Honeywell DR120A3000 Dehumidifier | Installation in Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: DR120A3000
120 pints/day2.9 L per kWh5-year warranty
Talk to an HVAC technician · 514 316-2973
5-year parts warrantyDrains continuously
01 · Your basement

Is it the right size for your home?

It removes 120 pints a day according to the spec sheet. Choose your home's living area, then what you see in the basement.

Living area

What you see in the basement

It's the right size.

For a 2,200 to 2,800 sq ft home with condensation on the walls or windows, you need to remove about 102 pints a day (spec sheet conditions). It removes 120: enough for the house, with some reserve for humid weeks in July.

Calculation: pints a day needed for the living area and the basement's condition, at the spec sheet's test conditions. Our estimator measures the humidity on site before ordering.

02 · Performance

What it does, in numbers

120pints
Per day, at 80 °FThat's 56.8 L of water, per the spec sheet.
88pints
Per day, at 70 °FCloser to a basement in summer.
816W
While runningCalculated from the spec sheet.
400cfm
Air movedFan airflow, without ducts.
What it costs to run

$134

Electricity per year

8 h of running a day, May to October

1,000 W baseboard$164
Honeywell DR120A3000$134
100 W light bulb$16

Same calculation for every line: wattage × running hours × 184 days (May to October) × 11.142 ¢/kWh. The unit stops on its own once the target humidity is reached, so its running hours depend on your basement.

1,201kWh
Per year
3.8¢
Per litre of water removed
$0.09
Per hour of running
Pints removed per day, by temperatureAt 60% humidity. The first number is the one on every sales sheet.
80 °F · test bench120 pints
70 °F · a basement in summer88 pints
60 °F · a basement in spring63 pints

Capacities, efficiency and electrical data: manufacturer's spec sheet. Running wattage calculated: litres per day ÷ litres per kWh ÷ 24 h. Cost: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

WallA humidity control to plan for

It has no built-in humidistat. It runs from an external control sold separately, such as the HumidiPRO H6062A1000 or a Prestige IAQ or VisionPRO thermostat. Our estimator includes it in the quote.

400 cfmThe highest airflow of the TrueDRY line

The spec sheet gives 400 cfm with no ducts and 295 cfm at 0.4 in. of static pressure.

20.5 inThe DR90's footprint, 30 more pints

Same length (25.88 in.) and width (14.75 in.) as the DR90; only the height changes, 20.5 in. instead of 19.88. Yet it removes 30 more pints a day at 80 °F.

6 inIt can ventilate too

6 in. fresh-air inlet with a separate ventilation control. Resideo offers the EARD6 motorized damper and the SPRD10 10 in. backdraft damper as accessories.

120 → 63What it really removes in a basement

120 pints a day at 80 °F, 88 at 70 °F and 63 at 60 °F, always at 60% humidity: those are the numbers on the manufacturer's spec sheet. The cooler the air, the less it removes. Most sellers only show the first number.

2.9 LWhat it removes per kWh

Each kilowatt-hour removes 2.9 litres of water from the air. At Hydro-Québec's Rate D, that's about 3.8 ¢ per litre.

40–60%The humidity range to aim for

The range recommended by ASHRAE. Above 60%, a home becomes prone to mold and mildew.

1 °CIt works in a cold basement

Operating range of 1.1 to 57.2 °C per the spec sheet: it keeps working in spring and fall, when the basement is still cool and damp.

MERV 11The filter

Filter: MERV 11, 14 × 17.5 × 1.75 in. It protects the coil and captures part of the particles in the basement air.

5 yrsThe parts warranty

Manufacturer's limited warranty on parts.

04 · Installation

What it needs on site

10 in ductsAir inlet and outlet
6 in fresh-air inletOptional, for ventilation
Floor drainOr a condensate pump
95 lbUnit weight
25.88 × 14.75 × 20.5 inLength × depth × height
120 V · 7.3 AStandard outlet

In a finished basement, we put it in the mechanical room and connect it with ducts to keep the noise away from living spaces. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Capacity at 80 °F · 60% RH
120 pints/day (56.8 L)
Capacity at 70 °F · 60% RH
88 pints/day
Capacity at 60 °F · 60% RH
63 pints/day
Energy efficiency
2.9 L/kWh
Power supply
120 V · 7.3 A
Running wattage (calculated)
≈ 816 W
Airflow (0 in. w.g.)
400 cfm
Ducts
10 in inlet and outlet · 6 in fresh air
Filter
MERV 11, 14 × 17.5 × 1.75 in
Operating range
1.1 to 57.2 °C
Dimensions (L × D × H)
25.88 × 14.75 × 20.5 in
Weight
95 lb
Warranty
5 years on parts

Capacities, efficiency, power supply, airflow, ducts, filter, operating range and weight: manufacturer's spec sheet. Running wattage calculated: 56.8 L per day ÷ 2.9 L/kWh ÷ 24 h. Costs: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Honeywell DR90A3000SmallerHomes up to 2,800 sq ft90 pints
Honeywell DR120A3000You are hereHomes up to 3,500 sq ft120 pints

Talk to an HVAC technician before you choose

We measure the humidity on site, check the drain and the duct route, and give you an installed price.

The Honeywell DR120A3000 is the largest central dehumidifier in Honeywell's DR series. Connected to the ductwork, it removes up to 120 pints of water per day, about 57 litres, according to Resideo's spec sheet, and is intended for homes of up to 3,500 sq ft. Resideo lists it among its ventilating dehumidification systems: a separate fresh air inlet also lets it renew the home's air.

It is the unit we suggest for large homes, multi-storey houses with a finished basement and very airtight buildings where humidity no longer clears on its own.

What sets the DR120A3000 apart

Capacity for a large home

With 120 pints per day under its spec sheet conditions, the DR120A3000 has the reserve needed for a sprawling home or a basement where humidity stays high. The right capacity still depends on the house: floor area, airtightness, number of occupants. We take that into account before recommending this model over a smaller one.

Ventilation and fresh air

Besides the home's air inlet and outlet, the unit has a separate fresh air inlet. With a motorized ventilation damper, sold as an accessory, outdoor air enters the home by passing through the dehumidifier. In a well-sealed house, this helps keep the air from feeling stale.

An external control

The installation guide describes no built-in humidistat for the DR120A3000: it is run by a compatible external control. Resideo names, among others, the HumidiPRO digital humidistat, some VisionPRO thermostats and the Prestige IAQ kit. With a compatible thermostat, temperature and humidity are set from the same screen.

Efficiency and automatic defrost

The spec sheet lists 2.9 litres of water removed per kWh. The unit runs on R-410A refrigerant. When the coil starts to freeze, it stops the compressor and keeps the fan running until the coil warms up.

Large home, large volumes of humid air

In a large home, humidity does not come from a single source. The kitchen, bathrooms, laundry, basement and the occupants themselves produce it every day. In summer, warm, humid air coming in through doors and windows adds to that load, and in spring and fall, cool basements stay damp even when the air conditioning is off.

A central dehumidifier of this capacity treats all that air through the ductwork, without spreading portable units from room to room. There is no tank to empty: the water drains straight to the floor drain.

Installation by AirGreen

A unit this size calls for careful installation. During the estimate visit, our technicians measure the area to treat, examine the ductwork, locate the drain and check that the 120 V electrical circuit suits the unit. Resideo's guide provides for a main return to main return connection, or a dedicated return to a dedicated supply. In the first case, it calls for at least 5 ft between the air inlet and outlet; we plan the duct layout accordingly.

On site, we follow the manufacturer's other rules:

  • installation indoors, protected from water, on the floor or a stable base, properly level;
  • no installation above the cooling coil or any other HVAC component;
  • drain line on a continuous downward slope, with a trap;
  • drain pan if the unit is above a living space;
  • outlet protected by a ground fault circuit interrupter.

We connect the chosen control and set the humidity level with you. A float switch or water sensor can be added to cut the compressor if water builds up, a sensible precaution in a finished basement.

Maintenance tips

Check the filter regularly and replace it with the original Honeywell Home part; in a large home, the unit moves a lot of air and the filter can load up faster. Clear snow and leaves from the outdoor air intake if ventilation is connected. At the start of the warm season, go over the connections and the drain.

Technical specifications

  • Model: Honeywell DR120A3000
  • Type: central dehumidifier with fresh air inlet (ventilating dehumidification system)
  • Capacity: up to 120 pints per day, about 57 litres (spec sheet)
  • Coverage: homes up to 3,500 sq ft
  • Efficiency: 2.9 L of water per kWh
  • Control: compatible external control (HumidiPRO humidistat, VisionPRO thermostats, Prestige IAQ kit)
  • Power: 120 V
  • Refrigerant: R-410A
  • Connections: round ABS inlet and outlet, separate fresh air inlet
  • Standards: ETL listed to the UL and CSA safety standards stated on the spec sheet
  • Warranty: 5 years (manufacturer)

AirGreen, from estimate to start-up

AirGreen is a family business that has been selling and installing heating, cooling and air quality systems for more than 15 years. It holds an RBQ licence and has its showroom in Boucherville. For a dehumidifier of this capacity, we take the time to choose the right model, connect it properly and explain the control to you.

To buy and have the Honeywell DR120A3000 dehumidifier installed, contact AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.