Zephyr central heat pump: down to -30 °C, from 2 to 5 tons.
The R-454B Zephyr series 6 central heat pump (ZE-6xxHPA + AH-6xxA air handler) heats down to -30 °C per its manual, is ENERGY STAR cold-climate certified, meets the “Most Efficient” criteria and qualifies for $2,448 to $4,440 in LogisVert. It connects to your ducts.
LogisVert amount of each pair, checked by AHRI number.
ENERGY STAR (Oct. 8, 2026); Hydro-Québec LogisVert tool (Oct. 6, 2026).
2, 3, 4 or 5 tons: tap to compare.
One ton equals 12,000 BTU/h. Each tonnage is a certified pair: the ZE-6xxHPA outdoor unit and the AH-6xxA air handler. The drawing compares certified heat at three temperatures with certified cooling (red mark).

R-410A central · 2 tons
See the product
R-410A central · 3 tons
See the product
R-410A central · 5 tons
See the productThe 3-ton (ZE-636HPA + AH-636A) keeps 32,000 BTU/h at -8.3 °C, as much as at +8.3 °C, per ENERGY STAR.Source: ENERGY STAR, AHRI 215381146.
Certified figures, pair by pair.
All four Zephyr pairs are cold-climate certified and meet the “Most Efficient” criteria. The same outdoor unit is also certified with DC cased coils (Aspen, per TTI), at lower ratings.
| 2 tonsZE-624HPA | 3 tonsZE-636HPA | 4 tonsZE-648HPA | 5 tonsZE-660HPA | |
|---|---|---|---|---|
| Zephyr pair: outdoor unit and air handler of the same tonnage | ||||
| AHRI | 215381145 | 215381146 | 215381147 | 215381148 |
| Certified cooling | 24,000 | 32,000 | 48,000 | 57,000 |
| SEER2 | 20 | 19.5 | 19 | 19 |
| EER2 | 12 | 11.7 | 12 | 11 |
| HSPF2 | 10 | 10.5 | 9 | 9 |
| Heat at +8.3 / -8.3 / -15 °C | 24,000 / 20,400 / 20,800 | 32,000 / 32,000 / 31,000 | 48,000 / 36,600 / 37,000 | 57,000 / 37,000 / 42,000 |
| COP at -15 °C | 2.3 | 2.15 | 2.52 | 2.46 |
| LogisVert | $2,448 | $3,840 | $4,392 | $4,440 |
| Status | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria |
| Pair with DC cased coil (Aspen, per TTI; “Ultra-Coil” series) | ||||
| Coil / AHRI | DC31D2J / 218160013 | DC37D3J / 218160014 | DC49B3J / 218160015 | DC61C4J / 218160016 |
| SEER2 / HSPF2 | 16 / 8.2 | 16.5 / 8.2 | 16.5 / 8.3 | 16.4 / 8.2 |
| Heat at -8.3 / -15 °C | 17,000 / 21,000 | 26,000 / 27,000 | 33,000 / 34,000 | 34,000 / 38,000 |
| COP at -15 °C | 1.95 | 1.8 | 1.9 | 2 |
Swipe the table.
ENERGY STAR w7cv-9xjt, Oct. 8, 2026. Each Zephyr pair also has a second AHRI number (215434507 to 215434510, air handler entered as “AH- 6xxA”) with the same SEER2 and HSPF2. The cased coil pair has been on the market since March 6, 2026 and certified since May 1, 2026, without meeting the “Most Efficient” criteria.
The 3-ton has the series’ highest HSPF2, 10.5; the 2-ton, the best SEER2, 20.Source: ENERGY STAR w7cv-9xjt.
From $2,448 to $4,440 per Zephyr pair.
Tap a pair to see Hydro-Québec’s math: heat at -8 °C times $120 per 1,000 BTU/h. Then enter your installation date.
- An air handler or ducts installed outside the insulated envelope, for example in the attic.
- Replacing a single coil, or a single indoor or outdoor unit.
- A central unit in a home with a geothermal system.
ZE-660HPA + AH-660A
July 8, 2027deadline passed
Source: Hydro-Québec, residential LogisVert participation guide v1.10 (Sept. 15, 2026) and eligible heat pump search tool (Oct. 6, 2026). ENERGY STAR required since Nov. 26, 2025; outdoor unit of at least 12,000 BTU/h; capped at 100% of the cost before taxes; apply no later than 9 months after installation; paid by mail 10 to 12 weeks after a complete application. Indicative amounts: Hydro-Québec sets them when you apply. Our LogisVert guide
The 5-ton qualifies for $4,440: 37,000 BTU/h at -8 °C, so 37 × $120 per 1,000 BTU/h, the highest amount of any Zephyr unit in our shop.Source: Hydro-Québec, LogisVert tool (Oct. 6, 2026), AHRI 215381148.
