Lifebreath METRO 120D HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 125 cfm net, enough to ventilate 1,400 to 2,300 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 125 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$64.42
Electricity per year
Less than a 100 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 61% at 66 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 66 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
9.75 inOnly 9.75 in high, made for dropped ceilings
Built for condos, apartments and townhomes with little mechanical space, it fits in a bulkhead or dropped ceiling. Allow 1 more inch for the drain cup. Along with the other METRO 120 HRVs, it is the slimmest Lifebreath HRV in our catalogue.
50–130Operating range of 50 to 130 cfm
The unit operates between 50 and 130 cfm and offers DIP-selectable high speeds, so the maximum airflow can be matched to the dwelling.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505110Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−8 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 133 to 125 cfm. Most spec sheets show only the first number, precisely because it looks better.
66 WMeasured at the airflow it actually runs at
Its 68% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 66 W, or about 578 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection and a condensate drain. It weighs 37 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 133 cfm
- Net airflow at 0.4 in. w.g.
- 125 cfm
- SRE at 0 °C (64 cfm)
- 68%
- SRE at −25 °C (66 cfm)
- 61%
- ASE at 0 °C
- 75%
- Power draw
- 66 W
- Efficacy
- 1.0 cfm/W
- Type
- HRV
- Connection
- Side ports
- Duct collars
- 5 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 25.75 × 19.38 × 9.75 in
- Weight
- 37 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505110
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505110). Annual consumption calculated at 66 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Lifebreath METRO 120D: a 9 3/4 in. high HRV for tight mechanical spaces
Lifebreath designed the METRO 120D, a heat recovery ventilator (HRV), for high-rise condos, apartments and townhomes with little mechanical space; AirGreen installs it. Its cabinet is only 9 3/4 in. (248 mm) high, plus 1 in. for the drain cup; its other two sides measure 25 3/4 in. and 19 3/8 in., and it weighs 37 lb.
Counter-Flow Aluminum HEX Core
In its aluminum HEX core, the stale air and the fresh air flow in opposite directions; the heat of the outgoing air is thus passed to the incoming air. The core comes out of the unit easily for cleaning or service, as does the motor and electronics assembly, which is also removable.
Blowers and Speeds
An independent centrifugal blower, with several speeds, moves each of the two airstreams. According to Lifebreath, its operating range runs from 50 to 130 cfm; the DIP switches on the circuit board are used to set the high speed to suit the dwelling.
Filtration
Washable MERV 6 filters equip both the stale-air side and the fresh-air side. MERV 13 filters (part 65-195-6R) are ordered separately, in a set of four, and go on the fresh-air side only; Lifebreath requires the airflows to be rebalanced after they are first installed.
Ceiling Mounting
The METRO 120D mounts on the ceiling: at Lifebreath, only the XTR models can be wall mounted. Four mounting brackets come with the unit, and Lifebreath advises isolating them from the mounting surface to minimize vibration. For service, the spec sheet recommends 25 in. (635 mm) of clearance in front of the unit.
Recirculating Damper Defrost
Its intelligent recirculating damper defrost system kicks in when the outdoor temperature drops below −3°C. Lifebreath publishes the cycle: at −3°C, 3 minutes of defrost for 25 minutes of ventilation; at −20°C, 4.5 minutes for 17; at −35°C, 7 minutes for 15.
Cabinet, Collars and Drain
The cabinet, made of 22-gauge prepainted galvanized steel, resists corrosion, and its insulation prevents condensation on its outer faces. The four duct connections are 5 in. (125 mm) round collars. The multi-position cup drain comes with the unit.
Controls
The main control mounts on the wall, in a central spot in the dwelling, and connects with three wires of at least 20 gauge, over a maximum length of 100 ft. Depending on the Lifebreath control you choose, you get:
- Five fan speeds with the 99-DXPL03, which also has an electronic dehumidistat, set anywhere from 25% to 60% relative humidity.
- Two speeds, low and high, with the 99-BC02 and 99-BC04 controls.
- Continuous low speed with the 99-BC03, which also offers continuous recirculation, a mode Lifebreath reserves for damper-defrost units like this one.
- A back-lit LCD screen on the 99-DXPL03, which displays indoor humidity.
- Continuous ventilation, offered among the 99-DXPL03's modes.
HVI-Certified Performance
Listed in the HVI directory under number 2505110, the METRO 120D achieves, at 0°C and an airflow of 64 cfm (30 L/s), 68% sensible recovery for a power draw of 66 W. At −25°C and 66 cfm (31 L/s), its sensible recovery efficiency is 61% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. The METRO 120D therefore meets both thresholds. Its net airflow reaches 133 cfm at 0.2 in. of static pressure, and 125 cfm at 0.4 in.
Run continuously at its 64 cfm test airflow, it uses about 578 kWh a year, or roughly $64 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Warranty
Lifebreath's warranty covers the METRO 120D HRV core for life and replacement parts for 5 years.
Installation by AirGreen
Before recommending the METRO 120D, we assess the dwelling's ventilation needs on site (bedrooms, bathrooms, kitchen, basement if there is one). When its 125 cfm net at 0.4 in. is not enough for them, we present a more powerful Lifebreath model.
The unit must be in a heated space; Lifebreath advises against the attic. For the drain, a single 1/2 in. hose connects to the spout, which we seal to the bottom of the cabinet with silicone; the trap and hose stay below the bottom of the door, with a downward pitch of 1/4 in. per foot away from the unit, and the water goes to a nearby drain or a condensate pump, protected from freezing. The unit plugs directly into a dedicated 120 V outlet, with no extension cord, and we check that outlet's polarity; Lifebreath recommends a separate 15 A circuit and also offers a hardwired configuration.
At start-up, we check the balance between the two airflows. Lifebreath considers the METRO 120D factory balanced: as long as the static pressures of the supply and exhaust ducts stay within 0.3 in. of each other, its two airflows remain within 10% of each other.
For a free quote, call 514 316-2973 or write to us at sales@airgreen.ca: we will call you back. Our team installs the METRO 120D in Montreal, Laval, Longueuil, the North Shore and the South Shore, under AirGreen's RBQ licence 5645-9605-01.