139 models · 8 brandsUpdated September 30, 2026
Packaged heat pump · Montréal, Laval, Longueuil, South Shore, North Shore

Packaged heat pump: all the comfort in one box, sitting on your roof.

A single outdoor unit heats, cools and moves the air through the whole building. No refrigerant lines inside your walls. We install 139 models from 8 brands, from 2 to 12.5 tons, with a free in-home estimate.

Free estimate · 30 seconds

We’ll look at your roof, for free.

Name and email are enough. We call you back to book the visit.

My setup Optional: three clicks in “Find your packaged unit” and it shows up here.
Your building (one click)
Animation: click a season
Heat pulled from outsideHouse heat pushed outside21 °C22 °C21 °C22 °C21 °C22 °COutside -15 °C · inside 21 °COutside 31 °C · inside 22 °CSupply · return

In winter, the unit captures heat from the outdoor air, even cold, and pushes it through the ducts to every floor.

139packaged units in our catalogue
8 brandsDaikin, York, Trane, Goodman, Lennox, Gree, Tosot, Kinghome
2 to 12.5 tfrom bungalow to commercial roof
-30 °Cheating on the Rooftop R32, per the spec sheet
01 · Find your packaged unit

Which packaged heat pump for your building?

Three clicks: your building, its size and what matters most. The size in tons and the matching series from our catalogue show up right away.

1. Your building
2. Area to heat
1,800 sq ft
3. What matters most
3tons
1,800 sq ft × 18 BTU/h = 32,400 BTU/h, or 2.7 tons → 3 tons in the catalogue. Indicative: we confirm at the visit based on insulation and windows.
See the matching packaged units
Your setupPlex, flat roof · 1,800 sq ft · 3 tons · priority deep cold
Rooftop R32, thermopompe monobloc
Gree · Tosot · Kinghome
Rooftop R32
Available in 3 tons
SEER 18.0HSPF 8.3 to 8.8R-322, 3, 4, 5 t
21,800 BTU/h at -8.3 °C (certified rating)

ENERGY STAR cold climate, heating down to -30 °C per the spec sheet.

See the 10 models
Daikin DP16HM, thermopompe monobloc
Daikin
Daikin DP16HM
Available in 3 tons
SEER 15.5 to 16.0HSPF 8.2R-410A2, 2.5, 3, 3.5, 4, 5 t

ENERGY STAR from 3 to 5 tons per our sheets.

See the 6 models
Trane XL15c, thermopompe monobloc
Trane
Trane XL15c
Available in 3 tons
SEER 15.0HSPF 8.2 to 8.4R-410A2, 2.5, 3, 3.5, 4, 5 t

All six sizes are ENERGY STAR certified per our sheets.

See the 6 models
Suggestions to discuss, not a quote: the right model also depends on the roof, the ducts and the electrical.

Key point: starting point of 18,000 BTU/h per 1,000 sq ft, then we confirm at the visit based on insulation and windows.

02 · Packaged or split

What is a packaged heat pump, and how is it different from a central split system?

A packaged heat pump puts in one outdoor unit everything a central split system spreads over two. Switch views to see what disappears from the basement.

