01Only the liquid line counts
For the refrigerant charge, the LomoPlus UltraHeat sheets count the liquid line length only: below the pre-charged length, nothing to add; beyond it, 0.2 oz per foot (0.21 oz on the 42,000 compressor).
TOSOT sheets TM24H5O, TM36H5O and TM42H5O, “Piping requirement” section (November 4, 2024).
02Pre-charged for 98 or 131 ft
The 24,000 LomoPlus UltraHeat ships charged for 98 ft of line, the 36,000 and 42,000 for 131 ft. On the Lomo 23 side, the sheets read on October 28, 2026 gave 98 ft for the 24,000 and 131 ft for the 30,000 to 42,000.
TOSOT sheets TM24H5O to TM42H5O (November 4, 2024); TM24H4O to TM42H3O (read on October 28, 2026).
03Height: 26 to 49 ft
Between the outdoor unit and a head, the 24,000 LomoPlus UltraHeat sheet allows 26 ft; the 36,000 and 42,000 sheets, 49 ft. The 30,000 to 42,000 Lomo 23 units also allow 49 ft, but only 25 ft between two heads.
Same TOSOT sheets.