vänEE V230H75RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V230H75RT
225 cfm net2,600 to 4,200 sq ft67% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 10 years
01 · Your home

Is it the right size for your home?

It delivers 225 cfm net, enough to ventilate 2,600 to 4,200 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 225 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
67%
At −25 °CCode: 54% minimum
78%
At 0 °CCertified at 66 cfm
Net airflowThe ducts cost it 6 cfm
0.2 in · test bench231 cfm
0.4 in · with ducts225 cfm

$24.40

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

25W
Running continuously
219kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 67% at 81 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 25 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

231 cfmHighest airflow in the AI range: 65 to 231 cfm

With 231 cfm at 0.2 in and 225 cfm at 0.4 in, it shares with its V230H75RS twin the highest airflow of the vänEE AI models. The V180H75RT, in the same cabinet, tops out at 199 cfm.

6 to 8 inPlan 8 in ducts for long runs

The guide spells it out: once the required airflow exceeds 200 cfm and the duct run is long or has many elbows, 8 in ducts are the better choice. 6-to-8 in transitions go on the ports, held with duct tape only.

67%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 81 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, the problem is almost always too much humidity, not too little.

2505223Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−6 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 231 to 225 cfm. Most spec sheets show only the first number, precisely because it looks better.

25 WMeasured at the airflow it actually runs at

Its 78% at 0 °C is certified at 66 cfm, the continuous airflow of a typical home. At that setting it draws 25 W, or about 219 kWh a year.

10 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years. We register the warranty in your name at commissioning.

6 inWhat it needs on site

6 in ducts, top connection and a condensate drain. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2505223. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
47 lbUnit weight
24.81 × 21 × 21.69 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
231 cfm
Net airflow at 0.4 in. w.g.
225 cfm
SRE at 0 °C (66 cfm)
78%
SRE at −25 °C (81 cfm)
67%
ASE at 0 °C
82%
Power draw
25 W
Efficacy
2.3 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter + washable exhaust filter (included); optional MERV 13 (V24300)
Dimensions (L × D × H)
24.81 × 21 × 21.69 in
Weight
47 lb
Power supply
120 V
HVI certification (Section III)
2505223
Warranty — core
10 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505223). Annual consumption calculated at 25 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The Vanguard of Indoor Air Quality - vänEE V230H75RT AI Series HRV

Elevating Homes in Montreal and Beyond with vänEE AI Series HRV

The pursuit of pristine indoor air quality has led many to the threshold of technological advancement where solutions must not only be effective but also intuitive, energy-efficient, and adaptable. In the bustling localities of Montreal, Laval, Longueuil, and the encompassing North and South Shores, the need for superior air exchange solutions has never been more pronounced. AirGreen, as a standard-bearer in the HVAC industry, presents the vänEE AI Series HRV—a marvel in the realm of home ventilation systems.

The Genesis of Fresh Air with VIRTUO™ Technology

In the depths of a Montreal winter or during the peak of a humid summer, the vänEE AI Series HRV emerges as the beacon of balance, ushering in an era of ambient, filtered outdoor air while dispelling the stale, oppressive indoor atmosphere. The cornerstone of this transformative experience is the VIRTUO™ technology, which is akin to having a silent, discerning maestro conducting the symphony of fresh air in your dwelling. With this advanced auto-balancing feature, the complexity of installation dissipates like morning fog, offering an unprecedented ease that saves up to 20 precious minutes for installers.

The Heart of Efficiency: HRV Core Performance

Envision a system so robust it delivers 231 CFM (cubic feet per minute) of air flow with a Sensible Recovery Efficiency (SRE) of 78%. This is not merely an aspiration but the reality of the vänEE AI Series HRV. Such efficiency is a testament to the dedicated engineering that ensures your home is enveloped in a cocoon of comfort, with energy recovery effectiveness certified even at the daunting temperature of -25°C.

Architectural Versatility: Universal Installation

Whether suspended with included chains or mounted against a wall with universal brackets, the vänEE AI Series HRV is a chameleon in the world of installations. Top or side ports? The choice is yours, offering a flexibility that accommodates the unique blueprint of each home. The system's universality is a nod to the varied architectural landscapes of Montreal's diverse neighborhoods, from the historic to the modern.

MERV 8 Filter: The Guardian of Air Purity

The vänEE HRV doesn't just trade air; it purifies it. With a MERV 8 filter as its standard bearer, it champions a larger capture area for airborne particulates, raising the bar for air quality. This isn't a disposable accessory but a reusable, washable component, championing environmental consideration alongside economic savvy.

The Allure of User-Friendly Controls

A suite of controls from Advanced Touchscreens to Dehumidistats empowers the homeowner to tailor their indoor climate to their precise preferences. These are not just controls; they are keys to unlock a personalized haven, ensuring that whether you're in the heart of Montreal or the tranquility of the North Shore, your home becomes a sanctuary of curated air quality.

The AirGreen Promise: Professional, Personable, Pioneering

At AirGreen, the installation of a vänEE AI Series HRV is not a transaction; it is an entry into a long-term relationship with clients. With five-year warranty on parts and a ten-year warranty on the core, the commitment to excellence is clear. Certified by ENERGY STAR® and HVI, this HRV system is not just an addition to your home; it's an investment in a lifestyle—a pledge to inhale life with every breath of fresh, invigorating air.

Engaging with the Community: A Service Philosophy

AirGreen's footprint spans across Montreal's vibrant communities, from the artsy alcoves of Laval to the serene streets of Longueuil. Each installation is a tapestry woven into the fabric of these neighborhoods, each service call a conversation with those who call this beautiful area home. It's not just about providing a service; it's about enhancing the lives within the homes and communities served.

Conclusion: A Breath of Fresh Air

The vänEE AI Series HRV is not just another HVAC option; it is a vessel that delivers a breath of fresh air to the residents of Montreal and its surrounding areas. It stands as a testament to what happens when innovation aligns with the needs of the community, and AirGreen is proud to be the conduit for such a transformative experience.