AirGreenGOODMAN
GOODMAN · Series 19 · Series 21 · GLZS4B · GLZS4MThe GOODMAN space at AirGreenSold and installed by AirGreen. Montreal, Laval, Longueuil, the South Shore and the North Shore.
All of GOODMAN

GOODMAN//Packaged units

Goodman packaged heat pump: horizontal (H41) or multi-position (M41)

The GPH16 is a packaged heat pump: everything sits in one outdoor cabinet, down to the duct blower. GOODMAN published it in two R-410A series, from 2 to 5 tons: the H41, horizontal, and the M41, multi-position, which converts to downflow; GOODMAN's website no longer listed it on November 5, 2026. Its 2018 and 2020 spec sheets give the heat output down to -23.3 °C.

The question this page answersHorizontal or multi-position: which Goodman packaged unit fits my site?

-23.3 °Clast published heating point (-10 °F), for both H41 and M41Source 1, p. 21-22; source 2, p. 20-21
2-stagescroll compressor on all six M41 units, 2 to 5 tonsSource 1, p. 1 and 3
13.0highest published EER, H41 at 2 and 3 tonsSource 2, p. 3
8.2top HSPF claimed for both seriesSource 3

Packaged units in our store

Six sizes of H41 and six of M41, all quoted on request. The product title tells them apart: "Horizontal" marks the H41. The "16 SEER" in the titles is the series maximum: GOODMAN's sheets give 15.5 for the 2.5-ton M41 and the 5-ton H41.

12 models in our store

Tool//Horizontal or multi-position

Horizontal or multi-position: the model and its heat down to -23.3 °C

Choose how the ducts connect to the unit, then pick the size. The tool gives the GOODMAN model that fits, its published figures and its heat output at five outdoor temperatures.

GPH16 packaged unit, H41 and M41Source 1, p. 3 and 21-22; source 2, p. 3 and 20-21
Duct connection
Size (tons)

GPH1636H41 · 3 tons

Horizontal only · SS-GPH16H sheet of July 2018

Cooling
36,000 BTU/h
SEER / EER
16.0 / 13.0
Heat at 8.3 °C (47 °F)
32,200 BTU/hCOP 3.8
Heat at -8.3 °C (17 °F)
20,400 BTU/hCOP 2.4
HSPF
8.0
Scroll compressor
single-stage
Sound (dB, as printed)
78
Min. circuit ampacity / max. fuse
27.0 / 40 A
Shipping weight
387 lb
8.3 °C (47 °F)32,200 BTU/h
-8.3 °C (17 °F)20,400 BTU/h
-15 °C (5 °F)15,600 BTU/h
-17.8 °C (0 °F)13,600 BTU/h
-23.3 °C (-10 °F)9,500 BTU/h

Specifications tableExpanded heating tables

Horizontal only. GOODMAN gives the H41 a single installation option: horizontal.

GOODMAN's GPH16 tables stop at -10 °F (-23.3 °C).

See the GPH1636H41 product

Version A of each model. Every bar reads against the heat at 8.3 °C: dark, values from the specifications table; teal, expanded heating tables at nominal airflow. Sound: printed as "Decibels", no weighting or test condition given.

AirGreen × GOODMAN//The installation

Horizontal or downflow: where the air enters the house

A packaged unit needs nothing indoors except the air ducts and the thermostat. It all comes down to the duct connection.

Horizontal: from the side

The supply and return ducts connect on the side of the unit, then go through the wall or the foundation.

The H41 is built for this: GOODMAN describes it as a horizontal-discharge unit (source 2, p. 1). The M41 can be set up this way too.

Downflow: from underneath

The air leaves through the bottom of the unit, into ducts placed below it.

Only the M41 converts this way: GOODMAN calls it convertible to horizontal or downflow (source 1, p. 1). Its brochure gives the H41 the horizontal option only (source 3).

The blower is outdoors too

The ECM motor that pushes air through the ducts sits in the cabinet, with the compressor (source 1, p. 3; source 2, p. 1). GOODMAN presents the GPH16 as a self-contained unit (source 3).

No air handler to fit in the basement or a closet.

GOODMAN//Specifications

The twelve models, line by line

Values from the two GOODMAN spec sheets, version A of each size.

