Job sheet · Project

Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore

Elevate your home comfort with the Sharp ZU1—installed high on the wall for efficiency and aesthetics. Choose AirGreen for expert HVAC solutions!

By AirGreen Climatisation & Chauffage Admin3 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
3 minto read the whole story
–type of installation
2024year published
At a glance

The job on one screen

Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore
Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Elevating Comfort with Strategic Installation

In the charming town of Charlemagne on the North Shore, a family's quest for year-round comfort was met with a state-of-the-art solution by AirGreen. Our latest project involved installing the highly efficient Sharp ZU1 18,000 BTU wall-mounted heat pump, a choice that promises not only enhanced comfort but also remarkable energy savings.

The Challenge of Space and Aesthetics

For many homeowners, the dilemma of where to place the external unit of a heat pump without disrupting the home's aesthetics or utilizing valuable garden space is a significant one. This installation was no different. Our solution was both practical and innovative—mounting the outdoor compressor high on the wall. This approach not only saved precious ground space but also protected the unit from potential hazards like snow accumulation and inadvertent impacts.

Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore

Sharp ZU1: A Synthesis of Technology and Efficiency

The Sharp ZU1 model is no ordinary heat pump. It integrates several advanced features designed to provide optimal comfort and impressive energy efficiency:

  • Heating and Cooling Capacity: Capable of providing comfortable temperatures even when exterior temperatures drop to -27°C.
  • Energy Efficiency: Boasting a 24.0 SEER rating, this model is one of the most energy-efficient on the market.
  • Plasmacluster Technology: Offers superior air purification, effectively neutralizing airborne bacteria, viruses, and allergens.
  • Coanda Airflow Control: Ensures even temperature distribution throughout the room without direct drafts on the occupants.
  • Innovative Refrigerant: Uses R-32 freon, which is not only more energy-efficient but also less impactful on the environment.

Installation Highlights

Our installation team faced the technical challenge of securely mounting the unit at a height, which was skillfully accomplished using robust mounting brackets and ensuring that all safety standards were strictly followed. The unit's placement was meticulously planned to ensure optimal performance and minimal visual impact on the building's facade.

The strategic placement allows for easier maintenance and reduces the risk of obstruction or accidental damage. Moreover, the elevated position helps in maintaining the unit's efficiency during heavy snowfall, a common scenario in Quebec's winters.

Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore

Advantages of the Sharp ZU1 for Charlemagne Residents

Residents of Charlemagne can look forward to numerous benefits from this installation:

  • Seasonal Versatility: Whether braving the cold winters or seeking relief during the hot summers, this heat pump is designed to handle extreme temperatures with ease.
  • Cost Efficiency: The energy-efficient nature of the ZU1 model not only lowers energy bills but also qualifies homeowners for the $2640 LogisVert Grant from Hydro-Québec.
  • Enhanced Air Quality: The Plasmacluster technology ensures that the indoor air is clean and healthy, an essential feature for families looking to enhance their living environment.

Client Testimonial

The homeowners expressed immense satisfaction with the outcome of the installation. They appreciated how AirGreen handled the project with professionalism and attention to detail. The discreet yet effective placement of the unit was particularly praised, as it did not compromise the aesthetic appeal of their home while delivering the expected performance.

Why Choose AirGreen for Your HVAC Needs?

At AirGreen, we pride ourselves on providing top-notch HVAC solutions that blend seamlessly with our clients' needs and the architectural aesthetics of their homes. Our commitment to using advanced technology and sustainable practices ensures that each installation is not just about improving comfort but also about contributing positively to the environment.

Choosing us means opting for a partner who values your comfort and strives to deliver it in the most efficient and sustainable way possible.

Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Charlemagne, North Shore

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment