GOODMAN//Packaged units
Goodman packaged heat pump: horizontal (H41) or multi-position (M41)
The GPH16 is a packaged heat pump: everything sits in one outdoor cabinet, down to the duct blower. GOODMAN published it in two R-410A series, from 2 to 5 tons: the H41, horizontal, and the M41, multi-position, which converts to downflow; GOODMAN's website no longer listed it on November 5, 2026. Its 2018 and 2020 spec sheets give the heat output down to -23.3 °C.
The question this page answersHorizontal or multi-position: which Goodman packaged unit fits my site?
Packaged units in our store
Six sizes of H41 and six of M41, all quoted on request. The product title tells them apart: "Horizontal" marks the H41. The "16 SEER" in the titles is the series maximum: GOODMAN's sheets give 15.5 for the 2.5-ton M41 and the 5-ton H41.
Tool//Horizontal or multi-position
Horizontal or multi-position: the model and its heat down to -23.3 °C
Choose how the ducts connect to the unit, then pick the size. The tool gives the GOODMAN model that fits, its published figures and its heat output at five outdoor temperatures.
GPH1636H41 · 3 tons
Horizontal only · SS-GPH16H sheet of July 2018
- Cooling
- 36,000 BTU/h
- SEER / EER
- 16.0 / 13.0
- Heat at 8.3 °C (47 °F)
- 32,200 BTU/hCOP 3.8
- Heat at -8.3 °C (17 °F)
- 20,400 BTU/hCOP 2.4
- HSPF
- 8.0
- Scroll compressor
- single-stage
- Sound (dB, as printed)
- 78
- Min. circuit ampacity / max. fuse
- 27.0 / 40 A
- Shipping weight
- 387 lb
Specifications tableExpanded heating tables
Horizontal only. GOODMAN gives the H41 a single installation option: horizontal.
GOODMAN's GPH16 tables stop at -10 °F (-23.3 °C).
See the GPH1636H41 productVersion A of each model. Every bar reads against the heat at 8.3 °C: dark, values from the specifications table; teal, expanded heating tables at nominal airflow. Sound: printed as "Decibels", no weighting or test condition given.
AirGreen × GOODMAN//The installation
Horizontal or downflow: where the air enters the house
A packaged unit needs nothing indoors except the air ducts and the thermostat. It all comes down to the duct connection.
Horizontal: from the side
The supply and return ducts connect on the side of the unit, then go through the wall or the foundation.
The H41 is built for this: GOODMAN describes it as a horizontal-discharge unit (source 2, p. 1). The M41 can be set up this way too.
Downflow: from underneath
The air leaves through the bottom of the unit, into ducts placed below it.
Only the M41 converts this way: GOODMAN calls it convertible to horizontal or downflow (source 1, p. 1). Its brochure gives the H41 the horizontal option only (source 3).
The blower is outdoors too
The ECM motor that pushes air through the ducts sits in the cabinet, with the compressor (source 1, p. 3; source 2, p. 1). GOODMAN presents the GPH16 as a self-contained unit (source 3).
No air handler to fit in the basement or a closet.
GOODMAN//Specifications
The twelve models, line by line
Values from the two GOODMAN spec sheets, version A of each size.
GOODMAN data, sources 1 and 2
| Published value | 2 t | 2.5 t | 3 t | 3.5 t | 4 t | 5 t |
|---|---|---|---|---|---|---|
| Model | GPH1624H41 | GPH1630H41 | GPH1636H41 | GPH1642H41 | GPH1648H41 | GPH1660H41 |
| Cooling | 24,000 BTU/h | 28,400 BTU/h | 36,000 BTU/h | 42,000 BTU/h | 46,000 BTU/h | 57,500 BTU/h |
| SEER / EER | 16.0 / 13.0 | 16.0 / 12.5 | 16.0 / 13.0 | 16.0 / 12.0 | 16.0 / 12.0 | 15.5 / 12.0 |
| Heat at 8.3 °C (47 °F), COP | 22,800 BTU/h, 3.8 | 27,600 BTU/h, 3.8 | 32,200 BTU/h, 3.8 | 40,000 BTU/h, 3.8 | 44,000 BTU/h, 3.8 | 54,500 BTU/h, 3.6 |
