Job sheet · Project

Installation of a Tosot LomoPlus UltraHeat Wall-Mounted DoubleZone Heat Pump in Outremont

Dive into the details of the recent installation of a Tosot LomoPlus UltraHeat by AirGreen in Outremont. Experience our dedication to quality HVAC services and customer satisfaction.

By AirGreen Climatisation & Chauffage Admin3 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
3 minto read the whole story
–type of installation
2023year published
At a glance

The job on one screen

Installation of a Tosot LomoPlus UltraHeat Wall-Mounted DoubleZone Heat Pump in Outremont
Installation of a Tosot LomoPlus UltraHeat Wall-Mounted DoubleZone Heat Pump in Outremont
The full story

The article, chapter by chapter

A Complicated Installation Masterfully Handled by AirGreen

At AirGreen, we pride ourselves on delivering top-tier HVAC services across Montreal, Laval, Longueuil, North Shore, and South Shore. Our recent installation in Outremont stands as a testament to our commitment to quality and customer satisfaction.

The Tosot LomoPlus UltraHeat: A Powerhouse of Efficiency

The star of this installation was the Tosot LomoPlus UltraHeat, a wall-mounted double-zone heat pump that is a perfect blend of efficiency and innovation. This model, with two heads of 12,000 BTU and a 24,000 BTU compressor, is designed to provide optimal comfort while being energy efficient. It boasts an efficiency rating of 23.0 SEER, making it eligible for a federal grant of $2500.

The LomoPlus UltraHeat is also an Energy Star® certified model, ensuring it meets the highest standards of energy efficiency and environmental protection. It comes with optional WiFi for smart and convenient control. The sound pressure level of the model, both exterior (60.0 dB(A)) and interior, ensures quiet operation, making it an ideal choice for homes and offices.

The Installation Process: Complex Yet Efficient

The installation process was complex, given the need to install two separate heads. The first one was relatively straightforward as it was near the compressor. The second one posed more of a challenge as it was on the complete opposite side of the apartment! We had to be mindful of respecting the piping limits and noise limitation for neighbours.

Despite the complexity of the installation, our team ensured that every detail was handled with the utmost precision. The result was a flawless installation that left our customer extremely satisfied. We also installed a draining pump and had a special team come in to do some finishing work with gyprock and paint. The customer was extremely pleased with our turnkey installation process and our 10-year warranty on everything, including labour!

Why Choose AirGreen?

Choosing AirGreen for your HVAC needs means choosing quality, professionalism, and customer satisfaction. We understand that every installation is unique, and we tailor our services to meet your specific needs. Our team of experienced professionals is dedicated to providing you with the best HVAC solutions, ensuring your comfort and satisfaction.

Whether you're looking for a simple wall-mounted heat pump like the Tosot LomoPlus UltraHeat or a more complex HVAC solution, we've got you covered. We offer a wide range of HVAC services, from installation to maintenance and repair, all aimed at enhancing your indoor comfort.

Conclusion

Our recent installation in Outremont is just one example of our commitment to quality and customer satisfaction. At AirGreen, we believe in delivering HVAC solutions that not only meet but exceed your expectations.

So, if you're in Montreal, Laval, Longueuil, North Shore, or South Shore and need HVAC services, look no further than AirGreen. We're here to provide you with the best HVAC solutions tailored to your specific needs.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment