FANTECH SHR 150 Air Exchanger Greater Montreal

In stock
159 cfm net1,900 to 3,000 sq ft58% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeLifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 159 cfm net, enough to ventilate 1,900 to 3,000 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 159 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
58%
At −25 °CCode: 54% minimum
63%
At 0 °CMeasured at 101 cfm
Net airflowThe ducts cost it 23 cfm
0.2 in · test bench182 cfm
0.4 in · with ducts159 cfm

$91.75

Electricity per year

Less than a 100 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

94W
Running continuously
823kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 58% at 85 cfm.

Airflow and efficiency: manufacturer's published data. Cost: 94 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

HungHangs with the supplied kit; wall bracket optional

The SHR 150 is normally hung with the supplied kit, using bolts at the four top corners. A wall bracket is available as an option if the unit must be fixed to a wall instead.

Switch3-position switch: low, standby, medium

An external three-position rocker switch runs the unit continuously at low or medium speed, with no wall control. Fantech's ECO-Touch, EDF7, RTS2, RTS5 and MDEH1 controls are optional.

58%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 85 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.

−23 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 182 to 159 cfm.

94 WMeasured at the airflow it actually runs at

Its 63% at 0 °C is measured at 101 cfm, the continuous airflow of a typical home. At that setting it draws 94 W, or about 823 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

6 inWhat it needs on site

6 in ducts, side connection and a condensate drain. It weighs 46 lb, and it needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Side connectionSide ports
Condensate drainRequired
46 lbUnit weight
23.75 × 17.25 × 16.25 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
182 cfm
Net airflow at 0.4 in. w.g.
159 cfm
SRE at 0 °C (101 cfm)
63%
SRE at −25 °C (85 cfm)
58%
ASE at 0 °C
71%
Power draw
94 W
Efficacy
1.1 cfm/W
Type
HRV
Connection
Side ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic panel filters (8.5 × 15 in)
Dimensions (L × D × H)
23.75 × 17.25 × 16.25 in
Weight
46 lb
Power supply
120 V
Warranty — core
Lifetime
Warranty — motors
7 years
Warranty — parts
5 years

Airflow and efficiency: manufacturer's published data. Annual consumption calculated at 94 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Introducing the Fantech SHR 150 Heat Recovery Ventilator

Introduction

When it comes to keeping your indoor environment healthy, comfortable and energy efficient, an air exchanger like the Fantech SHR 150 is essential. Based in Montreal, AirGreen is an HVAC (heating, ventilation and air conditioning) company specializing in the sale and installation of air exchangers. Our flagship product is the Fantech SHR 150, a heat recovery ventilator (HRV) designed to improve air quality in any home.

How the Fantech SHR 150 Works

The Fantech SHR 150 is designed to bring a continuous flow of fresh air into a home while exhausting an equal volume of stale air. In winter, the incoming fresh air is tempered by heat transferred from the outgoing air, which saves energy. In summer, if the home has an air cooling system, the incoming air is pre-cooled. The SHR 150 is equipped with automatic defrost mechanisms, which means you can use your HRV all year round.

Technical Features

Fans

The SHR 150 is equipped with two factory-balanced fans with backward-curved blades. The motors have sealed, permanently lubricated ball bearings for long life and maintenance-free operation.

Heat Recovery Core

The aluminum heat recovery core is covered by a limited lifetime warranty. The core measures 9 in. x 9 in. (229 x 229 mm) with a depth of 15 in. (380 mm). Fantech heat exchangers are designed and built to withstand extreme temperature variations.

Defrost

A preset defrost sequence activates at an outdoor temperature of 23 °F (−5 °C) and below. During the defrost sequence, the supply fan stops and the exhaust fan switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation and continues the cycle.

Maintenance

The core, filters, fans and drain pan are easy to reach through a latched door. The core slides easily on Fantech's new easy-slide guides. A clearance of 17 in. (432 mm) is recommended for core removal.

Design and Installation

Casing

The Fantech SHR 150 has a 22-gauge galvanized steel casing with a corrosion-resistant pre-painted steel door.

Insulation

The casing is fully insulated with 1 in. (25 mm) high-density expanded polystyrene.

Filters

The SHR 150 has two washable electrostatic panel-type air filters, 8.5 in. (216 mm) x 15 in. (380 mm) x 0.125 in. (3 mm).

Controls

The Fantech SHR 150 has an external three-position rocker switch (Low/Off/Medium) that provides continuous ventilation. Fantech offers a variety of external controls.

Installation

The unit is usually suspended using the installation kit supplied with the unit. Mounting bolts are provided on the four top corners of the unit. An optional wall bracket is also available.

Warranty

The Fantech SHR 150 comes with a limited lifetime warranty on the aluminum core, 7 years on the motors and 5 years on parts.

Features

  • Compact design
  • Backward-curved blade fans
  • Electrostatic filters (washable)
  • Aluminum heat recovery core
  • Removable screw terminal for easy connection
  • Lightweight, at 48 lb (21.55 kg)
  • Multi-speed operation

Standards and Compliance

The Fantech SHR 150 meets all relevant standards, including the UL 1812 requirements governing the construction and installation of heat recovery ventilators, the CSA C22.2 No. 113 standards for fans, and the CSA F326 requirements governing the installation of heat recovery ventilators. The technical data was obtained from published test results under the CSA C439 standards.

Conclusion

The Fantech SHR 150 is an efficient, economical and reliable heat recovery ventilator that improves air quality while ensuring energy savings. Whether you are a homeowner looking for a way to improve the air quality in your home or an industry professional looking for a reliable, quality solution for your clients, the Fantech SHR 150 is a choice worth considering. Contact us at AirGreen to learn more about this product and how it can meet your indoor air quality needs.