BASEMENTIndoorOutdoorRefrigerant linesAll-in-one, outsideBasement stays free
The packaged unit
  • One unit, outside: roof, ground pad or commercial roof.
  • No refrigerant lines inside the building.
  • Nothing in the basement: the space stays yours.
  • Ducts come in through the roof or the wall.
CriterionPackagedCentral splitWall-mounted (ductless mini-split)
UnitsOne, outsideTwo: outside + insideOne outside + one or more heads
Refrigerant inside the homeNoneTwo lines to the indoor unitLines to each head
Space used indoorsNoneCoil or furnaceWall heads
DuctsYes, whole buildingYes, whole buildingNo
Typical locationFlat plex roof, ground pad, commercial roofHouse with a basementRoom by room
LogisVert (guide 1.10)Not namedNamed (split)Named (mini-split)
AirGreen catalogue139 packaged unitsCentral heat pumpsWall-mounted heat pumps
Units
Packaged: One, outside
Central split: Two: outside + inside
Wall-mounted: One outside + one or more heads
Refrigerant inside the home
Packaged: None
Central split: Two lines to the indoor unit
Wall-mounted: Lines to each head
Space used indoors
Packaged: None
Central split: Coil or furnace
Wall-mounted: Wall heads
Ducts
Packaged: Yes, whole building
Central split: Yes, whole building
Wall-mounted: No
Typical location
Packaged: Flat plex roof, ground pad, commercial roof
Central split: House with a basement
Wall-mounted: Room by room
LogisVert (guide 1.10)
Packaged: Not named
Central split: Named (split)
Wall-mounted: Named (mini-split)
AirGreen catalogue
Packaged: 139 packaged units
Central split: Central heat pumps
Wall-mounted: Wall-mounted heat pumps

Key point: a packaged unit keeps the refrigerant outside and frees up the basement; it needs ductwork.

03 · How it works

Open the box: seven parts, one unit.

Tap the numbers. Switch seasons: the refrigerant reverses and the same unit goes from heating to cooling.

OUTDOOR SIDEHOUSE SIDE (TO THE DUCTS)
Tap a number
Seven parts, one box.

Each number on the cutaway opens the part and explains what it does. Switch seasons to see the refrigerant change direction.

Heating: the outdoor coil captures heat outside, the compressor concentrates it, the indoor coil gives it to the home’s air.

OUTDOOR SIDEHOUSE SIDE (TO THE DUCTS)
Tap a number
Seven parts, one box.

Each number on the cutaway opens the part and explains what it does. Switch seasons to see the refrigerant change direction.

Heating: the outdoor coil captures heat outside, the compressor concentrates it, the indoor coil gives it to the home’s air.

04 · Our packaged heat pump brands

Eight brands, 139 packaged units, from 2 to 12.5 tons.

Daikin, York, Trane, Goodman, Lennox, Gree, Tosot and Kinghome: filter, open a card, then the brand’s collection.

The 139 packaged units in our catalogue, by brand
Tap a segment to open the brand
Daikin 48 · 35 %York 43 · 31 %Trane 16 · 12 %Goodman 12 · 9 %Lennox 10 · 7 %Gree 4 · 3 %Tosot 4 · 3 %Kinghome 2 · 1 %
Packaged Heat Pump System | Installation in Montreal, Laval, Longueuil, South Shore and North Shore - AirGreen Unit
Our packaged heat pumps, installed across Montréal, Laval, Longueuil, the South Shore and the North Shore.
8 brands · 139 models shown
Packaged Heat Pump System York | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 12.5 tonsSEER 13.4 to 14.3R-454B and R-410A
See the 43 York models
Packaged Heat Pump System Trane | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 16 Trane models
Packaged Heat Pump System Goodman | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 15.5 to 16.0R-410A
See the 12 Goodman models
Packaged Heat Pump System Lennox | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 10 Lennox models
Packaged Heat Pump System Daikin | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 48 Daikin models
Packaged Heat Pump System Gree | Montreal, Laval, Longueuil, South Shore, North Shore
2, 3, 4 and 5 tonsSEER 18.0R-32
See the 4 Gree models
Packaged Heat Pump System Tosot | Montreal, Laval, Longueuil, South Shore, North Shore
2, 3, 4 and 5 tonsSEER 18.0R-32
See the 4 Tosot models
Packaged Heat Pump System Kinghome | Montreal, Laval, Longueuil, South Shore, North Shore
3 and 5 tonsSEER 18.0R-32
See the 2 Kinghome models
8 brands · 139 models shown
Packaged Heat Pump System York | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 12.5 tonsSEER 13.4 to 14.3R-454B and R-410A
See the 43 York models
Packaged Heat Pump System Trane | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 16 Trane models
Packaged Heat Pump System Goodman | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 15.5 to 16.0R-410A
See the 12 Goodman models
Packaged Heat Pump System Lennox | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 10 Lennox models
Packaged Heat Pump System Daikin | Montreal, Laval, Longueuil, South Shore, North Shore
2 to 5 tonsSEER 14.0 to 16.0R-410A
See the 48 Daikin models
Packaged Heat Pump System Gree | Montreal, Laval, Longueuil, South Shore, North Shore
2, 3, 4 and 5 tonsSEER 18.0R-32
See the 4 Gree models
Packaged Heat Pump System Tosot | Montreal, Laval, Longueuil, South Shore, North Shore
2, 3, 4 and 5 tonsSEER 18.0R-32
See the 4 Tosot models
Packaged Heat Pump System Kinghome | Montreal, Laval, Longueuil, South Shore, North Shore
3 and 5 tonsSEER 18.0R-32
See the 2 Kinghome models
Swipe to see the other brands.

