Installation d’une Sharp (gamme R-32) thermopompe murale au Plateau-Mont-Royal
Reading time: 6'

Installation of a Sharp (R-32 range) wall-mounted heat pump in Plateau-Mont-Royal

A typical Plateau-Mont-Royal construction site: a lush courtyard, century-old brick façade, and side-alley access. Here, our team is replacing a seasonal backup system with a new-generation Sharp R-32 wall-mounted heat pump , providing four-season comfort without compromising the building's aesthetics.

A choice designed for the built environment of the Plateau

Plateau homes often feature load-bearing brick walls, close cornices, and tree-lined courtyards. We opted for a compact, quiet, and economical HVAC system capable of low-temperature heating and efficient cooling of the open living areas typical of apartment and plex renovations.

Why a Sharp wall-mounted heat pump (R-32)

  • Inverter modulation : gentle temperature rise, stability and reduced consumption.

  • R-32 refrigerant : lower climate impact compared to R-410A, better volumetric capacity.

  • Acoustic comfort : fan and compressor at low speed, ideal for the quiet streets of the Plateau.

  • Filtration & mixing : consistent air quality thanks to sweeping and easy-access filters.

Outdoor installation: clean, robust, reversible

We install the condenser on steel wall brackets , at a height high enough to protect the coil from winter buildup and facilitate maintenance. Under the unit, blue silent blocks absorb micro-vibrations: it's discreet for the neighborhood and comfortable inside.

  • Facade : red brick, anchors sealed in the joint, dowels adapted to the substrate.

  • Clearances : respect distances from the soffit and openings to avoid air recirculation.

  • Disconnect box : installed within easy reach, waterproof, for safety and maintenance.

  • Plant management : the Virginia creeper is cut back around the blowing template to preserve heat exchange.

Visible details that make the difference

  • Triangular brackets : rigidity and load distribution, perfect for refurbished old walls.

  • Right-hand side refrigeration path : protected and insulated connections, curvature radius respected.

  • Wiring : bundled and secured to prevent flapping in the wind; neat descent to disconnection.

  • Defrost drainage : drip planned outside traffic areas to avoid ice in winter.

Optimized indoor/outdoor route

The wall head is positioned on a side wall, facing directly towards the living areas. The drilling is carried out behind the unit , with a slight slope towards the outside to allow gravity drainage of the condensate in summer.

  • Total line length : short (approx. 3–4 m), which minimizes losses and improves seasonal yield.

  • Leak -tightness : Deep vacuum, leak testing and torque tightening—our AirGreen standards.

  • Dedicated power supply : circuit breaker size and cable section in accordance with the manufacturer and the Code.

Sizing and Use: The Right Capacity, Not the Biggest

On the Plateau, the volumes are often open-plan but compact. We size around 9,000 to 12,000 BTU depending on the envelope and sunlight, with a margin for afternoon heat. The objective: maintain the setpoint (e.g. 22°C) in auto speed , without oversizing, for a high COP and minimal noise.

Concrete result for the occupants

  • Daily silence (end of the hum of old portable devices).

  • Directed airflow over living areas, with no drafts on the sofa or dining table.

  • Windows freed (no more sheath to obstruct opening).

  • Controlled bills thanks to inverter modulation and R-32 refrigerant .

Brand and range: Sharp, efficiency and discreet design

The Sharp signature is evident in the sleek condenser grille and Eco Inverter screen printing. We select a recent R-32 range perfectly suited to Montreal winters. Depending on the electrical configuration and thermal load, we offer the most relevant capacity, while retaining the advantages of:

  • sustained low temperatures in heating,

  • optimized defrosting for short cycles,

  • precise control (remote control and programming).

(When the exact model number is not required by the customer in the public communication, we relate the machine to the installed Sharp R-32 family and provide the technical data sheets with the contract.)

AirGreen operating mode: visible and invisible quality

Before the work

  • Technical visit: identification of drilling paths , verification of the brick structure, locations of joists and electrical lines.

  • Discussion with the client on the orientation of the blowing , the installation height, the clearances around the curtains and light fixtures.

During the works

  • Protection of the passage areas and clean drilling at the correct angle for the drain.

  • Tooled flares, brazing without overheating the insulation, testing under nitrogen and vacuum < 500 microns .

  • Initial settings: auto speed, horizontal/vertical scanning , comfort settings.

After the work

  • Explanations provided : cleaning filters, use in heating mode in very cold weather, noise reduction management (night mode).

  • Acoustic check on the facade and in the courtyard: no unwanted transmission towards the interior or to the neighbors.

HVAC maintenance: simple and profitable over time

  • Filters : rinse/vacuuming every 4 to 8 weeks during intensive periods.

  • Condenser : brushing with snow melt, without direct high pressure.

  • Annual AirGreen inspection : exchangers, electrical tightening, condensate, parameter updates, leak check.

  • Vegetation : light pruning each spring to keep the fins clear.

Our HVAC maintenance agreements ensure continued performance and protect the manufacturer's warranty .

Grants and Compliance

R-32 wall-mounted heat pumps with good seasonal performance and cold weather capability are generally eligible for energy efficiency programs in Quebec . We support our clients in the Montreal metropolitan area, Laval, Longueuil, North Shore and South Shore to verify eligibility, prepare proof of performance and submit applications on time.

Best practices + pitfalls to avoid (AirGreen feedback)

  • Do not stick the outdoor unit under the cornice: there must be clearance for air supply and discharge.

  • Avoid unnecessary excess lengths : they penalize efficiency and heating response.

  • Anticipate wintering : route the defrosting flow away from pedestrian walkways to avoid ice.

  • Vegetation : Vines are beautiful, but they must never obstruct the condenser grille.

  • Electricity : Dedicated circuit and accessible disconnection ; no extension cords, no power strips.

What the customer remembers

From the moment it is put into service, the house gains in silence , thermal stability and freedom of use (clear windows, intact courtyard). The Plateau-Mont-Royal requires respect for the building and the tranquility of the alleys: the installation on brackets with silent blocks and a clean path meets these requirements exactly.

AirGreen, your HVAC partner in Greater Montreal

We install, maintain and repair wall-mounted heat pumps , wall-mounted air conditioners and MultiZone systems throughout Montreal , Laval , Longueuil , as well as on the North Shore and South Shore . Our commitment: accurate sizing , impeccable HVAC installation and responsive after-sales service .

Leave a comment

Please note, comments need to be approved before they are published.