A central heat pump, from the outdoor unit to the vents.
The same system heats in winter and cools in summer, by moving heat instead of making it. Pick a mode: the air and refrigerant follow the path.
Red: warm air and hot refrigerant. Dashes move in the direction of the air.
Per Natural Resources Canada, 300,000 heat pumps were shipped to Canada in 2021, 20% more than gas furnaces.Source: Natural Resources Canada, “Electric heat pumps” page (modified Dec. 3, 2025).
At -15 °C, more than 2 kWh of heat per kWh.
The four Zephyr pairs keep a COP of 2.15 to 2.52 at -15 °C per ENERGY STAR. An electric furnace stays at 1. The rate panel gives the electricity prices that matter for an electrically heated home.
COP at -15 °C (5 °F), ENERGY STAR; resistance: 100% (US DOE).
Hydro-Québec, 2026 rate grid. Flex D events: 6 to 10 a.m. or 4 to 8 p.m., from December 1 to March 31, at most 120 hours per winter. Rate DT is for dual-energy systems; a central heat pump can be the electric side.
The 4-ton has the series’ best COP at -15 °C: 2.52, so 2.52 kWh of heat for each kWh of electricity.Source: ENERGY STAR, AHRI 215381147.
Rate DT, degree by degree.
Hydro-Québec’s Rate DT is for dual-energy systems: a main electric source, such as a central heat pump, and a backup fuel (natural gas, oil, propane or pellets) that must be able to heat the home in deep cold. With a fuel-burning furnace, the ZE-6xxHPA pairs with a cased coil, at lower ratings; the LogisVert amount of these pairs has not been verified. Slide the temperature.
Above the threshold: low electricity price.
Above the threshold: low electricity price.
Rate DT, Hydro-Québec grid as of April 1, 2026: 5.131¢/kWh above -12 or -15 °C depending on the region, 30.001¢/kWh below. For comparison, Rate D is 7.065 then 11.142¢/kWh. Hydro-Québec’s page does not say which regions use -12 or -15 °C: we check it for your address.
On Rate DT, a kWh used below the temperature threshold costs 30.001¢, 5.8 times the price above it (5.131¢).Source: Hydro-Québec, grid as of April 1, 2026; AirGreen math (30.001 ÷ 5.131).
Oil and combustion: what the rules say.
A central heat pump connects to the existing ducts, with the Zephyr air handler or, if you keep your furnace, a cased coil. Before replacing a heating appliance, here are the rules that apply in Quebec.
It connects to the duct system, with the Zephyr AH-6xxA air handler or, if you keep your furnace, a cased coil. From 2 to 5 tons.
See: Central heat pumpA starting point, not a rule: we confirm during the visit based on the rooms, the insulation and the existing ducts.
- Since December 31, 2023, it has been prohibited to install an oil appliance in an existing home, or to replace one with a fossil-fuel appliance, gas or propane included.
- In Montreal, combustion heating appliances are banned in new buildings (small buildings: October 1, 2024; others: April 1, 2025).
- The Chauffez vert program has not accepted applications since March 31, 2026.
- Per the RBQ, subclass 15.10 covers forced-air heating-cooling appliances if the contractor also holds 15.1, 15.1.1, 15.7 or 15.8: AirGreen holds 15.8, 15.10 and 16.
In Laval, an annual tax of $100 applies to each oil heating system, and $50 to each oil-electric dual-energy system still installed in a dwelling.Source: City of Laval, by-law L-12964 (codified Jan. 19, 2026).
R-410A or R-454B: what changed.
Our shop keeps three R-410A Zephyr central units, on quote. Series 6 moved to R-454B: a lower-GWP, class A2L refrigerant, hence the leak sensor in the air handler.
| R-410Aprevious generation | R-454Bseries 6 | |
|---|---|---|
| Models | ZE-24HPA, ZE-36HPA, ZE-60HPA (shop) | ZE-624HPA … ZE-660HPA + AH-6xxA |
| Refrigerant (GWP) | R-410A (2,090) | R-454B (470) |
| ASHRAE class | A1: non-flammable | A2L: mildly flammable |
| Refrigerant sensor | — | In the air handler (No. 18 in the manual) |
| TTI document | No sheet for these model numbers | Manuals Nos. 20 and 22 |
| ENERGY STAR | No record found (Oct. 8, 2026) | Cold climate, 4 pairs |
| LogisVert | Not verified: no ENERGY STAR record found for these numbers | $2,448 to $4,440 |
Swipe the table.
Sources: EPA SNAP (March 19, 2026); TTI manuals; ENERGY STAR w7cv-9xjt; LogisVert tool (Oct. 6, 2026).
EPA SNAP, March 19, 2026.