Key point: the widest choice is at Daikin (48) and York (43); the only ENERGY STAR cold-climate units are the Gree, Tosot and Kinghome Rooftop R32.

05 · Compare brands

Which brand is the most efficient?

On our spec sheets, the Gree, Tosot and Kinghome Rooftop R32 have the highest SEER (18.0). Compare all eight brands on the same scale, then in the full table.

12141618
Tap a brand.

Each bar runs from the brand’s least efficient model to its most efficient. The further right, the better.

BrandModelsSeriesSizesSEERHSPFRefrigerantENERGY STAR
Daikin48DP16HM · DP16HH · DP5HH · DP5HM · DP14HH · DP14HM · DP3HH · DP3HM2 to 5 tons14.0 to 16.08.0 to 8.3R-410A4 DP16HM models (3, 3.5, 4 and 5 tons)
York43PH3 · PHE4 · Sunline WN/XN · Sun Core · Sun Pro WP/XP2 to 12.5 tons13.4 to 14.36.7 to 8.0R-454B and R-410ANone on our sheets
Trane16XL15c · XR13-4H · XR13-4C2 to 5 tons14.0 to 16.08.0 to 8.4R-410AAll 6 XL15c
Goodman1216 SEER vertical · 16 SEER horizontal2 to 5 tons15.5 to 16.08.0 to 8.2R-410A3 models (3, 3.5 and 4 tons)
Lennox10LRP14HP · LRP16HP2 to 5 tons14.0 to 16.08.0 to 8.2R-410ANone on our sheets
Gree4Rooftop R322, 3, 4 and 5 tons18.08.3 to 8.8R-32All 4, cold climate
Tosot4Rooftop R322, 3, 4 and 5 tons18.08.3 to 8.8R-32All 4, cold climate
Kinghome2Rooftop R323 and 5 tons18.08.3 to 8.5R-32Both, cold climate
Values from the AirGreen catalogue spec sheets, read on September 30, 2026. SEER and HSPF as listed on each sheet.
05 · Compare brands

Which brand is the most efficient?

On our spec sheets, the Gree, Tosot and Kinghome Rooftop R32 have the highest SEER (18.0). Compare all eight brands on the same scale, then in the full table.

12141618
Tap a brand.

Each bar runs from the brand’s least efficient model to its most efficient. The further right, the better.

BrandSEERRefrigerant
Daikin
48 models · 2 to 5 tons
14.0 to 16.0R-410A
York
43 models · 2 to 12.5 tons
13.4 to 14.3R-454B and R-410A
Trane
16 models · 2 to 5 tons
14.0 to 16.0R-410A
Goodman
12 models · 2 to 5 tons
15.5 to 16.0R-410A
Lennox
10 models · 2 to 5 tons
14.0 to 16.0R-410A
Gree
4 models · 2, 3, 4 and 5 tons
18.0R-32
Tosot
4 models · 2, 3, 4 and 5 tons
18.0R-32
Kinghome
2 models · 3 and 5 tons
18.0R-32
06 · Québec cold

Does a packaged heat pump heat in the dead of winter?

