GreenTek PREMIER PRS 2.0E Air Exchanger Greater Montreal

In stock
201 cfm net2,400 to 3,800 sq ft60% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 201 cfm net, enough to ventilate 2,400 to 3,800 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 201 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
60%
At −25 °CCode: 54% minimum
75%
At 0 °CCertified at 66 cfm
Net airflowThe ducts cost it 32 cfm
0.2 in · test bench233 cfm
0.4 in · with ducts201 cfm

$50.75

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

52W
Running continuously
456kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 66 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 52 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

FurnaceBuilt-in interlock relay for the furnace

The terminal block includes a relay (NO, C, NC): in ventilation mode NO-C closes, which can start the furnace blower when fresh air travels through its ducts. Wire only the furnace's low-voltage blower circuit to it, never a 120 V circuit.

MERV 13MERV 8 and MERV 13 filter packs listed

The PREMIER manual lists 2-packs of MERV 8 (463945) and MERV 13 (463946) filters for the PRS 2.0E, replacing the original MERV 3 electrostatic filters when finer filtration is wanted.

60%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005259Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−32 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 233 to 201 cfm. Most spec sheets show only the first number, precisely because it looks better.

52 WMeasured at the airflow it actually runs at

Its 75% at 0 °C is certified at 66 cfm, the continuous airflow of a typical home. At that setting it draws 52 W, or about 456 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

6 inWhat it needs on site

6 in ducts, side connection. It needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005259. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

6 in ductsCollar diameter
Side connectionSide ports
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
233 cfm
Net airflow at 0.4 in. w.g.
201 cfm
SRE at 0 °C (66 cfm)
75%
SRE at −25 °C (66 cfm)
60%
Power draw
52 W
Efficacy
1.2 cfm/W
Type
ERV
Connection
Side ports
Duct collars
6 in
Defrost cycle
Exhaust only (supply fan off)
Filters
MERV 3 electrostatic filter kit (463940)
Power supply
120 V
HVI certification (Section III)
2005259
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005259). Annual consumption calculated at 52 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

GreenTek PREMIER PRS 1.5ESmaller1,900 to 3,000 sq ft161 cfm
GreenTek PREMIER PRS 2.0EYou are here2,400 to 3,800 sq ft201 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Ventilation of the Future: The Greentek Premier PRS 2.0E

Engineered by the pioneers at Greentek, the Premier PRS 2.0E showcases a futuristic approach to energy recovery ventilation (ERV). Combining top-notch efficiency with a user-centric design, this product promises to keep your home fresh while enhancing your comfort levels.

Specifications of the Greentek Premier PRS 2.0E

  • Manufacturer: Greentek
  • Model Series: Premier Series
  • Model Description: Premier PRS 2.0E
  • Part Number: 463923
  • Ventilation Performance: 201 CFM @0.4 in. wg
  • Fantech Equivalent Model: ATMO 200E 463891
  • Core Type: Energy Recovery Ventilator (ERV)
  • Defrost Type: FAN Defrost
  • Motor Type: PSC
  • Heat Recovery Rate (SRE): 75%
  • Moisture Transfer rate: 60%
  • Wall Controller Included: No

The Premier PRS 2.0E offers a continuous supply of fresh, filtered air at a flow rate of 201 CFM while expelling an equal amount of stale air. This ERV recovers up to 75% of the heat in the extracted air and uses it to condition the incoming fresh air.

Cutting-Edge Features

  • Round Metal Duct Connections: Features round metal duct connections with rubberized duct seals for robust and airtight connections.
  • Plastic Collar Shrouds: Comes with plastic collar shrouds that feature integrated backdraft prevention for optimal airflow management.
  • Removable Screw Terminal: Allows easy and accessible connections with external access, ensuring smooth installation and maintenance.
  • Top Port Design: Innovative top port design to fit into tight spaces, making it versatile for various home architectures.
  • Inclusive Hanging Chains: Comes with hanging chains for convenient installation. Optional wall mounting brackets are sold separately for added flexibility.
  • Counterflow Heat Recovery Core: Efficient counterflow heat recovery core with a Sensible Recovery Efficiency (SRE) of up to 75%, ensuring maximum heat conservation.
  • External Electrical Box: Features an external electrical box with easy connectors for streamlined and hassle-free wiring.
  • Multiple-Speed Operation: Offers a multi-speed operation to cater to the varying ventilation needs of your home.
  • Internal Recirculation Defrost: Equipped with an internal recirculation defrost mechanism that gets activated at low temperatures, ensuring efficient operation even during winter.
  • Injected Foam Cabinet: Features an injected foam cabinet that is UL-rated and designed for improved aerodynamics, better insulation, and soundproofing.
  • Optional MERV 8 & MERV 13 Filters: Comes with standard MERV3 filters with the option to upgrade to MERV 8 or MERV 13 filters for enhanced air filtration.

The Premier PRS 2.0E is built for high static pressure applications that require high efficiency. It comes with an automatic defrost mechanism that activates when the outdoor air temperature drops to 23°F (-5°C) or below. During the defrost cycle, the supply air fan shuts down, and the exhaust air fan switches to high speed to ensure the unit's effectiveness.

This ERV showcases an efficient cross-flow exchanger, integrated air balancing taps, easy-connect ports, and duct ports with plastic collar shrouds, ensuring simple and quick installation. An investment in the Premier PRS 2.0E translates to an upgrade in your home's air quality, efficiency, and overall comfort.