Series 6 R-454B has a GWP of 470, 77.5% less than the previous generation’s R-410A (2,090).Source: EPA SNAP (March 19, 2026); AirGreen math.
The Zephyr central unit and the heating rules.
Swipe left to right. In red: Zephyr; in green: rules and programs.
- Oil: new homes
No more oil appliances in new residential buildings.
Rule - Oil: existing homes
No more oil installations, nor replacement by a fossil fuel.
Rule - Series 6 R-454B
Market date of the four pairs per ENERGY STAR.
Zephyr - Montreal: small new buildings
Combustion heating appliances banned in small new buildings.
Rule - Montreal: other new buildings
The same ban extends to other new buildings.
Rule - LogisVert requires ENERGY STAR
Only certified heat pumps remain eligible.
Rule - End of Chauffez vert
Quebec’s oil and propane conversion program no longer accepts applications.
Rule - 2026 rates
Rate D: 7.065¢ and 11.142¢ per kWh; Rate DT: 5.131¢ and 30.001¢.
Rule - 6-year legal warranty
For heat pumps bought new from that date (OPC).
Rule
On February 3, 2023, Quebec’s electricity demand hit a record 43,124 MW. In cold snaps, heating can account for up to 80% of a household’s electricity, per Hydro-Québec.Source: Hydro-Québec, pages on using energy during cold snaps and on peak periods (hydroquebec.com), checked Oct. 8, 2026.
A ZEPHYR central unit, connected to your ducts by AirGreen.
ZEPHYR supplies the outdoor unit and the air handler of the same tonnage. AirGreen checks the ducts, chooses the tonnage and backup heat with you, installs and starts up.
What ZEPHYR brings
- Down to -30 °CPer the series 6 manual.
- Leak sensorIn the AH-6xxA air handler.
- ENERGY STARCold climate; “Most Efficient” criteria.
- Variable speedCompressor listed as “Continuously variable” by ENERGY STAR.
What AirGreen brings
- Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
- Free home estimateWe look at the rooms, where the units go and the line set route.
- Warranty registered for youWith TTI, free of charge: serial numbers, date, photos.
- RBQ 5645-9605-01Subclasses 15.8 (ventilation), 15.10 (refrigeration) and 16 (electrical).
The result: a properly sized central unit, checked ducts, a clear quote.
What is written, and what the law says.
TTI does not publish a warranty term for the series 6 central unit online; we put it on your quote. For a heat pump bought new on or after October 5, 2026, the law adds a 6-year warranty of good working order, counted from delivery.
TTI does not publish a warranty term for this product online (checked Oct. 8, 2026). We write it down on your quote.
For a heat pump or air conditioner bought new from a merchant on or after October 5, 2026, Quebec law adds a free, automatic 6-year warranty of good working order, counted from delivery (Office de la protection du consommateur). Under TTI’s parts policy (v3.4, July 17, 2026), labour to replace a part during that period falls on the installing contractor.
Service or repair by anyone not certified and authorized by TTI (or Kinghome) ends the manufacturer’s conventional warranty (TTI, s. 4.4).
If something breaks, you call the contractor who installed it; they file the claim with TTI.
TTI’s policy asks owners to clean the indoor unit filters at least once a month (s. 6.3).
We look at the rooms, where the units go and the line set route.
The exact model, the AHRI number, the indicative LogisVert amount when it applies.
Vacuum, refrigerant charge, heating and cooling tests.
We register the units with TTI for you: nameplate, serial numbers, invoice.
Our Zephyr central projects.
Each blog post shows one installation: the unit, the place, how it was done.




What people ask us about Zephyr central units.
No question matches. Call us at 514-316-2973.
We calculate it during the visit, based on the home and the ducts. One ton equals 12,000 BTU/h. The Zephyr pairs go from 2 to 5 tons.
Down to -30 °C per the series 6 manual; it cools from -15 to 52 °C. ENERGY STAR certifies its heat at -15 °C: 20,800 to 42,000 BTU/h depending on tonnage.
With the AH-6xxA air handler: $2,448 (2 tons), $3,840 (3), $4,392 (4) and $4,440 (5), per Hydro-Québec’s tool (Oct. 6, 2026). With a cased coil, the amount has not been verified; we confirm it on the quote.
Yes. With an existing furnace, the ZE-6xxHPA pairs with a DC cased coil (Aspen, per TTI; AHRI 218160013 to 218160016), certified at lower ratings (16 to 16.5 SEER2, 8.2 to 8.3 HSPF2) and without meeting the “Most Efficient” criteria. The LogisVert amount of these pairs has not been verified; we confirm it on the quote. An oil furnace can stay as backup, but it can no longer be replaced by a fossil-fuel appliance, nor repaired if it is over 20 years old. We check the furnace and ducts during the visit.
