GreenTek PROFILE P 1.2ED Air Exchanger Greater Montreal

In stock
127 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 55% or 60% minimum
74%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts127 cfm

$53.68

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

55W
Running continuously
482kWh
Per year
3months
Filter cleaning

Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 61% at 51 cfm (HVI).

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

DamperBuilt-in shut-off damper blocks outdoor air

When the unit is not running, its built-in shut-off damper closes so unconditioned outdoor air is not drawn toward the air handler.

MERV 13MERV 8 or MERV 13 filters possible on the supply side

Two washable MERV 3 electrostatic filters come standard. Greentek's CSI specification for the PROFILE 1.2E-D lists optional MERV 8 or MERV 13 filters on the supply side in place of the MERV 3.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005260Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm. Most spec sheets show only the first number, precisely because it looks better.

55 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
35 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
127 cfm
SRE at 0 °C (51 cfm)
74%
SRE at −25 °C (51 cfm)
61%
Power draw
55 W
Efficacy
0.9 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2005260
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005260). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The ceiling ERV with a shut-off damper, for fresh air fed into a central system

The PROFILE 1.2E-D is the PROFILE 1.2E with a built-in shut-off damper. Same ceiling ERV with 10 in of installed depth: it recovers the heat of the stale air and part of its moisture, delivers 127 cfm net at 0.4 in w.g. per HVI (60 L/s at 100 Pa), connects through 5 in side ports and needs no drain.

The damper earns its place when the PROFILE's fresh air is ducted into an air handler: a condo with a central fan coil, for example, or a house heated by a forced-air furnace.

What sets the PROFILE 1.2E-D apart

When the unit stops, the damper closes the outdoor air path

If the PROFILE stops while the central system's blower keeps running, that blower can pull unconditioned outdoor air through the exchanger. Per Greentek, the built-in shut-off damper is there precisely to keep outdoor air from being drawn toward the air handler when the ERV is not running. In January, that is a lot less freezing air in the system's return.

Optional MERV 8 or MERV 13 filters

Two washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in, are included. Greentek's PROFILE specification lists optional MERV 8 or MERV 13 filters on the fresh-air side, in place of the MERV 3. When that fresh air then travels through the whole central system, finer filtration at the intake makes sense.

Efficiency and power use

According to the HVI directory (Section III, current as of November 18, 2026), the PROFILE 1.2E-D has a sensible recovery efficiency of 74% at 0 °C, measured at 51 cfm, drawing 55 W. The higher the airflow, the lower it goes: 64% at 131 cfm, at 104 W. At −25 °C, measured at 51 cfm, it is 61% at 55 W. This result exceeds both thresholds in article 9.36.3.9 of the Québec Construction Code, in force since April 17, 2025: 55% below 6,000 degree-days and 60% above.

Installation

  • Ducts: four 5 in round metal side ports with rubberized seals
  • Damper: built-in shut-off damper, closed when the unit is off
  • Drain: no drain required
  • Dimensions (L × D × H): 23.16 × 20.75 × 10.06 in
  • Weight: 35 lb
  • Mounting: supplied metal ceiling bracket; chain kit optional
  • Power: 120 V, single phase, 60 Hz, with cord; -HC version permanently connected

Maintenance

According to Greentek's general maintenance page, the filters are vacuumed four times a year and replaced every year. The fresh-air filter gets dirty faster. The polymer core, water-washable per Greentek's specification, is cleaned once a year or as needed. Always unplug the unit before servicing it.

Manufacturer's warranty

Greentek gives a limited warranty of 5 years on the energy recovery core, 7 years on the motors and 5 years on the electrical components. Keep the invoice, which sets the purchase date. Improper maintenance or repair voids the warranty.

Financial assistance

Since October 1, 2026, Rénoclimat no longer gives any grant for an air exchanger under its new stream. A file whose pre-work evaluation took place before that date follows the old rules: $500 for a unit listed in Section III of the HVI directory (this model is, no. 2005260), if the EnerGuide rating improves, with the post-work evaluation done by March 31, 2027 at the latest. Hydro-Québec's LogisVert program does not cover air exchangers.

Installation by AirGreen in Greater Montreal

We assess the ventilation needs of each room on site. We then look at how the fresh air will reach the central system, the location, the drain (none needed here), the duct path to the outside wall and the electrical supply. After installation, we balance supply and exhaust air and check that the damper closes when the unit stops, before we leave. We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.

To compare, see all Greentek air exchangers. For a free estimate, call us at 514 316-2973 or email sales@airgreen.ca.