| Heat at -8.3 °C (17 °F), COP | 13,000 BTU/h, 2.4 | 15,400 BTU/h, 2.5 | 20,400 BTU/h, 2.4 | 21,600 BTU/h, 2.4 | 26,000 BTU/h, 2.4 | 33,800 BTU/h, 2.4 |
| HSPF | 8.0 | 8.0 | 8.0 | 8.0 | 8.0 | 8.2 |
| Heat at -23.3 °C (-10 °F), COP | 6,100 BTU/h, 1.29 | 7,200 BTU/h, 1.28 | 9,500 BTU/h, 1.35 | 10,100 BTU/h, 1.27 | 12,100 BTU/h, 1.31 | 15,000 BTU/h, 1.31 |
| Scroll compressor | single-stage | single-stage | single-stage | single-stage | two-stage | two-stage |
| Sound (dB, as printed) | 76 | 76 | 78 | 78 | 80 | 80 |
| Min. circuit ampacity / max. fuse | 21.0 / 30 A | 23.0 / 35 A | 27.0 / 40 A | 28.0 / 45 A | 35.0 / 50 A | 40.0 / 60 A |
| R-410A charge | 116 oz | 116 oz | 170 oz | 170 oz | 170 oz | 175 oz |
| Shipping weight | 324 lb | 324 lb | 387 lb | 387 lb | 412 lb | 417 lb |
| Published value | 2 t | 2.5 t | 3 t | 3.5 t | 4 t | 5 t |
|---|---|---|---|---|---|---|
| Model | GPH1624M41 | GPH1630M41 | GPH1636M41 | GPH1642M41 | GPH1648M41 | GPH1660M41 |
| Cooling | 24,000 BTU/h | 29,000 BTU/h | 33,600 BTU/h | 41,000 BTU/h | 47,000 BTU/h | 58,000 BTU/h |
| SEER / EER | 16.0 / 12.5 | 15.5 / 12.0 | 16.0 / 12.0 | 16.0 / 12.0 | 16.0 / 12.0 | 16.0 / 12.0 |
| Heat at 8.3 °C (47 °F), COP | 22,800 BTU/h, 3.6 | 28,400 BTU/h, 3.5 | 33,600 BTU/h, 3.6 | 38,000 BTU/h, 3.6 | 45,500 BTU/h, 3.7 | 55,000 BTU/h, 3.8 |
| Heat at -8.3 °C (17 °F), COP | 12,500 BTU/h, 2.3 | 16,600 BTU/h, 2.4 | 19,400 BTU/h, 2.4 | 21,600 BTU/h, 2.3 | 27,000 BTU/h, 2.4 | 30,000 BTU/h, 2.4 |
| HSPF | 8.0 | 8.0 | 8.2 | 8.2 | 8.2 | 8.2 |
| Heat at -23.3 °C (-10 °F), COP | 5,800 BTU/h, 1.25 | 7,800 BTU/h, 1.24 | 9,100 BTU/h, 1.31 | 10,000 BTU/h, 1.23 | 12,600 BTU/h, 1.34 | 14,300 BTU/h, 1.29 |
| Scroll compressor | two-stage | two-stage | two-stage | two-stage | two-stage | two-stage |
| Sound (dB, as printed) | 76 | 76 | 76 | 78 | 78 | 78 |
| Min. circuit ampacity / max. fuse | 20.4 / 30 A | 22.2 / 35 A | 24.6 / 40 A | 29.6 / 45 A | 33.7 / 50 A | 42.5 / 60 A |
| R-410A charge | 137 oz | 137 oz | 137 oz | 170 oz | 170 oz | 240 oz |
| Shipping weight | 376 lb | 385 lb | 438 lb | 492 lb | 490 lb | 612 lb |
Compare//Same capacity
H41 or M41, at 5 tons
At 5 tons, both series deliver almost the same heat at 8.3 °C. The H41 keeps more of it at -8.3 °C and weighs 195 lb less; the M41 also installs in downflow, and its sheet prints 2 dB less.
| At 5 tons | H41 | M41 |
|---|---|---|
| Installation | horizontal | horizontal or downflow |
| Scroll compressor | two-stage | two-stage |
| Cooling | 57,500 BTU/h | 58,000 BTU/h |
| SEER / EER | 15.5 / 12.0 | 16.0 / 12.0 |
| Heat at 8.3 °C (47 °F) | 54,500 BTU/h | 55,000 BTU/h |
| Heat at -8.3 °C (17 °F) | 33,800 BTU/h | 30,000 BTU/h |
| Heat at -23.3 °C (-10 °F) | 15,000 BTU/h | 14,300 BTU/h |
| HSPF | 8.2 | 8.2 |
| Sound (dB, as printed) | 80 | 78 |
| R-410A charge | 175 oz | 240 oz |
| Shipping weight | 417 lb | 612 lb |
| Min. circuit ampacity / max. fuse | 40.0 / 60 A | 42.5 / 60 A |
Source 1, p. 3 and 22; source 2, p. 3 and 21. Two reading choices: the H41 sheet labels the fuse line "Min. Overcurrent Protection", the M41 sheet "Max."; we read both as the maximum fuse, which the H41 sheet's note confirms (time-delay fuse or HACR breaker of the size shown). The brochure says the GPH16 is designed for multi-position installation, but its own table gives the H41 the horizontal option only: we follow the table.
Did you know//GPH16 sheets
What the GPH16 sheets hide in their columns
A kit worth 0.2 HSPF
On the 2 and 2.5-ton M41, the OTHPPKG outdoor thermostat kit lifts the published HSPF from 8.0 to 8.2, according to the December 2020 M41 sheet.
