AirGreenGREE
GREE EliteThe GREE space at AirGreen · UNIX R-410AGREE Elite dealer: GREE training completed, priority access to original parts.
GREE Elite
Three indoor families · two condensers
GREE UNIX · R-410A · 2 to 5 tons · Updated Oct. 27, 2026

GREE UNIX central heat pumps on R-410A. Low static, high static or a coil on a furnace: the indoor unit’s label tells which figures GREE Canada published for yours.

4 UNIX systems on R-410A, from 24,000 to 60,000 BTU/h, on 2 GREE Canada condensers. The GUD36W/A-D(U) covers 2 and 3 tons, the GUD60W/A-D(U) 4 and 5 tons. Behind them sit three indoor unit families, and one question comes before the figures: which one is in your home?

A/A · AH2/A · GCATThree indoor units on the same two condensers: low static, high static or cased coil, per GREE Canada’s manual and brochure. Only the last two have published figures.
52 dB(A)Sound of the GUD36W/A-D(U) outdoor unit per GREE Canada, within a 45 to 56 dB(A) range; 58 dB(A) for the GUD60W/A-D(U). The measuring distance is not published.
4.2 → 2.9 kgFactory refrigerant in the 2- and 3-ton condenser: 4.2 kg of R-410A. The UNIX R32 condenser for the same tonnages holds 2.9 kg, of R-32.
  • 4R-410A UNIX systems on this page
  • 2GREE Canada condensers
  • 25 to 50 Parated static pressure of the AH2 air handlers
  • 30 daysbetween filter checks, in season
AirGreen × GREEGREE Elite dealerUNIX on R-410A, 2 to 5 tonsA/A, AH2/A or GCAT: read the label17 UNIX articles on our installations blogMontréal, Laval, Longueuil, South Shore, North Shore
Read the label

A/A, AH2/A or GCAT: three indoor units, three levels of proof.

The condensers do not change from one family to the next. What changes everything is the indoor unit: the low-static model on our sheets has no published figure, the high-static model has all of them, and the GCAT coil sits on a furnace.

What your indoor unit’s label says

The model is on the air handler’s or coil’s label. Pick the family, then the tonnage: you see what GREE Canada printed, what is certified today, and the UNIX R32 of the same tonnage.

What GREE Canada asks

Three habits written into the UNIX manual.

GREE Canada’s user’s manual is short on maintenance, but precise. Here is what it asks of the owner.

  1. The filter, every 30 daysCheck the air filter every 30 days during the heating and cooling seasons.
  2. Never under snowThe outdoor unit must never be buried, even partly, by ice or snow. Clear its underside after defrost cycles.
  3. A pre-season serviceGREE Canada recommends routine pre-season maintenance by a licensed HVAC contractor.

GREE Canada UNIX user’s manual, code 01122022, © 2022. It covers the GUD36W/A-D(U) and GUD60W/A-D(U) condensers, the low-static GUD..A/A-D(U) and the high-static GUD..AH2/A-D(U) air handlers.

AirGreen × GREE

One UNIX, three ways to finish it indoors. We check which one before we price anything.

GREE designs the UNIX; GREE Canada publishes its brochure and manual. AirGreen identifies the indoor unit, finds the right certificate and installs it all.

GREE

What GREE brings

  • Two condensers, four tonnagesThe GUD36W/A-D(U) for 24,000 and 36,000 BTU/h, the GUD60W/A-D(U) for 48,000 and 60,000 BTU/h.
  • Published airflowThe AH2 air handlers run from 960 to 1,600 CFM, 2 to 5 tons, per brochure 052024.
  • A coil for the furnaceGREE Canada also publishes GCAT cased coils for the same condensers.
AirGreen

What AirGreen brings

  • GREE Elite dealerGREE training completed, priority access to original parts.
  • Free estimateWe spot A/A, AH2/A or GCAT on your unit, then find its certificate.
  • 17 UNIX articlesArticles on our installations blog filed under UNIX as of Oct. 14, 2026, all versions: 16 of them cover the UNIX R32.
  • RBQ 5645-9605-01Licences 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.

The result: a UNIX whose family and certificate are known, and the right UNIX R32 model when it is time to replace it.

The GREE shop

All 4 R-410A UNIX systems, right below.

Each product sheet gives the condenser and the low-static air handler. For the R-32 version, see the UNIX R32 page; for the R-410A FLEXX, its FLEXX page.

GREE
Technician’s corner · AH2 air handlers

R-410A UNIX: brochure 052024, size by size.

