Free on-site estimate
Commercial HVAC · Greater Montréal · Updated October 14, 2026

Commercial HVAC system design and installation in Montréal

Offices, stores, restaurants, hotels, warehouses and plants: we design, install, test and maintain your heat pumps, VRF systems, ventilation and refrigeration in Montréal, Laval, Longueuil, the North Shore and the South Shore.

Tap a zone of the building

Offices

RBQ 15.10 · 15.8

What goes here: cassettes, concealed ducted units or heat-recovery VRF.

Our work: one set point per zone, central controls.

Watch for: cassettes and ducted units need a drop ceiling.
15.8 · 15.10 · 16Ventilation, refrigeration and electrical under one RBQ licence: 5645-9605-01.
up to 90%of eligible costs paid by Hydro-Québec on Rate G. 75% on other business rates.
24 hto receive the detailed quote after the on-site visit.
$5Mliability insurance
5 regionsMontréal, Laval, Longueuil, North Shore, South Shore
Bouchervilleshowroom, 514 316-3007
Mon. to Fri.8 a.m. to 6 p.m., Friday until 4 p.m.
01 · Why design matters

A well-designed HVAC system pays off every day: comfort, air, energy and costs.

A well-designed, properly installed commercial HVAC system sets your building’s comfort, air quality, energy efficiency and operating costs. Sized to your needs, it lasts longer and breaks down less often.

Commercial HVAC system design: reading the plans in a mechanical room
Design starts on site: building size, occupancy, insulation and Montréal’s climate.
ComfortSteady temperature in every zone, without drafts.
Air qualityFresh air and filtration matched to real occupancy.
Energy efficiencyThe right unit, at the right capacity, in the right place.
Operating costsLess energy, fewer service calls.
PerformanceTesting and balancing before handover.
Lifespan and reliabilityA system sized to the building works less hard and lasts longer.

Heat delivered for the same electricity, in winter

Electric baseboards equal 1. According to Hydro-Québec, a heat pump can reach up to 3.

Source: Hydro-Québec, heat pumps for businesses. Actual gains depend on the unit, its capacity and the outdoor temperature.

02 · Our design and installation services

Four services, one point of contact, from the first visit to maintenance.

We provide complete design and installation services so your system runs at peak efficiency, then we keep it that way.

01

System design

Building analysis: size, occupancy, insulation and local climate. Then a system fitted to your needs and budget.

  • Load needs by zone
  • System and equipment selection
  • Duct and line layout

You get: a detailed proposal, or our data sheets for the project engineer.

02

System installation

Our refrigeration technicians integrate the system into your building: roof, ceilings, ducts, electrical panel.

  • Heat pumps, VRF, AC (15.10)
  • Ducts and ventilation (15.8)
  • Electrical supply (16)

You get: a clean, compliant installation and one point of contact.

03

Performance testing

After installation, we test and fine-tune until the system delivers the planned comfort and savings.

  • Operating tests
  • Set-point and airflow balancing
  • Controls check

You get: a commissioning report.

04

Post-installation support

Our team stays with you: preventive maintenance and service to keep the system efficient for its whole life.

  • Scheduled preventive maintenance
  • Service calls
  • Manufacturer warranty

See preventive maintenance

The process, step by step

STEP 01

Free visit

Building, roof, electrical panel and plans, at no cost.

AirGreen
STEP 02

Survey and needs

Zones, occupancy hours, fresh air, existing equipment, Hydro-Québec rate.

AirGreen and you
STEP 03

Design

Non-industrial Part 9: we design. Otherwise, the engineer signs the plans.

AirGreen or engineer
STEP 04

Quote in 24 h

Models, quantities and prices line by line, within 24 hours of the visit.

AirGreen
STEP 05

Installation

Refrigerant, ducts, ventilation and electrical: RBQ 15.8, 15.10 and 16.

AirGreen
STEP 06

Testing and commissioning

Tests, set-point and airflow adjustments, controls checked.

AirGreen
STEP 07

Handover file

Spec sheets and French invoices, ready for Hydro-Québec.

You
03 · Your project sheet

Five answers, and your project takes shape.

Each answer updates the sheet: engineer or not, systems to consider, Hydro-Québec support, who does what. Nothing is sent: copy the sheet and attach it to your request.

Q1What building?
Q2How many storeys?
Q3Building area?

Building area is the largest horizontal area above ground, measured to the outside faces of the walls.

Q4What matters to you (several choices)
Q5Rate on your Hydro-Québec bill

The rate is shown in the “Electricity cost details” section of your bill.

04 · A tailored approach

Every commercial building is unique. Pick yours.

Offices in Montréal, retail in Laval, a plant in Longueuil, a hotel on the North or South Shore: we start from your needs, expectations and constraints.

What we install

A busy office space in Montréal

  • Heat-recovery VRF for several tenants
  • Ceiling cassettes or ducted units
  • HRV or ERV air exchanger
Design
It depends on sizeAt most 3 storeys and 600 m²: we can design with the Part 9 solutions. Beyond that: plans signed and sealed by an engineer.
Learn more

Several tenants on one system? A heat-recovery VRF can heat one zone and cool another at the same time.

Commercial air conditioning
05 · Compare the systems

Eight systems. Tell us your constraint, we light up the ones that fit.

A qualitative comparison: size and number of units come from the calculation done for your building.

Pick a constraint to highlight the systems that fit.

Wall or multi-zone

ZonesPer room
DuctsNone
Fresh airNo, add an HRV

Small offices, units, separate rooms.

See the units

Ceiling cassette

ZonesPer unit
DuctsNone
Fresh airNo, add an HRV

Stores, offices, dining rooms.

See the units

Concealed ducted

ZonesPer unit
DuctsShort
Fresh airNo, add an HRV

Offices and shops where the unit must disappear.

See the units

Central heat pump

ZonesOne per system
DuctsFull network
Fresh airVia connected HRV

Open areas with existing ducts.

See the units

Packaged unit

ZonesOne per unit
DuctsDepends on model
Fresh airDepends on model

Everything in one cabinet, when indoor space is short.

See the units

VRF

ZonesMany on one system
DuctsOptional
Fresh airNo, add an HRV

Offices, hotels, schools, large buildings (Hydro-Québec).

See the units

PTAC

ZonesPer room
DuctsNone, through-wall
Fresh airDepends on model

Hotels, residences, apartments.

See the units

HRV or ERV air exchanger

ZonesWhole building
DuctsYes
Fresh airYes, that’s its job

Brings in fresh air and recovers heat from exhaust air. Does not heat or cool.

See the units
06 · With or without an engineer

The law decides who designs. We work either way.

Since Québec’s Engineers Act was modernized in 2020, the value of the work no longer matters: the building’s use, height and area do.

3At most 3 storeysBuilding area: 600 m² at mostOffices, retail, housingPart 9 of the code
Part 9 · non-industrial

We design

Offices, stores or housing of at most 3 storeys and 600 m², designed with the complete acceptable solutions of Part 9 of the code.

Part 3 · industrial · Groups A and B

The engineer signs, we install

Over 3 storeys or 600 m², restaurant, school, care, warehouse, shop or plant: plans and specs signed and sealed by an engineer.

Section 24

No unsealed plans

For a covered work, no one may use a plan or specification that is not signed and sealed by an engineer.

Check my building
07 · Who does what

Every part of the job has its licence. Check them before you sign.

Pick the work in your project: we show what the law requires and what we do ourselves.

WorkWhat the law requiresWho does it
Heat pumps, AC, VRFRBQ 15.10, with 15.8 for forced-air systemsAirGreen
Ducts, ventilation, HRVRBQ 15.8 VentilationAirGreen
Equipment wiringRBQ 16 ElectricalAirGreen
Refrigerant handlingTechnician’s environmental certificate HAirGreen

Any licence can be checked for free in the Régie du bâtiment du Québec licence-holder register.

08 · Hydro-Québec support

How much Hydro-Québec can pay, and when.

Efficient Solutions program: support is the lowest of three amounts: the OSE tool’s calculation, the maximum percentage of your eligible costs, and $5 M.

AYour electricity rate
$

Eligible costs: new equipment, installation and start-up, before taxes.

This request comes after your file is checked, once the equipment is installed and running.

