MIDEA28 4-Zone Heat Pump | Compressor: 48,000 BTU | Montreal, Laval, South Shore and North Shore

In stock
SKU: MO6HX-H48B-2A-4-1
48,000BTU/h · 4 heads
−30 °Cheats down to
$5,400LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientOptional Wi-FiR-454BUp to 6 heads
Areas
Talk to a technician · 514 316-2973
Outdoor unit MO6HX-H48B-2APossible indoor models MSEHU-H06B-2A, MSEHU-H09B-2A, MSEHU-H12B-2A, MSEHU-H18B-2A, MSEHU-H24B-2A, MSEHU-H33B-2AAHRI 215471466· ENERGY STAR 3627492
In short

The Midea28 48 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. it delivers 45,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $5,400 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

4 rooms, one outdoor unit.

Compared with the 82 multi-zone systems of 48,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 387273AHRI 215471466LogisVert · October 1, 2026
+HSPF2 11.0Rank 1 (tied) of 78. Class median: 10.0.
+Indoor head from 20 dB(A)Rank 6 (tied) of 78. Class median: 28 dB(A).
+$5,400 LogisVert grantRank 6 (tied) of 67. Class median: $4,320.
!Good to know: 65 dB(A) outdoorsRank 56 of 82; class median: 64 dB(A).
45,000BTU/h certified at −8 °C
−30 °Cstill heating
4 → 6heads, on the same unit
2.6COP at −8 °C
$5,400LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

MO6HX-H48B-2A

Outdoor unit

One compressor for the whole house. It supplies up to 6 heads and modulates from 13,000 to 45,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
23
27,000BTU
234
36,000BTU
2345
48,000BTU
23Here56

Midea28 48 000 · 4 zones

45,000 BTU/h
at −8 °C
$5,400
LogisVert

Up to 6 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 97 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
13,000 → 57,000 BTU/h
-8 °C
12,000 → 45,000 BTU/h
-15 °C
10,000 → 47,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling23.0
Scale 1 – 30Median: 21.3
Rank 9 (tied) of 78 in its class.
HSPF2 · seasonal heating11.0
Scale 1 – 15Median: 10
Rank 1 (tied) of 78 in its class.
EER2 · cooling in peak heat12.0
Scale 1 – 20Median: 12
Rank 30 (tied) of 78 in its class.
COP at −15 °C2.0
Scale 0 – 4Median: 2
Rank 29 (tied) of 71 in its class.
ENERGY STAR Most EfficientCold climate · ID 3627492 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

45,000 BTU/h÷ 1,000 ×$120=$5,400

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215471466). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 82 multi-zone systems of 48,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone4 wall units
On the wall1 outdoor unit4 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$5,400 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.5 in
MO6HX-H48B-2ADepth 16.38 in
37.5 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 37 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 37 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

20
47
65
28
64
20 dB(A)3040506070
20 Reference head, lowest speed47 Reference head, highest speed28 Class indoor median65 Outdoor unit64 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
13,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−30 °CColdest certified pointNEEP still lists 24,600 BTU/h at a COP of 1.27 at −22 °F.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTU · 4 tonsSheet
Certified cooling at 35 °C47,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)23.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)11.0AHRI
HSPF2, region V (coldest)9NEEP
Dehumidification6.97 pints/hSheet
Heating
Capacity at +8.3 °C49,000 BTU/h · COP 3.7NEEP
Capacity at −8 °C45,000 BTU/h · COP 2.6NEEP
Capacity at −15 °C47,000 BTU/h · COP 2.0NEEP
Capacity at −30 °C (max.)24,600 BTU/h · COP 1.27NEEP
Modulation range13,000 – 45,000 BTU/hNEEP
Heats down to−30 °CSheet
Zones and heads
Zones on this product4 Zones (Quad Zone)Sheet
Maximum zones6 ZonesSheet
Possible indoor modelsMSEHU-H06B-2A, MSEHU-H09B-2A, MSEHU-H12B-2A, MSEHU-H18B-2A, MSEHU-H24B-2A, MSEHU-H33B-2ASheet
Combinations offered6 · 6+18+18+18 … 12+12+18+18Sheet
Indoor dimensions (W × D × H)33.38 × 9.13 × 11.75 inSheet
Vertical louversManualSheet
Horizontal louversAutoSheet
Airflow (reference head)441 CFMSheet
Indoor sound (reference head)20 – 47 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.5 x 16.38 x 52.5 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound65 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)37 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-454BSheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI215471466AHRI
ENERGY STARYes · cold climate · ID 3627492ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$5,400LogisVert
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 0 yrsSheet
AirGreen extended warrantyIncludedSheet
17 · Official brochures

The manufacturer’s documentation, as PDF.