Source 1, p. 1 and 3Two versions of some sizes
The 2018 H41 sheet lists two 3.5-ton units: the B has a two-stage compressor and 8.2 HSPF, the A a single stage and 8.0. The 2020 M41 sheet lists two 5-ton units: the B weighs 688 lb and needs a 70 A fuse, versus 612 lb and 60 A for the A.
Source 2, p. 3; source 1, p. 3A COP of 1.23 to 1.35 at -23.3 °C
At -10 °F, the last published point, all twelve version A models keep a COP of 1.23 to 1.35, which means 23 to 35% more heat than the electricity they use.
Source 1, p. 21-22; source 2, p. 20-21AirGreen × GOODMAN//Who brings what
Everything in one cabinet, except the installation
What GOODMAN brings
- Two R-410A series from 2 to 5 tons: the horizontal H41 and the multi-position M41
- A scroll compressor, two-stage on all six M41 units
- Published heat from 8.3 to -23.3 °C, size by size
- The duct blower, with an ECM motor, inside the cabinet
What AirGreen brings
- Choosing between H41 and M41 from the duct connection
- Installation by our refrigeration technicians, under AirGreen's RBQ licence 5645-9605-01
- Choosing the backup heat, electric element or other source, from the on-site assessment
- A straight answer on LogisVert: the GPH16 does not qualify
Questions//Packaged units
Questions about Goodman packaged units
H41 or M41, when both can go horizontal?
In version A, at the same size, the H41 is always lighter. The M41 has a two-stage compressor at every size; the H41 only at 4 and 5 tons (its 3.5-ton B is two-stage too). The rest depends on the size: at 3 tons, the H41 cools 36,000 BTU/h with an EER of 13.0, the M41 33,600 BTU/h with 12.0.
Do you need backup heat with a GPH16?
Yes. The 3-ton H41 drops from 32,200 BTU/h at 8.3 °C to 9,500 BTU/h at -23.3 °C, the last published point. Backup heat takes over as soon as the house needs more, well before -23.3 °C; its size is set on site.
Does a Goodman packaged unit qualify for LogisVert?
No. Since November 26, 2025, Hydro-Québec requires an ENERGY STAR certified heat pump. The ENERGY STAR list read on November 5, 2026 holds no GPH16, and GOODMAN says so itself in its M41 sheet: the ENERGY STAR row reads "NO".
The sheets date from 2018 and 2020: are they still current?
They are the latest we found for these models: the H41 sheet of July 2018, the M41 sheet of December 2020, the brochure of February 2020. On November 5, 2026, GOODMAN's website no longer listed the GPH16 among its packaged units. These figures are the ones GOODMAN published for the GPH16; the exact model is confirmed with the quote.
What circuit does a GPH16 packaged unit need?
In version A, depending on series and size, the minimum circuit ampacity runs from 20.4 to 42.5 A and the maximum fuse from 30 to 60 A, according to the specification tables of the H41 and M41 sheets. The voltage and the capacity of the electrical service are checked on site.
Read next//The GOODMAN space
Related pages
Your Goodman packaged unit: we start with where it will sit
We look at where the unit will sit, where the air ducts will enter the house and what the electrical service can supply. The choice between H41 and M41 follows, then the size.
Sold and installed by AirGreen.Montreal, Laval, Longueuil, the South Shore and the North Shore.
An AirGreen technician assesses the heating and cooling needs, where the units will go and the refrigerant line route on site before proposing a model.
Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a partner holding the required licence.
The equipment is GOODMAN-branded. AirGreen sells it, installs it and services it across Greater Montreal.
Sources
- GOODMAN, "GPH16M High-Efficiency Packaged Heat Pump", spec sheet SS-GPH16M, 12/20 (supersedes 10/20), p. 1, 3, 21 and 22, read November 11, 2026. apps.goodmanmfg.com
- GOODMAN, "High-Efficiency Packaged Heat Pump, 2 to 5 Tons" (GPH16 H41), spec sheet SS-GPH16H, 07/18 (supersedes 6/18), p. 1, 3, 20 and 21, read November 11, 2026. Copy hosted outside GOODMAN's servers.
- GOODMAN, brochure "GPH16H and GPH16M Packaged Heat Pumps", code CB-GPH16 2-20, model table and features, read November 11, 2026. apps.goodmanmfg.com
- GOODMAN, goodmanmfg.com, packaged heat pump listing, checked November 5, 2026: no GPH16.
- ENERGY STAR, certified heat pumps (dataset w7cv-9xjt), Canadian market, read November 5, 2026: no GPH16 system. energystar.gov
- Hydro-Québec, "LogisVert Efficient Homes Program – ENERGY STAR® Heat Pump", partner notice of September 25, 2025 (required from November 26, 2025). hydroquebec.com
Read and dated by AirGreen. Capacities and limits are the ones GOODMAN publishes; a real installation can give other values.