Honeywell HE200C1001/U Humidifier | Installation in Montreal, Laval, Longueuil, South Shore and North Shore

In stock
17 gal/dayAbout 2,000 sq ftBypass
Talk to an HVAC technician · 514 316-2973
Parts warranty 5 years
01 · Your home

Is it the right size for your home?

It puts 17 gallons of water a day into the air (with 49 °C (120 °F) furnace air), enough to humidify about 2,000 sq ft (our estimate). Pick your home's living area.

It's the right size.

For a 900 to 1,500 sq ft house, it's within its range. It will run at part load on ordinary days and keep a reserve for the coldest days.

AirGreen estimate. Honeywell (Resideo) publishes no area in sq ft for this model, only a volume of 20,000 cu ft. For an average-construction home, we count 120 sq ft per gallon a day, the ratio in AprilAire's and Lennox's tables. Older or leaky house: go one size up; our estimator confirms it on site.

02 · Performance

What it does, in numbers

17gal
Output per dayAbout 64 litres of water turned into humidity, at full output.
5years
Parts warrantyRegistered in your name at start-up.

Output: manufacturer's spec (17 gal/day, with 49 °C (120 °F) furnace air).

03 · Good to know

What you should know about this one

Published, verifiable figures, not brochure claims.

17 galWhat it produces per day, at full output

About 64 litres of water turned into humidity in 24 hours. The control runs it to match the humidity you set: it rarely runs flat out, except in very cold weather.

Heat pumpBehind a heat pump, it produces less

It evaporates water from a pad using the heat of the air coming off the furnace. A heat pump blows cooler air, so it evaporates less. With a heat pump, talk to our estimator: depending on the manufacturer, we connect it to hot water or suggest a steam model instead.

BasicManual bypass damper

A TrueEASE 'Basic' model: the bypass damper is opened and closed by hand with the seasons. The HE150 and HE250 have a motorized damper that closes on its own.

CThe Canadian version

C is the Canadian model, shipped with the installation hardware.

9¾ in.The opening it needs

A 9¾ × 12⅝ in. opening in the plenum and a 6 in. bypass duct.

ControlThe control that comes with it

Honeywell H8908 manual humidistat.

UpkeepWhat gets replaced, and when

HC26A1008 pad (or HC26E1004 antimicrobial), replace at least once a year.

35%The humidity to aim for in winter, at most

At −7 °C, no more than 35%; at −18 °C, no more than 25%. Above that, the moisture condenses on the windows. The control adjusts for you if it has an outdoor sensor.

5 yearsThe parts warranty

Parts are covered for 5 years by the manufacturer. We register the warranty in your name at start-up.

04 · Installation

What it needs on site

Bypass ductBetween the supply and return plenums
24 VWater valve, 0.5 A
Cold water supplyConnection to the plumbing
DrainRequired
15 × 10.1 × 17.15 inLength × depth × height

Our estimator checks the ducts, the water supply and the drain before ordering.

Complete spec sheetData and cited sources
Brand
Honeywell
Model
HE200C1001/U
Type
Bypass
Output
17 US gal/day (with 49 °C (120 °F) furnace air)
Control included
Honeywell H8908 manual humidistat.
Upkeep
HC26A1008 pad (or HC26E1004 antimicrobial), replace at least once a year.
Living area
2,000 sq ft (AirGreen estimate)
Dimensions (L × D × H)
15 × 10.1 × 17.15 in
Power supply
24 V
Current
0.5 A
Warranty — parts
5 years

Output, dimensions, electrical data and warranty: Honeywell manufacturer's data. Living area: AirGreen estimate, explained under « Your home ».

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We look at your heating system, the electrical panel, the water supply and the drain, and give you an installed price.

Honeywell HE200C1001/U: the large TrueEASE with a manual damper

The HE200C1001/U is the large version of the TrueEASE Basic. This bypass humidifier delivers 17 gal/day with 49 °C (120 °F) furnace air. It suits a home of about 2,000 sq ft by our estimate.

Larger pad, same simplicity

Compared with the HE100C1001/U, it moves to the large HC26 pad and a taller cabinet, which accounts for the 17 gal/day. It remains a 'Basic' model: the bypass damper is opened and closed by hand with the seasons. If you want a damper that closes on its own, that's the HE250. The control supplied is the Honeywell H8908 manual humidistat. C is the Canadian version, shipped with the installation hardware.

What to plan for

It needs a 9¾ × 12⅝ in. opening in the plenum and a 6 in. bypass duct. The solenoid valve runs on 24 V, at 0.5 A maximum. It needs a water supply and a drain. The HC26A1008 pad, or the HC26E1004 antimicrobial pad, is replaced at least once a year. Its output is rated with 49 °C (120 °F) air: behind a heat pump it produces less, and a steam model is the safer choice.

To get a quote

Call AirGreen at 514 316-2973. Our estimator comes to check the heating system, the electrical panel, the water and the drain, then gives you a quote for the installed unit. We work in Montréal, Laval, Longueuil, the South Shore and the North Shore.