A specific service call for a performance issue
At AirGreen , we were recently called to Sainte-Julie to diagnose a problem with a Zephyr wall-mounted heat pump installed on the rear facade of a single-family red brick home. The customer had noticed for several days that the outdoor unit was no longer starting properly, despite the heating request made to the indoor unit.
This type of situation is common, especially in spring and fall, when defrost cycles and temperature variations can put more strain on the electronic components of a wall-mounted heat pump.
Complete diagnosis: identify the cause of the breakdown
Upon our arrival, our technician performed a visual and electrical inspection of the outdoor unit. The Zephyr heat pump , compact and well installed on a wall bracket, showed a distinctive sign: the fan no longer started, although the compressor attempted to activate briefly before stopping.
The diagnostic steps included:
-
Check the supply voltage and circuit breaker at the electrical panel.
-
Check the electrical connections and the condition of the power cable between the indoor and outdoor unit.
-
Measurement of the fan start capacitor , often the cause of this type of failure.
-
Analysis of the control module (electronic board) using a multimeter and a continuity test.
The cause was quickly identified: the capacitor of the outdoor ventilation motor was defective , preventing the fan from starting and causing the compressor to go into safety mode.
Repair: capacitor replacement and return to service
Once the fault was confirmed, our technician replaced the 3 µF / 450 V capacitor , a part compatible with the Zephyr series. This replacement, although simple, requires careful handling, because a capacitor stores residual voltage that can damage the module if it is not properly discharged.
After installing the new component:
-
We have reset the electronic card ,
-
Tested the complete boot sequence ,
-
And checked the automatic defrost cycle in heating mode.
Result: The fan started up again normally, the compressor resumed stable operation, and the customer immediately noticed a constant flow of warm air inside the residence.
Maintenance tips to extend the life of a Zephyr wall light
Zephyr heat pumps offer good energy efficiency for the Quebec climate, but like any HVAC system, they require annual preventative maintenance . Here are our main recommendations:
-
Cleaning the outdoor condenser at the end of winter to remove dust and leaves.
-
Check electrical connections and terminal tightening once a year.
-
Condensate drain inspection to prevent water leaks in summer.
-
Replace the internal filter every 2 to 3 months depending on use.
-
Noise and defrost monitoring : a fan that no longer turns or excessive frost indicates an anomaly that must be corrected quickly.
AirGreen expertise in Sainte-Julie and throughout the South Shore
This type of intervention perfectly illustrates our approach: precise diagnosis, rapid repair, and courteous service . At AirGreen , we work every week on Zephyr, Fujitsu, Midea, Gree, Sharp and Goodman wall systems throughout Montreal, Laval, Longueuil, the North Shore and the South Shore .
Our mission: to ensure the lasting comfort of our customers, regardless of the make or model of their HVAC system. Thanks to our team of certified technicians , we guarantee long-lasting repairs, genuine parts, and local know-how based on years of experience in the Montreal metropolitan area.
A repair well executed, a satisfied customer
The Sainte-Julie customer thanked us for the prompt response and decided to add his unit to our AirGreen annual maintenance program . This guarantees him a preventive visit before each winter, a complete cleaning and an energy efficiency check.
A simple capacitor failure could have escalated into a costly compressor replacement. Thanks to a quick and methodical intervention , the Zephyr heat pump regained its full efficiency without delay.
AirGreen – Experts in Zephyr wall-mounted heat pump repair in Sainte-Julie and throughout the South Shore.