No permit Permits and bylaws · Checked on September 30, 2026

Heat pumps in Candiac: permits and bylaws

Planning a heat pump or an air conditioner in Candiac? Here is what the bylaws say: the permit, the distance from the lot lines, where the unit can go and the noise limit. It all comes from the official texts.

PermitNo permitNo certificate of authorization required
FeeNot applicableNo permit is required.
Distance from lot lines2 m2 m from the side and rear lot lines, no more than 1.5 m from a wall of the house
Noise limit55 / 50 dBOver 55 dB by day (7 a.m. to 9 p.m.) or 50 dB at night (9 p.m. to 7 a.m.), measured at the complainant’s property: not allowed
01 · Where the unit can go

Five spots, one answer for each.

Each answer is the bylaw rule, in short. “Not specified” means the text does not say: ask urban planning.

BackyardWith conditions

At least 2 m from the lot lines, no more than 1.5 m from a wall of the house, hidden from the street.

Side yardWith conditions

At least 2 m from the lot lines, no more than 1.5 m from a wall of the house, hidden from the street.

Front yardNot allowed

Not allowed in the front yard or the secondary front yard.

BalconyNot specified

Not specified in the bylaw: confirm with urban planning.

Flat roofWith conditions

Roof: not visible from the street, hidden by an architectural element that matches the building.

02 · Before the work

Good to know, and who to call.

Good to know

  • Semi-detached or row house: no more than 1 m from a wall of the house.
  • On the ground or on a purpose-built stand, hidden from the street by an opaque fence, landscaping or a dense hedge.
  • In apartment buildings, noise is measured inside the complainant’s unit.
Who to call Urban planning department, 450 444-6050, permis@candiac.ca Ask them to confirm the rules for your address before the work.
03 · Questions

The short answers.

Do you need a permit to install a heat pump in Candiac?

No certificate of authorization required.

How far from the lot lines must the unit be?

2 m from the side and rear lot lines, no more than 1.5 m from a wall of the house.

Can a heat pump go in the front yard?

No. Not allowed in the front yard or the secondary front yard.

What is the noise limit?

Over 55 dB by day (7 a.m. to 9 p.m.) or 50 dB at night (9 p.m. to 7 a.m.), measured at the complainant’s property: not allowed.

Who should I call to confirm before the work?

Urban planning department, 450 444-6050, permis@candiac.ca.

04 · Sources

Read at the source.

Sources: Zoning bylaw 5000, s. 222, 337 (row 32) and 359; permits bylaw 5005, s. 41 (Table 4-1); nuisance bylaw 1010-01, s. 3.2.4 and 3.3 (administrative consolidations of July 20, 2026 (5000, 5005) and July 15, 2026 (1010-01)).

Checked by AirGreen on September 30, 2026.

This page is a summary. The official bylaw prevails. Confirm with the city before the work.

Compare the rules of other municipalities

AirGreen · Air conditioning and heating

A heat pump project in Candiac?

We come and see your property, and the estimate is free.

RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16.
Free on-site estimate
Quote within 24 hours