What businesses have received

Source: Hydro-Québec, commercial market project examples (viewed October 14, 2026). Real projects published by Hydro-Québec, calculated under the rules in force at the time.

All about Efficient Solutions, Small Business stream

09 · Refrigerants and rules

R-410A, R-32, certificates: what’s true today.

Manufacturers are moving to A2L refrigerants such as R-32. Here are the numbers, then six common beliefs to test.

Global warming potential of refrigerants

Relative to CO₂, which equals 1.

Limit of 750 for new chillers since January 1, 2025.

Sources: MELCCFP, potentials of the main halocarbons; R-410A calculated from its two components (R-32 and R-125, in equal parts); SOR/2016-137, Schedule 1.1.

True or false?

« R-410A is banned in Canada for air conditioners and heat pumps. »

« Every commercial HVAC project needs engineer’s plans. »

« A small 400 m² warehouse doesn’t need an engineer. »

« Hydro-Québec must approve the project before the work. »

« In Québec, you need a certificate to handle refrigerant. »

« An AHRI-certified split heat pump is enough for Hydro-Québec support. »

Answer to see the explanation.

10 · Why choose AirGreen

Your contractor choice shows in comfort, bills and breakdowns.

Here is what sets us apart, in facts you can check.

Expertise and experience

  • RBQ licence 5645-9605-01: 15.8, 15.10 and 16
  • Professional refrigeration technicians for installation and service
  • Heat pumps, VRF, PTACs, ventilation and refrigeration

Customer-focused approach

  • Free on-site estimate
  • Detailed quote within 24 hours
  • One point of contact, from first call to maintenance

Eco-friendly solutions

  • Heat pumps up to 3 times more efficient than baseboards (Hydro-Québec)
  • Lower-potential refrigerants when there’s a choice
  • Heat recovery from exhaust air

Where we work

Montréal, Laval, Longueuil, the North Shore and the South Shore. Before installing an outdoor unit, check your city’s rules:

11 · Documents to ask for

Eight documents to ask your contractor for, us included.

Check them off as you go. They are also the papers Hydro-Québec asks for before paying support.

0 / 8

12 · Projects and advice

What we see on commercial job sites.

Our articles on commercial air conditioning, ventilation and heating.

All our commercial projects

13 · Frequently asked questions

What property managers and owners ask us.

Type a word to filter the questions.

Québec’s Engineers Act reserves a building’s mechanical, thermal and electrical systems to engineers. Exception: a non-industrial building designed with the complete acceptable solutions of Part 9 of the code (at most 3 storeys and 600 m² of building area). Restaurants, schools, halls, care facilities and industrial buildings are always covered. Our project sheet gives a first answer; your engineer or municipality confirms it.
With AirGreen

Experience the AirGreen difference: we come see your building, for free.

Bring your plans, a Hydro-Québec bill and your questions. The visit is free and the quote goes out within 24 hours.

Or write to sales@airgreen.ca. See all our commercial HVAC services and the AirGreen home page.

Free on-site estimateRoof, panel, plans: we look at everything before we propose.
Quote in 24 hModels, quantities and prices line by line.
RBQ 5645-9605-0115.8 Ventilation, 15.10 Refrigeration, 16 Electrical.
$5M insuranceLiability coverage from start to finish.
ShowroomBoucherville, 514 316-3007. Come see the units.
Sources checked October 14, 2026. Engineers Act, CQLR c. I-9, ss. 2, 3, 3.1 and 24 (LégisQuébec, current to August 12, 2026); Ordre des ingénieurs du Québec, decision aid for buildings (2022); Québec Construction Code, Chapter I, Building (NBC 2020 as amended for Québec), scope of Part 9; Ozone-depleting Substances and Halocarbon Alternatives Regulations (SOR/2016-137), Schedule 1.1 (current to September 21, 2026); MELCCFP, halocarbons and warming potentials; Québec.ca, environmental qualification certificate for halocarbons (H); Régie du bâtiment du Québec, heating, ventilation and refrigeration subclasses; Hydro-Québec, efficient equipment for businesses, heat pumps for businesses, project examples and Efficient Solutions participation guides (March 2026). Amounts shown are estimates; only Hydro-Québec confirms the support granted. This page provides general information: whether an engineer is needed is confirmed by a professional or your municipality.