AirGreenGREE
GREE EliteThe GREE space at AirGreen · FLEXX R-410AGREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
FLEXX on R-410A · AH or BH: read the label
GREE FLEXX · R-410A · 2 to 5 tons · Updated Oct. 27, 2026

GREE FLEXX central heat pumps on R-410A. Which combination is certified, how to look after it, and what the R-32 FLEXX ULTRA changes at the same tonnage.

4 FLEXX systems on R-410A, from 24,000 to 60,000 BTU/h. The FLEXX36HP230V1AO covers 2 and 3 tons, the FLEXX60HP230V1AO 4 and 5 tons. NEEP and ENERGY STAR certify the FLEXX with its BH air handlers; our product sheets carry the AH units from the TTI-distributed manual. We show what is certified, and for which model.

41,000 → 54,000 BTU/hAt −15 °C, the maximum heat NEEP publishes for the 5-ton R-410A FLEXX (FLEXX60 + BH), then for the R-32 FLEXX ULTRA of the same tonnage.
30 mMaximum line-set length in the French FLEXX manual distributed by TTI, with a 15 m height difference. GREE Comfort’s US catalog prints up to 164 ft.
2 monthsThe outdoor unit manual asks for its heat exchanger to be cleaned at least once every two months.
  • 4R-410A FLEXX systems on this page
  • 2outdoor units: FLEXX36 and FLEXX60
  • 148 / 220.5 ozof R-410A from the factory, FLEXX36 and FLEXX60
  • 1,500 hof salt spray for the outdoor unit’s golden fins
AirGreen × GREEGREE Elite dealerFLEXX on R-410A, 2 to 5 tonsCompared with the R-32 FLEXX ULTRA91 FLEXX articles on our installations blogMontréal, Laval, Longueuil, South Shore, North Shore
R-410A or R-32

Your FLEXX against the FLEXX ULTRA of the same tonnage, one NEEP point at a time.

On the R-410A side, NEEP and ENERGY STAR certify the FLEXX only with its BH air handlers. Our product sheets carry AH air handlers, whose AHRI numbers appear on no list: the number of the installed combination is confirmed in the quote. The figures below are therefore those of the FLEXX + BH, named as such.

Same tonnage, two refrigerants

Pick the tonnage. On the left, the R-410A FLEXX in its only certified version, with a BH air handler; on the right, the R-32 FLEXX ULTRA of the same tonnage. In bold, the higher heat.

At −15 °C, maximum heat per NEEP

2 tons · R-410AFLEXX36 + FLEXX24..BH22,000 BTU/h
2 tons · R-32FLEXX ULTRA FXU2425,000 BTU/h
3 tons · R-410AFLEXX36 + FLEXX36..BH28,000 BTU/h
3 tons · R-32FLEXX ULTRA FXU3634,000 BTU/h
4 tons · R-410AFLEXX60 + FLEXX48..BH39,000 BTU/h
4 tons · R-32FLEXX ULTRA FXU4848,000 BTU/h
5 tons · R-410AFLEXX60 + FLEXX60..BH41,000 BTU/h
5 tons · R-32FLEXX ULTRA FXU6054,000 BTU/h

R-32 does not win everywhere

At −8.3 °C, NEEP publishes more maximum heat for the R-410A FLEXX than for the FLEXX ULTRA, at all four tonnages: 35,000 against 29,600 BTU/h at 3 tons. The gap flips at −15 °C: the FLEXX ULTRA gives more there at all four tonnages.

AH or BH

The indoor unit label decides what is certified.

Three ways to finish the FLEXX indoors on the same outdoor unit, plus its R-32 replacement. The suffix printed on the air handler or coil tells you which documents apply.

Indoor unitStatusWhat is published
FLEXX..BH2023 GREE Comfort catalog
Certified
NEEP and ENERGY STAR cold climate for all four sizes (AHRI 207256440 to 207256443), and a LogisVert amount for each. These are the figures in the tool above.
FLEXX..AHTTI-distributed manual · our sheets
Not listed
The French manual covers these four air handlers and their backup heat kits. Their AHRI numbers are not on NEEP, not on ENERGY STAR and not on the LogisVert list.
FLEXX24C to FLEXX60CA-coils, on a furnace
2 of 4
On the FLEXX36, the FLEXX24C and FLEXX36C are ENERGY STAR cold climate and on the LogisVert list. On the FLEXX60, the FLEXX48C and FLEXX60C are on NEEP, without ENERGY STAR.
FXU..R32AHFLEXX ULTRA on R-32
Certified
All four tonnages are on NEEP and ENERGY STAR cold climate. See the FLEXX ULTRA R32.

