above -26 °C, the limit you chose.
Neglecting maintenance means lower efficiency, a higher bill and, eventually, breakdowns. Here is what you do, and what the technician does.
Every month when it runs hard, at least at the start of each season (Hydro-Québec); every 3 months at most (NRCan).
Lift the front panel of the indoor head, with the unit off.
They slide down, no tools needed.
Room-temperature water, no detergent (Hydro-Québec).
Completely, out of the sun, before putting them back.
NRCan recommends having the yearly service done by a qualified contractor.
Hydro-Québec estimates a poorly maintained unit can use up to 25% more electricity, and a dirty filter costs it 10 to 30% of its efficiency.
per year, at worst, on $500 of electricity: up to 25% more for a poorly maintained unit (Hydro-Québec).
Eight normal behaviours and four signs worth a call, from the manufacturers’ manuals and our service team.
That’s the defrost cycle: the outdoor fan stops, the frost melts, then heating resumes.
Source: NRCan (2025-12-24)
LogisVert, filters, peaks, service, legal warranty: every date is calculated from today.
to send your LogisVert application to Hydro-Québec, with your invoice.
Keep the itemized invoice and the model numbers of both units.
Then every month in peak season (Hydro-Québec). Water, no detergent, dried out of the sun.
Preheat by 1 or 2 degrees before each event, lower during, then go back.
$120 per 1,000 BTU/h of heating at -8 °C for an ENERGY STAR cold-climate model, $50 for a regular ENERGY STAR unit. Outdoor unit of 12,000 BTU/h and up.
NRCan recommends it every year. A poorly maintained unit can use up to 25% more (Hydro-Québec).
New Québec law: 6 years for a heat pump, from delivery, for contracts signed on or after October 5, 2026. Normal maintenance remains your responsibility.
15 to 20 years for an air-source heat pump, according to NRCan, with yearly servicing.
Dates calculated from today. LogisVert: no later than 9 months after installation (guide v1.10). Only Hydro-Québec confirms the grant.
The current month is already selected. 1981-2010 normals for Montréal airport (Environment Canada).
Heat · from the first cold nights
The number of the month. 15.5 °C on average: 94 heating degree-days, 21 cooling.
Sizing, installation and maintenance make the difference. Work with experienced HVAC professionals to choose the unit and install it.
The right size, ENERGY STAR cold climate, one head per living space.
A head that can breathe, an outdoor unit above the snow, away from the neighbours.
Heat mode, baseboards 2 to 3 °C lower, a steady setpoint. In summer, 22 to 25 °C.
Clean filters every month in season, a technician once a year.
Hydro-Québec gives two benchmarks: about 12,000 BTU/h for 750 sq. ft in its capacity guide, and 15,000 BTU/h for 750 sq. ft in its seven points to consider. In Québec, heating is what decides. An on-site assessment takes the ceilings, windows and insulation into account.
In winter, yes. Hydro-Québec recommends letting it run continuously at a steady setpoint. If you lower the temperature at night, NRCan advises 2 °C at most: the heat pump catches up slowly, and the baseboards would do the work in the morning.
Heat mode, never Auto (Hydro-Québec). NRCan adds: fan on high or automatic, and louvres pointing down.
2 to 3 °C below the heat pump’s setpoint. Example from Hydro-Québec’s LogisVert leaflet: heat pump at 20 °C, baseboards at 18 °C. The baseboards remain your backup heat in deep cold and during defrost.
Every month when the unit runs a lot, and at least at the start of each season (Hydro-Québec). NRCan sets the maximum at 3 months. Rinse them with room-temperature water, no detergent, and let them dry completely out of the sun.
It’s the defrost cycle. The heat pump reverses for a few minutes to melt the frost on the outdoor coil; the outdoor fan stops and steam escapes. Depending on the model, it starts on demand or every 30, 60 or 90 minutes.
It depends on the model. NRCan puts the limit of recent models between -15 and -25 °C; our cold-climate wall units list -26 to -30 °C on their spec sheets. The colder it gets, the more their capacity drops. In Montréal, from 2015 to 2025, it was below -20 °C about 50 hours a year.
On a stand higher than drifting snow (manufacturers’ manuals), clear of snow, ice and leaves (Hydro-Québec), and according to your city’s by-law. Several Montréal boroughs limit noise to 50 dB at the property line; Longueuil requires 1 m from a lot line.
It depends on the city. In Montréal, seven boroughs require a permit, including Montréal-Nord, Rosemont–La Petite-Patrie, Verdun and Ville-Marie. Longueuil doesn’t. Laval doesn’t if sections 265 and 266 of its planning code are met. Our Permits and by-laws page has the details by city.
$120 per 1,000 BTU/h of heating capacity at -8 °C for an ENERGY STAR cold-climate model, $50 for a regular ENERGY STAR unit. The outdoor unit must be at least 12,000 BTU/h, the application must be made within 9 months, and the grant can’t exceed the cost. Example: Sharp CHU 12,000, 18,900 BTU/h at -8 °C, $2,268.
15 to 20 years for an air-source heat pump, according to NRCan, with a yearly service visit by a qualified contractor. Hydro-Québec estimates a poorly maintained unit can use up to 25% more electricity.
Yes. In summer, use Cool mode with the fan on low: it removes more humidity (NRCan). Hydro-Québec suggests a setpoint of 22 to 25 °C. Health Canada targets indoor humidity between 30 and 50%.
In the room you use the most, at the height the manual calls for (at least 2.3 to 2.5 m from the floor in the manuals we checked), away from strong heat sources, with nothing in front of the air intake and outlet, and not right above an electrical appliance (Gree manuals). Leave the specified clearances, for example 15 cm above.
One head mainly heats the room it is in (NRCan). For several closed rooms, you add heads on the same outdoor unit (multi-zone) or one heat pump per floor, as Hydro-Québec suggests for a two-storey home without forced air. Keep the baseboards as backup for deep cold.
An advisor assesses your home on site, suggests ENERGY STAR cold-climate models with their indicative LogisVert amount, and sends you a detailed quote within 24 h.
Hydro-Québec does not solicit by phone or door to door for LogisVert. Only Hydro-Québec approves and pays the grant.
Sources. Sources checked on September 24, 2026. Natural Resources Canada: “Heating and cooling with a heat pump” (modified December 24, 2025). Hydro-Québec: LogisVert leaflet “Tips for using a heat pump” (2025G386F, rev. 07/2026); guide “Using and maintaining a heat pump” (version 1, March 16, 2026); tips “Seven tips”, “Using your heat pump in winter”, “Six summer tips”, “Seven points to consider” and “Choosing the right capacity”; Rate Flex D and rate schedule as of April 1, 2026; LogisVert residential participation guide v1.10 (September 15, 2026). EPA ENERGY STAR: Heat Pump specification v6.2. Installation manuals from Fujitsu General (outdoor unit, part 9374747160), Gree and Mitsubishi. AHRI 275 (application of sound ratings). Ville de Montréal (update of August 3, 2026), Ville de Longueuil (July 2025), Ville de Laval (April 4, 2025). CCOHS. Health Canada. Gree VIREO+ ULTRA installation and owner’s manual (031519). Environment and Climate Change Canada: 1981-2010 normals and hourly readings for MONTREAL INTL A, July 2015 to June 2025 (AirGreen calculation, indicative). AirGreen spec sheets and AHRI numbers read on September 24, 2026. Amounts shown are estimates; only the responsible organizations confirm the assistance granted.