FANTECH VHR 70R ES Air Exchanger Greater Montreal

In stock
70 cfm net800 to 1,300 sq ft62% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Lifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 70 cfm net, enough to ventilate 800 to 1,300 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 70 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
62%
At −25 °CCode: 54% minimum
65%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 13 cfm
0.2 in · test bench83 cfm
0.4 in · with ducts70 cfm

$34.16

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

35W
Running continuously
307kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 62% at 44 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 35 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

24 inFits a 24 in closet or above the water heater

Fantech designed this small HRV for condos and apartments needing up to 70 cfm of continuous ventilation. With top ports and the EZ-Mount wall bracket, it installs in a 24 in closet or above the water heater.

5 in ovalOval collars with a built-in balancing damper

The 5 in oval plastic collars include a balancing damper and airflow measurement ports, so the installer can measure and set airflows right at the unit, within the published 40 to 80 cfm range.

62%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 44 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, the problem is almost always too much humidity, not too little.

2505155Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−13 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 83 to 70 cfm. Most spec sheets show only the first number, precisely because it looks better.

35 WMeasured at the airflow it actually runs at

Its 65% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 35 W, or about 307 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

5 inWhat it needs on site

5 in (oval) ducts, top connection and a condensate drain. It weighs 33 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2505155. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

5 in (oval) ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
33 lbUnit weight
21.5 × 10.25 × 15.63 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
83 cfm
Net airflow at 0.4 in. w.g.
70 cfm
SRE at 0 °C (42 cfm)
65%
SRE at −25 °C (44 cfm)
62%
Power draw
35 W
Efficacy
1.2 cfm/W
Type
HRV
Connection
Top ports
Duct collars
5 in (oval)
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable electrostatic panel filters (8.5 × 8 in)
Dimensions (L × D × H)
21.5 × 10.25 × 15.63 in
Weight
33 lb
Power supply
120 V
HVI certification (Section III)
2505155
Warranty — core
Lifetime
Warranty — motors
7 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505155). Annual consumption calculated at 35 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Introducing the FANTECH VHR 70R ES: The Revolutionary Air Exchanger by AirGreen

At AirGreen, we're proud to introduce the Fantech VHR 70R ES, our most compact and energy-efficient air exchanger, which has achieved ENERGY STAR® certification. Designed to provide effective and quality ventilation in your home, this device is the perfect solution for those seeking optimal energy efficiency and superior performance.

Quality Ventilation for Your Home

The Fantech VHR 70R ES is specially designed for small residential and multi-residential applications, such as condominiums and apartments requiring up to 70 CFM of continuous main ventilation. It features a compact and flexible design with integrated 5" oval duct connectors, allowing for easy installation in small spaces like 24" closets or above the water heater. It's an ideal choice for residential use, serving 1-3 bedroom homes effectively.

Exceptional Performance

The Fantech VHR 70R ES delivers an air flow of up to 70 cfm at 0.4" w.g. Thanks to its backward-curved blade fans, perfectly factory balanced, this air exchanger ensures smooth and quiet ventilation while being extremely energy-efficient. It is powered by a 120V/Phase AC motor that consumes only 60W, thus offering an excellent performance-to-energy consumption ratio.

Innovative and Durable Design

The VHR 70R ES features a superior duct connection design that integrates seamlessly into confined spaces. Its 22-gauge galvanized steel casing, with a corrosion-resistant pre-painted steel door, gives it exceptional durability and robustness. Moreover, its lightweight design, weighing only 33 lbs (14.75 kg), significantly facilitates its installation.

Aluminum Heat Recovery Core

At the heart of the Fantech VHR 70R ES is an aluminum heat recovery core, covered by a lifetime limited warranty. This core, measuring 8.5" x 8.5" with a depth of 8", is designed to withstand extreme temperature variations. It recovers energy from the extracted air and uses it to temper the incoming fresh air, thus optimizing the energy required to pre-cool or pre-heat the introduced air.

Winterguard™ Defrosting

The VHR 70R ES incorporates a unique and quiet internal recirculation defrosting that does not depressurize the house during the defrost cycle. A preset defrost sequence is activated when the outside temperature drops below 23° F (-5° C) and automatically adjusts according to operating conditions. The fan speed is also automatically adjusted to ensure a smooth and quiet transition between Ventilation & Defrost mode.

Ease of Service

The core, filters, fans, drain pan, and electrical panel can easily be accessed from the access panel. The core is easily removed with only a 10" (250 mm) clearance.

Duct Connections

The 5" (125 mm) oval plastic duct connections are integrated with an air flow balancer and air flow measurement ports.

Controls

The VHR 70R ES air exchanger is equipped with a three-position external switch (Reduced/Stand By/Normal) that offers continuous ventilation. Fantech offers a variety of external controls for optimal ventilation management.

Warranty

Purchasing this air exchanger is a long-term investment. To guarantee your peace of mind, we offer a limited lifetime warranty on the aluminum core, a 7-year warranty on motors, and a 5-year warranty on parts.

Conclusion

In summary, the Fantech VHR 70R ES is a compact, energy-efficient, and high-performing device that ensures balanced air exchange for a healthy indoor climate. Whether you're the owner of a small house or a large apartment, this air exchanger is the ideal solution for ensuring optimal air quality throughout the year. With its advanced features and quality construction, the VHR 70R ES is a valuable addition to any home.