Clean Comfort DV120 Dehumidifier | Installation in Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It removes 120 pints a day according to the spec sheet. Choose your home's living area, then what you see in the basement.
Living area
What you see in the basement
It's the right size.
For a 2,200 to 2,800 sq ft home with condensation on the walls or windows, you need to remove about 102 pints a day (spec sheet conditions). It removes 120: enough for the house, with some reserve for humid weeks in July.
Calculation: pints a day needed for the living area and the basement's condition, at the spec sheet's test conditions. Our estimator measures the humidity on site before ordering.
What it does, in numbers
$134
Electricity per year
8 h of running a day, May to October
Same calculation for every line: wattage × running hours × 184 days (May to October) × 11.142 ¢/kWh. The unit stops on its own once the target humidity is reached, so its running hours depend on your basement.
Capacities, efficiency and electrical data: manufacturer's spec sheet. Running wattage calculated: litres per day ÷ litres per kWh ÷ 24 h. Cost: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.
What you should know about this one
Published, verifiable facts, not brochure claims.
ExternalA humidity control to plan for
The spec sheet lists no built-in control and names none. The installation guide shows how to wire a digital or external humidity control.
400 cfmAirflow that holds up with ducts
The spec sheet gives 400 cfm with no ducts, 345 cfm at 0.2 in., 295 cfm at 0.4 in. and 250 cfm at 0.6 in. of static pressure. With no ducts, it is the highest airflow of the six Clean Comfort DV units we offer; at 0.2 and 0.4 in., the DV155 moves more (363 and 337 cfm).
6 inIt can ventilate too
The spec sheet states that it provides ventilation. Its 6 in. fresh-air inlet lets the fan bring outdoor air into the house on top of dehumidifying.
E-coatElectrocoated coil
The coil is electrocoated. According to Clean Comfort, this reduces corrosion and helps prevent refrigerant leaks.
120 → 63What it really removes in a basement
120 pints a day at 80 °F, 88 at 70 °F and 63 at 60 °F, always at 60% humidity: those are the numbers on the manufacturer's spec sheet. The cooler the air, the less it removes.
2.9 LWhat it removes per kWh
Each kilowatt-hour removes 2.9 litres of water from the air. At Hydro-Québec's Rate D, that's about 3.8 ¢ per litre.
1 °CIt works in a cold basement
Operating range of 1.1 to 57.2 °C around the unit, per the spec sheet: it keeps working in spring and fall, when the basement is still cool and damp.
MERV 11The filter
Filter: MERV 11, 14 × 17.5 × 1.75 in. It protects the coil and captures part of the particles in the basement air.
6 yrsThe parts warranty
Manufacturer's limited warranty on parts: up to 6 years in an owner-occupied home, 1 year in other cases. It ends if the unit is moved (06/2022 warranty certificate).
What it needs on site
In a finished basement, we put it in the mechanical room and connect it with ducts to keep the noise away from living spaces. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Capacity at 80 °F · 60% RH
- 120 pints/day (56.8 L)
- Capacity at 70 °F · 60% RH
- 88 pints/day
- Capacity at 60 °F · 60% RH
- 63 pints/day
- Energy efficiency
- 2.9 L/kWh
- Power supply
- 120 V · 7.3 A
- Running wattage (calculated)
- ≈ 816 W
- Airflow (0 in. w.g.)
- 400 cfm
- Ducts
- 10 in inlet and outlet · 6 in fresh air
- Filter
- MERV 11, 14 × 17.5 × 1.75 in
- Operating range
- 1.1 to 57.2 °C around the unit
- Weight
- 95 lb
- Warranty
- Up to 6 years on parts
Capacities, efficiency, power supply, airflow, ducts, filter, operating range and weight: manufacturer's spec sheet. Running wattage calculated: 56.8 L per day ÷ 2.9 L/kWh ÷ 24 h. Costs: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We measure the humidity on site, check the drain and the duct route, and give you an installed price.
Clean Comfort DV120: 120 pints a day and 400 cfm with no ducts
The DV120 removes 120 pints of water a day at 80 °F and 60% humidity, 88 pints at 70 °F and 63 pints at 60 °F, per Clean Comfort's spec sheet. Its fan moves 400 cfm with no ducts: at 0 in., that is the highest airflow of the six Clean Comfort dehumidifiers we offer; from 0.2 in. of static pressure, the DV155 moves more (363 cfm versus 345).
Its control
The spec sheet lists no built-in control and names none: it is tied to an external humidity control. The installation guide shared by the DV090 and DV120 shows how to wire a digital or external humidity control; for the DV090, the spec sheet recommends the DV6062A1001 control.
What it needs on site
A 120 V outlet (7.3 A), 10 in. ducts, the 6 in. fresh-air inlet if you want to ventilate, and a drain on the ¾ in. female NPT fitting. The installation guide places it indoors, protected from rain and flooding, with access to the front panel for maintenance. The unit weighs 95 lb.
The warranty
Up to 6 years on parts in an owner-occupied home, 1 year in other cases, under Clean Comfort's 06/2022 warranty certificate. It ends if the unit is moved from where it was first installed.
In-home estimate
No installed price without seeing the house. Our estimator checks the location, the ducts, the drain and the electrical outlet, then we give you a price. Service in Montréal, Laval, Longueuil, the South Shore and the North Shore. Call 514 316-2973.