Yes: the Rooftop R32 heats down to -30 °C per its spec sheet, and the 3-ton still delivers 21,800 BTU/h at -8.3 °C. Drop the temperature to see.

1. Pick the size
2. Drop the temperature
-8 °C
-35 °C-8.3 °C: certified point+15 °C
Gree Rooftop R32 · AHRI 215866830 · HSPF 8.5 · 63 dB outdoor. Tosot and Kinghome: same certified capacities.
Comfort zone
It heats with ease.

At -8.3 °C, the certified rating of the 3 ton unit still delivers 21,800 BTU/h. Milder than that, it delivers more.

Certified capacity at -8.3 °C
21,800BTU/h
61 % of rated capacity (36,000 BTU/h)
See the model’s spec sheet
How much power is left at -8 °C, in BTU/h
Rated capacityRooftop R32 packaged unit at -8.3 °CMidea EVOX G3 central split at -8 °C
Certified ratings (AHRI Gree 216763049 to 215866831, Midea 215471340 to 215471345). Tap a size to show it in the thermometer.

Key point: at -8 °C, a cold-climate central split keeps more power; the packaged unit keeps everything outside.

07 · Where it goes

On the roof, on the ground or on a commercial building: each spot has its rules.

A packaged unit lives outside. Here is what that changes, and what your city may require: 56 of the 194 municipalities in our directory ask for a permit.

Flat plex roof

The Montréal classic. The unit is lifted onto the roof and the ducts run down through the building. Nothing on the ground, nothing in the yard, nothing in the units.

Watch for
  • Lifting, often by crane
  • Roof support and waterproofing
  • Longueuil and Repentigny: unit hidden from the street
  • Plateau-Mont-Royal: visible unit = urban planning advisory committee
  • Verdun: metal screen
Your city’s rules (194 municipalities)
08 · Fresh air

Do you need an air exchanger with a packaged unit?

The packaged unit heats and cools the air; the air exchanger renews it. Two questions to see whether an HRV or an ERV suits you, and 256 exchangers from 7 brands.

In winter, at your place…
Answer to see whether an HRV or an ERV works better with your packaged unit.
Fresh air from outsideStale air outStale air from roomsFresh air to roomsHeat onlyHeat and humidity

An HRV recovers heat from stale air to warm the fresh air coming in. It does not exchange humidity: it helps remove excess moisture in winter, like condensation on windows.

The perfect pair

The packaged unit heats, cools and moves the air. The exchanger renews it. Both share the same ducts, and the same team connects them (RBQ 15.8 Ventilation).

See all air exchangers
09 · Rebates

Does a packaged heat pump qualify for LogisVert?

The LogisVert guide in force (version 1.10, September 15, 2026) names split and mini-split systems, not packaged units. Here is the gap, size by size.

Same size, two systems:
Packaged
Gree Rooftop R32 · 3 tons
Heating at -8 °C21,800 BTU/h
LogisVert (indicative)Not provided
  • Everything outside, on the roof or on the ground
  • No refrigerant lines inside the home
  • Packaged units not in the LogisVert guide 1.10
See the spec sheet
Central split, ENERGY STAR cold climate
Midea EVOX G3 · 3 tons
Heating at -8 °C33,000 BTU/h
LogisVert (indicative)$3,960
  • Outdoor unit + indoor unit (coil or furnace)
  • Refrigerant lines between the two
  • 33,000 ÷ 1,000 × $120 = $3,960, max. 100% of cost
See the spec sheet

Honestly: the LogisVert guide v1.10 (September 15, 2026) names split and mini-split systems, not packaged units. If the rebate weighs in your decision, we price both options at the visit. Apply to Hydro-Québec no later than 9 months after installation. LogisVert simulator

Indicative LogisVert, by size
Guide 1.10 formula: BTU/h at -8 °C ÷ 1,000 × $120, up to 100% of the pre-tax cost.

Key point: if the rebate matters in your choice, we price both options at the visit.

10 · Refrigerant

R-410A, R-454B or R-32: which refrigerant is in your packaged unit?

