Lifebreath METRO 120 ERVD Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 123 cfm net, enough to ventilate 1,400 to 2,300 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 123 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$61.49
Electricity per year
Less than a 100 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 57% at 57 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 63 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
−25 °CERV certified for cold weather to −25 °C
Unlike the METRO 120 ERV, which has no −25 °C rating, this “D” version carries the HVI cold-weather certification at −25 °C and still needs no drain.
MirrorMirrored METRO-120ERVD-M version available
If the duct layout calls for it, Lifebreath offers a version with the airflow paths reversed (METRO-120ERVD-M) and a hardwired configuration, so the orientation can suit the installation.
57%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 57 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005105Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−8 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 131 to 123 cfm. Most spec sheets show only the first number, precisely because it looks better.
63 WMeasured at the airflow it actually runs at
Its 72% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 63 W, or about 552 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 37 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 131 cfm
- Net airflow at 0.4 in. w.g.
- 123 cfm
- SRE at 0 °C (49 cfm)
- 72%
- SRE at −25 °C (57 cfm)
- 57%
- ASE at 0 °C
- 81%
- Power draw
- 63 W
- Efficacy
- 0.8 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 25.75 × 19.38 × 9.75 in
- Weight
- 37 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005105
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005105). Annual consumption calculated at 63 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Lifebreath METRO 120 ERVD: a slim ERV certified for cold weather at −25°C
The Lifebreath METRO 120 ERVD, which we install at AirGreen, is an energy recovery ventilator (ERV) that its spec sheet describes as cold weather certified, at −25°C. Like the other METRO 120 units, it is aimed at high-rise condos, apartments and townhomes with little mechanical space: 25 3/4 in. by 19 3/8 in., at 9 3/4 in. high and 37 lb.
What Lifebreath Built Into It
Here are its components, as Lifebreath describes them:
- Total recovery core: this cross-flow core passes not only heat but also water vapour from the stale air to the fresh air. It comes out easily for cleaning or service.
- Blowers: each airstream has its own centrifugal blower, with several speeds; the high speed is selected with DIP switches on the circuit board.
- Recirculating damper defrost: triggered by a temperature sensor, it defrosts the core by recirculating house air, with no drain.
- Filters: two washable MERV 6 filters, one on the stale-air side and one on the fresh-air side; a MERV 13 set is available as an option (65-195-6R).
- Mounting: brackets are supplied for ceiling installation, and the spec sheet recommends 25 in. (635 mm) of clearance at the front for service.
- Cabinet: 22-gauge prepainted galvanized steel for corrosion resistance, with insulation that prevents condensation on the outside; all ducts connect to 5 in. (125 mm) round collars.
- Versions: Lifebreath also offers it in a mirrored version (METRO-120ERVD-M) and in a hardwired configuration.
HVI-Certified Performance
The HVI directory lists the METRO 120 ERVD under number 2005105. At 0°C, HVI rates it at 72% sensible recovery at 49 cfm (23 L/s) for 63 W, then 71% at 64 cfm and 66% at 95 cfm. At −25°C and 57 cfm (27 L/s), its sensible recovery efficiency is 57% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. It thus clears the 55% threshold, but not the 60% one. In cooling, at 35°C and 49 cfm, HVI gives it 44% total recovery efficiency. It delivers 131 cfm net at 0.2 in. and 123 cfm at 0.4 in. of static pressure.
At the 49 cfm test airflow, its 63 W come to about 552 kWh a year in continuous operation, or about $61 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Controls and Timers
The main control is installed on the wall, in a central room of the dwelling; Lifebreath specifies 3-conductor wire of at least 20 gauge, up to 100 ft long. Three accessories start high speed on demand:
- 99-DET01: a wired, 3-wire timer that switches on high speed for 20, 40 or 60 minutes.
- 99-DET02: its wireless version, which pairs with the main control and reaches about 40 ft (12 m) with no obstructions, according to Lifebreath.
- 99-RX02: a repeater plugged into a 120 V outlet, which extends the range of the 99-DET02 and communicates wirelessly with it and with the main control.
Manufacturer's Warranty
Lifebreath's warranty covers the ERV core for 5 years and replacement parts for 5 years.
Installation by AirGreen
We assess the dwelling's ventilation needs on site (bedrooms, bathrooms, kitchen, basement if applicable). If its 123 cfm net at 0.4 in. is not enough, or if your project must reach 60% at −25°C, we present another Lifebreath model.
The METRO 120 ERVD goes on the ceiling, in a heated space; Lifebreath advises against the attic and reserves wall mounting for its XTR models. With no drain, it needs no trap or condensate pump. It plugs into a 120 V outlet dedicated to it, with no extension cord, and Lifebreath recommends a separate 15 A circuit for it.
Lifebreath considers it factory balanced: as long as the static pressure difference between the duct supplying the house and the one exhausting stale air does not exceed 0.3 in., its two airflows stay within 10% of each other. That is what we check at start-up.
For your free quote, reach us at 514 316-2973 or sales@airgreen.ca: we will call you back. Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120 ERVD in Montreal, Laval, Longueuil, the North Shore and the South Shore.
