Only one tall cabinet
The 5-ton (CSH660) stands 1,199 mm tall; the other five sizes we offer, 853.5 mm.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), p. 1COMFORTMAKER // CSH6
What does the CSH6 rating plate say, and where does the unit go?
The values on this page are the ones COMFORTMAKER publishes.
COMFORTMAKER // CSH6
Its name decoded, the space it takes, what it needs from the panel and the refrigerant lines.
The CSH6 is the outdoor unit of COMFORTMAKER’s central heat pumps: six sizes from 2 to 5 tons, a scroll compressor and a factory R-410A charge.
Page updated November 5, 2026
This page answers
What does the CSH6 rating plate say, and where does the unit go?
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.
01 // The tool
Pick the size and the refrigerant line length. The tool decodes each position of the model number from the sheet’s nomenclature, then shows that size’s row.
Size
Refrigerant line length
Sheet nomenclature, p. 2: after the first eight positions come the sales code (A), the engineering revision (1) and two extra digits (01). The tool does not read the serial number: no brand document we cite gives its key. Cooling losses are those the sheet prints for the smallest permitted vapour line of each size. Charge converted to kilograms: AirGreen calculation.
CSH636GKA101
model number decoded
At 7.6 m of refrigerant line, the CSH636 sits at the length where the sheet measures its ratings.
CSH6 sheet (428 41 6400 02, April 25, 2019), pp. 1, 2, 4 and 5.
The COMFORTMAKER shop
Price on quotation, after the on-site assessment.
02 // Did you know
The 5-ton (CSH660) stands 1,199 mm tall; the other five sizes we offer, 853.5 mm.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), p. 1The sheet publishes the cooling loss by refrigerant line length: up to 5% at 30.5 m on the 3-ton, with the smallest permitted vapour line.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), p. 5The sheet’s ratings are measured with 7.6 m of refrigerant line.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), p. 403 // The comparison
At 24,000 BTU/h, the outdoor units of the central system and of the SoftSound® Deluxe wall unit differ in both shape and weight. Sound is not compared: the two documents do not measure it the same way.
| Value | CSH624 | DLCPRAH24 (SoftSound® Deluxe) |
|---|---|---|
| Dimensions W × H × D | 889 × 853.5 × 889 mm | 946 × 810 × 410 mm |
| Weight (basis) | 88.0 kg operating | 65.8 kg net |
| MCA | 15.5 A | 20 A |
| Max fuse | 25 A | 30 A |
| Refrigerant lines, liquid / vapour | 3/8 in / 5/8 in | 3/8 in / 5/8 in |
Same refrigerant line sizes; the CSH624 needs a lower MCA. The weights are not compared: the CSH6 sheet gives an operating weight, the brochure a net weight. DLCPRAH24 values come from the January 2023 COMFORTMAKER brochure.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), pp. 1 and 4; COMFORTMAKER brochure, January 2023, pp. 13 to 18
04 // Published figures
| Value | CSH624 | CSH630 | CSH636 | CSH642 | CSH648 | CSH660 |
|---|---|---|---|---|---|---|
| Nominal size | 2 ton | 2.5 ton | 3 ton | 3.5 ton | 4 ton | 5 ton |
| Nominal capacity | 24,000 BTU/h | 30,000 BTU/h | 36,000 BTU/h | 42,000 BTU/h | 48,000 BTU/h | 60,000 BTU/h |
| Footprint D × W × H | 889 × 889 × 853.5 mm | 889 × 889 × 853.5 mm | 889 × 889 × 853.5 mm | 889 × 889 × 853.5 mm | 889 × 889 × 853.5 mm | 889 × 889 × 1,199 mm |
| Operating weight | 88.0 kg | 103.9 kg | 107.5 kg | 115.7 kg | 117.9 kg | 143.8 kg |
| MCA / max fuse | 15.5 / 25 A | 19.9 / 30 A | 21.6 / 35 A | 27.8 / 40 A | 31.8 / 45 A | 33.9 / 50 A |
| Factory R-410A charge | 7.6 lb | 9.75 lb | 11.2 lb | 9.92 lb | 9.87 lb | 13.0 lb |
| Liquid / vapour | 3/8 / 5/8 in | 3/8 / 3/4 in | 3/8 / 3/4 in | 3/8 / 7/8 in | 3/8 / 7/8 in | 3/8 / 1-1/8 in |