ENERGY STAR certifies it at 32,000 BTU/h of cooling, and the 5-ton at 57,000. We always give you the certified figure.
They are previous-generation models, on quote. TTI publishes no sheet for these model numbers; we confirm every figure and availability on the quote.
Since December 31, 2023, it has been prohibited to replace an oil appliance with a fossil-fuel appliance. A central heat pump with electric backup is an option; Chauffez vert has not accepted applications since March 31, 2026.
Hydro-Québec’s dual-energy rate: a main electric source, such as a central heat pump, and a backup fuel. Electricity costs 5.131¢/kWh above -12 or -15 °C depending on the region, and 30.001¢/kWh below (grid as of April 1, 2026).
For LogisVert, yes: installing indoor units or ducts outside the insulated envelope is not eligible. We look at the route during the visit.
TTI does not publish a warranty term online for the series 6 central unit and air handler: we put it on the quote. For a heat pump bought new on or after October 5, 2026, Quebec law adds a 6-year warranty of good working order, counted from delivery.
Nine months after installation. Hydro-Québec pays by mail, 10 to 12 weeks after a complete application. The invoice must show the RBQ licence and the AHRI or ENERGY STAR number.
Your Zephyr central unit, on your ducts, installed by AirGreen.
We come and see the ducts, choose the tonnage and backup with you, and hand you a clear quote with the AHRI number and the indicative LogisVert amount.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.
Sources checked October 6 to 9, 2026
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt, updated Oct. 8, 2026), checked Oct. 8, 2026: SEER2, EER2, HSPF2, capacities at 47, 17 and 5 °F, COP at 5 °F, cold-climate status, market date, by AHRI number.
- TTI, “Zephyr R454b 6 series centrale” (No. 20) and “Zephyr AH-6__A” (No. 22) manuals, readable parts, checked Oct. 8, 2026: operating range, subcooling, leak detection.
- TTI, “Case coil Aspen avec Zephyr centrale” (No. 19) and Aspen DC coil brochure (No. 35), tticlimatisation.com/manuels, checked Oct. 8, 2026; ENERGY STAR, AHRI 218160013 to 218160016 (“Ultra-Coil” series).
- Hydro-Québec, residential LogisVert participation guide, version 1.10, Sept. 15, 2026 (2026G448F), and eligible heat pump search tool, checked Oct. 6, 2026.
- Hydro-Québec, electricity rate grid as of April 1, 2026 (2026G028-2F), and Rate D, Flex D and DT pages, checked Oct. 8, 2026.
- TTI, parts availability policy, version 3.4, July 17, 2026 (ss. 4.3, 4.4 and 6.3: labour during the legal warranty, certified and authorized technician, filter cleaning).
- US EPA, SNAP, “Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps”, updated March 19, 2026 (GWP and ASHRAE classes); ASHRAE refrigerant designations (R-454B = R-32/R-1234yf 68.9/31.1) and Addendum g to Standard 34-2016 (class 2L).
- Regulation respecting oil-fired heating appliances, Gazette officielle du Québec, Part 2, April 21, 2021 (ss. 5 to 7); Québec.ca, Chauffez vert (updated March 31, 2026); City of Montreal, ban on combustion appliances in new buildings (Sept. 12, 2025).
- City of Laval, by-law L-12964, codified Jan. 19, 2026 (annual tax on oil and oil-electric dual-energy systems).
- Régie du bâtiment du Québec, licence subclasses 15.8, 15.10 and 16, checked Oct. 8, 2026.
- Hydro-Québec, pages on using energy during cold snaps and on peak periods (hydroquebec.com), checked Oct. 8, 2026.
- Natural Resources Canada, “Electric heat pumps” page, modified Dec. 3, 2025.
- US DOE, 10 CFR 430, Subpart B, Appendices M and M1 (SEER, HSPF, COP definitions); DOE Energy Saver, “Electric Resistance Heating”.
- TTI Climatisation Chauffage, home page and FAQ (tticlimatisation.com), checked Oct. 8, 2026.
- AirGreen: airgreen.ca product pages and “Nos réalisations” blog, as of Oct. 8, 2026.
- Office de la protection du consommateur, warranty of good working order (opc.gouv.qc.ca) and legal warranty notice, checked Oct. 9, 2026; Order in Council 1459-2025, Gazette officielle du Québec (s. 79.21 of the regulation under the Consumer Protection Act, in force Oct. 5, 2026): air conditioner and heat pump, 6 years.
- Hydro-Québec, residential LogisVert program page and fraud prevention page (hydroquebec.com), checked Oct. 9, 2026: no telephone or door-to-door solicitation for LogisVert.
LogisVert amounts are indicative: Hydro-Québec sets them when you apply.
Zephyr central units, right below.
Each product page matches a tonnage. Prices on quote. Free home estimate.