GREE Canada 05202424,00036,00048,00060,000
Air handlerGUD24AH2/A-D(U)GUD36AH2/A-D(U)GUD48AH2/A-D(U)GUD60AH2/A-D(U)
CondenserGUD36W/A-D(U)GUD36W/A-D(U)GUD60W/A-D(U)GUD60W/A-D(U)
SEER2 / EER217.0 / 12.016.0 / 10.017.0 / 11.015.8 / 10.0
COP · HSPF24.20 · 9.03.50 · 9.03.60 · 9.03.45 · 9.0
Outdoor sound, dB(A)52 (45 – 56)52 (45 – 56)58 (48 – 61)58 (48 – 61)
Outdoor MCA / MOP24 / 35 A24 / 35 A35 / 45 A35 / 45 A
R-410A charge4.2 kg (148.8 oz)4.2 kg (148.8 oz)6.2 kg (220.8 oz)6.2 kg (220.8 oz)
Condenser, W x H x D820 x 940 x 460 mm820 x 940 x 460 mm1000 x 1363 x 370 mm1000 x 1363 x 370 mm
Condenser, net weight98.5 kg98.5 kg140.0 kg140.0 kg
Air handler, W x H540 x 1224 mm540 x 1224 mm630 x 1448 mm630 x 1448 mm

GREE Canada, UNIX R410A brochure, document 052024 (AH2 air handlers, not the ones on our sheets). Line set: 7.5 m standard, 3 m minimum, 30 m maximum and a 15 m height difference, ø 9.52 mm (3/8) and ø 19.05 mm (3/4) lines. AH2 depth: 540 mm. The sound measuring distance is not published.

Did you know?

Five things to know about the R-410A UNIX. Flip the cards.

LogisVert · Hydro-Québec

LogisVert and the R-410A UNIX: it all depends on the indoor unit.

To confirmOur low-static UNIX sheets: their AHRI numbers are not on the list. The amount follows the installed combination’s number, confirmed in the quote.
$5,280The highest R-410A UNIX amount: the 60,000 BTU/h system with an AH2 air handler (206249118). The AH2 systems start at $2,400 at 24,000.
$2,352 and $2,784The 2- and 3-ton GCAT coils (211644150, 211644151). The 4- and 5-ton ones have no ENERGY STAR record: no amount.
$0Keeping your UNIX earns nothing, and neither does replacing the indoor unit alone: the guide excludes replacing a single indoor or outdoor unit.

Hydro-Québec’s list of Oct. 27, 2026; these amounts stay indicative until you apply. The UNIX R32 of the same tonnage, on the same list: $2,472, $3,912, $4,740 and $5,400.

Questions

What people ask us about the R-410A UNIX.

How do I know whether my UNIX is low or high static?
Read the indoor unit’s label: GUD24A/A-D(U) is the low-static version, GUD24AH2/A-D(U) the high-static one, and so on up to the 60. GREE Canada’s user’s manual covers both. If the label starts with GCAT, it is a coil sitting on a furnace.
Is my R-410A UNIX on the LogisVert list?
The AH2 air-handler systems (206249116 to 206249119) are, from $2,400 to $5,280, as are the 2- and 3-ton GCAT coils. The AHRI numbers on our low-static sheets are not. And LogisVert only pays for a complete new system.
What replaces a 2-ton UNIX?
GREE Canada’s UNIX R32 at the same tonnage: GUD36W2/NhE-D(U) and GUD24AH2/G-D(U), AHRI 217120759. NEEP gives it at most 24,000 BTU/h at −15 °C, against 22,000 for the R-410A UNIX AH2, and the LogisVert list gives it $2,472.
How far can the condenser be from the indoor unit?
GREE Canada prints 30 m (98.4 ft) maximum, 3 m minimum and a 15 m (49.2 ft) height difference; the standard length is 7.5 m.
Does the 60,000 BTU/h deliver 60,000 BTU/h?
Not in rated heating: GREE Canada rates the 60,000 column at 54,000 BTU/h, within a 35,000 to 60,000 range. NEEP gives it at most 41,000 BTU/h at −15 °C, with the AH2 air handler.
Can my UNIX condenser work with my furnace?
Yes: GREE Canada publishes GCAT cased coils for the same condensers, and its Unix page describes a retrofit “with a furnace combined with a cased coil”. The gas or oil side of the furnace is done by a licensed partner; see the ADD-ON page.
AirGreen

A/A, AH2/A or GCAT? We identify it at the visit, then we price.

Free estimate at home. Montréal, Laval, Longueuil, South Shore and North Shore.

GREE Elite dealerGREE training completed, priority access to original parts.
17 UNIX articlesPublished with photos on our installations blog, counted on Oct. 14, 2026.
RBQ 5645-9605-01Licences 15.8, 15.10 and 16.
Brochure 052024Figures from GREE Canada’s UNIX brochure and manual, and lists checked by AHRI number.