Breakdown? Call 514 316-2973
Commercial HVAC emergency · Updated November 2, 2026

Heating, cooling or refrigeration down: the right steps first, a technician on priority. Commercial emergency service in Montréal, Laval, Longueuil, the South Shore and the North Shore

During business hours, breakdown calls go ahead of scheduled appointments. Mon–Thu 8 a.m.–6 p.m. · Fri 8 a.m.–4 p.m.. The triage below tells you what to do while you wait.

4 °Cmaximum for refrigerated food (MAPAQ)
20 °Cminimum for office work (RSST, Schedule IV)
911gas smell: get out first, then call
514 316-2973Montréal–Laval
514 316-3007South Shore
Mon–Thu8 a.m. to 6 p.m.
Friday8 a.m. to 4 p.m.
01 · Triage

What is happening? Tap the situation, we tell you what to do.

Three safe steps, what the technician will ask and the urgency level. Dangerous situations come first.

02 · Temperature

Does your thermometer say “emergency”?

Pick the place and slide to the temperature you read. We compare it with the limit that applies.

What temperature are you reading?

03 · What downtime costs

An hour of downtime costs more than you think. Run the numbers with yours.

Lost sales, idle wages, discarded stock: the curve shows how the bill climbs with each hour.

Your numbers

The starting values are an example. Replace them with yours.

$0$5,000
050
$15$80
$0$50,000
1 h24 h
1 h48 h
0 h24 h48 h
What this breakdown costs
–
Lost sales–
Wages without output–
Lost stock–
Average cost per hour–

Calculated with your numbers only. Stock counts in full once it passes its safe time.

Schedule maintenance
04 · Game plan

Breakdown mid-shift: check off as you go.

The button copies a summary to paste in a text or email: situation, temperature, steps done.

Six steps, in order

0 / 6 steps done

Call 514 316-2973
05 · What we repair

The equipment we get running again, and what goes to a partner.

Heat pumps and air conditioning

Wall units, cassettes, central systems, rooftop units, VRF.

15.10
Electric heating

Unit heaters, electric coils, baseboards, air curtains.

16
Refrigeration

Walk-ins, display cases, freezers, compressors.

15.10
Ventilation

Fans, air exchangers, make-up air, belts.

15.8
Controls and electrical

Thermostats, contactors, relays, equipment power.

16
Gas burners and valves

Gas side of rooftop units and furnaces: licensed partner.

Partner 15.2
06 · After the breakdown

Get running again, then keep it from happening again.

Written diagnosis

The cause, not just the symptom.

Repair or make safe

If a part is missing, we make it safe and tell you when it arrives.

Leak test

After a leak repair on 20 kW and up: between day 30 and day 60.

Maintenance plan

A calendar so you no longer wait for the breakdown.

Priced replacement

If the unit is at end of life: options and possible incentives.

07 · Rules

The limits that turn a breakdown into an emergency.

Tap a card for details.

08 · Frequently asked questions

What people ask us during a breakdown.

What are your hours for emergencies?

During business hours (Mon–Thu 8 a.m.–6 p.m., Fri 8 a.m.–4 p.m.), breakdown calls go ahead of scheduled appointments. Montréal–Laval: 514 316-2973. South Shore: 514 316-3007.

It smells like gas. What should I do?

Leave right away without touching switches or devices, then dial 911. Énergir also lists 1 800 361-8003 where 911 is not available. Do not go back in until emergency services say so.

My walk-in is warming up. What do I do while waiting?

Keep the door closed, note the temperature and time, and move the most sensitive products. Refrigerated food must stay at 4 °C or colder (MAPAQ). Call us with the unit model.

The breaker trips. Can I reset it?

Once. If it trips again, leave it: resetting repeatedly can damage the compressor or hide an electrical fault.

What minimum temperature must be kept for staff?

It depends on the work: 12 to 20 °C under RSST Schedule IV. For office work, it is 20 °C. If it cannot be maintained, a heated room must be provided (RSST, s. 116).

What should I say on the phone?

The address, the unit type (brand and model on the nameplate), the error code shown, what you already checked and the temperature measured. The “Copy for the technician” button prepares this summary.

Do you repair gas rooftop units?

Yes for ventilation, refrigeration and electrical parts. The burner and gas valve go to a partner holding subclass 15.2.

After a leak repair, is there a follow-up?

Yes for units of 20 kW and up: a new leak test between day 30 and day 60 (Halocarbons Regulation). We schedule it with you.

How do I avoid the next breakdown?

With preventive maintenance before each season and by watching the signs: frost, short cycles, a new noise, water under the unit.

The server room is heating up. When should I worry?

ASHRAE recommends 18 to 27 °C at the server air inlet. Above that, open the door if safe, cut non-essential load and call us.

Keep exploring

Your need often touches a neighbouring service.

The services most often combined with this one, plus the full needs search.

AirGreen · Commercial emergency

Keep our number next to the electrical panel.

Montréal–Laval 514 316-2973 · South Shore 514 316-3007. Mon–Thu 8 a.m.–6 p.m. · Fri 8 a.m.–4 p.m..

Gas smell: get out first, then dial 911.
RBQ 5645-9605-01Ventilation 15.8 · Refrigeration 15.10 · Electrical 16
$5M insuranceCivil liability, from start to finish
Free estimateOn site, across Greater Montréal
Quote in 24 hFinal price confirmed before work

Sources checked on November 2, 2026.

  • MAPAQ, food storage temperatures (5M approach).
  • Regulation respecting occupational health and safety (CQLR, c. S-2.1, r. 13), ss. 116 and 117, Schedule IV.
  • Halocarbons Regulation (CQLR, c. Q-2, r. 29), ss. 9 and 21.1, current to June 1, 2026.
  • Énergir, Contact us: emergency and gas smell (accessed November 2, 2026).
  • ASHRAE TC 9.9, recommended range for data rooms.

Amounts shown are indicative estimates, before taxes. Only Hydro-Québec, Énergir and the responsible bodies confirm a rate or an approved incentive.