Three refrigerants in our catalogue, two of them next-generation with a GWP three to four times lower. Tap one to compare.

R-410AGWP 2,088 · 105 models
R-454BGWP 466 · 24 models
R-32GWP 675 · 10 models
GWP: global warming potential over 100 years (IPCC AR4), 1 = CO2. Counts: catalogue filters.
R-454B

York’s chosen replacement. The lowest GWP of the three. A2L-rated, mildly flammable: handled by a trained technician.

In our catalogue: 24 packaged units · York PH3, Sunline WN, Sun Core WQE and WYE, Sun Pro WP
11 · Installation

How does a packaged heat pump installation go?

Six steps, one team, and a written final offer before the first bolt. Get ready for the visit by ticking the list.

1
Free visit

A technician looks at the roof or the ground spot, the ducts and the electrical panel. Nothing to sign.

Your file
0 of 5

With these photos, the technician arrives prepared: the right roof support, the right electrical supply, the right connections.

12 · Quiz

Five questions to see what you remember.

One answer per question; the explanation shows right away.

1
Where does the refrigerant in a packaged unit circulate?
2
Which systems does the LogisVert guide 1.10 name?
3
Down to what temperature does the Rooftop R32 heat, per its spec sheet?
4
Which of these refrigerants has the lowest GWP?
5
What does an ERV air exchanger transfer?
Your score
0 / 5

5 questions left

1
Where does the refrigerant in a packaged unit circulate?
2
Which systems does the LogisVert guide 1.10 name?
3
Down to what temperature does the Rooftop R32 heat, per its spec sheet?
4
Which of these refrigerants has the lowest GWP?
5
What does an ERV air exchanger transfer?
Your score
0 / 5

5 questions left

13 · FAQ

Your questions about packaged heat pumps

Search a word: permit, refrigerant, rebate, price…

A single outdoor unit that holds everything: compressor, two coils, fan and blower. It connects to the home’s ductwork. No refrigerant line enters the building.

Why AirGreen

One roof, one plan, one price. Before the first bolt.

One visit, one written offer, installation and after-sales service by the same team. The in-home estimate is free.

South Shore: showroom at 1370 Joliot-Curie Street, unit 712, Boucherville · 514 316-3007. Monday to Thursday 8 a.m. to 6 p.m., Friday 8 a.m. to 4 p.m.
AirGreen in 52 seconds: the team, the installations, the showroom
Why AirGreen

One roof, one plan, one price. Before the first bolt.

One visit, one written offer, installation and after-sales service by the same team. The in-home estimate is free.

South Shore: showroom at 1370 Joliot-Curie Street, unit 712, Boucherville · 514 316-3007. Monday to Thursday 8 a.m. to 6 p.m., Friday 8 a.m. to 4 p.m.
AirGreen in 52 seconds: the team, the installations, the showroom
RBQ licence: 5645-9605-01
15.8 Ventilation · 15.10 Refrigeration · 16 Electrical
CMEQ member
Corporation of master electricians of Québec
$5M insurance
Civil liability, from start to finish
Final offer first
Always in writing, before work begins
Hydro-Québec never solicits by phone or door-to-door for LogisVert.
Sources checked on September 30, 2026
  • AirGreen catalogue, Shopify product sheets (139 packaged units, 256 air exchangers), read on September 30, 2026.
  • Hydro-Québec, LogisVert, Participation guide, residential customers, version 1.10 of September 15, 2026.
  • Gree, Tosot and Kinghome Rooftop R32 sheets (AHRI 216763049, 215866830, 216763053, 215866831) and Midea EVOX G3 (AHRI 215471340, 215471343, 215471344, 215471345).
  • GWP (IPCC AR4) published by manufacturers: Johnson Controls (York), R-454B white paper, August 2023; Lennox and LG for R-32 and R-410A.
  • AirGreen, Permits and regulations (194 municipalities), checked on September 30, 2026.
Amounts shown are estimates; only the responsible agencies confirm the assistance granted. Capacities and performance: manufacturer spec sheets.