18 · Description

Everything we have written about this system.

Stable and lasting comfort for your entire property

At AirGreen, we offer the MIDEA28 4-zone heat pump with 48,000 BTU compressor , a complete heating and cooling solution for homeowners looking for reliable performance. With its multi-zone design and operation down to -30 °C, this model fits perfectly with the needs of homes and businesses in Montreal , Laval , Longueuil , the North Shore and the South Shore . Here we would like to present the concrete details of this product, the specifics of its installation and the benefits we have observed among our customers.

Why choose a 4-zone heat pump?

The multi-zone heat pump meets the realities of large properties, or those whose room distribution sometimes complicates air diffusion. With the MIDEA28 4-zone heat pump , you benefit from a single outdoor unit to serve up to 4 indoor units, each individually controllable. This allows for remarkable thermal balance in the different zones of a building, while promoting a reduction in energy consumption thanks to the modularity of the device.

Essential technical characteristics

  • Heating capacity : down to -30°C to face our Montreal winters.

  • Cooling capacity : 48,000 BTU , ideal for covering large areas.

  • R-454B refrigerant gas : recognized as a more environmentally friendly solution than conventional gases.

  • SEER2 : 23.0, a high rating that indicates excellent seasonal efficiency in air conditioning mode.

  • HSPF2 : 11.0, reflecting appreciable heating performance.

  • EER2 : 12.0, for a satisfactory ratio between the electrical energy consumed and the cooling delivered.

  • Optional WiFi : Allows remote management and monitoring, very convenient for owners wanting smart control.

  • Noise level : 65 dB(A) in outdoor mode, which remains discreet in most residential environments.

  • Warranty : 12 years on the compressor, 12 years on parts and 10 years on labor. An extended warranty (10-10-10) is also included.

Real example of installation in Boucherville

We recently installed a MIDEA28 4-zone heat pump in a home in Boucherville, on the South Shore . The homeowner had a basement, a ground floor, and an upper floor, each with different thermal requirements. By adding four wall-mounted units tailored to each space, the family was able to benefit from precise temperature control in the bedrooms, family room, and kitchen. The user configured time slots specific to each unit, reducing overall energy costs while ensuring consistent comfort.

How 4-Zone Design Promotes Energy Savings

  1. Individualized management : Heat or air condition only the rooms actually occupied.

  2. Performance by zone : Limit losses in low-traffic areas.

  3. Automatic adaptation : Thanks to the compressor inverter, the heat pump modulates its power according to the overall or specific demand of each zone.

LogisVert Grant

A crucial piece of information not to be overlooked: the LogisVert Provincial Grant associated with the MIDEA28 4-zone heat pump can reach $5,280 (updated May 1, 2025). This grant encourages the adoption of energy-efficient HVAC systems. We have often observed, during our interventions in Montreal , Laval and surrounding municipalities, that this type of financial support encourages homeowners to adopt greener solutions, by modernizing their old, less efficient electric heating or central air conditioning systems.

Installation process at AirGreen

We ensure that we deploy an optimal HVAC installation , taking into account:

  • The location of the outdoor unit : the device must be placed in a location accessible for maintenance, while minimizing noise pollution for the resident and the neighborhood.

  • Refrigeration duct passage : to ensure discreet integration, we provide wall passages reducing the length of piping.

  • Indoor units : We evaluate both the surface area of ​​each room and the position of the furniture to take advantage of air circulation.

  • Electrical requirements : with 220 V required, we ensure compliance with the standards and installation codes in force in Quebec.

Each step is overseen by our professional refrigeration engineers , who have years of experience in residential and commercial projects. We have often found that the success of a commissioning depends on a rigorous upstream study (load calculations, structural validations, etc.).

Recommended maintenance and follow-up

To maximize the durability of the MIDEA28 4-zone heat pump , we recommend regular HVAC maintenance , including:

  • Cleaning the interior filters : to remove accumulated dust and pollen, which can affect the efficiency of the system.

  • Check electrical connections : at least once a year, especially before the heavy heating season.

  • Compressor Inspection : Check refrigerant charge, ensure there are no leaks and calibrate pressures according to manufacturer's recommendations.

  • Examine exterior parts : remove anything that could obstruct the heat exchanger (leaves, debris, accumulated snow).

Our after-sales service technicians, based in Montreal and Boucherville , are trained to handle these interventions. The benefit of a proactive annual inspection is reflected in product longevity and energy savings. Some of our customers have experienced slightly reduced performance due to lack of maintenance, but prompt intervention has restored normal operation.