The 2023 catalog marks only the 24,000 BTU/h FLEXX as ENERGY STAR (YES NO NO NO); ENERGY STAR now lists all four FLEXX + BH in cold climate, certified in June and July 2026. Both are dated: the list rules for LogisVert. Lists checked by AHRI number on Oct. 26, 2026.

Two documents, two limits

The French manual and the US catalog do not give the same line-set length.

For the FLEXX36, the GREE Comfort catalog allows far more length and height difference than the French manual distributed by TTI; for the FLEXX60, the gap is a matter of a few feet. When two GREE documents differ, we work from the stricter one.

TTI-distributed outdoor manual2023 GREE Comfort catalog
Maximum line-set length30 m (98 ft)164 ft (2 and 3 tons), 100 ft (4 and 5 tons)
Maximum height difference15 m (49 ft)100 ft (2 and 3 tons), 50 ft (4 and 5 tons)
Refrigerant added30 g of R-410A per metre0.32 oz per foot
Reference length7.5 m, standard length31 ft pre-charged
Line sizesΦ3/8 and Φ3/43/8 - 3/4 in, flared connections

Manual CAT No. GREE_FLEXX_Outdoor_Unit_Installation_Manual_061921, distributed in French by TTI Climatisation; GREE Comfort catalog CAT NO. GREE_CATALOG_03222023, written for the US market. Both agree on the charge: 0.32 oz per foot is about 30 g per metre.

AirGreen × GREE

Your FLEXX, its documents, a team that reads them.

GREE designs the FLEXX and publishes its documents. AirGreen reads your indoor unit’s label, looks up the combination’s AHRI number and tells you what is certified, and what is not.

GREE

What GREE brings

  • Two outdoor unitsThe FLEXX36HP230V1AO for 24,000 and 36,000 BTU/h, the FLEXX60HP230V1AO for 48,000 and 60,000 BTU/h, per GREE Comfort’s 2023 catalog.
  • Golden fins outsideOutdoor coil salt-spray tested for 1,500 hours; blue fins rated 500 hours indoors.
  • Backup heat in the air handlerFLEXXHTR5KW to FLEXXHTR20KW kits for the AH air handlers, by size.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe read the indoor unit label, AH or BH, before we talk figures.
  • 91 FLEXX articlesArticles on our installations blog filed under FLEXX as of Oct. 14, 2026, all versions: central heat pumps and furnaces, R-410A and R-32 alike.
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: a FLEXX whose exact combination is known, and an honest comparison with the R-32 FLEXX ULTRA of the same tonnage.

The GREE shop

All 4 R-410A FLEXX systems, right below.

Each product sheet gives the outdoor unit and the AH air handler. For the R-32 version, see the FLEXX ULTRA R32 page; for air handlers alone, the GREE electric furnaces page.

GREE
Technician’s corner

R-410A FLEXX: the figures your technician will want to see.

The circuit

MCA 24 A and 35 A, MOCP 35 A and 45 A, recommended breaker 30 A and 40 A, for the FLEXX36 and FLEXX60.

2023 GREE Comfort catalog

The charge

148 oz of R-410A in the FLEXX36, 220.5 oz in the FLEXX60, pre-charged for 31 ft; beyond that, 0.32 oz per foot.

2023 GREE Comfort catalog

The AH air handler

21-1/4 x 21-1/4 x 48-1/4 in (540 x 540 x 1224 mm) for the 24 and 36; 24-3/4 x 21-1/4 x 57 in (630 x 540 x 1448 mm) for the 48 and 60.

TTI-distributed AH manual

Airflow, BH version

940, 1,000, 1,470 and 1,600 CFM, up to 1.0 in. W.C. external static pressure; 45 to 51 dB(A) indoors; 3.06 to 12.13 pints of water removed per hour.

