GreenTek PROFILE P 1.2ED-EC Air Exchanger Greater Montreal
Is it the right size for your home?
It delivers 129 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$22.45
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 61% at 51 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMEC motors: 23 W at 51 cfm instead of 55 W
Per HVI it draws 23 W at 51 cfm, versus 55 W for the PROFILE 1.2E-D at the same airflow, in the same cabinet with the same built-in shut-off damper. Running continuously, that is less than half the electricity.
ENERGY STAROn NRCan's ENERGY STAR list
The PROFILE 1.2E-D-EC is on Natural Resources Canada's ENERGY STAR list (checked November 23, 2026). In the PROFILE series, Greentek limits ENERGY STAR certification to EC-motor models; the PROFILE 1.2E and 1.2E-D are not certified.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005262Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 129 cfm. Most spec sheets show only the first number, precisely because it looks better.
23 WMeasured at the airflow it actually runs at
Its 77% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 129 cfm
- SRE at 0 °C (51 cfm)
- 77%
- SRE at −25 °C (51 cfm)
- 61%
- Power draw
- 23 W
- Efficacy
- 2.2 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005262
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005262). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The EC-motor ceiling ERV, for continuous ventilation on little power
The PROFILE 1.2E-D-EC uses the ceiling cabinet and built-in shut-off damper of the PROFILE 1.2E-D, with electronically commutated (EC) motors. It is an ERV: it recovers the heat of the stale air and part of its moisture. According to the HVI directory, it delivers 129 cfm net at 0.4 in w.g. (61 L/s at 100 Pa).
An air exchanger runs almost non-stop, twelve months a year: motor power is what weighs on the bill. Like the other PROFILE units, it has 10 in of installed depth and needs no drain. Greentek provides three modes: ECONO, 20 min/h and continuous ventilation.
What sets the PROFILE 1.2E-D-EC apart
EC motors: 23 W instead of 55 W
At the HVI test point of 51 cfm at 0 °C, the 1.2E-D-EC draws 23 W. The 1.2E-D, at the same airflow and in the same cabinet, draws 55. That is less than half for the same fresh air. At −25 °C the gap holds: 24 W versus 55 W. Per Greentek's specification, these are external-rotor EC motors.
77% efficiency at 0 °C
According to HVI, its sensible recovery efficiency reaches 77% at 51 cfm, versus 74% for the PROFILE 1.2E and 1.2E-D at the same airflow. It is the highest of the three PROFILE 1.2 units: less electricity and a little more heat recovered.
Efficiency and power use
According to the HVI directory (Section III, current as of November 18, 2026), the PROFILE 1.2E-D-EC has a sensible recovery efficiency of 77% at 0 °C, measured at 51 cfm, drawing 23 W. The higher the airflow, the lower it goes: at 125 cfm it is down to 64%, at 62 W. At −25 °C, measured at 51 cfm, it is 61% at 24 W. This result exceeds both thresholds in article 9.36.3.9 of the Québec Construction Code, in force since April 17, 2025: 55% below 6,000 degree-days and 60% above.
Installation
- Ducts: four 5 in round metal side ports with rubberized seals
- Damper: built-in shut-off, as on the 1.2E-D
- Drain: no drain required
- Dimensions (L × D × H): 23.16 × 20.75 × 10.06 in
- Weight: 35 lb
- Mounting: supplied metal ceiling bracket; chain kit optional
- Power: 120 V, single phase, 60 Hz, with cord; -HC version permanently connected
Maintenance
It ships with 2 washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in. Greentek's general maintenance page recommends vacuuming them four times a year and replacing them every year. The core is cleaned once a year and must be completely dry before it goes back in. Unplug the unit before any service.
Manufacturer's warranty
Greentek gives a limited warranty of 5 years on the energy recovery core, 7 years on the motors and 5 years on the electrical components. The invoice proves the purchase date: keep it. Improper maintenance or repair voids the warranty.
Financial assistance
Since October 1, 2026, Rénoclimat no longer gives any grant for an air exchanger under its new stream. A file whose pre-work evaluation took place before that date follows the old rules: $500 for a unit listed in Section III of the HVI directory (this model is, no. 2005262), if the EnerGuide rating improves, with the post-work evaluation done by March 31, 2027 at the latest. Hydro-Québec's LogisVert program does not cover air exchangers.
The PROFILE 1.2E-D-EC is on Natural Resources Canada's ENERGY STAR list (checked November 23, 2026).
Installation by AirGreen in Greater Montreal
We assess the ventilation needs of each room on site. We check the ceiling location and its access hatch, the drain (none needed here), the duct path to the outside wall and the electrical supply. After installation, we balance supply and exhaust air before we leave, so the unit runs continuously at the airflow the home needs, and no more. We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.
To compare, see all Greentek air exchangers. For a free estimate, call us at 514 316-2973 or email sales@airgreen.ca.