Adaptability to Quebec winters

Our winters are known for their extreme low temperatures. This is where the MIDEA28 4-zone heat pump stands out. Its operation down to -30°C makes it capable of providing efficient heating, even in the bitterest cold. Many of our customers on the North Shore , where temperatures can sometimes be harsher, confirm that their homes remain warm and comfortable without constantly resorting to expensive backup systems.

Some examples of successful installations with AirGreen

  • Laval : Installation in a multi-room condo where the owner wanted to thermally insulate the bedrooms to save energy at night. The 4-zone heat pump allowed for lower temperature settings in unoccupied rooms.

  • Longueuil : intergenerational house, two separate main areas, each with a dedicated interior unit, plus two other units for the basement and the garage converted into a workshop.

  • Montreal : project in a rental duplex, where the owner chose to install two units per floor in order to offer its tenants the comfort of individual control while limiting the complexity of maintenance.

MIDEA28 and its multiple combinations

Although the unit is configured for 4 zones as standard, it can accommodate up to 6 indoor units (in the MIDEA range). This provides flexibility for future projects, in the event of a home extension or space transformation. In addition, compatibility with different types of units (wall-mounted, discrete ducts, consoles) opens up possibilities in terms of architectural configuration.

Why choose AirGreen?

  1. Expertise and advice : our team is made up of recognized specialists in HVAC installation and HVAC maintenance , having successfully completed a multitude of projects, both residential and commercial.

  2. Transparent approach : we always present a clear final offer, allowing us to limit cost overruns once the project is completed.

  3. Complete after-sales service : we remain available for any questions, adjustments or troubleshooting, even long after installation.

  4. Guaranteed savings : the combination of an efficient heat pump and existing subsidies significantly reduces your energy bill, while increasing the added value of your property.

  5. Positive customer experience : several testimonials highlight the reliability of our refrigeration engineers and the cleanliness of our sites.

Tips for maximizing yield throughout the seasons

  • Keep the outdoor unit clear : In winter, a buildup of snow or ice can reduce airflow and disrupt the performance of the heat pump.

  • Program operating ranges : adjust the power required in each zone, taking into account the actual occupancy of the rooms (night/day, week/weekend).

  • Carry out an annual inspection : call on our maintenance services, particularly before the cold weather and before the summer period.

  • Monitor consumption : a sudden change in the electricity bill or the behavior of the heat pump may be a sign of an anomaly (clogged filters, drop in refrigerant, etc.).

Testimonial from a satisfied customer on the North Shore

"Since installing the MIDEA28 4-zone heat pump by AirGreen, our home has been comfortable all year round. We particularly appreciate being able to air condition just the living room or the bedroom, as needed, without overusing it. Its operation down to -30°C surprised us: we didn't even need our old space heater last winter!"

Trust and guarantees

Our collaboration with MIDEA allows us to offer a 12-year compressor warranty , 12-year parts warranty , and 10-year labor warranty . This coverage demonstrates the manufacturer's reliability and the strength of our HVAC maintenance service. We have regularly observed with our customers in Montreal , Laval , and the surrounding areas that this warranty enhances peace of mind and encourages better monitoring of the heat pump.

Conclusion

The MIDEA28 4-zone heat pump is a smart choice for any home or business requiring precise temperature control, high efficiency, and long-term reliability. Its 48,000 BTU compressor meets the demands of large spaces, while its versatility makes it a flexible solution for different building types.

Still unsure or have specific questions about possible configurations? Contact us at AirGreen for a clear and personalized quote. We offer a 100% free on-site estimate, whether you live in Montreal , Laval , Longueuil , on the North Shore or the South Shore . Our team will be happy to guide you step by step to select the best HVAC installation for your project.

19 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 45,000 BTU/h at −8 °C, 47,000 at −15 °C and 24,600 at −30 °C.

How many heads can I connect?

Up to 6 on this outdoor unit. This product is configured for 4 heads.

Can I mix head sizes?

Yes. The “Zones” menu offers 6 combinations, from 6+18+18+18 to 12+12+18+18 (in thousands of BTU). Each head is sized for its room.

How much is the LogisVert grant?

$5,400 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3627492. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 24,600 BTU/h with a COP of 1.27.

Is it noisy?

Indoors, the reference head goes down to 20 dB(A). Outdoors, 65 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts; labour is not included by the manufacturer. AirGreen extended warranty: included.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $5,400AHRI 215471466 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 387273 (AHRI 215471466): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 3627492.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.