2023 GREE Comfort catalog

The outdoor unit

37 x 32 1/4 x 18 1/8 in and 217 lb net for the FLEXX36; 39 3/8 x 53 5/8 x 14 1/2 in and 308 lb net for the FLEXX60.

2023 GREE Comfort catalog

FLEXX coils

17 1/2 × 23 × 21 1/4 in and 64 lb net (FLEXX24C, FLEXX36C); 24 1/2 × 28 1/2 × 21 1/4 in and 95 lb net (FLEXX48C, FLEXX60C).

2023 GREE Comfort catalog
Did you know?

Six things to know about the R-410A FLEXX. Flip the cards.

LogisVert · Hydro-Québec

LogisVert and the R-410A FLEXX: what the Oct. 27, 2026 list says.

To confirmOur FLEXX sheets, with an AH air handler: their AHRI numbers are not on the list. The amount follows the number of the installed combination.
$2,400 to $5,280FLEXX36 or FLEXX60 with a BH air handler (207256440 to 207256443), ENERGY STAR cold climate: $120 per 1,000 BTU/h at −8.3 °C.
$3,384The 3-ton R-32 FLEXX ULTRA: $96 less than the FLEXX + BH, because ENERGY STAR lists 28,200 BTU/h at −8.3 °C for it against 29,000. At the other tonnages: $2,472, $4,740 and $5,400.
$0A FLEXX already in place gets nothing: LogisVert guide v1.10 pays for a complete new system.

Indicative amounts, as listed on Oct. 27, 2026 by Hydro-Québec, which confirms them when you apply. On the FLEXX36, the FLEXX24C and FLEXX36C coils are listed too, at $2,352 and $2,784.

Questions

What people ask us about the R-410A FLEXX.

My FLEXX label ends in AH, not BH. Which figures apply?
The NEEP and ENERGY STAR figures on this page are those of the BH air handlers in the 2023 catalog. The TTI-distributed manual covers the AH units, but the AHRI numbers on our AH sheets appear on none of the lists we checked: we confirm your combination’s number before quoting a figure.
How long can the line set be on a FLEXX?
The French outdoor-unit manual distributed by TTI gives 30 m (98 ft) at most and a 15 m (49 ft) height difference, with 30 g of R-410A per extra metre. The US catalog prints up to 164 ft: we follow the manual.
Does my R-410A FLEXX qualify for LogisVert?
Not a FLEXX that is already installed: the LogisVert guide pays for a complete new system. For a new system, the Oct. 27, 2026 list includes the FLEXX + BH ($2,400 to $5,280) and the FLEXX24C and FLEXX36C coils, but not the AHRI numbers on our AH sheets. Indicative amounts, confirmed by Hydro-Québec when you apply.
What replaces a 3-ton R-410A FLEXX?
At the same tonnage, the R-32 FLEXX ULTRA: FXU36HP230V1R32AO and FXU36HP230V1R32AH. NEEP gives it at most 34,000 BTU/h at −15 °C, against 28,000 for the FLEXX + BH; at −8.3 °C it is the other way round, 29,600 against 35,000. Its charge goes from 148 oz of R-410A to 102.3 oz of R-32.
What warranty does GREE print for the R-410A FLEXX?
GREE Comfort’s 2023 catalog, written for the United States, prints 5 years on parts and 7 years on the compressor, residential and commercial alike. The TTI-distributed manuals print no term. For a specific FLEXX, the quote states the terms.
What does the FLEXX manual ask between service visits?
To clean the outdoor unit’s heat exchanger at least once every two months. And, at start-up, to leave the unit powered for 8 hours before running it, so the outdoor compressor crankcase is preheated.
AirGreen

A FLEXX to replace? We compare R-410A and R-32 at the same tonnage, at your home.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
91 FLEXX articlesPublished with photos on our installations blog, counted on Oct. 14, 2026.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
Catalog and manualsFigures from the 2023 GREE Comfort catalog, the TTI-distributed FLEXX manuals and lists checked by AHRI number.
Sources

Capacities and amounts: indicative, to be confirmed in the quote. Tool answers: AirGreen, from the published values above. Page updated Oct. 26, 2026; NEEP and ENERGY STAR records checked again that day, LogisVert list dated Oct. 27, 2026.