GOODMAN data, sources 1 and 2

H41 horizontal, SS-GPH16H sheet of July 2018, version A
Published value2 t2.5 t3 t3.5 t4 t5 t
ModelGPH1624H41GPH1630H41GPH1636H41GPH1642H41GPH1648H41GPH1660H41
Cooling24,000 BTU/h28,400 BTU/h36,000 BTU/h42,000 BTU/h46,000 BTU/h57,500 BTU/h
SEER / EER16.0 / 13.016.0 / 12.516.0 / 13.016.0 / 12.016.0 / 12.015.5 / 12.0
Heat at 8.3 °C (47 °F), COP22,800 BTU/h, 3.827,600 BTU/h, 3.832,200 BTU/h, 3.840,000 BTU/h, 3.844,000 BTU/h, 3.854,500 BTU/h, 3.6
Heat at -8.3 °C (17 °F), COP13,000 BTU/h, 2.415,400 BTU/h, 2.520,400 BTU/h, 2.421,600 BTU/h, 2.426,000 BTU/h, 2.433,800 BTU/h, 2.4
HSPF8.08.08.08.08.08.2
Heat at -23.3 °C (-10 °F), COP6,100 BTU/h, 1.297,200 BTU/h, 1.289,500 BTU/h, 1.3510,100 BTU/h, 1.2712,100 BTU/h, 1.3115,000 BTU/h, 1.31
Scroll compressorsingle-stagesingle-stagesingle-stagesingle-stagetwo-stagetwo-stage
Sound (dB, as printed)767678788080
Min. circuit ampacity / max. fuse21.0 / 30 A23.0 / 35 A27.0 / 40 A28.0 / 45 A35.0 / 50 A40.0 / 60 A
R-410A charge116 oz116 oz170 oz170 oz170 oz175 oz
Shipping weight324 lb324 lb387 lb387 lb412 lb417 lb
M41 multi-position, SS-GPH16M sheet of December 2020, version A
Published value2 t2.5 t3 t3.5 t4 t5 t
ModelGPH1624M41GPH1630M41GPH1636M41GPH1642M41GPH1648M41GPH1660M41
Cooling24,000 BTU/h29,000 BTU/h33,600 BTU/h41,000 BTU/h47,000 BTU/h58,000 BTU/h
SEER / EER16.0 / 12.515.5 / 12.016.0 / 12.016.0 / 12.016.0 / 12.016.0 / 12.0
Heat at 8.3 °C (47 °F), COP22,800 BTU/h, 3.628,400 BTU/h, 3.533,600 BTU/h, 3.638,000 BTU/h, 3.645,500 BTU/h, 3.755,000 BTU/h, 3.8
Heat at -8.3 °C (17 °F), COP12,500 BTU/h, 2.316,600 BTU/h, 2.419,400 BTU/h, 2.421,600 BTU/h, 2.327,000 BTU/h, 2.430,000 BTU/h, 2.4
HSPF8.08.08.28.28.28.2
Heat at -23.3 °C (-10 °F), COP5,800 BTU/h, 1.257,800 BTU/h, 1.249,100 BTU/h, 1.3110,000 BTU/h, 1.2312,600 BTU/h, 1.3414,300 BTU/h, 1.29
Scroll compressortwo-stagetwo-stagetwo-stagetwo-stagetwo-stagetwo-stage
Sound (dB, as printed)767676787878
Min. circuit ampacity / max. fuse20.4 / 30 A22.2 / 35 A24.6 / 40 A29.6 / 45 A33.7 / 50 A42.5 / 60 A
R-410A charge137 oz137 oz137 oz170 oz170 oz240 oz
Shipping weight376 lb385 lb438 lb492 lb490 lb612 lb

Compare//Same capacity

H41 or M41, at 5 tons

At 5 tons, both series deliver almost the same heat at 8.3 °C. The H41 keeps more of it at -8.3 °C and weighs 195 lb less; the M41 also installs in downflow, and its sheet prints 2 dB less.

H41GPH1660H41, version A
M41GPH1660M41, version A
At 5 tonsH41M41
Installationhorizontalhorizontal or downflow
Scroll compressortwo-stagetwo-stage
Cooling57,500 BTU/h58,000 BTU/h
SEER / EER15.5 / 12.016.0 / 12.0
Heat at 8.3 °C (47 °F)54,500 BTU/h55,000 BTU/h
Heat at -8.3 °C (17 °F)33,800 BTU/h30,000 BTU/h
Heat at -23.3 °C (-10 °F)15,000 BTU/h14,300 BTU/h
HSPF8.28.2
Sound (dB, as printed)8078
R-410A charge175 oz240 oz
Shipping weight417 lb612 lb
Min. circuit ampacity / max. fuse40.0 / 60 A42.5 / 60 A

Source 1, p. 3 and 22; source 2, p. 3 and 21. Two reading choices: the H41 sheet labels the fuse line "Min. Overcurrent Protection", the M41 sheet "Max."; we read both as the maximum fuse, which the H41 sheet's note confirms (time-delay fuse or HACR breaker of the size shown). The brochure says the GPH16 is designed for multi-position installation, but its own table gives the H41 the horizontal option only: we follow the table.

