GreenTek SOLACE 2.5H-EC Air Exchanger Greater Montreal

In stock
252 cfm net3,000 to 4,800 sq ft63% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeLifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 252 cfm net, enough to ventilate 3,000 to 4,800 sq ft. Choose your home's living area.

It's the right size.

For a 3,200 to 5,000 sq ft home, about 215 cfm of air needs to be renewed continuously. This unit delivers 252 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
63%
At −25 °CCode: 55% or 60% minimum
82%
At 0 °CCertified at 85 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench267 cfm
0.4 in · with ducts252 cfm

$33.19

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

34W
Running continuously
298kWh
Per year
3months
Filter cleaning

Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 63% at 83 cfm (HVI).

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 34 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

252 cfmHighest airflow in the SOLACE series: 252 cfm

Per HVI it delivers 252 cfm at 0.4 in, versus 203 cfm for the same-size SOLACE 2.0H (27.88 × 15.38 in). Its published balancing range is 120 to 280 cfm.

ECMECM motors: 34 W at 85 cfm

Its two electronically commutated motors draw 34 W at 85 cfm, while the standard-motor SOLACE 2.0H needs 98 W at the same airflow (HVI). In continuous operation, the gap shows on the power bill.

63%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.

DamperIt defrosts with indoor air

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

2505391Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 267 to 252 cfm. Most spec sheets show only the first number, precisely because it looks better.

34 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 85 cfm, the continuous airflow of a typical home. At that setting it draws 34 W, or about 298 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

6 inWhat it needs on site

6 in ducts, top connection. It weighs 58 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
58 lbUnit weight
27.88 × 15.38 × 23 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
267 cfm
Net airflow at 0.4 in. w.g.
252 cfm
SRE at 0 °C (85 cfm)
82%
SRE at −25 °C (83 cfm)
63%
Power draw
34 W
Efficacy
2.5 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable electrostatic panel filters (7.9 × 13.8 in)
Dimensions (L × D × H)
27.88 × 15.38 × 23 in
Weight
58 lb
Power supply
120 V
HVI certification (Section III)
2505391
Warranty — core
Lifetime
Warranty — motors
7 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505391). Annual consumption calculated at 34 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

GreenTek SOLACE 2.0HSmaller2,400 to 3,800 sq ft203 cfm
GreenTek SOLACE 2.5H-ECYou are here3,000 to 4,800 sq ft252 cfm

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

An EC-motor HRV for a large house that needs a lot of air

The SOLACE 2.5H-EC is the heat recovery ventilator (HRV) that moves the most air in Greentek's SOLACE series: 252 cfm net at 0.4 in, per the HVI directory. Vertical, with 6 in round collars on top, it shares the SOLACE 2.0H cabinet.

It is the pick for a large house, or when the ducts are long and you need airflow in reserve. Its spec sheet says nothing about the drain; we check that on site. Internal recirculation defrost starts below −5 °C; according to Greentek, recirculation defrost does not put the house under negative pressure.

What sets the SOLACE 2.5H-EC apart

252 cfm, the highest airflow in the SOLACE series

In the same 27.88 × 15.38 in cabinet, the SOLACE 2.0H gives 203 cfm at 0.4 in; the 2.5H-EC gives 252. Its published balancing range is 120 to 280 cfm, like the 2.0H's, and it is balanced with the STS 2.0 control Greentek requires.

34 W at 85 cfm, versus 98 W for the 2.0H

At the same HVI test point of 85 cfm at 0 °C, the 2.5H-EC draws 34 W and the standard-motor 2.0H draws 98 W. Running continuously at that airflow, the gap repeats every hour. At full speed, though, EC motors draw power too: HVI lists 246 W at 233 cfm.

Efficiency and power use

According to the HVI directory (Section III, current as of November 18, 2026), the sensible recovery efficiency of the SOLACE 2.5H-EC is 82% at 0 °C, at 85 cfm and 34 W. At −25 °C, it is 63% at 83 cfm, drawing 65 W. This result exceeds both thresholds of article 9.36.3.9 of the Quebec Construction Code, in force since April 17, 2025: 55% below 6,000 degree-days and 60% above.

It recovers less when pushed: at 0 °C, its efficiency goes from 82% at 85 cfm to 72% at 233 cfm. In deep cold, the 2.0H does a little better (67% at 87 cfm); the 2.5H-EC makes up for it on power use.

Installation

  • Ducts: 6 in round collars, on top; vertical unit.
  • Drain: nothing on the spec sheet; checked during the visit.
  • Dimensions (W × D × H): 27.88 × 15.38 × 23 in.
  • Weight: 58 lb, core included.
  • Mounting: on the supplied wall bracket, or hung from the ceiling on chains.
  • Power: 120 V, 6.4 A, plugged in with a 3 ft cord (3-prong plug).

Maintenance

The 2.5H-EC ships with 2 washable electrostatic panel filters (7.9 × 13.8 in); an optional MERV 8 or MERV 13 filter can be added on the fresh-air supply. To remove the core, leave 16 in free in front of the unit. Always unplug the unit before servicing it.

Manufacturer's warranty

The counterflow core is covered for life by Greentek's limited warranty; the EC motors for 7 years; electrical components for 5 years. According to Greentek, the warranty does not cover damage caused by improper wiring, improper installation or incorrect voltage.

Financial assistance

Since October 1, 2026, Rénoclimat no longer provides assistance for an air exchanger under its new stream. A file whose pre-work evaluation took place before that date follows the old rules: $500 for a unit listed in Section III of the HVI directory (this model is, no. 2505391), if the EnerGuide rating improves, with the post-work evaluation completed by March 31, 2027 at the latest. Hydro-Québec's LogisVert program does not cover air exchangers.

The SOLACE 2.5H-EC is on Natural Resources Canada's ENERGY STAR list (checked November 23, 2026).

Installation by AirGreen in Greater Montreal

We assess the ventilation needs of each room on site. For a unit this size, we look closely at the duct runs, the location and its 16 in of clearance, the drain and the electrical supply. If your need stays below the 120 cfm bottom of its range, a smaller model will fit better.

Once the installation is done, we balance supply and exhaust on the STS 2.0 control before we leave. We work in Montreal, Laval and Longueuil, as well as on the South Shore and the North Shore. To compare it with the 2.0H, see all Greentek air exchangers.

For a free estimate, call us at 514 316-2973 or email sales@airgreen.ca.