| Standard sound rating | 71 dB(A) | 70 dB(A) | 71 dB(A) | 68 dB(A) | 71 dB(A) | 69 dB(A) |
| Outdoor fan | 3,223 CFM, 1/12 hp | 3,223 CFM, 1/12 hp | 3,223 CFM, 1/12 hp | 3,770 CFM, 1/3 hp | 4,046 CFM, 1/4 hp | 4,400 CFM, 1/3 hp |
| Cooling loss at 15.2 / 24.4 / 30.5 m | 1 / 1 / 2% | 2 / 3 / 3% | 2 / 4 / 5% | 1 / 2 / 2% | 1 / 2 / 3% | 2 / 4 / 5% |
Values as printed; the charge is given in pounds. On the CSH660, the vapour line used for the ratings is 1-1/8 in, for a 7/8 in connection. Cooling loss is for the smallest permitted vapour line of each size. The sound rating follows AHRI Standard 270-08. MCA: minimum circuit ampacity; max fuse: the largest fuse or breaker allowed (printed as MOCP or max fuse depending on the document).
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), pp. 1, 4 and 5
05 // Good to know
Every size has a scroll compressor on isolation grommets, with a compressor sound blanket as standard. The suction line accumulator is factory installed; the bi-flow filter-drier comes with the unit for field installation. Outside, the inlet grille is coated, with 10 mm spacing, and the galvanized steel cabinet gets a baked-on powder coat. Two screws open the control panel.
Below 12.8 °C outdoors, cooling needs the sheet’s low-ambient package: compressor start assist, crankcase heater, evaporator freeze thermostat, isolation relay and low ambient switch, with support feet recommended. Long refrigerant lines also call for the start assist and the crankcase heater, plus a liquid line solenoid under the sheet’s “long line” rules.
06 // Warranty
The sheet refers to the warranty certificate for complete details.
CSH6 Product Specifications, 428 41 6400 02 (April 25, 2019), p. 1
AirGreen // COMFORTMAKER
07 // Questions
Take CSH636GKA101, the form printed on the sheet: C for COMFORTMAKER, S for single-stage communicating, H for heat pump, 6 for the 16 SEER family, 36 for 36,000 BTU/h nominal (3 tons), G for the coil guard grille and K for 208/230 V single phase, 60 Hz. Then come the sales code (A), the engineering revision (1) and two extra digits (01).
Not here. No brand document we cite publishes the serial number key, so we do not read a manufacturing date into it.
The brand publishes no minimum operating temperature. Its expanded tables go down to −19.4 °C (−3 °F; row read, to be confirmed on the sheet). Defrost is controlled by time and temperature. The heat of the whole system with its kit is worked out on the central heat pumps page.
The sheet prints the minimum circuit ampacity (MCA) and the maximum fuse or breaker for each size: from 15.5 A and 25 A on the CSH624 up to 33.9 A and 50 A on the CSH660. The unit runs on 208/230 V single phase, 60 Hz, between 197 V and 253 V. The fan coil and its heater kit have their own supply.
The sheet publishes a standard sound rating of 68 to 71 dB(A) depending on size, tested to AHRI Standard 270-08; the lowest is the CSH642, at 68 dB(A). It is a standard rating: we do not compare it with any other value.
R-410A, factory charged: from 7.6 lb on the CSH624 to 13.0 lb on the CSH660, according to the sheet. The liquid line is 3/8 in on every size.
The sheet publishes a 5-year No Hassle Replacement limited warranty, a 5-year parts limited warranty including compressor and coil, and an additional 5 years on parts with timely registration. It applies to the original purchaser/homeowner, and some limitations may apply. COMFORTMAKER does not cover labour.
AirGreen calculations (kW conversions, sums, percentage shares) are made on the published values and labelled as such.
AirGreen // Air conditioning and heating
We look at the spot outside, the refrigerant line route and the panel, then propose the size.
Page updated November 5, 2026