Did you know//GPH16 sheets

What the GPH16 sheets hide in their columns

01

A kit worth 0.2 HSPF

On the 2 and 2.5-ton M41, the OTHPPKG outdoor thermostat kit lifts the published HSPF from 8.0 to 8.2, according to the December 2020 M41 sheet.

Source 1, p. 1 and 3
02

Two versions of some sizes

The 2018 H41 sheet lists two 3.5-ton units: the B has a two-stage compressor and 8.2 HSPF, the A a single stage and 8.0. The 2020 M41 sheet lists two 5-ton units: the B weighs 688 lb and needs a 70 A fuse, versus 612 lb and 60 A for the A.

Source 2, p. 3; source 1, p. 3
03

A COP of 1.23 to 1.35 at -23.3 °C

At -10 °F, the last published point, all twelve version A models keep a COP of 1.23 to 1.35, which means 23 to 35% more heat than the electricity they use.

Source 1, p. 21-22; source 2, p. 20-21

AirGreen × GOODMAN//Who brings what

Everything in one cabinet, except the installation

GOODMANWhat GOODMAN brings

  • Two R-410A series from 2 to 5 tons: the horizontal H41 and the multi-position M41
  • A scroll compressor, two-stage on all six M41 units
  • Published heat from 8.3 to -23.3 °C, size by size
  • The duct blower, with an ECM motor, inside the cabinet

Questions//Packaged units

Questions about Goodman packaged units

H41 or M41, when both can go horizontal?

In version A, at the same size, the H41 is always lighter. The M41 has a two-stage compressor at every size; the H41 only at 4 and 5 tons (its 3.5-ton B is two-stage too). The rest depends on the size: at 3 tons, the H41 cools 36,000 BTU/h with an EER of 13.0, the M41 33,600 BTU/h with 12.0.

Do you need backup heat with a GPH16?

Yes. The 3-ton H41 drops from 32,200 BTU/h at 8.3 °C to 9,500 BTU/h at -23.3 °C, the last published point. Backup heat takes over as soon as the house needs more, well before -23.3 °C; its size is set on site.

Does a Goodman packaged unit qualify for LogisVert?

No. Since November 26, 2025, Hydro-Québec requires an ENERGY STAR certified heat pump. The ENERGY STAR list read on November 5, 2026 holds no GPH16, and GOODMAN says so itself in its M41 sheet: the ENERGY STAR row reads "NO".

The sheets date from 2018 and 2020: are they still current?

They are the latest we found for these models: the H41 sheet of July 2018, the M41 sheet of December 2020, the brochure of February 2020. On November 5, 2026, GOODMAN's website no longer listed the GPH16 among its packaged units. These figures are the ones GOODMAN published for the GPH16; the exact model is confirmed with the quote.

What circuit does a GPH16 packaged unit need?

In version A, depending on series and size, the minimum circuit ampacity runs from 20.4 to 42.5 A and the maximum fuse from 30 to 60 A, according to the specification tables of the H41 and M41 sheets. The voltage and the capacity of the electrical service are checked on site.

Read next//The GOODMAN space

Related pages

AirGreen

Your Goodman packaged unit: we start with where it will sit

We look at where the unit will sit, where the air ducts will enter the house and what the electrical service can supply. The choice between H41 and M41 follows, then the size.

Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.

Free on-site estimate

An AirGreen technician assesses the heating and cooling needs, where the units will go and the refrigerant line route on site before proposing a model.

RBQ licence 5645-9605-01

Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.

The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.

Sources

  1. GOODMAN, "GPH16M High-Efficiency Packaged Heat Pump", spec sheet SS-GPH16M, 12/20 (supersedes 10/20), p. 1, 3, 21 and 22, read November 11, 2026. apps.goodmanmfg.com
  2. GOODMAN, "High-Efficiency Packaged Heat Pump, 2 to 5 Tons" (GPH16 H41), spec sheet SS-GPH16H, 07/18 (supersedes 6/18), p. 1, 3, 20 and 21, read November 11, 2026. Copy hosted outside GOODMAN's servers.
  3. GOODMAN, brochure "GPH16H and GPH16M Packaged Heat Pumps", code CB-GPH16 2-20, model table and features, read November 11, 2026. apps.goodmanmfg.com
  4. GOODMAN, goodmanmfg.com, packaged heat pump listing, checked November 5, 2026: no GPH16.
  5. ENERGY STAR, certified heat pumps (dataset w7cv-9xjt), Canadian market, read November 5, 2026: no GPH16 system. energystar.gov
  6. Hydro-Québec, "LogisVert Efficient Homes Program – ENERGY STAR® Heat Pump", partner notice of September 25, 2025 (required from November 26, 2025). hydroquebec.com

Read and dated by AirGreen. Capacities and limits are the ones GOODMAN publishes; a real installation can give other values.