Installation of a Haxxair wall-mounted heat pump in Rosemont–La Petite-Patrie
AirGreen installs a Haxxair wall-mounted heat pump in Rosemont–La Petite-Patrie: short path, gravity drainage, clean finishes and HVAC maintenance for lasting comfort in Greater Montreal.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Precise comfort and careful finishing in a Rosemont apartment
At AirGreen , we work every day in homes across Greater Montreal to provide reliable, cost-effective, and sustainable HVAC heating and cooling solutions. In this Rosemont–La Petite-Patrie apartment, our mission is to install a Haxxair wall-mounted heat pump and carefully integrate it into a clean-lined interior. The client's goal is twofold: to achieve a stable temperature in both winter and summer, and to maintain a discreet aesthetic with a smooth white ceiling.
The context: a living space that requires precision
The Haxxair indoor unit is positioned high on the wall, close to the ceiling. The illuminated display on the front shows the setpoint (here 28°C at the time of testing), which is useful for checking the mode and operating status at a glance. The living room has simple surfaces; therefore, a compact, quiet indoor head was required, capable of finely directing the airflow to avoid direct currents into the living area.
Equipment selection and sizing
-
Device type : reversible wall-mounted heat pump (mini-split), ideal for apartments and plexes in the area.
-
Brand : Haxxair – known for its quiet units and easy-to-use electronics.
-
Capacity : selected according to the volume of the living room, the insulation and the orientation of the windows (common range 9,000 to 18,000 BTU/h for this type of space).
-
Efficiency : high seasonal air conditioning performance and good heating efficiency at low temperatures, with inverter modulation to limit on/off cycles and optimize kWh consumption.
-
Comfort : dehumidification mode useful in mid-season, automatic restart after failure and timer.
Our sizing method is based on a precise survey (measurement, losses, air infiltration, solar gains) in order to avoid an oversized unit that blows too hard, or an undersized one that struggles to keep up during cold peaks.
Refrigeration path and condensate evacuation
In this project, we favored a short route : a single hole behind the interior head to reach the exterior, then refrigeration and electrical connections guided in a white capping matching the facade. This configuration reduces pressure losses, simplifies subsequent service and improves aesthetics.
Condensate drainage is by gravity : the head being installed high, we create the necessary slope so that the water flows naturally towards the outside without a lifting pump , minimizing the risk of noise and maintenance.
Integration, sound levels and air settings
The orientation of the shutter (horizontal and vertical sweep) is set to evenly mix the volume of the living room without direct blowing on the sofa. In night mode , the Haxxair unit reduces the brightness of the display and adopts a softer regulation law: an advantage for rest. The result is a very contained noise level at the first ventilation level , comparable to a whisper, a guarantee of comfort in everyday life.
Key Steps to AirGreen HVAC Installation
-
Protection and preparation : tarpaulins, caulking the hole, checking ceiling clearances and center distances.
-
Fixing : Wall plate anchored level, laser controlled to ensure perfect alignment with the ceiling.
-
Drilling : controlled angle drill with outward slope ; insertion of an insulated bulkhead.
-
Connections : compliant flares, torques on the dynamometer, vacuum drawing until stable pressure, then release of the fluid and leak test.
-
Power supply : dedicated circuit with standard circuit breaker, clearly marked on the electrical panel.
-
Finishing touches : capping and clean joints, contours redone, complete functional test (hot/cold, defrosting, condensates).
-
Customer provided with : usage tips, HVAC maintenance , service schedule and support contact information.
HVAC maintenance: actions that extend lifespan
-
Filters : Dust every 4 to 6 weeks during periods of heavy use. A clean filter improves airflow and efficiency.
-
Heat exchanger : gentle cleaning of the fins to preserve performance and avoid odors.
-
Condensates : check the slope and drainage at the start of each summer.
-
Outdoor unit : 30 to 45 cm clearance all around, snow removal in winter and visual inspection of supports/brackets.
-
Annual service : professional AirGreen inspection including pressure measurement, intensity control, parameter updates and deep cleaning.
Comfort and savings tips
-
Stable setting : in a Montreal home, aiming for 22–23°C in heating mode and 24–25°C in cooling mode limits overconsumption.
-
Open doors : for the heat pump to serve as a central wall-mounted air conditioner for the home, maintain air circulation between rooms.
-
Curtains/Blinds : Managing solar gain in summer reduces the air conditioning load.
-
Timer : Programming night or absence lowering improves the actual HSPF over the season.
Indoor air quality: an often underestimated benefit
The Haxxair unit's filtration captures dust and allergens. During heating periods, the uniform blown air reduces stratification (warm ceiling, cold floor) and contributes to higher perceived comfort with the same consumption. For sensitive occupants, we offer optional reinforced filter media and a replacement schedule.
Finishes and aesthetics: the AirGreen signature
The final result blends in with the apartment's white ceilings: invisible screws, flush capping , and linear alignment. Blower tests confirm the absence of unwanted vibrations. The exterior support (brackets or slab, depending on the facade) is chosen to maintain air circulation and facilitate snow removal. The openings are sealed to prevent any air or moisture infiltration, a critical point in Montreal's climate.
Measurable results and peace of mind for the client
Once commissioned, the temperature reduction time in summer is short; in winter, the setpoint increase is smooth thanks to the inverter. The electricity bill is stabilized compared to convectors or portable air conditioning, and the reduced noise level allows continuous use, even during power demands.
Grants and Eligibility
Quebec's energy efficiency programs are evolving regularly. Many high-performance wall-mounted heat pump models may be eligible if they meet the requirements (specific certifications and performance). We support our clients in Montreal, Laval, Longueuil, the North Shore, and the South Shore to verify the criteria of the Haxxair model installed, gather the necessary evidence (certification numbers, photos, detailed invoices), and submit the application on time.
Pitfalls to avoid and good practices
-
Undersize the device: it will run at full speed, make noise and wear out prematurely.
-
Unnecessarily long refrigeration path : loss of capacity and risk of insufficient oiling. We favor lengths < 3 m when the configuration allows.
-
Lack of drain slope : a common cause of internal leaks. The slope is checked with a spirit level.
-
Exterior support not clear : Snow and ice can hinder airflow. We choose a suitable height and a solid anchor.
-
Neglected maintenance : a clogged filter is enough to increase consumption and reduce comfort.
Why AirGreen?
-
Local expertise in buildings and plexes in Rosemont–La Petite-Patrie , Plateau, Villeray, Saint-Léonard, etc.
-
Certified team : standardized procedures (torque meter torques, deep vacuum, leak tests).
-
Complete service : HVAC installation , HVAC maintenance , rapid troubleshooting and administrative support for subsidies.
-
Transparency : detailed quote (lengths, accessories, supports), realistic schedule, post-installation monitoring.
In short, this Haxxair heat pump provides an elegant and measured response to the needs of an apartment in Rosemont–La Petite-Patrie : 4-season comfort, energy efficiency and impeccable integration. For a similar project in Montreal , Laval , Longueuil , on the North Shore or the South Shore , our team advises, sizes and installs with the same demanding results.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).